@inproceedings{HanfstaenglParzingerWirnsbergeretal.2019, author = {Hanfstaengl, Lucia and Parzinger, Michael and Wirnsberger, Markus and Spindler, Uli and Wellisch, Ulrich}, title = {Identifying The Presence Of People In A Room Based On Machine Learning Techniques Using Data Of Room Control Systems}, series = {IEA EBC Annex 71: Building energy performance assessment based on in-situ measurements, 6th expert meeting, April 08.-10. 2019 - Bilbao, ES}, booktitle = {IEA EBC Annex 71: Building energy performance assessment based on in-situ measurements, 6th expert meeting, April 08.-10. 2019 - Bilbao, ES}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:861-opus4-14077}, pages = {1 -- 7}, year = {2019}, abstract = {When monitoring the energy performance of buildings, it may be of interest to identify the occupation periods of people in the room due to their possible impact on the energy balance. In order to be able to carry out a comprehensive energy assessment of the system and building, it is necessary to be able to classify user influence during the evaluation. This thesis investigates how the presence of people in a room can be determined cost-effectively and with little additional effort. The aim is to determine which sensors of a room control system provide sufficiently reliable data. The presence of 1-2 persons was examined on a test facility of the Technical University Rosenheim. The air-, mean radiation- and surface-temperatures, the air humidity as well as the CO2 and VOC concentrations were measured. For the analysis, a method of supervised machine and statistical learning, random forest, is used. The smallest model error detected in predicting the presence of 1 or 2 persons from CO2 sensor data is 1.43\%. The error rates are low for all tested models if time-dynamic effects are used as predictors and the data is processed in a so-called time period form. Additionally, the ways in which this data should ideally be made available for future measurements and processed to facilitate analysis with machine and statistical learning techniques have been investigated. A further goal is to apply the models developed on measurement series in laboratory environments to real rooms and to assess the transferability of these models.}, language = {en} } @inproceedings{HanfstaenglParzingerSpindleretal.2020, author = {Hanfstaengl, Lucia and Parzinger, Michael and Spindler, Uli and Wellisch, Ulrich and Wirnsberger, Markus}, title = {Identifying occupant presence in a room based on machine learning techniques by measuring indoor air conditions}, series = {E3S Web of Conferences, 12th Nordic Symposium on Building Physics (NSB 2020)}, volume = {172}, booktitle = {E3S Web of Conferences, 12th Nordic Symposium on Building Physics (NSB 2020)}, pages = {22005}, year = {2020}, abstract = {Knowing about the presence and number of people in a room can be of interest for precise control of heating, ventilation and air conditioning. To determine the number and presence of occupants cost-effectively, it is of interest to use already existing air condition sensors (temperature, humidity, CO2) of the building automation system. Different approaches and methods for determining presence have attracted attention in recent years. We propose an occupancy detection method based on a method of supervised machine learning. In an experiment, measurement data were recorded in a research apartment with controllable boundary conditions. The presence of people was simulated by artificial injection of water vapour, CO2 and heat dissipation. The variation of the number of artificial users, the duration of presence and the supply air volume flow of the ventilation resulted in a total of 720 combinations. By using artificial users, the boundary conditions were accurately defined, and different presence situations could be measured time-effectively. The data is evaluated with a method of supervised machine learning called random forest. The statistical model can determine precisely the number of people in over 93\% of the cases in a disjoint test sample. The experiments took part in the Rosenheim Technical University of Applied Sciences laboratory.}, language = {en} } @article{ParzingerHanfstaenglSiggetal.2020, author = {Parzinger, Michael and Hanfstaengl, Lucia and Sigg, Ferdinand and Spindler, Uli and Wellisch, Ulrich and Wirnsberger, Markus}, title = {Residual Analysis of Predictive Modelling Data for Automated Fault Detection in Building's Heating, Ventilation and Air Conditioning Systems}, series = {Sustainability}, volume = {12}, journal = {Sustainability}, number = {17}, pages = {6758}, year = {2020}, abstract = {Faults in Heating, Ventilation and Air Conditioning (HVAC) systems affect the energy efficiency of buildings. To date, there rarely exist methods to detect and diagnose faults during the operation of buildings that are both cost-effective and sufficient accurate. This study presents a method that uses artificial intelligence to automate the detection of faults in HVAC systems. The automated fault detection is based on a residual analysis of the predicted total heating power and the actual total heating power using an algorithm that aims to find an optimal decision rule for the determination of faults. The data for this study was provided by a detailed simulation of a residential case study house. A machine learning model and an ARX model predict the building operation. The model for fault detection is trained on a fault-free data set and then tested with a faulty operation. The algorithm for an optimal decision rule uses various statistical tests of residual properties such as the Sign Test, the Turning Point Test, the Box-Pierce Test and the Bartels-Rank Test. The results show that it is possible to predict faults for both known faults and unknown faults. The challenge is to find the optimal algorithm to determine the best decision rules. In the outlook of this study, further methods are presented that aim to solve this challenge.}, language = {en} } @inproceedings{ParzingerWellischHanfstaengletal.2020, author = {Parzinger, Michael and Wellisch, Ulrich and Hanfstaengl, Lucia and Sigg, Ferdinand and Wirnsberger, Markus and Spindler, Uli}, title = {Identifying faults in the building system based on model prediction and residuum analysis}, series = {E3S Web of Conferences, 12th Nordic Symposium on Building Physics (NSB 2020)}, volume = {172}, booktitle = {E3S Web of Conferences, 12th Nordic Symposium on Building Physics (NSB 2020)}, pages = {22001}, year = {2020}, abstract = {The energy efficiency of the building HVAC systems can be improved when faults in the running system are known. To this day, there are no cost-efficient, automatic methods that detect faults of the building HVAC systems to a satisfactory degree. This study induces a new method for fault detection that can replace a graphical, user-subjective evaluation of a building data measured on site with an automatic, data-based approach. This method can be a step towards cost-effective monitoring. For this research, the data from a detailed simulation of a residential case study house was used to compare a faultless operation of a building with a faulty operation. We argue that one can detect faults by analysing the properties of residuals of the prediction to the actual data. A machine learning model and an ARX model predict the building operation, and the method employs various statistical tests such as the Sign Test, the Turning Point Test, the Box-Pierce Test and the Bartels-Rank Test. The results show that the amount of data, the type and density of system faults significantly affect the accuracy of the prediction of faults. It became apparent that the challenge is to find a decision rule for the best combination of statistical tests on residuals to predict a fault.}, language = {en} } @article{ParzingerHanfstaenglSiggetal.2022, author = {Parzinger, Michael and Hanfstaengl, Lucia and Sigg, Ferdinand and Spindler, Uli and Wellisch, Ulrich and Wirnsberger, Markus}, title = {Comparison of different training data sets from simulation and experimental measurement with artificial users for occupancy detection — Using machine learning methods Random Forest and LASSO}, series = {Building and Environment}, volume = {223}, journal = {Building and Environment}, doi = {10.1016/j.buildenv.2022.109313}, pages = {109313}, year = {2022}, abstract = {The applications for occupancy detection range from controlling building automation and systems, determining heat transfer coefficients and even assessing the risk of infection in rooms. Studies in the literature use various statistical models, physical models and machine learning techniques to detect occupancy. All these methods require data for training the occupancy detection models. However, data generation is time-consuming and expensive. This study demonstrates the feasibility of using simulated learning data. Using three different data sources, we tested the suitability of different methods for generating learning data. We conducted two experiments in two office spaces with a real user and an artificial user, and we generated a third data set using a building simulation model. In addition, this study compares two different machine learning approaches (Random Forest and LASSO) using environmental parameters. Both machine learning approaches could develop models with a sensitivity of at least 83 \% and a specificity of at least 97 \% with both training data sets. This work shows that it is possible to determine the presence in rooms using simulated data. The results compared to measured data were just slightly less accurate, and the added value due to the lower effort was considerable}, language = {en} } @techreport{SpindlerWellischKrauseetal.2023, author = {Spindler, Uli and Wellisch, Ulrich and Krause, Harald and Hanfstaengl, Lucia and Parzinger, Michael and Puntigam, Stephan and Sigg, Ferdinand and Wirnsberger, Markus}, title = {Entwicklung einer Methodik zur Bestimmung der Energieeffizienz von Geb{\"a}uden auf Basis von optimierten in situ Messungen}, organization = {Projekttr{\"a}ger J{\"u}lich}, pages = {132}, year = {2023}, abstract = {Geb{\"a}uden haben einen Anteil von 40\% am deutschen Gesamtenergiebedarf und sind damit eine entscheidende Stellschraube beim Erreichen der Klimaziele. Der Energiebedarf von Geb{\"a}uden wird von der Geb{\"a}udeh{\"u}lle und der Geb{\"a}udetechnik bestimmt. Ein Großteil der Geb{\"a}udetechnik wird nicht in optimaler Weise betrieben. So k{\"o}nnen durch die Analyse des Geb{\"a}udes im Rahmen eines technischen Monitorings und anschließender Optimierung, Energieeinsparungen im Bereich von 5\% bis 30\% erzielt werden. Mit der Optimierung der Geb{\"a}udetechnik kann der Energiebedarf von Geb{\"a}uden ohne zus{\"a}tzlichen Ressourcenaufwand reduziert werden. Jedoch ist die Implementierung eines technischen Monitorings in Geb{\"a}uden aufw{\"a}ndig und wird daher, trotz des m{\"o}glichen Einsparpotentials, in nur wenigen Geb{\"a}uden umgesetzt. Um die Verbreitung von technischem Monitoring, und damit die Analysem{\"o}glichkeiten von Geb{\"a}uden, voranzutreiben, wurde im Projekt EnOB: InSitu Nachweisverfahren erforscht, wie mit geringem Aufwand R{\"u}ckschl{\"u}sse auf den Zustand von Geb{\"a}ude getroffen werden k{\"o}nnen. Hierf{\"u}r wurde untersucht welche Parameter gemessen werden m{\"u}ssen um aus einem einfachen Basismonitoring, das {\"u}blicherweise in situ stattfindet, Aussagen zur Geb{\"a}udequalit{\"a}t, Anlagenqualit{\"a}t und Nutzerverhalten treffen zu k{\"o}nnen. Der Schwerpunkt der Untersuchungen im Projekt wurde zum einen auf Untersuchungen zur Detektierung der Anwesenheit von Personen in R{\"a}umen gelegt, als auch auf die automatische Fehlererkennung von Anlagenfehlern. Dabei war ein maßgeblicher Arbeitsaufwand die Entwicklung geeigneter Versuchsreihen und die Aufbereitung der Daten. F{\"u}r die Umsetzung wurden Messungen in einer Forschungswohnung, als auch im Labor f{\"u}r intelligente Geb{\"a}udetechnik, kurz LiGT, erzeugt. Im Rahmen des Projekts wurde das LiGT umgebaut und mit entsprechender Mess- und Geb{\"a}udetechnik ausgestattet. F{\"u}r die Analysen der Daten wurden Methoden des Maschinellen Lernens und der Statistik, wie zum Beispiel Random Forest und LASSO, eingesetzt. F{\"u}r die Erkennung der Anwesenheit sind drei Messreihen durchgef{\"u}hrt worden. Darunter ein Versuch mit zwei realen Personen, ein Versuch mit f{\"u}nf k{\"u}nstlichen Nutzern und ein weiterer Versuch mit der Kombination von Simulations- und Messdaten. Um das Ziel der kosteng{\"u}nstigen Analyse zu erreichen, sollten ohnehin in Geb{\"a}uden verf{\"u}gbare Raumklimasensoren verwendet werden. Die Analyse erfolgte daher auf Raumebene. Unter der Verwendung von CO2-, Temperatur-, Feuchtesensoren in den Innenr{\"a}umen und Solarstrahlungs- und Temperatursensoren im Außenbereich konnte die Personenanzahl im Raum mit hoher Genauigkeit bestimmt werden. F{\"u}r die Anwesenheit von bis zu f{\"u}nf Personen wurde eine Trefferquote von 86,5\% und f{\"u}r den Versuch mittels Simulationen eine Sensitivit{\"a}t von mindestens 83\% und eine Spezifit{\"a}t von mindestens 97\% erzielt. F{\"u}r die automatische Fehlererkennung wurden zwei unterschiedliche Ans{\"a}tze untersucht. Beim ersten Ansatz, welcher auch im Rahmen des Annex 71 vorgeschlagen wurde, wurde ein statistisches Modell mit Messdaten aus einem fehlerfreien Zeitraum trainiert. Mithilfe diesem Modells werden Abweichungen vom fehlerfreien Zustand identifiziert. Dazu wurden Simulationen der Zwillingsh{\"a}user am Fraunhofer Institut f{\"u}r Bauphysik in Holzkirchen verwendet anhand welcher die entwickelte Methoden getestet wurde. Mit dem Ansatz konnte fehlerbehaftete Zeitr{\"a}ume identifiziert werden, jedoch nicht die Art des Fehlers. Im zweiten Ansatz wurden die Fehler selbst simuliert und als Trainingsdaten f{\"u}r die statistischen Modelle verwendet. Zur Validierung des Verfahrens wurden Daten eines realen Geb{\"a}udes analysiert. Zur Generierung der Messdaten wurden im LiGT Messungen durchgef{\"u}hrt. Hierbei wurden zu unterschiedlichen Zeitpunkten drei unterschiedliche Fehler k{\"u}nstlich herbeigef{\"u}hrt. Die Qualit{\"a}t der Fehlererkennung ist dabei maßgeblich von der Qualit{\"a}t der Simulation und der Art des Fehlers abh{\"a}ngig. Im Projekt wurden sowohl Methoden zur Anwesenheitserkennung, als auch zur automatisierten Fehlererkennung von Anlagen entwickelt. Diese Erkenntnisse k{\"o}nnen in einem Basismonitoring zur Untersuchung von Geb{\"a}udequalit{\"a}t, Anlagenqualit{\"a}t und Nutzerverhalten verwendet werden. Automatisierte Methoden haben in Zukunft einen wesentlichen Einfluss auf den Erfolg und die Anwendbarkeit von technischem Monitoring.}, language = {de} }