Labor Biomaterialien
Refine
Document Type
- Article (6)
Language
- English (6)
Has Fulltext
- no (6) (remove)
Is part of the Bibliography
- no (6)
Keywords
- Adhesives (1)
- Bioactivity (1)
- Biodegradable materials (1)
- Biomaterials (1)
- Bond strength (1)
- Chitosan (1)
- Coatings (1)
- Conversion (1)
- Corrosion rate (1)
- Dental membrane (1)
Institute
- Fakultät Maschinenbau (6) (remove)
Begutachtungsstatus
- peer-reviewed (6) (remove)
Operational wear behaviour of 3D-printed lightweight metal gears: EDS and oil analysis comparison
(2024)
Additive manufacturing (AM) has come to the fore in recent years among manufacturing techniques. This technique, which has different advantages than traditional ones such as casting, forging and machining, is expected to be widely used in producing machine parts like gears in the coming years. Therefore, experimental data on AM parameters for lightweight metal gears are important for industrial production. In this study, a wear test was applied to AlSi10Mg and Ti6Al4V gears under operational conditions, and the wear behaviour of conventionally and additively manufactured gears was compared. The amount of abrasion elements was determined by analysing the oil in the gearbox. In addition, gear surfaces were analysed using scanning electron microscopy and an energy-dispersive spectrometer before and after wear. Thus, the wear behaviour of gears produced by conventional and AM under service conditions was demonstrated comparatively.
Mg and Mg alloys are becoming more and more of interest for several applications. In the case of biomaterial applications, a special interest exists due to the fact that a predictable degradation should be given. Various investigations were made to characterize and predict the corrosion behavior in vitro and in vivo. Mostly, the simple oxidation of Mg to Mg2+ ions connected with adequate hydrogen development is assumed, and the negative difference effect (NDE) is attributed to various mechanisms and electrochemical results. The aim of this paper is to compare the different views on the corrosion pathway of Mg or Mg alloys and to present a neglected pathway based on thermodynamic data as a guideline for possible reactions combined with experimental observations of a delay of visible hydrogen evolution during cyclic voltammetry. Various reaction pathways are considered and discussed to explain these results, like the stability of the Mg+ intermediate state, the stability of MgH2 and the role of hydrogen overpotential. Finally, the impact of MgH2 formation is shown as an appropriate base for the prediction of the degradation behavior and calculation of the corrosion rate of Mg and Mg alloys.
This review comprehensively covers research carried out in the field of degradable coatings on Mg and Mg alloys for biomedical applications. Several coating methods are discussed, which can be divided, based on the specific processing techniques used, into conversion and deposition coatings. The literature review revealed that in most cases coatings increase the corrosion resistance of Mg and Mg alloys. The critical factors determining coating performance, such as corrosion rate, surface chemistry, adhesion and coating morphology, are identified and discussed. The analysis of the literature showed that many studies have focused on calcium phosphate coatings produced either using conversion or deposition methods which were developed for orthopaedic applications. However, the control of phases and the formation of cracks still appear unsatisfactory. More research and development is needed in the case of biodegradable organic based coatings to generate reproducible and relevant data. In addition to biocompatibility, the mechanical properties of the coatings are also relevant, and the development of appropriate methods to study the corrosion process in detail and in the long term remains an important area of research.
Bioresorbable materials are under investigation due to their promising properties for applications as implant material. This study is about the degradation and bioactivity behaviour of magnesium foils, which allegorize dental membranes. The degradation behaviour including pitting corrosion during immersion tests can be precisely observed using micro-computed tomography. Using the bioactivity test according to Kokubo, it is shown that magnesium has strong Ca-phosphate layer formation correlated with high degradation. Therefore, magnesium foils appear to hold a great potential for bone implant application.
Electrophoretic chitosan deposits on stainless steel AISI 316 L were produced and characterized. The coating quality (thickness, defectiveness, corrosion protection ability) was seen to depend on the electric field used for EPD. Corrosion studies in concentrated simulated body fluid (SBF5) demonstrated that the surface characteristics of AISI 316 L can be positively influenced by the chitosan coating.
The bond between methacrylic polymer adhesives and dental restoratives is not perfect and may fail either in the short or in the long term. This study aims to evaluate the effects of particle incorporation in a self-etch model adhesive on mechanical and physical properties that are relevant during application and service. Filled adhesives containing 5, 10, 15 or 25 wt% glass fillers were compared to their unfilled counterpart in terms of water sorption and solubility; viscosity and dynamic viscosity during polymerization were recorded using rheological measurements and compared to FTIR analysis of the real-time degree of cure. Elastic modulus and ultimate tensile strength measurements were performed in uniaxial tension; the energy to fracture was used to calculate the fracture toughness of the adhesives. Finally, the experimental adhesives were applied on dentin substrate to test the bond strength using the microtensile test. Results showed that the incorporation of 5–10 wt% nanofiller to self-etching dental adhesives is efficient in accelerating the polymerization reaction and increasing the degree of cure without compromising the film viscosity for good wettability or water sorption and solubility. Fillers increased the elastic modulus, tensile strength and fracture toughness to a plateau between 5 and 15 wt% filler concentration, and despite the tendency to form agglomerations, active crack pinning/deflection toughening mechanisms have been observed. The bond strength between resin composite and dentin was also improved when adhesives with up to 10 wt% fillers were used, with no additional improvements with further packing. The use of fillers to reinforce dental adhesives may therefore be of great practical benefit by improving curing and mechanical properties.