Corresponding author der OTH Regensburg
Refine
Year of publication
Document Type
- Article (56)
- Part of a Book (1)
- conference proceeding (article) (1)
- conference talk (1)
- conference proceeding (volume) (1)
Has Fulltext
- no (60) (remove)
Is part of the Bibliography
- no (60)
Keywords
- Handchirurgie (3)
- Lernprogramm (3)
- Photoacoustic spectroscopy (3)
- magnetoactive elastomer (3)
- 3D-Druck (2)
- Acetone breath analysis (2)
- Acetone detection (2)
- Biomechanik (2)
- Dual-material 3D printing (2)
- High power UV LED (2)
Institute
- Fakultät Elektro- und Informationstechnik (20)
- Fakultät Maschinenbau (19)
- Regensburg Center of Biomedical Engineering - RCBE (12)
- Labor Intelligente Materialien und Strukturen (11)
- Fakultät Informatik und Mathematik (9)
- Fakultät Angewandte Natur- und Kulturwissenschaften (7)
- Mechatronics Research Unit (MRU) (6)
- Labor Biomechanik (LBM) (5)
- Regensburg Center of Health Sciences and Technology - RCHST (5)
- Regensburg Medical Image Computing (ReMIC) (4)
Begutachtungsstatus
- peer-reviewed (59)
Background:
With the prevalence of burnout among surgeons posing a significant threat to healthcare outcomes, the mental toughness of medical professionals has come to the fore. Mental toughness is pivotal for surgical performance and patient safety, yet research into its dynamics within a global and multi-specialty context remains scarce. This study aims to elucidate the factors contributing to mental toughness among surgeons and to understand how it correlates with surgical outcomes and personal well-being.
Methods:
Utilizing a cross-sectional design, this study surveyed 104 surgeons from English and German-speaking countries using the Mental Toughness Questionnaire (MTQ-18) along with additional queries about their surgical practice and general life satisfaction. Descriptive and inferential statistical analyses were applied to investigate the variations in mental toughness across different surgical domains and its correlation with professional and personal factors.
Results:
The study found a statistically significant higher level of mental toughness in micro-surgeons compared to macro-surgeons and a positive correlation between mental toughness and surgeons' intent to continue their careers. A strong association was also observed between general life satisfaction and mental toughness. No significant correlations were found between the application of psychological skills and mental toughness.
Conclusion:
Mental toughness varies significantly among surgeons from different specialties and is influenced by professional dedication and personal life satisfaction. These findings suggest the need for targeted interventions to foster mental toughness in the surgical community, potentially enhancing surgical performance and reducing burnout. Future research should continue to explore these correlations, with an emphasis on longitudinal data and the development of resilience-building programs.
The third-order nonlinear susceptibility of silica glass is measured via self-phase modulation in standard single mode fibers at a wavelength of 1550 nm. To minimize the influence of polarization state changes along the propagation only meter-long fibers were investigated. With pulse durations of picoseconds a quasi-instantaneous nonlinearity with ultrafast electronic and fast nuclear-vibration contributions produces under conditions of negligible dispersion a classic and clean nonlinear phase shift following exactly the shape of the pulse power. The complex pulse envelope was retrieved from frequency optical gating spectrograms. The nonlinear fiber parameter γ could be determined with an accuracy of 3.7 percent. Considering the mode field structure and the doping influence the nonlinear refractive index of silica glass as the fiber base material was found to be n 2 =2.22⋅10 −16 cm 2 W±6.0% for picosecond-long pulses. Comparing nonlinear phase shifts from linear and circular polarized light a nuclear-vibration contribution to the cubic fiber nonlinearity of 25 percent was estimated.
Friction has long been an important issue in multibody dynamics. Static friction models apply appropriate regularization techniques to convert the stick inequality and the non-smooth stick–slip transition of Coulomb’s approach into a continuous and smooth function of the sliding velocity. However, a regularized friction force is not able to maintain long-term stick. That is why dynamic friction models were developed in recent decades. The friction force depends herein not only on the sliding velocity but also on internal states. The probably best-known representative, the LuGre friction model, is based on a fictitious bristle but realizes a too-simple approximation. The recently published second-order dynamic friction model describes the dynamics of a fictitious bristle more accurately. It is based on a regularized friction force characteristic, which is continuous and smooth but can maintain long-term stick due to an appropriate shift in the regularization. Its performance is compared here to stick–slip friction models, developed and launched not long ago by commercial multibody software packages. The results obtained by a virtual friction test-bench and by a more practical festoon cable system are very promising. Thus, the second-order dynamic friction model may serve not only as an alternative to the LuGre model but also to commercial stick–slip models.
Commercially available contact angle (CA) measuring devices usually do not allow for the application of magnetic fields to the sample under test. A setup for measuring the CA of liquids on magnetosensitive surfaces has been developed specifically for investigating the surfaces of magnetoactive elastomers (MAEs). The addition of a programmable linear stage, which moves a permanent magnet, allows for fine control of the magnetic field applied to the MAE without the need for large and power-consuming electromagnets. Paired with a custom control and evaluation software, this measurement setup operates semiautomatically, limiting operator error and increasing precision, speed, as well as repeatability of static and dynamic CA measurements for different magnetoactive materials. The software is equipped with robust droplet fitting algorithms to avoid experimental challenges arising with soft magnetoactive materials, such as the curling of sample edges or diffuse non-reflective surfaces. Several application examples on MAE surfaces, both processed and unprocessed, are presented.
Green hydrogen via renewable powered electrolysis has a high relevance in decarbonization and supply security. Achieving economically competitive hydrogen production costs is a major challenge in times of an energy price crisis. Our objective is to show the economically optimal installed capacity of electrolysers in relation to wind and solar power so swift and credible statements can be made regarding the system design. The ratio between renewable generation and electrolysis power as well as scaling effects, operating behaviour and development of costs are considered. Hydrogen production costs are calculated for four exemplary real PV and wind sites and different ratios of electrolysis to renewable power for the year 2020. The ideal ratio for PV systems is between 14% and 73% and for wind between 3.3% and 143% for low and high full load hours. The lowest hydrogen production costs are identified at 2.53 €/kg for 50 MW wind power and 72 MW electrolysis power. The results provide plant constructors the possibility to create a cost-optimized design via an optimum ratio of electrolysis to renewable capacity. Therefore, the procedures for planning and dimensioning of selected systems can be drastically simplified.
Improvements for building-performance simulations by a comparative finite-element method analysis
(2023)
This paper presents a method to improve building-performance simulations (BPS) by the comparison and analysis of different approaches based on finite-element method (FEM) models. The lumped parameter method (LPM) is used in several BPS programs and tools. It has the advantage of fast computing times and comparably good accuracy for thermal and energy loads. With the help of detailed FEM simulations, it is possible to further improve the degree of detail and accuracy while maintaining the high simulation speed.
In this work, we compare time-dependent results for local temperatures in a generic reference room within a given periode of time. In a second step, the differences between the models with respect to various physical effects are analyzed and used to introduce additional equations into the LPM model in order to improve its accuracy. Thus, we discuss potentials for improvement for BPS and demonstrate a method of a practical implementation.
The results show minor differences of less than 0.1 K for radiation and heat transfer, so their level of detail in BPS is appropriate. In these terms, no improvements were pursued within the work. However, the FEM simulation is capable of calculating the internal convective heat transfer and thermal bridges more accurately due to the use of computational fluid dynamics (CFD) and the geometrically precise representation of the FEM model. Here, deviations of up to 1 K in room temperature (convective heat transfer) and up to 0.5 K in wall temperatures (thermal bridges) were pointed out.
By improving the LPM with equations obtained from the FEM, these deviations can be reduced to less than 0.2 K, which is a considerable improvement in accuracy.
In fatigue strength assessment, the methods based on ideal elastic stresses according to Basquin and the less established method based on elastic-plastic stress quantities according to Manson, Coffin and Morrow are applied. The former calculates loads using linear-elastic stresses, the latter requires elasticplastic evaluation parameters, such as stresses and strains. These can be determined by finite element analysis (FEA) with a linear-elastic constitutive law, and subsequent conversion to elastic-plastic loads, using the macro support formula by Neuber. In this contribution, an alternative approach to approximate elastic-plastic parameters proposed by Glinka is compared to the the strain-life method using Neuber's formula, as well as the stress-life method of Basquin. Several component tests on 42CrMoS4-QT specimens are investigated. To determine the input data for the fatigue strength evaluations, the entire test setup is computed by FEA. The nodal displacements from these validated full-model simulations are used as boundary conditions for a submodel simulation of a notch, whose results serve as input for the fatigue strength assessments. It is shown that all approaches provide a reliable assessment of components. Our key result is that the strain-life method using the concept by Glinka for notch stress computation, yields improved results in fatigue strength assessments.
Hydrogen storage based on the repeated reduction and oxidation (redox) reactions of iron oxide/iron composites represents a promising technology. This work is dedicated to studying the influence of the amount of water added during the pelletizing process on the cycle stability and structure of iron oxide pellets. The storage composites were prepared from iron oxide (Fe2O3) and 10 wt.-% support material (cement) with different amounts of water (18 and 33 wt.-%) in a laboratory-scale pelletizing disk. To evaluate the cycle stability of the composites, the kinetics of the redox reactions were experimentally measured at 800 ∘
C in an atmosphere of 50% N2 and 50% H2 (reduction) or 50% steam (oxidation), respectively. Moreover, the structure of the pellets was analyzed by micro-computed tomography scans. It turned out that pellets with higher water contents attained faster kinetics and a higher cycle stability. The sample with the least water content (18 wt.-%) needed about 26 min and 19 min to reach a conversion rate of 80% during the reduction and oxidation reactions of the sixth redox cycle, respectively. In contrast, the sample with the highest water content (33 wt.-%) could achieve the same conversion rate after 18 min (reduction) and 13 min (oxidation) during the ninth redox cycle.
Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far.
BACKGROUND:
Tracheobronchial mucus plays a crucial role in pulmonary function by providing protection against inhaled pathogens. Due to its composition of water, mucins, and other biomolecules, it has a complex viscoelastic rheological behavior. This interplay of both viscous and elastic properties has not been fully described yet. In this study, we characterize the rheology of human mucus using oscillatory and transient tests. Based on the transient tests, we describe the material behavior of mucus under stress and strain loading by mathematical models.
METHODS:
Mucus samples were collected from clinically used endotracheal tubes. For rheological characterization, oscillatory amplitude-sweep and frequency-sweep tests, and transient creep-recovery and stress-relaxation tests were performed. The results of the transient test were approximated using the Burgers model, the Weibull distribution, and the six-element Maxwell model. The three-dimensional microstructure of the tracheobronchial mucus was visualized using scanning electron microscope imaging.
RESULTS:
Amplitude-sweep tests showed storage moduli ranging from 0.1 Pa to 10000 Pa and a median critical strain of 4 %. In frequency-sweep tests, storage and loss moduli increased with frequency, with the median of the storage modulus ranging from 10 Pa to 30 Pa, and the median of the loss modulus from 5 Pa to 14 Pa. The Burgers model approximates the viscoelastic behavior of tracheobronchial mucus during a constant load of stress appropriately (R2 of 0.99), and the Weibull distribution is suitable to predict the recovery of the sample after the removal of this stress (R2 of 0.99). The approximation of the stress-relaxation test data by a six-element Maxwell model shows a larger fit error (R2 of 0.91).
CONCLUSIONS:
This study provides a detailed description of all process steps of characterizing the rheology of tracheobronchial mucus, including sample collection, microstructure visualization, and rheological investigation. Based on this characterization, we provide mathematical models of the rheological behavior of tracheobronchial mucus. These can now be used to simulate mucus flow in the respiratory system through numerical approaches.
This paper introduces the results of an experimental study on the adsorption and desorption kinetics of a commercially available, open-structured asymmetric plate heat exchanger adapted to act as an adsorber/desorber for the application in adsorption heat transformation processes. In addition, a volumetric large temperature jump (V-LTJ) kinetic setup was applied to measure the adsorption and desorption kinetics of a small-scale adsorbent sample prepared dedicatedly to be representative for the adsorbent domain inside the investigated adsorber plate heat exchanger (APHE). All kinetic results of the small-scale adsorbent sample and the APHE were fitted into exponential forms with a single characteristic time constant (τ) with a coefficient of determination (R2) better than 0.9531. A very good matching between the small-scale and full-scale adsorption kinetic measurements was obtained, with an average relative deviation of 12.3% in the obtained τ-values. In addition, the kinetic data of the small-scale adsorbent sample were utilized for estimating the expected specific instantaneous and moving average powers of the evaporator/condenser heat exchanger. The average relative deviation (ARD) between the moving average specific evaporator powers obtained from the small-scale and the full-scale measurements amounts between 5.4 and 15.1%.
Der Beitrag zeigt Ergebnisse einer Begleitstudie zur Restaurierung und energetischen Modernisierung des historischen genossenschaftlichen Wohnquartiers Margaretenau in Regensburg im Projekt MAGGIE. Bei der Gestaltung von Wohnungen und Gelegenheiten für die soziale Einbettung im Quartier wird eine altersgerechte Perspektive eingenommen. Die Darstellung der schriftlichen standardisierten Haushaltsbefragung (n = 195) nimmt die Lebenssituation älterer Menschen ab 65 Jahren in den Fokus. Dazu werden die Themenbereiche Haushaltsstruktur, altersgerechtes Wohnen und Gemeinschaftseinrichtungen präsentiert. Neben der aktuellen Wohnsituation wurden Pläne und Wünsche für das zukünftige Wohnen abgefragt. Im Alter schwindet die Bereitschaft für Veränderungen, was sich am Wunsch zum Altern in der bisherigen Wohnung und Verbleib im Wohnquartier zeigt. Das Interesse am barrierereduzierten Wohnen ist bei älteren Haushalten geringer als bei jüngeren. Es zeigt sich ein überdurchschnittlich hohes Maß an lokalem Sozialkapital, wobei kein signifikanter Unterschied zwischen jüngeren und älteren Haushalten besteht.
Quality and reliability are of the utmost importance for manufacturing in the optical and medical industries. Absorber-free laser transmission welding enables the precise joining of identical polymers without additives or adhesives and is well-suited to meet the demands of the aforementioned industries. To attain sufficient absorption of laser energy without absorbent additives, thulium fiber lasers, which emit in the polymers’ intrinsic absorption spectrum, are used. Focusing the laser beam with a high numerical aperture provides significant intensity gradients inside the workpiece and enables selective fusing of the internal joining zone without affecting the surface of the device. Because seam size and position are crucial, the high-quality requirements demand internal weld seam monitoring. In this work, we propose a novel method to determine weld seam location and size using optical coherence tomography. Changes in optical material properties because of melting and re-solidification during welding allow for weld seam differentiation from the injection-molded base material. Automatic processing of the optical coherence tomography data enables the identification and measurement of the weld seam geometry. The results from our technique are consistent with microscopic images of microtome sections and demonstrate that weld seam localization in polyamide 6 is possible with an accuracy better than a tenth of a millimeter.
Final assembly at Krones AG must make the best possible use of its production space and meeting the specified customer due dates is critical. Via a self developed simulation tool, the present scheduling procedure is compared with the one by priority rule shortest slack. As a consequence slack should have a higher importance in the planning
We demonstrate the control of wettability of non-structured and microstructured magnetoactive elastomers (MAEs) by magnetic field. The synthesized composite materials have a concentration of carbonyl iron particles of 75 wt.% (≈27 vol.%) and three different stiffnesses of the elastomer matrix. A new method of fabrication of MAE coatings on plastic substrates is presented, which allows one to enhance the response of the apparent contact angle to the magnetic field by exposing the particle-enriched side of MAEs to water. A magnetic field is not applied during crosslinking. The highest variation of the contact angle from (113 ± 1)° in zero field up to (156 ± 2)° at about 400 mT is achieved in the MAE sample with the softest matrix. Several lamellar and pillared MAE structures are fabricated by laser micromachining. The lateral dimension of surface structures is about 50 µm and the depth varies between 3 µm and 60 µm. A systematic investigation of the effects of parameters of laser processing (laser power and the number of passages of the laser beam) on the wetting behavior of these structures in the absence and presence of a magnetic field is performed. In particular, strong anisotropy of the wetting behavior of lamellar structures is observed. The results are qualitatively discussed in the framework of the Wenzel and Cassie-Baxter models. Finally, directions of further research on magnetically controlled wettability of microstructured MAE surfaces are outlined. The obtained results may be useful for the development of magnetically controlled smart surfaces for droplet-based microfluidics.
This work aims at investigating the kinetic mechanisms of the reduction/oxidation (redox) reactions of iron oxide/iron pellets under different operating conditions. The reaction principle is the basis of a thermochemical hydrogen storage system. To simulate the charging phase, a single pellet consisting of iron oxide (90% Fe2O3, 10% stabilising cement) is reduced with different hydrogen (H2) concentrations at temperatures between 600 and 800 °C. The discharge phase is initiated by the oxidation of the previously reduced pellet by water vapour (H2O) at different concentrations in the same temperature range. In both reactions, nitrogen (N2) is used as a carrier gas. The redox reactions have been experimentally measured in a thermogravimetric analyser (TGA) at a flow rate of 250 mL/min. An extensive literature review has been conducted on the existing reactions’ kinetic mechanisms along with their applicability to describe the obtained results. It turned out that the measured kinetic results can be excellently described with the so-called shrinking core model. Using the geometrical contracting sphere reaction mechanism model, the concentration- and temperature-dependent reduction and oxidation rates can be reproduced with a maximum deviation of less than 5%. In contrast to the reduction process, the temperature has a smaller effect on the oxidation reaction kinetics, which is attributed to 71% less activation energy (Ea,Re=56.9 kJ/mol versus Ea,Ox=16.0 kJ/mol). The concentration of the reacting gas showed, however, an opposite trend: namely, to have an almost twofold impact on the oxidation reaction rate constant compared to the reduction rate constant.
In this work, multiferroic cantilevers comprise a layer of a magnetoactive elastomer (MAE) and a commercially available piezoelectric polymer-based vibration sensor. The structures are fixed at one end in the horizontal plane and the magnetic field is applied vertically. First, the magnetoelectric (ME) response to uniform, triangle-wave magnetic fields with five different slew rates is investigated experimentally. Time and field dependences of the generated voltage, electric charge, and observed mechanical deflection are obtained and compared for four different thicknesses of the MAE layer. The ME responses to triangular and sinusoidal wave excitations are examined in contrast. Second, the ME response at low frequencies (≤3 Hz) is studied by the standard method of harmonic magnetic field modulation. The highest ME coupling coefficient is observed in the bias magnetic field strength of ≈73 kA/m and it is estimated to be about 3.3 ns/m (ME voltage coefficient ≈ 25 V/A) at theoretically vanishing modulation frequency (f→0 Hz). Presented results demonstrate that the investigated heterostructures are promising for applications as magnetic-field sensors and energy harvesting devices.
Special issue ISARC 2021
(2022)
The research filed of construction robotics broadens increasingly in terms of complexity, approaches, technologies used, active stakeholders, and application areas. Worldwide labour and resource shortages, the need to increase circularity and resource efficiency, new materials and the increasing utilisation of digital construction tools in the planning and construction industry massively spur the uptake of robotic solutions for on-site construction.
The initial boom of construction robots happened in the 1970s, driven by the Japanese construction industry. In the 1980s, a combination with parallel developments was supposed to achieve complete, integrated robotic on-site factories. From the mid-1980s onwards, the global interest in construction robots decreased gradually. Bulky and expensive systems, complex on-site navigation and logistics approaches, a narrow scope of tasks, inflexibility, incompatibility with on-site work organisation and professional qualification, low usability and insufficient inter-robot coordination capabilities revealed the immaturity of the systems. Only a few organisations predominantly situated in Asia such as Takenaka, Obayashi, Kajima Corporation, Nihon Bisho Co., Samsung, and Hitachi maintained development activities.
However, since the mid-2010s, development activities are gaining traction again. On the application side, this is mainly driven by trends such as the need to upgrade the energy performance of buildings in Europe, a global necessity to remove asbestos from existing structures, and a demand for enormous quantities of high-rise buildings all over East Asia. On the system side, the renewed interest stems from major advances in physical–mechanical robot technology in other automation-driven industries such as the automotive industry. Robots became lighter, more flexible, their parts modular and interchangeable, more user friendly as well as significantly cheaper. On the digital side, the BIM-to-Robot pipeline was subject of intensive reserach and development. More and more methods and tools help to increase the usability of robots and facilitate the simulation and optimisation of robot-driven construction processes.
In the last 4–5 years, the worldwide growing need and interest in construction robotics became highly evident. More than 200 robot systems are pushed by start-ups and spin-offs and their investors to the market. This is backed by an enormous number of activities and projects carried out in the academic area pushing to the boundaries of what is technologically possible.
Major associations and their conferences increase significantly in popularity such as ISARC (International Association for Automation and Robotics in Construction), EC3 (European Council of Computing in Construction), and Robots in Architecture. Competency in digital construction, automation and robotics becomes a key for all stakeholders in the construction industry and many universities worldwide launch dedicated interdisciplinary programs. Powerful governments (China) and major funding programs such as Horizon Europe (Europe) massively request and fund the development of robotic solutions for construction such as drones, mobile robots, 3D-printing solutions, cable-driven robots, and exoskeletons. Regulators and standardisation organisation start to develop the first certification and standardisation schemes for construction robots and large software companies make attempts to allow to simulate and program robotic construction processes efficiently and robustly based on digital building and construction data.
To showcase the diversity of cutting-edge research in the area, this special issue invited eight extended versions of selected papers from the ISARC 2021 conference. As such, this issue covers digital approaches to embed fabrication and robot information in BIM and IFC and program robots directly from digital building models. New robot systems spur novel robotic production processes, and machine learning enable novel logistics approaches for building components that may ultimately lead to robotic cranes and other robotic on-site logistics and handling solutions (including autonomous construction machines). In parallel, systematic evaluation and robot development methods are developed that allow to shed light on their performance in the construction process.
Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing
(2022)
BACKGROUND:
Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements.
OBJECTIVE:
For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture.
METHODS:
Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position.
RESULTS:
The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture.
CONCLUSIONS:
Elevating the right shoulder while playing the violin may pose a potential problem.