Corresponding author der OTH Regensburg
Refine
Year of publication
- 2023 (10) (remove)
Document Type
Language
- English (10)
Has Fulltext
- no (10) (remove)
Is part of the Bibliography
- no (10)
Keywords
- 42CrMoS4-QT (1)
- Acetone (1)
- Breath analysis (1)
- Building performance simulation (1)
- Finite-element method (1)
- Glinka (1)
- Lumped parameter model (1)
- Photoacoustic spectroscopy (1)
- Quantum cascade laser (1)
- Spectral simulation (1)
Institute
- Fakultät Maschinenbau (4)
- Fakultät Elektro- und Informationstechnik (3)
- Fakultät Angewandte Natur- und Kulturwissenschaften (2)
- Fakultät Bauingenieurwesen (1)
- Labor Bauphysik (1)
- Labor Biofluidmechanik (1)
- Labor Heizungs- und Klimatechnik (1)
- Labor Intelligente Materialien und Strukturen (1)
- Labor Sorptionsprozesse (1)
- Regensburg Center of Biomedical Engineering - RCBE (1)
Begutachtungsstatus
- peer-reviewed (10)
The third-order nonlinear susceptibility of silica glass is measured via self-phase modulation in standard single mode fibers at a wavelength of 1550 nm. To minimize the influence of polarization state changes along the propagation only meter-long fibers were investigated. With pulse durations of picoseconds a quasi-instantaneous nonlinearity with ultrafast electronic and fast nuclear-vibration contributions produces under conditions of negligible dispersion a classic and clean nonlinear phase shift following exactly the shape of the pulse power. The complex pulse envelope was retrieved from frequency optical gating spectrograms. The nonlinear fiber parameter γ could be determined with an accuracy of 3.7 percent. Considering the mode field structure and the doping influence the nonlinear refractive index of silica glass as the fiber base material was found to be n 2 =2.22⋅10 −16 cm 2 W±6.0% for picosecond-long pulses. Comparing nonlinear phase shifts from linear and circular polarized light a nuclear-vibration contribution to the cubic fiber nonlinearity of 25 percent was estimated.
Friction has long been an important issue in multibody dynamics. Static friction models apply appropriate regularization techniques to convert the stick inequality and the non-smooth stick–slip transition of Coulomb’s approach into a continuous and smooth function of the sliding velocity. However, a regularized friction force is not able to maintain long-term stick. That is why dynamic friction models were developed in recent decades. The friction force depends herein not only on the sliding velocity but also on internal states. The probably best-known representative, the LuGre friction model, is based on a fictitious bristle but realizes a too-simple approximation. The recently published second-order dynamic friction model describes the dynamics of a fictitious bristle more accurately. It is based on a regularized friction force characteristic, which is continuous and smooth but can maintain long-term stick due to an appropriate shift in the regularization. Its performance is compared here to stick–slip friction models, developed and launched not long ago by commercial multibody software packages. The results obtained by a virtual friction test-bench and by a more practical festoon cable system are very promising. Thus, the second-order dynamic friction model may serve not only as an alternative to the LuGre model but also to commercial stick–slip models.
Commercially available contact angle (CA) measuring devices usually do not allow for the application of magnetic fields to the sample under test. A setup for measuring the CA of liquids on magnetosensitive surfaces has been developed specifically for investigating the surfaces of magnetoactive elastomers (MAEs). The addition of a programmable linear stage, which moves a permanent magnet, allows for fine control of the magnetic field applied to the MAE without the need for large and power-consuming electromagnets. Paired with a custom control and evaluation software, this measurement setup operates semiautomatically, limiting operator error and increasing precision, speed, as well as repeatability of static and dynamic CA measurements for different magnetoactive materials. The software is equipped with robust droplet fitting algorithms to avoid experimental challenges arising with soft magnetoactive materials, such as the curling of sample edges or diffuse non-reflective surfaces. Several application examples on MAE surfaces, both processed and unprocessed, are presented.
Green hydrogen via renewable powered electrolysis has a high relevance in decarbonization and supply security. Achieving economically competitive hydrogen production costs is a major challenge in times of an energy price crisis. Our objective is to show the economically optimal installed capacity of electrolysers in relation to wind and solar power so swift and credible statements can be made regarding the system design. The ratio between renewable generation and electrolysis power as well as scaling effects, operating behaviour and development of costs are considered. Hydrogen production costs are calculated for four exemplary real PV and wind sites and different ratios of electrolysis to renewable power for the year 2020. The ideal ratio for PV systems is between 14% and 73% and for wind between 3.3% and 143% for low and high full load hours. The lowest hydrogen production costs are identified at 2.53 €/kg for 50 MW wind power and 72 MW electrolysis power. The results provide plant constructors the possibility to create a cost-optimized design via an optimum ratio of electrolysis to renewable capacity. Therefore, the procedures for planning and dimensioning of selected systems can be drastically simplified.
Improvements for building-performance simulations by a comparative finite-element method analysis
(2023)
This paper presents a method to improve building-performance simulations (BPS) by the comparison and analysis of different approaches based on finite-element method (FEM) models. The lumped parameter method (LPM) is used in several BPS programs and tools. It has the advantage of fast computing times and comparably good accuracy for thermal and energy loads. With the help of detailed FEM simulations, it is possible to further improve the degree of detail and accuracy while maintaining the high simulation speed.
In this work, we compare time-dependent results for local temperatures in a generic reference room within a given periode of time. In a second step, the differences between the models with respect to various physical effects are analyzed and used to introduce additional equations into the LPM model in order to improve its accuracy. Thus, we discuss potentials for improvement for BPS and demonstrate a method of a practical implementation.
The results show minor differences of less than 0.1 K for radiation and heat transfer, so their level of detail in BPS is appropriate. In these terms, no improvements were pursued within the work. However, the FEM simulation is capable of calculating the internal convective heat transfer and thermal bridges more accurately due to the use of computational fluid dynamics (CFD) and the geometrically precise representation of the FEM model. Here, deviations of up to 1 K in room temperature (convective heat transfer) and up to 0.5 K in wall temperatures (thermal bridges) were pointed out.
By improving the LPM with equations obtained from the FEM, these deviations can be reduced to less than 0.2 K, which is a considerable improvement in accuracy.
In fatigue strength assessment, the methods based on ideal elastic stresses according to Basquin and the less established method based on elastic-plastic stress quantities according to Manson, Coffin and Morrow are applied. The former calculates loads using linear-elastic stresses, the latter requires elasticplastic evaluation parameters, such as stresses and strains. These can be determined by finite element analysis (FEA) with a linear-elastic constitutive law, and subsequent conversion to elastic-plastic loads, using the macro support formula by Neuber. In this contribution, an alternative approach to approximate elastic-plastic parameters proposed by Glinka is compared to the the strain-life method using Neuber's formula, as well as the stress-life method of Basquin. Several component tests on 42CrMoS4-QT specimens are investigated. To determine the input data for the fatigue strength evaluations, the entire test setup is computed by FEA. The nodal displacements from these validated full-model simulations are used as boundary conditions for a submodel simulation of a notch, whose results serve as input for the fatigue strength assessments. It is shown that all approaches provide a reliable assessment of components. Our key result is that the strain-life method using the concept by Glinka for notch stress computation, yields improved results in fatigue strength assessments.
Hydrogen storage based on the repeated reduction and oxidation (redox) reactions of iron oxide/iron composites represents a promising technology. This work is dedicated to studying the influence of the amount of water added during the pelletizing process on the cycle stability and structure of iron oxide pellets. The storage composites were prepared from iron oxide (Fe2O3) and 10 wt.-% support material (cement) with different amounts of water (18 and 33 wt.-%) in a laboratory-scale pelletizing disk. To evaluate the cycle stability of the composites, the kinetics of the redox reactions were experimentally measured at 800 ∘
C in an atmosphere of 50% N2 and 50% H2 (reduction) or 50% steam (oxidation), respectively. Moreover, the structure of the pellets was analyzed by micro-computed tomography scans. It turned out that pellets with higher water contents attained faster kinetics and a higher cycle stability. The sample with the least water content (18 wt.-%) needed about 26 min and 19 min to reach a conversion rate of 80% during the reduction and oxidation reactions of the sixth redox cycle, respectively. In contrast, the sample with the highest water content (33 wt.-%) could achieve the same conversion rate after 18 min (reduction) and 13 min (oxidation) during the ninth redox cycle.
Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far.
BACKGROUND:
Tracheobronchial mucus plays a crucial role in pulmonary function by providing protection against inhaled pathogens. Due to its composition of water, mucins, and other biomolecules, it has a complex viscoelastic rheological behavior. This interplay of both viscous and elastic properties has not been fully described yet. In this study, we characterize the rheology of human mucus using oscillatory and transient tests. Based on the transient tests, we describe the material behavior of mucus under stress and strain loading by mathematical models.
METHODS:
Mucus samples were collected from clinically used endotracheal tubes. For rheological characterization, oscillatory amplitude-sweep and frequency-sweep tests, and transient creep-recovery and stress-relaxation tests were performed. The results of the transient test were approximated using the Burgers model, the Weibull distribution, and the six-element Maxwell model. The three-dimensional microstructure of the tracheobronchial mucus was visualized using scanning electron microscope imaging.
RESULTS:
Amplitude-sweep tests showed storage moduli ranging from 0.1 Pa to 10000 Pa and a median critical strain of 4 %. In frequency-sweep tests, storage and loss moduli increased with frequency, with the median of the storage modulus ranging from 10 Pa to 30 Pa, and the median of the loss modulus from 5 Pa to 14 Pa. The Burgers model approximates the viscoelastic behavior of tracheobronchial mucus during a constant load of stress appropriately (R2 of 0.99), and the Weibull distribution is suitable to predict the recovery of the sample after the removal of this stress (R2 of 0.99). The approximation of the stress-relaxation test data by a six-element Maxwell model shows a larger fit error (R2 of 0.91).
CONCLUSIONS:
This study provides a detailed description of all process steps of characterizing the rheology of tracheobronchial mucus, including sample collection, microstructure visualization, and rheological investigation. Based on this characterization, we provide mathematical models of the rheological behavior of tracheobronchial mucus. These can now be used to simulate mucus flow in the respiratory system through numerical approaches.