Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium
Refine
Document Type
- Article (42)
- conference proceeding (article) (1)
- conference talk (1)
Is part of the Bibliography
- no (44)
Keywords
- Biomechanik (3)
- AnyBody (2)
- Biomechanics (2)
- Breast augmentation (2)
- Deep drawing (2)
- ECMO (2)
- Multibody dynamics (2)
- Plate heat exchanger (2)
- Simulation (2)
- simulation (2)
Institute
- Fakultät Maschinenbau (44) (remove)
Begutachtungsstatus
- peer-reviewed (43)
Im Betrieb von Förderbändern auftretende Phänomene sind das Bandwandern in Achsrichtung der Walzen und die Bandverformung in der Bandebene [1, S. 142]. Das Bandwandern ist bisher detailliert untersucht [2–4], während die Bandverformung Gegenstand weniger Veröffentlichungen ist. Deshalb wird in diesem Artikel eine Methode zur Berechnung der sich im dynamischen Betrieb einstellenden Verformung eines elastischen Förderbandes vorgestellt. Dazu wird ein Mehrkörpersimulations-Modell basierend auf der Lumped-Mass-Modellierung verwendet. Als Untersuchungsbeispiel dient ein Zwei-Walzensystem mit flexiblen und zylindrischen Walzen, sowie ein flexibles Förderband. Es zeigt sich, dass mit der Lumped-Mass-Modellierung eine dynamische Bandverformung, die von der gewählten Diskretisierung abhängt, berechnet werden kann. Aufgrund dieser Abhängigkeit ist es notwendig eine Konvergenzanalyse durchzuführen. Zusätzlich ist darauf zu achten, dass die künstliche Anregung aufgrund der Lumped-Mass-Modellierung nicht mit einer Eigenfrequenz des Modells zusammenfällt.
Generative deep learning approaches for the design of dental restorations: A narrative review
(2024)
Objectives:
This study aims to explore and discuss recent advancements in tooth reconstruction utilizing deep learning (DL) techniques. A review on new DL methodologies in partial and full tooth reconstruction is conducted.
Data/Sources:
PubMed, Google Scholar, and IEEE Xplore databases were searched for articles from 2003 to 2023.
Study selection:
The review includes 9 articles published from 2018 to 2023. The selected articles showcase novel DL approaches for tooth reconstruction, while those concentrating solely on the application or review of DL methods are excluded. The review shows that data is acquired via intraoral scans or laboratory scans of dental plaster models. Common data representations are depth maps, point clouds, and voxelized point clouds. Reconstructions focus on single teeth, using data from adjacent teeth or the entire jaw. Some articles include antagonist teeth data and features like occlusal grooves and gap distance. Primary network architectures include Generative Adversarial Networks (GANs) and Transformers. Compared to conventional digital methods, DL-based tooth reconstruction reports error rates approximately two times lower.
Conclusions:
Generative DL models analyze dental datasets to reconstruct missing teeth by extracting insights into patterns and structures. Through specialized application, these models reconstruct morphologically and functionally sound dental structures, leveraging information from the existing teeth. The reported advancements facilitate the feasibility of DL-based dental crown reconstruction. Beyond GANs and Transformers with point clouds or voxels, recent studies indicate promising outcomes with diffusion-based architectures and innovative data representations like wavelets for 3D shape completion and inference problems.
Clinical significance:
Generative network architectures employed in the analysis and reconstruction of dental structures demonstrate notable proficiency. The enhanced accuracy and efficiency of DL-based frameworks hold the potential to enhance clinical outcomes and increase patient satisfaction. The reduced reconstruction times and diminished requirement for manual intervention may lead to cost savings and improved accessibility of dental services.
Transient surrogate modeling of modally reduced structures with discontinuous loads and damping
(2024)
In this work, a surrogate model for structural, transient and discontinuously excited finite element method simulations is developed. This allows to reduce the computational effort of repeated calculations of identical models under different load cases. The architecture of the surrogate combines fully connected neural network layers with long short-term memory layers. For the reproduction of different damping ratios, a categorical variable is added to the continuous input data. Based on a recursive flow of the predicted data back to the input layer, long-term dependencies do not vanish due to short-input sequences. The system dimension is reduced by applying the model-order reduction technique for modal decomposition. The high accuracy of the surrogate and the reduction of computational costs are shown on an academic example of a cantilever beam and a real-world example of a robot. The advantages of our approach are illustrated in comparison with state-of-the-art surrogates for transient finite element analysis. By using the surrogate proposed in this study, oscillations due to discontinuous excitation of mechanical structures can be reproduced. For this purpose, only short-input sequences are necessary since the excitation of the oscillations does not have to be part of the input sequence during the whole duration of the oscillations. Due to the categorical variable for the damping ratio, the surrogate can account for the influence of different damping in parameter studies.
AbstractRegularized static friction models have been used successfully for many years. However, they are unable to maintain static friction in detail. For this reason, dynamic friction models have been developed and published in the literature. However, commercial multibody simulation packages such as Adams, RecurDyn, and Simpack have developed their own specific stick-slip models instead of adopting one of the public domain approaches. This article introduces the fundamentals of these commercial models and their behavior from a practical point of view. The stick-slip models were applied to a simple test model and a more sophisticated model of a festoon cable system using their standard parameters.
The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes.
Increasingly stringent emission limits have made particulate filters necessary for gasoline engines. Similar to diesel applications, gasoline particulate filters (GPFs) can be monitored by differential pressure measurement or by the radio-frequency-based filter diagnosis (RF sensor). In addition to measuring the soot loading, ash detection is critical for monitoring the GPF over the entire vehicle lifetime. Because the RF sensor detects the filter loading through a change in the dielectric properties of the GPF, it can detect not only soot but also ash. In diesel applications, the RF sensor has already demonstrated its potential for ash detection. To verify the feasibility of simultaneous ash and soot monitoring for GPFs, filters were loaded with ash on an engine test bench and measured on a lab test bench under defined synthetic exhaust gas conditions. By evaluating resonant modes, soot and ash could be clearly distinguished, as ash mainly affects the resonant frequency, while soot also changes the quality factor due to its high dielectric losses. However, higher soot loadings could not be detected by the resonant parameters, but instead by a frequency-averaged transmission signal. While the presence of ash caused an offset in this signal, its sensitivity to soot was not affected. Thus, the influence of ash can be corrected if the signal in the soot-free filter state is known, e.g., from the behavior of the resonant parameters. Therefore, even with a continuously increasing ash loading over the lifetime of a vehicle, an accurate soot detection is possible with the RF sensor.
In fatigue strength assessment, the methods based on ideal elastic stresses according to Basquin and the less established method based on elastic-plastic stress quantities according to Manson, Coffin and Morrow are applied. The former calculates loads using linear-elastic stresses, the latter requires elasticplastic evaluation parameters, such as stresses and strains. These can be determined by finite element analysis (FEA) with a linear-elastic constitutive law, and subsequent conversion to elastic-plastic loads, using the macro support formula by Neuber. In this contribution, an alternative approach to approximate elastic-plastic parameters proposed by Glinka is compared to the the strain-life method using Neuber's formula, as well as the stress-life method of Basquin. Several component tests on 42CrMoS4-QT specimens are investigated. To determine the input data for the fatigue strength evaluations, the entire test setup is computed by FEA. The nodal displacements from these validated full-model simulations are used as boundary conditions for a submodel simulation of a notch, whose results serve as input for the fatigue strength assessments. It is shown that all approaches provide a reliable assessment of components. Our key result is that the strain-life method using the concept by Glinka for notch stress computation, yields improved results in fatigue strength assessments.
Although magnesium and its alloys are promising candidates as biodegradable implant materials, the tendency for localized corrosion mechanism in physiological environment limit their biomedical application. Electropolishing is an attractive strategy for improving the corrosion behaviour of metals, but it is still largely unexplored in magnesium materials. In this study, the characterization of electropolished surfaces of AM50 and pure magnesium was performed, focussing on their in vitro degradation behaviour in cell medium. Corrosion rates were evaluated using potentiodynamic polarisation. The surface morphology before and after the onset of corrosion was investigated by scanning electron microscopy and confocal laser scanning microscopy. The presented electropolishing process led to improved surface performances, observable by significantly lower corrosion rates (0.08 mm·year-1 in Dulbecco's modified Eagle's medium), lower arithmetical mean height (0.05 µm), lower water contact angle (25-35°) and lower micro hardness (35-50 HV 0.1) compared to mechanically and chemically treated surfaces. MgO/Mg(OH)2 could be detected on electropolished surfaces. The localized corrosion mode could be reduced, but not entirely prevented. Electropolishing shows great potential as post-treatment of magnesium-based components, but detailed tests of the long-term corrosion behaviour are an important area of future research.
Review of elasto-static models for three-dimensional analysis of thick-walled anisotropic tubes
(2023)
Most shell or beam models of anisotropic tubes under bending have no validity for thick-walled structures. As a result, the need to develop three-dimensional formulations which allow a change in the stress, strain and displacement distributions across the radial component arises. Basic formulations on three-dimensional anisotropic elasticity were made either stressor displacement-based by Lekhnitskii or Stroh on plates. Lekhnitskii also was the first to expand these analytical formulations to tubes under various loading conditions. This paper presents a review of the stress and strain analysis of tube models using three-dimensional anisotropic elasticity. The focus lies on layered structures, like fiber-reinforced plastics, under various bending loads, although the basic formulations and models regarding axisymmetric loads are briefly discussed. One section is also dedicated to the determination of an equivalent bending stiffness of tubes.
BACKGROUND: Thrombosis remains a critical complication during venovenous extracorporeal membrane oxygenation (VV ECMO). The involvement of neutrophil extracellular traps (NETs) in thrombogenesis has to be discussed. The aim was to verify NETs in the form of cell-free DNA (cfDNA) in the plasma of patients during ECMO.
METHODS: A fluorescent DNA-binding dye (QuantifFluor®, Promega) was used to detect cell-free DNA in plasma samples. cfDNA concentrations from volunteers (n = 21) and patients (n = 9) were compared and correlated with clinical/technical data before/during support, ECMO end and time of a system exchange.
RESULTS: Before ECMO, patients with a median (IQR) age of 59 (51/63) years, SOFA score of 11 (10/15), and ECMO run time of 9.0 (7.0/19.5) days presented significantly higher levels of cfDNA compared to volunteers (6.4 (5.8/7.9) ng/μL vs. 5.9 (5.4/6.3) ng/μL; p = 0.044). Within 2 days after ECMO start, cfDNA, inflammatory, and hemolysis parameters remained unchanged, while platelets decreased (p = 0.005). After ECMO removal at the end of therapy, cfDNA, inflammation, and coagulation data (except antithrombin III) remained unchanged. The renewal of a system resulted in known alterations in fibrinogen, d-dimers, and platelets, while cfDNA remained unchanged.
CONCLUSION: Detection of cfDNA in plasma of ECMO patients was not an indicator of acute and circuit-induced thrombogenesis.