Produktion und Systeme
Refine
Year of publication
- 2016 (5) (remove)
Document Type
Language
- English (5)
Has Fulltext
- no (5)
Is part of the Bibliography
- no (5)
Keywords
- BEHAVIOR (2)
- DEPENDENCE (2)
- HOMOGENEOUS MAGNETIC-FIELD (2)
- AMPLITUDE (1)
- Deformation (1)
- FERROGELS (1)
- FLUID (1)
- Formgedächtniseffekt (1)
- Image processing (1)
- Kompositwerkstoff (1)
Institute
- Fakultät Elektro- und Informationstechnik (5) (remove)
Begutachtungsstatus
- peer-reviewed (2)
Magneto-active Polymers (MAP) are closely related to magneto-rheological fluids in that they contain magnetic micro-particles. However, instead of being freely suspended in a carrier fluid they are physically bound within a highly elastic polymer-matrix. The application of an external magnetic field allows changes in the mechanical properties, such as elastic and shear moduli, of the composite material to be achieved. The colossal magneto-rheological effect has been shown to demonstrate changes in Young's modulus by over 1E6 %. Current research concentrates on controllable compliance and the resulting shape memory properties of MAP. This paper deals with recent advancements in this respect, including tubular magneto-active devices with potential applications in medical and other technology.
Magnetoactive elastomers (MAEs) are composite materials comprised of micrometer-sized ferromagnetic particles in a nonmagnetic elastomermatrix. Asingle-particle mechanism ofmagnetostriction in MAEs, assuming the rotation of a soft magnetic, mechanically rigid particle with uniaxial magnetic anisotropy in magnetic fields is identified and considered theoretically within the framework of an alternative model. In this mechanism, the total magnetic anisotropy energy of the filling particles in the matrix is the sum over single particles. Matrix displacements in the vicinity of the particle and the resulting direction of the magnetization vector are calculated. The effect of matrix deformation is pronounced well if the magnetic anisotropy coefficient K is much larger than the shear modulus mu of the elastic matrix. The feasibility of the proposed magnetostriction mechanism in soft magnetoactive elastomers and gels is elucidated. The magnetic-field-induced internal stresses in the matrix lead to effects of magnetodeformation and may increase the elastic moduli of these composite materials.
Transient magnetorheological response of magnetoactive elastomers to step and pyramid excitations
(2016)
Transient rheological response of magnetoactive elastomers is experimentally studied using dynamic torsion at a fixed oscillation frequency in temporally stepwise changing magnetic fields and oscillation amplitudes. For step magnetic-field excitations, at least three exponential functions are required to reasonably describe the time behavior of the storage shear modulus over long time scales (>10(3) s). The deduced characteristic time constants of the corresponding rearrangement processes of the filler network differ approximately by one order of magnitude: tau(1) less than or similar to 10(1) s, tau(2) similar to 10(2) s, and tau(3) similar to 10(3) s. The sudden imposition of the external magnetic field activates a very fast rearrangement process with the characteristic time under 10 s, which cannot be determined more precisely due to the measurement conditions. Even more peculiar transient behavior has been observed during pyramid excitations, when either the external magnetic field was first stepwise increased and then decreased in a staircase manner at a fixed strain amplitude gamma or the strain amplitude gamma was first stepwise increased and then decreased in a staircase manner at a fixed magnetic field. In particular, the so-called "cross-over effect'' has been identified in both dynamical loading programs. This cross-over effect seems to be promoted by the application of the external magnetic field. The experimental results are discussed in the context of the specific rearrangement of the magnetic filler network under the simultaneous action of the external magnetic field and shear deformation. Striking similarities of the observed phenomena to the structural relaxation processes in glassy materials and to the jamming transition of granular materials are pointed out. The obtained results are important for fundamental understanding of material behavior in magnetic fields as well as for the development of devices on the basis of magnetoactive elastomeric materials.
The surface dilational modulus is a crucial parameter for describing the rheological properties of aqueous surfactant solutions. These properties are important for many technological processes. The present paper describes a fully automated instrument based on the oscillating bubble technique. It works in the frequency range from 1 Hz to 500 Hz, where surfactant exchange dynamics governs the relaxation process. The originality of instrument design is the consistent combination of modern measurement technologies with advanced imaging and signal processing algorithms. Key steps on the way to reliable and precise measurements are the excitation of harmonic oscillation of the bubble, phase sensitive evaluation of the pressure response, adjustment and maintenance of the bubble shape to half sphere geometry for compensation of thermal drifts, contour tracing of the bubbles video images, removal of noise and artefacts within the image for improving the reliability of the measurement, and, in particular, a complex trigger scheme for the measurement of the oscillation amplitude, which may vary with frequency as a result of resonances. The corresponding automation and programming tasks are described in detail. Various programming strategies, such as the use of MATLAB (R) software and native C++ code are discussed. An advance in the measurement technique is demonstrated by a fully automated measurement. The instrument has the potential to mature into a standard technique in the fields of colloid and interface chemistry and provides a significant extension of the frequency range to established competing techniques and state-of-the-art devices based on the same measurement principle.