Produktion und Systeme
Refine
Year of publication
- 2012 (9) (remove)
Document Type
- Article (4)
- conference proceeding (article) (4)
- Report (1)
Has Fulltext
- no (9)
Is part of the Bibliography
- no (9)
Keywords
Institute
- Fakultät Elektro- und Informationstechnik (9) (remove)
Begutachtungsstatus
- peer-reviewed (4)
PPG signal acquisition and analysis on in vitro tooth model for dental pulp vitality assessmen
(2012)
A method of referencing in an extrinsic optical fiber sensor system utilizing temperature dependence of the absorption edge in a semiconductor crystal (semi-insulating iron-doped indium phosphide) is demonstrated. The intensity reference is provided by controlling the temperature of an LED source and transmission measurements with different emission spectra. A transient operation regime is introduced. The entire process is controlled by a microprocessor unit. The performance of the sensor system is investigated and it is shown that the connector losses may be compensated for. Contrary to the published works performed with GaAs crystals it was not observed that the absorption coefficient of the semiconductor follows the law for idealized direct-gap semiconductor but can be described by the so-called Urbach tail. Since the proposed sensor system comprises a single LED source, simple electronics and no optical fiber couplers it is promising for realization of low-cost fiber-optic temperature sensors, e.g. for power transformer monitoring or magnetic resonance imaging applications.
The characteristics of both direct and converse magnetoelectric (ME) interactions in bilayer composite structures comprising layers of a commercially available magnetostrictive permendur CoFe alloy and different piezoelectric PZT ceramics are investigated in detail by the method of harmonic field modulation. It is shown that, given the optimum DC magnetic bias field, a high piezomagnetic coefficient in the alloy leads to increased efficiency of ME interactions. The resonant behavior of frequency dependencies of the magnetoelectric voltage is explained by excitation of bending and planar mechanical oscillations in the structures. The results are of interest for developing highly sensitive AC magnetic field sensors and magnetoelectric transducers for energy harvesting from mechanical vibrations.
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated over a wide spectral range, from visible to terahertz (THz) light. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
The Trilopede
(2012)
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated. The measurements carried out over a wide spectral range, from visible light down to terahertz radiation. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
The magnetoelectric response of bi- and symmetric trilayer composite structures to pulsed magnetic fields is experimentally investigated in detail. The structures comprise layers of commercially available piezoelectric (lead zirconate titanate) and magnetostrictive (permendur or nickel) materials. The magnetic-field pulses have the form of a half-wave sine function with duration of 450 µs and amplitudes ranging from 500 Oe to 38 kOe. The time dependence of the resulting voltage is presented and explained by theoretical estimations. Appearance of voltage oscillations with frequencies much larger than the reciprocal pulse length is observed for sufficiently large amplitudes (~1-10 kOe) of the magnetic-field pulse. The origin of these oscillations is the excitation of bending and planar acoustic oscillations in the structures. Dependencies of the magnetoelectric voltage coefficient on the excitation frequency and the applied magnetic field are calculated by digital signal processing and compared with those obtained by the method of harmonic field modulation. The results are of interest for developing magnetoelectric sensors of pulsed magnetic fields as well as for rapid characterization of magnetoelectric composite structures.
A detailed experimental study of the magnetoelectric response of planar bi- and symmetric trilayer composite structures to magnetic field pulses is reported. The structures consist of layers of commercially available piezoelectric (lead zirconate titanate) and magnetostrictive (permendur or nickel) materials. The magnetic-field pulses have the form of a half-wave sine function with duration of 450 μs and amplitude from 500 Oe up to 38 kOe. The measurement method is explained and the measured time dependence of the resulting voltage is presented. The most interesting case, when pulse amplitudes are sufficiently large (~ 1-10 kOe) and various types of acoustic oscillation with frequencies much larger than the reciprocal pulse length are excited in the structures, is considered. The dependencies of the magnetoelectric voltage coefficient on the excitation frequency and the applied magnetic field are calculated. By digital signal processing the results are compared with those obtained by the method of harmonic field modulation (HFM). The findings are of interest for developing magnetoelectric sensors for pulsed magnetic fields as well as for rapid characterization of magnetoelectric composite structures.