Two analytical methods based on the so-called local linearization of magnetostatic properties of composite materials with ferromagnetic inclusions in a non-magnetic matrix are described. These methods are applied to the experimental data obtained in Gorkunov et al. [Russ. J. Nondestruct. Test. 3 (2001) 186]. A qualitative agreement is obtained for the concentration values reported in that paper and a quantitative agreement is achieved at slightly different value of concentration. The conclusions are supported by direct numerical modeling.
Application of Magnetic Garnet Films for Magnetooptical Imaging of Magnetic Field Distributions
(2004)
Rare-earth iron garnet films of high quality can be grown by liquid phase epitaxy on paramagnetic substrates of gadolinium galliumgarnet. Such films are currently used for imaging of the spatial distribution of magnetic fields. This application is based on the Faraday rotation which can strongly be enhanced by bismuth incorporation.
The physical properties of the films can be controlled by the chemical composition, the growth conditions and the crystallographic orientation. The sensor properties like sensitivity, dynamic range, signal linearity and unambiguity must be optimized according to the application desired. These properties, however, are not independent of each other. In addition, they strongly depend on the optical wavelength. Thus, it is necessary to find compromises.
The influence of Faraday rotation, Faraday ellipticity, optical absorption, magnetic anisotropies and film thickness on the performance of a magnetooptical indicator film is investigated. Based on the swing of the photoresponse, a new optimization process is introduced. The process is experimentally verified and application examples are demonstrated.
Furthermore, two methods are presented to enhance the sensitivity of magnetooptical sensors. Using specific crystallographic orientations, an easy plane of magnetization can be induced which is inclined with respect to the film plane. If the magnetization lies in this plane a very high sensitivity is achieved. The dependence of the geometrical orientation of the easy plane on the growth direction is calculated and the sensitivity and dynamic range are derived. Experimental results of a [112] oriented garnet film are in good agreement with calculations.
Garnet films which are magnetized along the film normal due to a strong induced uniaxial anisotropy support magnetic domains. If the collapse field perpendicular to the film plane is small, such films can be used as very sensitive indicator films. Such films are easier to prepare than sensitive in-plane films. However, the spatial resolution is limited by the size of the domains. This disadvantage can be avoided by applying a bias field in the film plane. Directly at the in-plane collapse field the sensor film is in-plane magnetized yielding high spatial resolution at still high sensitivity. The variation of magnetooptical images with in-plane induction is demonstrated. Experimental results are in agreement with calculations.
Resonant frequencies of a split-ring resonator: Analytical solutions and numerical simulations
(2004)
A set of differential equations describing the current andvoltage distribution in a split-ring resonator is derived and solved ana-lytically. The resonant frequencies may be obtained from the solution of a characteristic equation. An approximate solution for the lowest reso-nant frequency agrees with that obtained by heuristic arguments. The analytical results are supported by numerical simulations
An equivalent circuit, consisting of bulk and distributed elements, is derived for describing the properties of a potential metamaterial element capable of providing negative effective permeability. It is the singly split double ring (SSDR), a special case of the split ring resonator (J. B. Pendry et al., IEEE Trans. Microwave Theory Tech. 47, 2075 (1999)), obtained when the gap capacitance in the inner ring is infinitely large. The variables are the inter-ring voltage and the currents flowing in the inner and outer rings. The excitation is assumed in the form of a spatially constant temporally varying magnetic field. The functions, showing the angular variation of the variables, are found by solving a set of differential equations with boundary conditions imposed at the position of the split. It is shown from the analytical solution that the SSDR can have resonant frequencies in the full spectrum from very low to very high frequencies. It is pointed out in particular that whenever the mean diameter of the ring is equal to an odd multiple of the half wavelength it is always possible to find a set of parameters which will give rise to resonance. As examples the resonant frequencies are determined for eight sets of parameters. Results are also derived by replacing the distributed circuit with a number of discrete circuits. It is finally shown that the results obtained from the equivalent circuit model are in excellent agreement with those derived from the MICRO-STRIPES numerical package which solves Maxwell’s equations in the time domain.
Robotergreifer
(2004)
Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. Malignant tumors are significantly stiffer and more immobile than surrounding healthy tissue. Hard calcifications in vessels occur due to arteriosclerosis. The problem is, that such information is usually not available or can only be obtained by manual palpation, which is subjective and limited in sensitivity. It requires intuitive assessment and does not allow quantitative documentation. Unfortunately, none of the established medical imaging equipment such as magnetic resonance imaging (MRI) or X-ray computed tomography (CT) can provide direct measure of tissue elasticity. On the one hand a suitable sensor is required for quantitative measurement of mechanical tissue properties. On the other hand there is also some need for a realistic haptic display of such tissue properties. Suitable actuator arrays with high spatial resolution acting in real time are required. A haptic sensor actuator system is presented in this paper including a sensitive sensor part and an actuator array for different applications. The mechanical consistency of an object is to be locally specified using a sensor system and represented perceptibly in a remote position on an actuator system for the user. The sensor system uses ultrasound (US) elastography, whereas the actuator array is based on electrorheological (ER) fluids.
Reduction of femoral shaft fractures in vitro by a new developed reduction robot system "RepoRobo"
(2004)
Closed reduction of the long bones is associated with the use of
considerable force. This force must be maintained for the reduction maneuver and fixation process. At present, apart from the extension table or the large AO distractor, only rather inadequate reduction aids are available. A solution to this problem is being sought in the form of a robotic system with which precision can be improved and the holding effort reduced. In the research project presented here, a synthetic femur with integrated tensioned mainspring and a 32-A3 type
fracture served as a bone reduction model. The fracture was stabilized with a standard AO fixator. A Stäubli robot (model RX130) was converted by appropriate modification so that it could be used for the reduction of femoral shaft fractures in vitro. The robot was equipped with a pneumatic 2-fingered gripper, on which the fingers have
been modified so that they can grip the AO fixator clamp. A Force-Feedback-Sensor was inserted between the gripper and the robot to obtain online recordings of the forces and moments in all three axes. With this setup it is possible to achieve precise reduction of the fracture in all planes under visual control.
This paper reports the first step in the development of a tactile array suitable for the presentation of haptic information in virtual reality. The system is based on the electric field dependence of the viscosity of electrorheological fluids. The simulation, as well as the experimental realization of single tactels is described. The mathematical approach is based on the Eckart model (Eckart W 2000 Continuum Mech. Thermodyn. 12 341–62) and its validity is demonstrated by comparing the resulting yield stress with the experimental results from Wunderlich (2000 Dissertation Universität Erlangen-Nürnberg). Two different tactel designs are realized and the experimental results are compared with numerical simulation. The design of modification B is shown to be applicable for the realization of an actuator array with high spatial resolution.
The application of robotics in manufacturing industry is increasingly spreading to other fields such as service, security and medical, and more recently into orthopedic surgery. Most research projects to date have concentrated on the lighter side of non‐invasive surgery, camera, laser guidance, light cutting and milling through bone. Just as in industrial production and processing applications, the choice of robot and its accompanying control and programming system is absolutely paramount. This simple fact has been justified in recent research dealing with the heavier forms of fracture repositioning robotics in accident surgery. This paper discusses the development of the complete system including robot, end‐effector and sensors.