Smart materials change their properties with external energy supply. Besides the known ferro-fluids and Magneto Rheological Fluid (MRF) also the Electro Active Polymer (EAP) and Magneto Rheological Elastomer (MRE) belong to these intelligent materials. The latest generation of magnetic elastomers represents a new class of composite materials. This consists of small magnetized particles which are sized in the micron or even nanometer range that in turn is bounded in a highly elastic rubber matrix. These materials are very often called MRE. Only recently, it has managed to develop these materials even further, so that very soft composite materials with a young?s modulus up to 10 kPa are possible. These soft polymers could be named magneto-active polymers. The combination of polymers with magnetic materials show novel and often enhanced properties. A precisely controllable young?s modulus and hardness, giant and non-homogeneous deformation behavior and rapid response to the magnetic field opens up new possibilities for various applications. Since MAP represent a very new technology, the behavior of these materials as a function of their composition and external conditions so far are not yet sufficiently understood. Therefore, some fundamental studies are necessary. In this paper, the mechanical surface properties are studied using a micro hardness meter. This work shows the possibility to control mechanical properties at the surface of MAP with new developed magnetic systems.
Der Roboter als Hilfsmittel in der Chirurgie // International Mechatronik Forum, Linz, October 2006
(2006)
PPG signal acquisition and analysis on in vitro tooth model for dental pulp vitality assessmen
(2012)
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated over a wide spectral range, from visible to terahertz (THz) light. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
The Trilopede
(2012)
Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication.
Robotergreifer
(2004)
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated. The measurements carried out over a wide spectral range, from visible light down to terahertz radiation. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
Mechanical cues such as extracellular matrix stiffness and movement have a major impact on cell differentiation and function. To replicate these biological features in vitro, soft substrata with tunable elasticity and the possibility for controlled surface translocation are desirable. Here we report on the use of ultra-soft (Young’s modulus <100 kPa) PDMS-based magnetoactive elastomers (MAE) as suitable cell culture substrata. Soft non-viscous PDMS (<18 kPa) is produced using a modified extended crosslinker. MAEs are generated by embedding magnetic microparticles into a soft PDMS matrix. Both substrata yield an elasticity-dependent (14 vs. 100 kPa) modulation of α-smooth muscle actin expression in primary human fibroblasts. To allow for static or dynamic control of MAE material properties, we devise low magnetic field (≈40 mT) stimulation systems compatible with cell-culture environments. Magnetic field-instigated stiffening (14 to 200 kPa) of soft MAE enhances the spreading of primary human fibroblasts and decreases PAX-7 transcription in human mesenchymal stem cells. Pulsatile MAE movements are generated using oscillating magnetic fields and are well tolerated by adherent human fibroblasts. This MAE system provides spatial and temporal control of substratum material characteristics and permits novel designs when used as dynamic cell culture substrata or cell culture-coated actuator in tissue engineering applications or biomedical devices.
Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. Malignant tumors are significantly stiffer and more immobile than surrounding healthy tissue. Hard calcifications in vessels occur due to arteriosclerosis. The problem is, that such information is usually not available or can only be obtained by manual palpation, which is subjective and limited in sensitivity. It requires intuitive assessment and does not allow quantitative documentation. Unfortunately, none of the established medical imaging equipment such as magnetic resonance imaging (MRI) or X-ray computed tomography (CT) can provide direct measure of tissue elasticity. On the one hand a suitable sensor is required for quantitative measurement of mechanical tissue properties. On the other hand there is also some need for a realistic haptic display of such tissue properties. Suitable actuator arrays with high spatial resolution acting in real time are required. A haptic sensor actuator system is presented in this paper including a sensitive sensor part and an actuator array for different applications. The mechanical consistency of an object is to be locally specified using a sensor system and represented perceptibly in a remote position on an actuator system for the user. The sensor system uses ultrasound (US) elastography, whereas the actuator array is based on electrorheological (ER) fluids.
Reduction of femoral shaft fractures in vitro by a new developed reduction robot system "RepoRobo"
(2004)
Closed reduction of the long bones is associated with the use of
considerable force. This force must be maintained for the reduction maneuver and fixation process. At present, apart from the extension table or the large AO distractor, only rather inadequate reduction aids are available. A solution to this problem is being sought in the form of a robotic system with which precision can be improved and the holding effort reduced. In the research project presented here, a synthetic femur with integrated tensioned mainspring and a 32-A3 type
fracture served as a bone reduction model. The fracture was stabilized with a standard AO fixator. A Stäubli robot (model RX130) was converted by appropriate modification so that it could be used for the reduction of femoral shaft fractures in vitro. The robot was equipped with a pneumatic 2-fingered gripper, on which the fingers have
been modified so that they can grip the AO fixator clamp. A Force-Feedback-Sensor was inserted between the gripper and the robot to obtain online recordings of the forces and moments in all three axes. With this setup it is possible to achieve precise reduction of the fracture in all planes under visual control.
Piezoelectric actuators are well established for use in expensive optical equipment. Within the last decade, relatively inexpensive piezoelectric actuators have become established technology in pneumatic switching and the first piezoelectrically driven impactive robot grippers are just starting to emerge. Although this article concentrates largely on the use of piezoelectric actuators for use in robot gripping systems, the potential for applications outside this field is immense.
Shape memory materials fulfill an important role in both actuation and mechanical coupling between actuators and associated dynamic systems. The simplest techniques are thermally based and in addition to the more common shape memory alloys there are also shape memory polymers. These have similar characteristics to those of their metallic cousins, but there the relationship stops. The basic physical principles are very different and this paper attempts to outline the current state-of-the-art to those already involved with the technology and perhaps open a fresh chapter in smart materials to those who are new to it.
This paper reports the first step in the development of a tactile array suitable for the presentation of haptic information in virtual reality. The system is based on the electric field dependence of the viscosity of electrorheological fluids. The simulation, as well as the experimental realization of single tactels is described. The mathematical approach is based on the Eckart model (Eckart W 2000 Continuum Mech. Thermodyn. 12 341–62) and its validity is demonstrated by comparing the resulting yield stress with the experimental results from Wunderlich (2000 Dissertation Universität Erlangen-Nürnberg). Two different tactel designs are realized and the experimental results are compared with numerical simulation. The design of modification B is shown to be applicable for the realization of an actuator array with high spatial resolution.
The application of robotics in manufacturing industry is increasingly spreading to other fields such as service, security and medical, and more recently into orthopedic surgery. Most research projects to date have concentrated on the lighter side of non‐invasive surgery, camera, laser guidance, light cutting and milling through bone. Just as in industrial production and processing applications, the choice of robot and its accompanying control and programming system is absolutely paramount. This simple fact has been justified in recent research dealing with the heavier forms of fracture repositioning robotics in accident surgery. This paper discusses the development of the complete system including robot, end‐effector and sensors.
The magnetoelectric response of bi- and symmetric trilayer composite structures to pulsed magnetic fields is experimentally investigated in detail. The structures comprise layers of commercially available piezoelectric (lead zirconate titanate) and magnetostrictive (permendur or nickel) materials. The magnetic-field pulses have the form of a half-wave sine function with duration of 450 µs and amplitudes ranging from 500 Oe to 38 kOe. The time dependence of the resulting voltage is presented and explained by theoretical estimations. Appearance of voltage oscillations with frequencies much larger than the reciprocal pulse length is observed for sufficiently large amplitudes (~1-10 kOe) of the magnetic-field pulse. The origin of these oscillations is the excitation of bending and planar acoustic oscillations in the structures. Dependencies of the magnetoelectric voltage coefficient on the excitation frequency and the applied magnetic field are calculated by digital signal processing and compared with those obtained by the method of harmonic field modulation. The results are of interest for developing magnetoelectric sensors of pulsed magnetic fields as well as for rapid characterization of magnetoelectric composite structures.
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated. The measurements carried out over a wide spectral range, from visible light down to terahertz radiation. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
The concept and some steps in the development of a new actuator system which enables the haptic perception of mechanically inhomogeneous virtual objects are introduced. The system consists of a two-dimensional planar array of actuator elements containing an electrorheological (ER) fluid. When a user presses his fingers onto the surface of the actuator array, he perceives locally variable resistance forces generated by vertical pistons which slide in the ER fluid through the gaps between electrode pairs. The voltage in each actuator element can be individually controlled by a novel sophisticated switching technology based on optoelectric gallium arsenide elements. The haptic information which is represented at the actuator array can be transferred from a corresponding sensor system based on ultrasonic elastography. The combined sensor-actuator system may serve as a technology platform for various applications in virtual reality, like telemedicine where the information on the consistency of tissue of a real patient is detected by the sensor part and recorded by the actuator part at a remote location.
The use of ultrasound systems for medical examination and diagnosis is nothing new. The extension of ultrasound techniques for real time elastographic analysis purposes represents a more recent development. Nevertheless, as they stand all such techniques rely on the interpretation of two-dimensional visual data displayed on a video screen. In reality however, a medical doctor will make as much use of exploratory touch as he or she does vision, making the simultaneous portrayal of both video and tactile information most desirable [Böse H, Monkman GJ, Freimuth H, Ermert H. Haptisches Sensor-Aktor-System uaf der grundlage der Echtzeitelastographie sowie von elktro- und magnetorheologischen Materialien “HASASEM” [3]. BMBF Antrag 01 IR A14D, Oktober 2000].
This paper discusses the preliminary tests and basic design parameters for single tactels using electrorheological fluids. The final aim is to produce a prototype three-dimensional tactile display comprising electrically switchable micro-machined cells whose mechanical moduli are governed by phase changes experienced by electrorheological fluids. This will be integrated with the latest elastographic ultrasonic sensor systems in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone.
The ability to image the elastic properties of tissue is potentially useful in a variety of applications. The field of elastic imaging has grown in response to the Potential use of such information in medical diagnosis. Real time ultrasound elastography represents a recent development in determining strain and elasticity distributions. Nevertheless, commonly used imaging techniques rely on the interpretation of two dimensional visual data displayed on a video screen. In reality however, physicians often prefer tactile exploration making the simultaneous portrayal of both video and haptic information most desirable.
Since the 1970's many alphanumeric to tactile data conversion methods have been investigated, mainly with the ultimate aim of assisting the blind. More recently, interest has been directed toward the display of pictures on haptically explorable surfaces - Tactile imaging. Such a system would allow surgeons to examine hard sectors contained within soft tissue, and thereby assist in operations held remotely. The expansion of ultrasound elastography to 3D formats would mean the ability to haptically explore regions of the body normally inaccessible to human hands. For three-dimensional imaging the acquisition of sequential tomographic slices using Elastography, combined with image segmentation, enables the reconstruction, quantification and visualisation of tumour volumes.
In a collaborative project between four research Institutes, the aim is to produce a prototype three dimensional tactile displays comprising electrically switchable micromachined cells, whose mechanical moduli are governed by phase changes experienced by electrorheological and/or magnetorheological fluids. This will be integrated with a sensory ultrasonic elastography in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone.
A detailed experimental study of the magnetoelectric response of planar bi- and symmetric trilayer composite structures to magnetic field pulses is reported. The structures consist of layers of commercially available piezoelectric (lead zirconate titanate) and magnetostrictive (permendur or nickel) materials. The magnetic-field pulses have the form of a half-wave sine function with duration of 450 μs and amplitude from 500 Oe up to 38 kOe. The measurement method is explained and the measured time dependence of the resulting voltage is presented. The most interesting case, when pulse amplitudes are sufficiently large (~ 1-10 kOe) and various types of acoustic oscillation with frequencies much larger than the reciprocal pulse length are excited in the structures, is considered. The dependencies of the magnetoelectric voltage coefficient on the excitation frequency and the applied magnetic field are calculated. By digital signal processing the results are compared with those obtained by the method of harmonic field modulation (HFM). The findings are of interest for developing magnetoelectric sensors for pulsed magnetic fields as well as for rapid characterization of magnetoelectric composite structures.
Robot Grippers
(2006)
Since robotic prehension is widely used in all sectors of manufacturing industry, this book fills the need for a comprehensive, up-to-date treatment of the topic. As such, this is the first text to address both developers and users, dealing as it does with the function, design and use of industrial robot grippers. The book includes both traditional methods and many more recent developments such as micro grippers for the optolectronics industry. Written by authors from academia, industry and consulting, it begins by covering the four basic categories of robotic prehension before expanding into sections dealing with endeffector design and control, robotic manipulation and kinematics. Later chapters go on to describe how these various gripping techniques can be used for a common industrial aim, with details of related topics such as: kinematics, part separation, sensors, tool excahnge and compliance. The whole is rounded off with specific examples and case studies. With more than 570 figures, this practical book is all set to become the standard for advanced students, researchers and manufacturing engineers, as well as designers and project managers seeking practical descriptions of robot endeffectors and their applications.
Since the 1960s many alphanumeric to tactile data conversion methods have been investigated, mainly with the ultimate aim of assisting the blind. More recently, interest has been directed toward the display of pictures on haptically explorable surfaces – tactile imaging – for a range of medical, remote sensing and entertainment purposes. This paper examines the technologies which have been utilised for haptically explorable tactile displays over the past three decades, focussing on those which appear commercially viable in the immediate future.
Evaluation of highly compliant magneto-active elastomers with colossal magnetorheological response
(2014)
Highly compliant elastomers with a shear storage modulus as low as 25 Pa are prepared using commercially available silicone, plasticizer, and tactile mutator silicone additive. They are used as matrix material for magneto-active elastomers (MAEs) with carbonyl iron contents between 0 and 85 wt %. In the absence of an external magnetic field, the storage modulus of MAEs based on two selected mixtures ranges between ~100 Pa and ~2000 Pa. Addition of a mutator to the matrix mixture results in a long post-cure period depending on the curing temperature and the initial mixture. In the presence of a magnetic field, the presented MAEs exhibit a strong magneto-induced change in storage modulus resulting in a colossal magnetorheological effect of >106 % which is ~30 times higher than previously reported values. The results are of interest in applications using such elastomers as cell substrates with magnetically tunable rigidity.
A low-cost wax-cast molding technique for structuring ultrasoft (Young’s modulus ≤ 40 kPa), agglutinative magnetorheological elastomer (MRE) material is presented. MRE structures ranging from a few millimeters down to the micrometer range with highly reproducible results are possible. Semitransparent MREs are also fabricated and their surfaces modified accordingly. This method opens new possibilities for MREs in biomedical engineering and microfluidic applications. © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013
Magneto-active Polymers (MAP) are closely related to magneto-rheological fluids in that they contain magnetic micro-particles. However, instead of being freely suspended in a carrier fluid they are physically bound within a highly elastic polymer-matrix. The application of an external magnetic field allows changes in the mechanical properties, such as elastic and shear moduli, of the composite material to be achieved. The colossal magneto-rheological effect has been shown to demonstrate changes in Young's modulus by over 1E6 %. Current research concentrates on controllable compliance and the resulting shape memory properties of MAP. This paper deals with recent advancements in this respect, including tubular magneto-active devices with potential applications in medical and other technology.
Field induced plasticity of magneto-sensitive elastomers for gripping technology applications
(2018)
Hysteresis in dynamic modulus, loss factor and normal forces of magnetoactive elastomers (MAEs) comprising various proportions of small (3-5 mu m) and large (50-60 mu m) ferromagnetic particles are experimentally studied using dynamic torsion performed at a fixed oscillation frequency in varying DC magnetic fields. It is shown that hysteresis is a characteristic feature of MAEs observed both under increasing/decreasing magnetic field strength and increasing/decreasing strain amplitude. This hysteresis is attributed to the specific rearrangement of the magnetic filler network under simultaneously applied magnetic field and shear deformation. Rheological properties of the magnetic filler network formed in the magnetic field and, therefore, the rheological properties of MAEs depend strongly on the filler composition and the magnetic field magnitude. Larger magnetic particles and higher magnetic fields provide stronger magnetic networks. Both factors result in the extension of the linear viscoelastic regime to larger strain amplitudes and lead to higher values of shear storage and loss moduli. It is found that the hysteresis width maximises at an intermediate magnetic field where it is attributed to the balance between elastic and magnetic particle interactions. This is apparently where the most significant restructuring of the magnetic network occurs. The hysteresis width decreases with increasing fraction of large particles in the magnetic filler. The loss factor grows significantly when the magnetic network is physically broken by large strains gamma > 1%. A huge (more than one order of magnitude) increase of normal force at maximum magnetic field strengths is observed. It is predicted that any physical quantity depending on the internal structuring of the magnetic filler should demonstrate hysteresis either with a changing magnetic field and constant deformation amplitude or under variable deformation in a constant magnetic field. (C) 2015 Elsevier Ltd. All rights reserved.
Experimental study of the magnetic field enhanced Payne effect in magnetorheological elastomers
(2014)
The dynamic modulus and the loss factor of magnetorheological elastomers (MREs) of various compositions and anisotropies are studied by dynamic torsion oscillations performed in the absence and in the presence of an external magnetic field. The emphasis is on the Payne effect, i.e. the dependence of the elastomer magnetorheological characteristics on the strain amplitude and their evolution with cyclically increasing and decreasing strain amplitudes. MREs are based on two silicone matrices differing in storage modulus (soft, G' similar to 10(3) Pa, and hard, G' similar to 10(4) Pa, matrices). For each matrix, the concentration of carbonyl iron particles with diameters of 3-5 mu m was equal to 70 and 82 mass% (22 and 35 vol%, respectively) in the composite material. Samples for each filler content, isotropic and aligned-particles, are investigated. It is found that the Payne effect significantly increases in the presence of an external magnetic field and varies with the cyclical loading which reaches saturation after several cycles. The results are interpreted as the processes of formation-destruction-reformation of the internal filler structure under the simultaneously applied mechanical force and magnetic field. Impacts of matrix elasticity and magnetic interactions on the filler alignment are elucidated.
The magnetoactive electret
(2017)
A magnet which adheres to every surface, not only those of ferromagnetic materials, has hitherto been the domain of science fiction. Now for the first time such a novel device exists. The fusion of a permanently magnetized magnetoactive polymer containing hard magnetic particles and an electret enhanced with ferroelectric particles has resulted in the development of a new smart device-the magnetoactive electret. Magnetoactive electrets can be made to exhibit the usual magnetic properties of permanent magnetism together with the electrostatic properties of electrets. This results in simultaneous magnetoadhesion and electroadhesion forces from the same elastomeric element. The biasing field, needed to avoid discontinuities concerned with transition through the zero point in operating curves, is normally provided by means of either a magnetic or an electric field. This novel technology provides both bias options in a single device.
This paper concerns recent research into the autonomous formation of micro-structures in low carbonyl iron powder (CIP) concentration magneto active polymers (MAP). Higher concentrations of CIP show an isotropic distribution of magnetic filler throughout the entire sample, while autonomous structure formation is possible at mass concentrations lower than 3%. The formation of micro-toroids commences as CIP concentration approaches 1% wt. Further development of coherent rings with a defined order follow as CIP concentrations increase toward 2% wt, whilst exceeding 3% wt leads to the same isotropic distribution found in higher concentration MAP. Structured samples containing between 1% wt and 3% wt CIP were investigated using X-Ray tomography where solitary structures could clearly be observed. The ring structures represent microinductivities whose geometries can be manipulated during fabrication. In addition, these structures are magnetic field sensitive. This is not only relevant to applications in the GHz and THz areas but recent research has revealed implications for optical, thermal, acoustic and even chemical MAP sensors. (C) 2019 Author(s).
This work describes the development of a new miniature extruder, essential to cavity-free 3D printing of silicone-based smart materials. This makes the 3D printing of magnetoactive and electroactive polymer soft robotic components and devices directly from CAD data possible. The special feature of such an extruder is that it is designed for use with addition-crosslinking RTV-2 silicones, including solid particulate additives. The extruder merges the respective components automatically during extrusion which obviates the need for premixing and vacuum evacuation. Problems associated with inhomogeneities and unwanted cavity production are consequently eliminated. Rheological details necessary to the design, together with some preliminary performance results, are presented.
Bio-Inspired Shape-Adaptive Soft Robotic Grippers Augmented with Electroadhesion Functionality
(2019)
Soft robotic grippers (SRGs) have been extensively employed in robotic grasping and manipulation applications due to the fact that they are beneficial for pick-and-place of difficult-to-handle and delicate objects with various geometries and stiffness in a comfortable and safer way. This article presents a bio-inspired and shape-adaptive SRG augmented with electroadhesion (EA) functionality, FinEA, by a cost-effective combination of a Fin Ray structured two-fingered SRG with two soft-stretchable EA pads. The EA pads were manufactured by screen printing a layer of electrically conductive and elastomeric carbon black powder mixed with polydimethylsiloxane onto a dielectric substrate. The compliant Fin Ray fingers, composed of soft longitudinal beams and rigid cross beams, were structurally optimized by the finite element method using ABAQUS/CAE based on three key parameters: the open angle of the longitudinal beams, the spacing between the cross beams, and the incline angle of the cross beams. The soft beams were produced by a traditional soft lithography method, whereas the rigid cross beams were three-dimensionally printed. The resultant FinEA grippers were capable of lifting not only flat/thin materials without distorting them due to the employment of EA, but also concave and convex objects due to the passively shape-adaptive Fin Ray structure and the EA functionality. In addition, the proposed FinEA grippers were able to grasp delicate materials and objects whose diameters are larger than the overall gripper length. Furthermore, 65% more weight in shear were picked up by the FinEA gripper when 4 kV was applied compared with 0 V. The FinEA concept provides useful and alternative solution for controllable adhesion-based SRGs and may facilitate the inspiration and development of future SRGs with added functionality and enhanced versatility.
Thermomechanical shape memory materials have certain disadvantages when it comes to 3D volumetric reproduction intended for rapid prototyping or robotic prehension. The need to constantly supply energy to counteract elastic retraction forces in order to maintain the required geometry, together with the inability to achieve conformal stability at elevated temperatures, limits the application of thermal shape memory polymers. Form removal also presents problems as most viscoelastic materials do not ensure demolding stability. This work demonstrates how magnetoactive boron−organo−silicon oxide polymers under the influence of an applied magnetic field can be used to achieve energy free sustainable volumetric shape memory effects over extended periods. The rheopectic properties of boron−organo−silicon oxide materials sustain form removal without mold distortion.