Lebenswissenschaften und Ethik
Refine
Year of publication
- 2024 (34)
- 2023 (150)
- 2022 (181)
- 2021 (162)
- 2020 (142)
- 2019 (173)
- 2018 (145)
- 2017 (147)
- 2016 (113)
- 2015 (104)
- 2014 (69)
- 2013 (74)
- 2012 (60)
- 2011 (87)
- 2010 (74)
- 2009 (53)
- 2008 (52)
- 2007 (41)
- 2006 (28)
- 2005 (43)
- 2004 (28)
- 2003 (40)
- 2002 (32)
- 2001 (20)
- 2000 (22)
- 1999 (8)
- 1998 (9)
- 1997 (7)
- 1996 (10)
- 1995 (4)
- 1994 (2)
- 1993 (4)
- 1992 (1)
- 1991 (1)
- 1990 (2)
- 1989 (1)
- 1982 (1)
Document Type
- Article (812)
- conference proceeding (article) (386)
- Part of a Book (348)
- conference proceeding (presentation, abstract) (159)
- Review (98)
- Book (82)
- conference talk (71)
- Report (48)
- Working Paper (43)
- Preprint (18)
Language
Is part of the Bibliography
- no (2134) (remove)
Keywords
- Bildgebendes Verfahren (22)
- Deep Learning (20)
- Deutschland (18)
- Politische Bildung (18)
- Künstliche Intelligenz (17)
- Aphasie (16)
- Digitalisierung (15)
- Diagnose (14)
- Gebärmutterhalskrebs (14)
- Rehabilitation (14)
Institute
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (1268)
- Institut für Sozialforschung und Technikfolgenabschätzung (IST) (520)
- Labor Empirische Sozialforschung (433)
- Fakultät Informatik und Mathematik (377)
- Fakultät Maschinenbau (275)
- Labor für Technikfolgenabschätzung und Angewandte Ethik (LaTe) (267)
- Regensburg Center of Biomedical Engineering - RCBE (257)
- Regensburg Center of Health Sciences and Technology - RCHST (234)
- Labor Biomechanik (LBM) (157)
- Regensburg Medical Image Computing (ReMIC) (149)
Begutachtungsstatus
- peer-reviewed (388)
- begutachtet (54)
Der Umstand, dass bis heute nicht bekannt ist, wie viele Menschen in Deutschland zuhause versterben, wird als Ausgangspunkt der Argumentation zugunsten der Etablierung eines Sterbeortregisters gewählt. Hierfür wird die grundsätzliche Bedeutung – bei durchaus heterogenen Zielsetzungen und funktionalem Zweck – medizinischer Register erkennbar gemacht. Deutlich wird, dass von einem Sterbeortregister kurzfristig insbesondere für die Versorgungsplanung und die Gesundheitspolitik, mittelfristig aber auch für die Qualitäts-entwicklung der Versorgung sowie mittel- bis langfristig Erkenntnisse für die Versorgungsforschung und für epidemiologische Studien, ein deutlicher Nutzen zu erwarten ist. Dies betrifft alle Orte (Milieus, Settings) der Versorgung. Um solch ein Sterbeortregister inhaltlich und auch funktional wirkungsvoll auszugestalten, sollte eine interdisziplinäre Arbeitsgruppe mit transsektoraler Erfahrung über die Palliativversorgung hinausreichend zusammengeführt werden. Indes wäre allein schon die genaue – und jährlich berichtete – Ermittlung des Sterbeortes ein deutlicher und praktisch einfach zu erreichender Fortschritt.
Der Beitrag soll auf die Verlegung sterbender Menschen in Krankenhäusern und Pflegeeinrichtungen aufmerksam und dabei entstehende ethische Problemlagen bzw. Herausforderungen erkennbar machen. Grundlage hierfür sind Studien zur Versorgungspraxis; jeder vierte sterbende Heimbewohner und jeder fünfte sterbende Krankenhauspatient wird in der letzten Lebensphase verlegt. Ursachen hierfür sind vielfältig und betreffen medizinisch-pflegerische, soziale, organisatorische sowie ökonomische Faktoren. Häufig werden Verlegungen notfallähnlich aus überforderten Versorgungsbereichen hin zu Stationen mit erhöhter personeller Ausstattung sowie professioneller und sozialer Versorgungskompetenz vollzogen.
Verbesserte Menschen
(2015)
Was zunächst nur als verheißungsvolle Utopie am Zukunftshorizont der Gentechnik aufschien, ist längst dem bioethischen Diskurs entwachsen und konfrontiert uns mit grundlegenden Fragen unseres menschlichen Selbstverständnisses: die Verbesserung und zunehmende Technisierung des Menschen. In diesem Band wird das Thema Enhancement aus sozialphilosophischer und technikphilosophischer Perspektive behandelt. Thomas Zoglauer zeichnet die wesentlichen ethischen Argumentationslinien dieser Debatte nach und setzt sich kritisch mit dem Enhancement unter den Aspekten der Freiheit, sozialen Gerechtigkeit, Chancengleichheit und menschlichen Wohlergehens auseinander. Karsten Weber zeigt wie das Konzept des Cyborgs von der Science-Fiction-Literatur geprägt wurde und als utopisches Leitbild die Medizin- und Neurotechnik beeinflusst hat. Als Folge dieser Entwicklung beginnen sich die Unterschiede zwischen Mensch und Maschine und die damit verbundenen anthropologischen Dichotomien aufzulösen, was auch Konsequenzen für unser Menschenbild und die normative Bewertung des Enhancements hat.
Zur diagnostischen Unterstützung bei der Befundung laryngealer Erkrankungen soll eine Farb- und Formanalyse der Stimmlippen durchgeführt werden. In diesem Beitrag wird ein Verfahren zur Trennung der spiegelnden und diffusen Reflexionsanteile in Farbbildern des Larynx vorgestellt. Die Farbe der diffusen Komponente entspricht dabei der beleuchtungsunabhängigen Objektfarbe, während deren Wichtungsfaktoren als Eingabe für Shape-from-Shading-Verfahren zur Oberflächenrekonstruktion dienen.
Video Documentation of endoscopic findings simplifies diagnostic counseling of the patient and aids pre-operative discussion among the medical team. Judgment of such images is still subjective and can not give a quantitative evaluation of the disease process regarding diagnosis or response to treatment. Modern treatment of early laryngeal cancer with laserablation requires intensive follow up and frequent direct laryngoscopy under general anesthesia with blind biopsies to detect any tumor residual or recurrence. Inflammatory conditions of the larynx are frequently confused with other causes of dysphonia. Mapping anddigital analysis of the documented image will suggest the tumor site and avoids undue blind biopsies under anesthesia. However, varying illumination results in different colors reflected from the same object. To achieve quantitative analysis, color constancy has to be assured. Inthis paper, the environment is presented which allow the objective judgment of larngoscopies.
Quantitative Farbmessungen sollen die Diagnostik laryngealer Erkrankungen unterstützen. Dabei wird der Farbeindruck nicht nur durch die Reflexionseigenschaften des Gewebes sondern auch durch die Farbe der verwendeten Lichtquelle beeinflußt. Der hier vorgestellte Farbkonstanz-Algorithmus basiert auf dem dichromatischen Reflexionsmodell und liefert eine pixelweise Trennung des Farbbildes in seine beiden Faxbanteile. Die Körperfarbe entspricht dabei der gewebespezifischen Reflexion, die Oberfächenfarbe der Strahlung der Lichtquelle.
Nutzung eines Farbkonstanz-Algorithmus zur Entfernung von Glanzlichtern in laryngoskopischen Bildern
(1998)
1 Einführung
Funktionelle und organische Störungen im Larynx beeinträchtigen die Ausdrucksfähigkeit des Menschen. Zur Diagnostik und Verlaufkontrolle werden die Stimmlippen im Larynx mit Hilfe der Video-Laryngoskopie aufgenommen. Zur optimalen Farbmessung wird dazu an das Lupenendoskop eine 3-Chip-CCD-Kamera angeschlossen, die eine unabhängige Aufnahme der drei Farbkanäle erlaubt. Die bisherige subjektive Befundung ist von der Erfahrung des Untersuchers abhängig und läßt nur eine grobe Klassifikation der Krankheitsbilder zu. Zur Objektivierung werden daher quantitative Parameter für Farbe, Textur und Schwingung entwickelt. Neben dem Einfluß der wechselnden Lichtquellenfarbe auf den Farbeindruck ist die Sekretauflage auf den Stimmlippen ein Problem bei der Farb-und Texturanalyse. Sie kann zu ausgedehnten Glanzlichtern führen und so weite Bereiche der Stimmlippen für die Farb-und Texturanalyse unbrauchbar machen. Dieser Beitrag stellt einen Farbkonstanz-Algorithmus vor, der unabhängig von der Lichtquelle quantitative Farbwerte des Gewebes liefert und die Glanzlichtdetektion und -elimination ermöglicht.
2 Methodik
Ziel des Farbkonstanz-Algorithmus ist die Trennung von Lichtquellen-und Gewebefarbe. Unter Verwendung des dichromatischen Reflexionsmodells [1] kann die Oberflächenreflexion mit der Farbe der Lichtquelle und die Körperreflexion mit der Gewebefarbe identifiziert werden. Der Farbeindruck entsteht aus der Linearkombination beider Farbkomponenten. Ihre Gewichtung ist von der Aufnahmegeometrie abhängig, insbesondere vom Winkel zwischen Oberflächennormalen und dem Positionsvektor der Lichtquelle. In einem zweistufigen Verfahren wird zunächst die Lichtquellenfarbe geschätzt, dann die Gewebefarbe ermittelt. Hieraus können beide Farbanteile durch die Berechnung der Gewichtsfaktoren pixelweise getrennt werden.
Laryngoscopic images of the vocal tract are used for diagnostic purposes. Quantitative mea-surements like changes of the glottis size or the surface of the vocal cords during an image sequence can be helpful to describe the healing process or to compare the findings of diffe-rent patients. Typically the endoscopic images are circulary symmetric distorted (barrel di-stortion). Therefore measurements of geometric dimensions depend on the object´s position in the image. In this paper an algorithm is presented which allows the computation of the translational invariant "real" object size by correcting the image distortion without using additional calibration of the optical environment.
Background
Breast reconstruction is an important coping tool for patients undergoing a mastectomy. There are numerous surgical techniques in breast reconstruction surgery (BRS). Regardless of the technique used, creating a symmetric outcome is crucial for patients and plastic surgeons. Three-dimensional surface imaging enables surgeons and patients to assess the outcome’s symmetry in BRS. To discriminate between autologous and alloplastic techniques, we analyzed both techniques using objective optical computerized symmetry analysis. Software was developed that enables clinicians to assess optical breast symmetry using three-dimensional surface imaging.
Methods
Twenty-seven patients who had undergone autologous (n = 12) or alloplastic (n = 15) BRS received three-dimensional surface imaging. Anthropomorphic data were collected digitally using semiautomatic measurements and automatic measurements. Automatic measurements were taken using the newly developed software. To quantify symmetry, a Symmetry Index is proposed.
Results
Statistical analysis revealed that there is no dif- ference in the outcome symmetry between the two groups (t test for independent samples; p = 0.48, two-tailed).
Conclusion
This study’s findings provide a foundation for qualitative symmetry assessment in BRS using automatized digital anthropometry. In the present trial, no difference in the outcomes’ optical symmetry was detected between autologous and alloplastic approaches.
Objective:
Complex hue/saturation images as a new approach for color texture classification using Gabor filters are introduced and compared with common techniques.
Method:
The interpretation of hue and saturationas polar coordinates allows direct use of the HSV-colorspace for Fourier transform. This technique is applied for Gabor feature extraction of color textures. In contrast to other color features based on the RGB-colorspace [1] the combination of color bands is done previous to the filtering.
Results:
The performance of the new HS-featuresis compared with that of RGB based as well as grayscale Gabor features by evaluating the classifi-cation of 30 natural textures. The new HS-featuresshow same results like the best RGB features but allow a more compact representation. On the averagethe color features improve the results of grayscale features.
Conclusion:
The consideration of the color information enhances the classification of color texture. The choice of colorspace cannot be adjudged finally, but the introduced features suggest the use of the HSV-colorspace with less features than RGB.
Objectives
Tumor size is a well recognized prognostic factor in early stage cervical carcinoma (CX). However, limited knowledge exists about the value of tumor size in surgically treated CX with extrauterine extension.
Methods
245 cases of local advanced CX (FIGO stage IIA and IIB) who received upfront surgery were evaluated regarding tumor size, regarding the prediction of pelvic lymph node involvement and recurrence free and overall survival during a median follow-up time of 54 months (95% CI 45.4–62.6 months). Tumors larger than 4 cm were defined as bulky stage disease.
Results
Bulky disease was seen in 46.1% (113/245). 60.2% of these patients showed pelvic lymph node involvement, compared to 42.4% (56/132) in non-bulky tumors (p = 0.006; odds ratio: 2.2 [95% CI: 1.3–3.6]). Patients with bulky tumors showed an increase of recurrent disease (40.2% vs. 28.0%; p = 0.045). The relative risk for recurrent disease was 1.97 (95% CI: 1.3–3.0). The 5-year overall survival rate was significantly lower (67.7% [95% CI: 58.2–74.8] vs. 49.5% [95% CI: 36.8–59.1]; p = 0.0015). In multivariate analysis, tumor stage, pelvic lymph node involvement and maximal tumor size were independent prognostic factors.
Conclusions
The results suggest that tumor size, defining bulky disease as tumors larger than 4 cm, is of prognostic impact also in FIGO stage II cervical carcinomas. A revised FIGO/TNM classification system similar to the subgrouping of stage IB CX is recommended for stage II using a cut-off value of 4 cm as discriminator: stage IIA1 and stage IIB1 for tumors with ≤ 4 cm and IIA2 and IIB2 for tumors > 4 cm (i.e. bulky disease).
Objectives: Different patterns of invasion (representing different grades of tumor cell dissociation) are associated with prognostic outcome in cancer. We evaluated the prognostic value of different patterns of invasion (PI) in cervical carcinomas (CX).
Methods: Six hundred eleven surgically treated CX (FIGO IB to IIB) were re-evaluated histologically regarding the PI, using a three-level scoring system. Closed PI was defined as cohesive growth with well-delineated (pushing) borders. In finger-like PI the tumor grows in solid cords/trabecles. Highly dissociative growth in small groups or single cells was defined as spray-like PI. Types of PI were correlated to tumor stage, histo-morphologic factors and prognostic outcome.
Results: Sixty percent of the tumors showed a spray-like PI, 30% a finger-like PI and only 7.4% were of the closed type. Spray-like PI showed a significant correlation with advanced stage disease, lymphovascular space involvement, poorly differentiated tumors and pelvic lymph node metastases. Spray-like PI was accompanied by a reduced 5-year overall survival when compared to the finger-like and closed PI (68.7% vs. 80.9% vs. 88.5%; P=0.0004). The prognostic impact of the PI disappeared in node-positive patients (P=0.06) but persisted in patients without pelvic lymph node disease (P=0.03). In multivariate analysis, using COX regression model, the PI represented as independent prognostic factor.
Conclusions: Spray-like PI (i.e., highest degree of tumor cell dissociation) is associated with advanced tumor stages, increased rate of recurrency and a reduced overall survival. In separate analysis of patients with and without lymph node metastases, the impact of PI persisted only in node-negative cases as a prognostic factor.
Several kinds of cellular adhesion molecules, like different splicing variants of CD 44, have gained important as prognostic or markers for metastatic disease. Fresh frozen samples from 64 cervical carcinoma (CX) were stored in liquid nitrogen and examined using ELISA-technique, testing the prognostic impact. Normal cervical tissue served as control. CD 44-v6 concentration, was significant elevated in tumor tissue, when compared to the controls (P=0.04). There was no correlation to tumor stage (P=0.61), lymphovascular space involvement (P=0.075) or pelvic lymph node involvement (P=0.81). The CD 44-v6 concentration was not informative regarding recurrence-free and overall survival. Contrary to immunohistochemistry, the quantification of CD 44-v6 using ELISA-technique does not provide any further information.
Objective: To determine the utility of DNA content and DNA-related variables of proliferative activity regarding prognosis in cervical cancer.
Study design: DNA image (ICM) andflow cytometry (FCM) were performed to determine the DNA index (DI), 5c-exceeding rate (5c-ER), S-phase fraction (SPF) and proliferation index (PI) in 163 patients with surgically staged pT1b1-pT2b squamous cell cancer of the uterine cervix and treated with primary radical hysterectomy. ICM was performed on imprint cytology, obtained from fresh tumor tissue, which was also used for FCM. Results were analyzed using the chi2 test and Cox regression analysis for risk of pelvic lymph node involvement, tumor recurrence and recurrence-free survival (RFS).
Results: ICM was performed on all 163 and FCM on 133 samples. One-third of the tumors showed DNA aneuploidy. Analysis demonstrated prognostic significance of a DI > or = 1.70, with a (70:30) 2.3-fold risk of recurrence (P=.024) and reduced RFS of 10 months (P=.003) in cases of DI > or = 1.70. A high 5c-ER > 11% was associated with pelvic lymph node involvement and decreased RFS (P < or = .04). Significantly more relapses were found in tumors with SPF > 12% (70.8% vs. 29.2%, P=.007). RFS was markedly reduced in tumors with high SPF (52.3 vs. 61.1 months, P=.011). Low proliferative tumors (PI<25%) were associated with lower stage (P=.036) and increased RFS (61.2 vs. 47.1 months, P=.028). In multivariate analysis of clinicopathologic variables (pT category, nodal status, lymphovascular space involvement) and DNA related variables, pelvic lymph node involvement was the only significant predictor of RFS. In patients with nodal involvement, tumors with DI >1.70 were associated with lessfavorable outcomes.
Conclusion: DNA-related variables of cell cycle analysis were valuablefor predicting prognosis in cervical cancer patients. Tumors with DI>1.70, 5c-ER >11% and high proliferative activity (SPF>12%, PI>25%) represent a subgroup with a poor prognosis.
Recent developments in lasers have provided us the possibility of laser ocular surgery. The xenon, argon, neodymium:YAG and dye lasers have been successfully used in out-patient clinics. The excimer laser has been attracting researchers' interest in the new application of laser to cornea and lens. The erbium:YAG laser emits a 2.94-microns beam that can ablate the transparent ocular tissues such as lenses and corneas. The author has applied this laser to the cornea, lens, vitreous and other ocular tissues. The erbium:YAG laser beam was directed through a 1.5-meter-long, 200-microns-diameter fiberoptic guide. The radiant energy measured about 50 mJ at the end of the probe. The laser was emitted as a 400-microsecond pulse. Freshly enucleated rabbit eyes were used in this study. Laser burns were applied to the tissue surface at various energy settings. At minimal power, the tissues were coagulated by the erbium:YAG laser application. At a power of more than 636-954 mJ/mm2, tissue began to evaporate; the tissue loss was observed under a surgical light microscope. Corneal photoablation, lens ablation, iridotomy, trabeculotomy, cutting of the vitreous and retinal ablation were easily performed. Like the excimer laser, the erbium:YAG laser is a potential tool for ocular surgery.
Objective
The expression of uPA and PAI‐1 as parameters of tumour‐associated proteolysis has been implicated in the process of tumour cell invasion and the metastatic process. However, there is limited information on the impact of these parameters in cervical carcinoma.
Methods
Quantitative levels for uPA (n = 114) and PAI‐1 (n = 103) were researched in operatively treated, surgically staged squamous cell cancer of the uterine cervix, using an ELISA‐technique. Results were assessed regarding their impact in predicting pelvic lymph nodes metastases, tumour recurrence rate and recurrence free survival (RFS) using uni‐ and multivariate analysis.
Results
Median levels of both parameters were significantly higher in tumour tissue than in normal cervical tissue (p < 0.001). Detection of uPA gave no useful prognostic information. PAI‐1 concentration showed a positive correlation with advanced tumour stage (p = 0.008), but no significant correlation with nodal status (pN0: 2.6 vs. pN1: 4.0 ng/mg protein; p = 0.092). Using a cut‐off level of 2.4 ng/mg protein, patients with elevated PAI‐1 levels demonstrated reduced RFS (45.9 versus 52.9 months; p = 0.1). Multivariate analysis, including nodal status, tumour stage, lymphovascular space involvement and grading failed to demonstrate any prognostic impact of uPA and PAI‐1.
Conclusions
The results indicate, that PAI‐1 expression is of some prognostic impact in cervical cancer, indicating an association of elevated PAI levels with local tumour progression and reduced recurrence‐free survival.
Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation
(2020)
Background:
Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity.
Methods:
Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction.
Results:
Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2% (gluteus medius).
Conclusions:
In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved.
Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach.
Fragestellung: Molekulare Analysen haben deutlich gemacht, dass maligne Tumoren durch Veränderungen des Genoms hervorgerufen werden. Im Gegensatz zu den erblich bedingten Tumorerkrankungen sind die Kenntnisse zur Bedeutung familiärer Faktoren bei den sog. sporadischen Tumoren, insbesondere beim Zervixkarzinom (CX) begrenzt. Material und Methode: Patientinnen des CX-Registers der Universitäts-Frauenklinik wurden retrospektiv bezüglich der Familienanamnese (FA) analysiert. Als positive FA wurde eine maligne Tumorerkrankung bei einem oder mehreren Verwandten ersten Grades definiert. Es wurde unterschieden, ob es sich um Zervixkarzinome, andere gynäkologische Malignome (außer Mammakarzinom) oder eine extragenitale Lokalisation handelte. Diese Daten wurden zum Erkrankungsalter und zum Nachweis pelviner Lymphknotenmetastasen in Beziehung gesetzt. Ergebnisse: 159/737 Frauen (21,6 %) wiesen eine positive FA auf. In 10,7 % der Fälle war mehr als ein Verwandter ersten Grades erkrankt; bei 6,9 % Angehörige ersten und zweiten Grades. Weibliche Verwandte ersten Grades von 42 Frauen wiesen Malignome des weiblichen Genitaltraktes (außer CX) auf. In 6,9 % waren die Mutter und/oder die Schwester an einem Zervixkarzinom erkrankt. Das Durchschnittsalter der Patientinnen mit positiver Familienanamnese (FA) unterschied sich nicht von dem derjenigen mit leerer FA, wohl aber bei getrennter Betrachtung nach der Tumorlokalisation. Bezüglich des Tumorstadiums (pTNM) und der Zahl der Patientinnen mit histologisch nachgewiesenen pelvinen Lymphknotenmetastasen bestand kein Unterschied. Schlussfolgerungen: Die bisherigen Ergebnisse deuten auch beim Zervixkarzinom auf eine familiäre Belastung hin. Dabei existieren offenbar Familien, in denen mit HPV-assoziierte Präkanzerosen bzw. Tumoren vermehrt auftreten. Besonders gefährdet sind Patientinnen, deren weibliche Anverwandte ersten Grades bereits an einer zervikalen Präkanzerose (besonders CIN III) oder einem invasiven CX erkrankt sind. Diese Frauen sollten einem engmaschigen Screening unterzogen werden.
Local gray level dependencies of natural images can be modelled by means of co-occurrence matrices containing joint probabilities of gray-level pairs. Texture, however, is a resolution-dependent phenomenon and hence, classification depends on the chosen scale. Since there is no optimal scale for all textures we employ a multiscale approach that acquires textural features at several scales. Thus linear and nonlinear scale-spaces are analyzed by multiscale co-occurrence matrices that describe the statistical behavior of a texture in scale-space. Classification is then performed on the basis of texture features taken from the individual scale with the highest discriminatory power. By considering cross-scale occurrences of gray level pairs, the impact of filters on the feature is described and used for classification of natural textures. This novel method was found to improve classification rates of the common co-occurrence matrix approach on standard textures significantly.
Zur Lösung komplexer Segmentierungsprobleme wird eine hierarchische und farbbasierte Wasserscheidentransformation vorgestellt. Geringe Modifikationen bezüglich Startpunktwahl und Flutungsprozess resultieren in signifikanten Verbesserungen der Segmentierung. Das Verfahren wurde zur Lippendetektion in Farbbildsequenzen eingesetzt, die zur quantitativen Beschreibung von Sprechbewegungsabläufen automatisch ausgewertet werden. Die Experimente mit 245 Bildern aus 6 Sequenzen zeigten eine Fehlerrate von 13%.
The gold standard for the analysis of human kinematics and kinetics is a camera-based motion capture system in combination with force measurement platforms. Alternatively, inertial measurement units can be utilized to obtain human kinematics, while ground reaction forces are computed from full body dynamics. This setup represents a system independent from the spatial confinement of a gait laboratory. The aim of this study is the comparison of the two methods by the investigation of lower limb kinematics and the resulting joint reaction forces within the ankle-, knee- and hip joints. For this purpose, human motion during gait was captured simultaneously by both measurement techniques. 13 trials from 8 different test subjects were evaluated in total. IMU data was processed with a quaternion based Kalman Filter. The data sets were implemented into a musculoskeletal simulation program in order to drive a virtual human body model. Each sensor was aligned to the gravitational and magnetic field vectors of the earth. The angles of flexions, extensions and rotations were analyzed to determine kinematic differences. Joint reaction forces defined kinetic dissimilarities. The overall kinematic differences of both models yielded root mean square errors of 7.62°, 6.02°, 4.95°, 2.79°, 2.38° and 3.56° for ankle flexion, subtalar eversion, knee flexion, hip external rotation, hip abduction and hip flexion, respectively. The proximo-distal differences in force peaks between the models yielded overall for the ankle, 57.33 %Bodyweight(BW) ± 46.86 %BW (16.66 %(Maximum peak to peak) ± 13.62 %) for the knee 37.09 %BW ± 29.33 %BW (17.65 % ± 15.44 %) and 32.03 %BW ± 24.33 %BW (15.6 % ± 12.54 %) for the hip. The overall outcome of this work investigated an approach independent of the common setup of the gait laboratory, thus enabling a cheaper and more flexible technology as an alternative. However, kinematic and thus kinetic differences remain rather large. Future work aims to improve the contact criterion for the calculation of the ground reaction forces and the implementation of a full-body calibration algorithm for the IMU system in order to counteract magnetic field disturbances.
Common Schanz screw systems can be used to stabilize pelvic ring fractures. In order to accommodate for different patient’s requirements, implants can be placed in cranio-caudal direction into the os ilium (T1), or into the supraacetabular bone canal, and thus, in dorso-ventral direction (T2). Whereas both techniques are currently used, no data of the biomechanical behavior is available up to this date. The aim of this study is to analyze, whether T2 shows biomechanical advantages with respect to tissue and implant stresses due to the enlarged bone-implant interface. Forces acting on the pelvis were analyzed using motion capture data of a gait cycle obtained by the utilization of a musculoskeletal simulation program. A three dimensional finite element (FE) model of the pelvis with grayscale-based material properties was generated. The muscle and joint reaction forces at toe-off were applied to the FE model and instable pelvis fractures were implemented. The osteosynthesis systems were positioned within the model in order to enable the comparison between the two different surgical techniques. Stresses and displacements were analyzed for bone tissue, fracture zone and implant.
T2 lead to approx. 30% larger displacements in the fracture zone. Von-Mises stresses were larger for T2 in the implant (80 MPa vs. 227 MPa), whereas T1 leads to larger stresses in the bone tissue (200 MPa vs. 140 MPa).
Both implantation techniques showed a good biomechanical behavior. Differences could be found with respect to tissue strains and deformations in the fracture zone. If bone quality or fracture healing are of concern, T2 or T1 should be used, respectively. However, both techniques seem to be applicable for cases with no special requirements. Further analyses aim to investigate the behavior under cyclic loading.
Thoracolumbar spine model with articulated ribcage for the prediction of dynamic spinal loading
(2016)
Musculoskeletal modeling offers an invaluable insight into the spine biomechanics. A better understanding of thoracic spine kinetics is essential for understanding disease processes and developing new prevention and treatment methods. Current models of the thoracic region are not designed for segmental load estimation, or do not include the complex construct of the ribcage, despite its potentially important role in load transmission. In this paper, we describe a numerical musculoskeletal model of the thoracolumbar spine with articulated ribcage, modeled as a system of individual vertebral segments, elastic elements and thoracic muscles, based on a previously established lumbar spine model and data from the literature. The inverse dynamics simulations of the model allow the prediction of spinal loading as well as costal joints kinetics and kinematics. The intradiscal pressure predicted by the model correlated well (R2=0.89) with reported intradiscal pressure measurements, providing a first validation of the model. The inclusion of the ribcage did not affect segmental force predictions when the thoracic spine did not perform motion. During thoracic motion tasks, the ribcage had an important influence on the predicted compressive forces and muscle activation patterns. The compressive forces were reduced by up to 32%, or distributed more evenly between thoracic vertebrae, when compared to the predictions of the model without ribcage, for mild thoracic flexion and hyperextension tasks, respectively. The presented musculoskeletal model provides a tool for investigating thoracic spine loading and load sharing between vertebral column and ribcage during dynamic activities. Further validation for specific applications is still necessary.
Effect of the fractured calcaneus's peripheral fragment displacement on the triceps surae function
(2015)
We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient’s gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome.
Different target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.In a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek's "safe zone" were evaluated regarding their impact on gait patterns and clinical outcome.Combined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek's "safe zone" did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.Standard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA.
Influence of minimally invasive total hip replacement on hip reaction forces and their orientations
(2014)
Minimally invasive surgery (MIS) is becoming increasingly popular. Supporters claim that the main advantages of MIS total hip replacement (THR) are less pain and a faster rehabilitation and recovery. Critics claim that safety and efficacy of MIS are yet to be determined. We focused on a biomechanical comparison between surgical standard and MIS approaches for THR during the early recovery of patients. A validated, parameterized musculoskeletal model was set to perform a squat of a 50th percentile healthy European male. A bilateral motion was chosen to investigate effects on the contralateral side. Surgical approaches were simulated by excluding the incised muscles from the computations. Resulting hip reaction forces and their symmetry and orientation were analyzed. MIS THR seemed less influential on the symmetry index of hip reaction forces between the operated and nonoperated leg when compared to the standard lateral approach. Hip reaction forces at peak loads of the standard transgluteal approach were 24% higher on the contralateral side when compared to MIS approaches. Our results suggest that MIS THR contributes to a greater symmetry of hip reaction forces in absolute value as well as force-orientation following THR.
In the last few years, increasingly kicks to the head were observed as a criminal offense. This study examined the
influence of age, shoe type and kicking direction on the severity of head trauma.
Male test persons were divided into two groups “Old” and “Young”. Both groups were equipped with light
sneakers and combat boots. A standard laboratory crash dummy was used to simulate the victim’s body. First, the
dummy’s head, free floating above the ground, was kicked vertically. Second, the dummy’s head was kicked
horizontally. Established injury criteria were used to quantify the injury risk.
No influence concerning the type of foot wear and no difference between the groups “Old” and “Young” could be
found. For all analyses, kicking vertically generally lead to a higher risk for the subject compared to kicking
horizontally.
In this study, only the integral effect of the kicks could be analyzed. A detailed injury pattern cannot directly be
derived from the data. Nevertheless, the presented data show the massive potential of injuries associated with head
kicks.
Meniscal tears in the avascular zone have a poor self-healing potential, however partial meniscectomy predisposes the knee for early osteoarthritis. Tissue engineering with mesenchymal stem cells and a hyaluronan collagen based scaffold is a promising approach to repair meniscal tears in the avascular zone. 4 mm longitudinal meniscal tears in the avascular zone of lateral menisci of New Zealand White Rabbits were performed. The defect was left empty, sutured with a 5-0 suture or filled with a hyaluronan/collagen composite matrix without cells, with platelet rich plasma or with autologous mesenchymal stem cells. Matrices with stem cells were in part precultured in chondrogenic medium for 14 days prior to the implantation. Menisci were harvested at 6 and 12 weeks. The developed repair tissue was analyzed macroscopically, histologically and biomechanically. Untreated defects, defects treated with suture alone, with cell-free or with platelet rich plasma seeded implants showed a muted fibrous healing response. The implantation of stem cell-matrix constructs initiated fibrocartilage-like repair tissue, with better integration and biomechanical properties in the precultured stem cell-matrix group. A hyaluronan-collagen based composite scaffold seeded with mesenchymal stem cells is more effective in the repair avascular meniscal tear with stable meniscus-like tissue and to restore the native meniscus.
Measuring functional outcome after total hip replacement with subject-specific hip joint loading
(2012)
Total hip replacement is an often-performed orthopedic surgical procedure; the amount of procedures undertaken will increase since our life expectancy is growing. In order to optimize function, hip biomechanics should be restored to as near normal as possible. The goal of this pilot study was to determine whether or not it is feasible to compute the vectorial hip reaction force pathways on the head of the prosthesis and the force angles relative to the cup of the prosthesis that occur during gait in total hip replacement patients, serving as an objective measurement of the functional outcome following hip replacement. A three-dimensional gait analysis, measuring ground reaction forces and kinematics, was performed. The data retrieved from the gait analysis was used as the input for the musculoskeletal model to compute vectorial joint reaction forces for data processing. To evaluate the position and orientation of the joint reaction forces, the force path, as well as the force angles for the operated and non-operated joint, has been calculated during the stance phase of the specific leg. The force path for subject 2 on the non-operated side is only located in the posterior-lateral quarter, as is the force path for subject 1. In contrast to this subject, the force path for subject 2 at the operated hip joint can be found only within the anterior quarter of the head of the implant, where it is nearly equally distributed in the medio-lateral half of the prosthesis head. The force-inclination angles on the cup of subject 1, with respect to the plane of the socket face, indicates that the force vector is mainly positioned in the same quadrant when compared with subject 2 (in a cup-fixed coordinate system). The force-anteversion angle behaves similarly to the force-inclination angle, even when the effects are not as pronounced. The proposed methods in this article are aiming to define two functional outcomes of total hip replacement that are related to wear and rim loading. It is accepted that wear is not only a function of time, but a function of use. Owing to the methods listed in this article, we are able to determine a) the applied force and b) the sliding distance (force pathway) in a subject-specific manner. The computed hip-reaction force angles and the distance to the rim cup are a measurement for cup or rim loading, and occurs in the so-called safe-zones. This method may well give us insight into the biomechanical situation during gait, after receiving total hip replacement, that we need to fully understand the mechanisms acting on a hip joint and to prove a possible increase of functional outcome after receiving total hip replacement.
Whilst considerable progress has been made in enhancing the quality of indirect laryngoscopy and image processing, the evaluation of clinical findings is still based on the clinician's judgement. The aim of this paper was to examine the feasibility of an objective computer-based method for evaluating laryngeal disease. Digitally recorded images obtained by 90 degree- and 70 degree-angled indirect rod laryngoscopy using standardized white balance values were made of 16 patients and 19 healthy subjects. The digital images were evaluated manually by the clinician based on a standardized questionnaire, and suspect lesions were marked and classified on the image. Following colour separation, normal vocal cord areas as well as suspect lesions were analyzed automatically using co-occurrence matrices, which compare colour differences between neighbouring pixels over a predefined distance. Whilst colour histograms did not provide sufficient information for distinguishing between healthy and diseased tissues, consideration of the blue content of neighbouring pixels enabled a correct classification in 81.4% of cases. If all colour channels (red, green and blue) were regarded simultaneously, the best classification correctness obtained was 77.1%. Although only a very basic classification differentiating between healthy and diseased tissue was attempted, the results showed progress compared to grey-scale histograms, which have been evaluated before. The results document a first step towards an objective, machine-based classification of laryngeal images, which could provide the basis for further development of an expert system for use in indirect laryngoscopy.
Volumetric representations of autoradiographic and histological images gain ever more interest as a base to interpret data obtained with /spl mu/-imaging devices like microPET. Beyond supporting spatial orientation within rat brains especially autoradiographic images may serve as a base to quantitatively evaluate the complex uptake patterns of microPET studies with receptor ligands or tumor tracers. They may also serve for the development of rat brain atlases or data models, which can be explored during further image analysis or simulation studies. In all cases a consistent spatial representation of the rat brain, i.e. its anatomy and the corresponding quantitative uptake pattern, is required. This includes both, a restacking of the individual two-dimensional images and the exact registration of the respective volumes. We propose strategies how these volumes can be created in a consistent way and trying to limit the requirements on the circumstances during data acquisition, i.e. being independent from other sources like video imaging of the block face prior to cutting or high resolution micro-X-ray CT or micro MRI.
In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis.
The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions which are not aligned with the main physiological axis remains unclear. Furthermore site and species dependent relationships are not well described. In this study five different groups of trabecular bone, defined in terms of orientation, species and site were exposed to cyclic compression. In total, 108 fatigue tests were analysed. The lifetimes were found to decrease drastically when off-axis loads were applied. Additionally, species and site strongly affect fatigue lifetimes. Strains at failure were also found to be a function of orientation.
PURPOSE:
The purpose of this study was to find a suitable method of labelling cartilage samples for the measurement of distraction distances in biomechanical testing.
METHODS:
Samples of bovine cartilage were labelled using five different methods: hydroquinone and silver nitrate (AgNO3), potassium permanganate (KMnO4) with sodium thiosulphate (Na2S2O3), India ink, heat, and laser energy. After the labelling, we analysed the cartilage samples with regard to cytotoxity by histochemical staining with ethidiumbromide homodimer (EthD-1) and calcein AM. Furthermore, we tested cartilages labelled with India ink and heat in a T-peel test configuration to analyse possible changes in the mechanical behaviour between marked and unlabelled samples.
RESULTS:
Only the labelling methods with Indian ink or a heated needle showed acceptable results in the cytotoxity test with regard to labelling persistence, accuracy, and the influence on consistency and viability of the chondrocytes. In the biomechanical T-peel configuration, heat-labelled samples collapsed significantly earlier than unlabelled samples.
CONCLUSION:
Labelling bovine cartilage samples with Indian ink in biomechanical testing is a reliable, accurate, inexpensive, and easy-to-perform method. This labelling method influenced neither the biomechanical behaviour nor the viability of the tissue compared to untreated bovine cartilage.
A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis.
The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of normal gait. To evaluate the testing system, 12 femora pairs were tested under 25,000 cycles with two standard osteosyntheses (Proximal Femoral Nail Antirotation/Gamma3 Nail). For angular movement, the varus collapse to cut out (∝CO) (∝CO=4.8°±2.1° for blade and ∝CO=7.8°±3.8° for screw) was the dominant failure mode, and only slight rotational angle shifts (∝Rot) (∝Rot=1.7°±0.4° for blade and ∝Rot=2.4°±0.3° for screw) of the femoral head around the implant axis were observed. Angular displacements in varus direction and rotation were higher in specimens reinforced with screws. Hence, the cut out model and the migration directions showed a distinction between helical blade and hip screw. However, there were no significant differences between the different implants. The new setup is able to create clinical failures and allows to give evidence about the anchorage stability of different implant types under dynamic gait motion pattern.
Repeated loadings may cause fatigue fractures in bony structures. Even if these failure types are known, data for trabecular bone exposed to cyclic loading are still insufficient as the majority of fatigue analyses on bone concentrate on cortical structures. Despite its highly anisotropic and inhomogeneous structure, trabecular bone is treated with continuum approaches in fatigue analyses. The underlying deformation and damage mechanism within trabecular specimens are not yet sufficiently investigated. In the present study different types of trabecular bone were loaded in monotonic and cyclic compression. In addition to the measurement of integral specimen deformations, optical deformation analysis was employed in order to obtain strain distributions at different scale levels, from the specimens' surface to the trabeculae level. These measurements allowed for the possibility of linking the macroscopic and microscopic mechanical behaviour of cancellous bone. Deformations were found to be highly inhomogeneous across the specimen. Furthermore strains were found to already localise at very low load levels and after few load cycles. Microcracks in individual trabeculae were induced in the very early stage of cyclic testing. The results provide evidence of the capability of the method to supply essential data on the failure behaviour of individual trabeculae in future studies.
The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions not aligned with the main physiological axis remains unclear. Furthermore age effects on the fatigue behaviour are not well described. In the present study, different groups of human vertebral cancellous bone were exposed to cyclic compression. The inital modulus and therefore lifetimes were found to be highly dependent on age. The decrease in both with increasing age was much more pronounced in specimens which were not aligned with the main physiological axis. This implies that old bone is much more sensitive to (cyclic) failure loads in general but particularly to loads which are not coincident with the physiological main axis.
Objectives: The mechanical properties and seeding with endothelial cells were investigated in fresh and cryopreserved human umbilical vein.
Methods: Human umbilical veins (HUV) were frozen in Euro-Collins/1M DMSO at –1°C/min and stored in liquid nitrogen. Stress-strain relationships of fresh and thawed veins were determined in an uniaxial tension-testing rig. HUV endothelial cells (HUVEC) were seeded onto denuded HUV under static conditions and grown for 3d. Luminal surfaces were analyzed by scanning electron microscopy. Calcein-stained cells were seeded hyperconfluently to determine the cell retention capacity of fresh and cryopreserved veins.
Results: The stress-strain relationships of HUV followed a biphasic pattern typical for natural vessels. Neither the failure stress (2.71±0.36 vs. 3.25±0.97 N, n=3) nor the displacement required to achieve failure (9.73±0.9 vs. 7.43±2.07mm, n=3) were altered by cryopreservation. The burst pressure was estimated as approx. 1000mm Hg within the limitations of the uniaxial model. HUVEC seeded onto denuded HUV formed patches (at 9E3 cells per cm2) or an almost confluent endothelium (at 3E4 cells per cm2) within three days. The capacity to retain seeded HUVEC of denuded HUV was not altered by cryopreservation (1.15±0.08E5 vs. 1.26±0.14E5 cells per cm2, n=6).
Conclusions: The burst pressure of HUV seems to be sufficiently high for the human arterial circulation and is not altered by cryopreservation. HUVEC can establish a confluent endothelium on denuded HUV. Therefore HUV appears to be a suitable storable scaffold for vascular tissue engineering.
A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry.
Medicine Meets Engineering: Proceedings of the 2nd Conference on Applied Biomechanics Regensburg
(2008)
Biomedical Engineering is defined as the science that integrates medical and engineering sciences to improve diagnosis and treatment of patients. Only by this integration progress can be achieved. Both medical and engineering sciences comprise a huge diversity in topics, so it is imaginable that Biomedical Engineering, combining these two science areas, is even more huge. Thanks to this megadisciplinary approach many breakthroughs can be achieved. More and more research groups realize this and start new research projects, which results in a rapid increase in knowledge in Biomedical Engineering. This will only benefit the main goal of Biomedical Engineering; improving diagnosis and treatment of patients when it is spread and applied. The 2nd Regensburg Applied Biomechanics conference is special in that it realized both the distribution of new knowledge and the essential integration of medical and engineering specialists. The conference dealt with the latest results in applied biomechanics, ranging from fundamental bone strength properties via bone remodeling phenomena to new implants that replace lost human functions. Also new research areas like robot surgery and tissue engineering were discussed.
Finite element (FE)–based studies of preoperative processes such as folding,pleating, and stent crimping with a comparison with experimental inflation tests are not yet available. Therefore, a novel workflow is presented in which residual stresses of balloon folding and pleating, as well as stent crimping, and the geometries of all contact partners were ultimately implemented in an FE code to simulate stent expansion by using an implicit solver. The numerical results demonstrate that the incorporation of residual stresses and strains experienced during the production step significantly increased the accuracy of the subsequent simulations, especially of the stent expansion model. During the preoperative processes, stresses inside the membrane and the stent material also reached a rather high level. Hence, there can be no presumption that balloon catheters or stents are undamaged before the actual surgery. The implementation of the realistic geometry, in particular the balloon tapers, and the blades of the process devices improved the simulation of the expansion mech-anisms, such as dogboning, concave bending, or overexpansion of stent cells. This study shows that implicit solvers are able to precisely simulate the mentioned preoperative processes and the stent expansion procedure without a preceding manipulation of the simulation time or physical mass.
Simulation of Fluid-Structure Interaction between injection medium and balloon catheter using ICFD
(2017)
Arteriosclerosis is a major health issue worldwide. While it is commonly treated by the implantation of an balloon-expandable stent, micro injuries may occur during stent deployment, and induce in-stent restenosis, whose consequence can be fatal. Studying this undesirable phenomenon is usually limited as experimental data is hard to obtain on ethical ground. Numerical simulation are performed to better understand this problem. To construct a more realistic simulation of a balloon-expandable stent, a partitioned strongly-coupled FSI simulation of the balloon deployment was set up using the ICFD solver of LS-DYNA, - a quite innovative approach. The complex balloon configuration as well as the interaction of the injection medium and the balloon structure was considered. The balloon structure consisting of shell elements was obtained from preliminary balloon folding and pleating simulations. The balloon consists of a flexible thin walled polyamide. The injection fluid is implemented using volume elements. Balloon deployment was initiated by a pressure boundary condition inducing a volume flow into the balloon. The initial feasibility analysis showed promising result including a continuous balloon deployment and a reasonable development of the fluid pressure and velocity field. However, applying this FSI approach to a more complex balloon structure led to a non convergent solution. The non-convergence could be mainly reduced to mechanical factors including the low wall thickness of the balloon (< 0.05 mm) and the flexibility of the polyamide. Further, the ICFD solver shows less accuracy concerning the FSI conditions when dealing with thin flexible structures as well as enclosed volumes. A shell thickness of 0.06 mm is believed to result in a convergent solution.
Introduction: Previous studies of bone stresses in the human lumbar spine have relied on simplified models when modeling the spinal musculature, even though muscle forces are likely major contributors to the stresses in the vertebral bones. Detailed musculoskeletal spine models have recently become available and show good correlation with experimental findings. A combined inverse dynamics and finite element analysis study was conducted in the lumbar spine to investigate the effects of muscle forces on a detailed musculoskeletal finite element model of the 4th lumbar vertebral body. Materials and Methodology: The muscle forces were computed with a detailed and validated inverse dynamics musculoskeletal spine model in a lifting situation, and were then applied to an orthotropic finite element model of the 4th lumbar vertebra. The results were compared with those from a simplified load case without muscles. Results: In general the von Mises stress was larger by 30%, and even higher when looking at the von Mises stress distribution in the superio-anterior and central part of the vertebral body and in the pedicles. Conclusion: The application of spine muscles to a finite element model showed markedly larger von Mises stress responses in the central and anterior part of the vertebral body, which can be tolerated in the young and healthy spine, but it would increase the risk of compression fractures in the elderly, osteoporotic spine.
We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated 'femur-first' total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated 'femur-first' group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups.
The development of biomimetic robots has gained research interest in the last years as it may both help under-standing processes of motion execution in biological systems as well as developping a novel generation of intelligent and energy efficient robots. However, exact model generation that builds up on observations and robot design is very time intensive. In this paper we present a novel pipeline for co-development of biomimetic hardware and simulation models based on biological Computer Tomography (CT) data. For this purpose we exploit State of the Art rapid prototyping technologies such as 3D Printing and the Neurorobotics Platform for musculoskeletal simulations in virtual environments. The co-development integrates both advantages of virtual and physical experimental models and is expected to increase development speed of controllers that can be tested on the simulated counterpart before application to a printed robot model. We demonstrate the pipeline by generating a one year old infant model as a musculoskeletal simulation model and a print-in-place 3D printed skeleton as a single movable part. Even though we hereonly introduce the initial body generation and only a first testsetup for a modular sensory and control framework, we can clearly spot advantages in terms of rapid model generation and highly biological related models. Engineering costs are reducedand models can be provided to a wide research community for controller testing in an early development phase.
The success of artificial intelligence in medicine is based on the need for large amounts of high quality training data. Sharing of medical image data, however, is often restricted by laws such as doctor-patient confidentiality. Although there are publicly available medical datasets, their quality and quantity are often low. Moreover, datasets are often imbalanced and only represent a fraction of the images generated in hospitals or clinics and can thus usually only be used as training data for specific problems. The introduction of generative adversarial networks (GANs) provides a mean to generate artificial images by training two convolutional networks. This paper proposes a method which uses GANs trained on medical images in order to generate a large number of artificial images that could be used to train other artificial intelligence algorithms. This work is a first step towards alleviating data privacy concerns and being able to publicly share data that still contains a substantial amount of the information in the original private data. The method has been evaluated on several public datasets and quantitative and qualitative tests showing promising results.
In this paper, we address the problem of retrospective color shading correction. An extension of the established gray-level shading correction algorithm based on signal envelope (SE) estimation to color images is developed using principal color components. Compared to the probably most general shading correction algorithm based on entropy minimization, SE estimation does not need any computationally expensive optimization and thus can be implemented more effciently. We tested our new shading correction scheme on artificial as well as real endoscopic images and observed promising results. Additionally, an indepth analysis of the stop criterion used in the SE estimation algorithm is provided leading to the conclusion that a fixed, user-defined threshold is generally not feasible. Thus, we present new ideas how to develop a non-parametric version of the SE estimation algorithm using entropy.
Chest X-Ray (CXR) images as part of a non-invasive diagnosis method are commonly used in today’s medical workflow. In traditional methods, physicians usually use their experience to interpret CXR images, however, there is a large interobserver variance. Computer vision may be used as a standard for assisted diagnosis. In this study, we applied an encoder-decoder neural network architecture for automatic lung region detection. We compared a three-class approach (left lung, right lung, background) and a two-class approach (lung, background). The differentiation of left and right lungs as direct result of a semantic segmentation on basis of neural nets rather than post-processing a lung-background segmentation is done here for the first time. Our evaluation was done on the NIH Chest X-ray dataset, from which 1736 images were extracted and manually annotated. We achieved 94:9% mIoU and 92% mIoU as segmentation quality measures for the two-class-model and the three-class-model, respectively. This result is very promising for the segmentation of lung regions having the simultaneous classification of left and right lung in mind.
Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand.
Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency–Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.
Aims:
The delineation of outer margins of early Barrett's cancer can be challenging even for experienced endoscopists. Artificial intelligence (AI) could assist endoscopists faced with this task. As of date, there is very limited experience in this domain. In this study, we demonstrate the measure of overlap (Dice coefficient = D) between highly experienced Barrett endoscopists and an AI system in the delineation of cancer margins (segmentation task).
Methods:
An AI system with a deep convolutional neural network (CNN) was trained and tested on high-definition endoscopic images of early Barrett's cancer (n = 33) and normal Barrett's mucosa (n = 41). The reference standard for the segmentation task were the manual delineations of tumor margins by three highly experienced Barrett endoscopists. Training of the AI system included patch generation, patch augmentation and adjustment of the CNN weights. Then, the segmentation results from patch classification and thresholding of the class probabilities. Segmentation results were evaluated using the Dice coefficient (D).
Results:
The Dice coefficient (D) which can range between 0 (no overlap) and 1 (complete overlap) was computed only for images correctly classified by the AI-system as cancerous. At a threshold of t = 0.5, a mean value of D = 0.72 was computed.
Conclusions:
AI with CNN performed reasonably well in the segmentation of the tumor region in Barrett's cancer, at least when compared with expert Barrett's endoscopists. AI holds a lot of promise as a tool for better visualization of tumor margins but may need further improvement and enhancement especially in real-time settings.
Based on previous work by our group with manual annotation of visible Barrett oesophagus (BE) cancer images, a real-time deep learning artificial intelligence (AI) system was developed. While an expert endoscopist conducts the endoscopic assessment of BE, our AI system captures random images from the real-time camera livestream and provides a global prediction (classification), as well as a dense prediction (segmentation) differentiating accurately between normal BE and early oesophageal adenocarcinoma (EAC). The AI system showed an accuracy of 89.9% on 14 cases with neoplastic BE.
The growing number of publications on the application of artificial intelligence (AI) in medicine underlines the enormous importance and potential of this emerging field of research.
In gastrointestinal endoscopy, AI has been applied to all segments of the gastrointestinal tract most importantly in the detection and characterization of colorectal polyps. However, AI research has been published also in the stomach and esophagus for both neoplastic and non-neoplastic disorders.
The various technical as well as medical aspects of AI, however, remain confusing especially for non-expert physicians.
This physician-engineer co-authored review explains the basic technical aspects of AI and provides a comprehensive overview of recent publications on AI in gastrointestinal endoscopy. Finally, a basic insight is offered into understanding publications on AI in gastrointestinal endoscopy.
Background: For surgical fixation of bone fractures of the human hand, so-called Kirschner-wires (K-wires) are drilled through bone fragments. Due to the minimally invasive drilling procedures without a view of risk structures like vessels and nerves, a thorough training of young surgeons is necessary. For the development of a virtual reality (VR) based training system, a three-dimensional (3D) printed phantom hand is required. To ensure an intuitive operation, this phantom hand has to be realistic in both, its position relative to the driller as well as in its haptic features. The softest 3D printing material available on the market, however, is too hard to imitate human soft tissue. Therefore, a support-material (SUP) filled metamaterial is used to soften the raw material. Realistic haptic features are important to palpate protrusions of the bone to determine the drilling starting point and angle. An optical real-time tracking is used to transfer position and rotation to the training system.
Methods: A metamaterial already developed in previous work is further improved by use of a new unit cell. Thus, the amount of SUP within the volume can be increased and the tissue is softened further. In addition, the human anatomy is transferred to the entire hand model. A subcutaneous fat layer and penetration of air through pores into the volume simulate shiftability of skin layers. For optical tracking, a rotationally symmetrical marker attached to the phantom hand with corresponding reference marker is developed. In order to ensure trouble-free position transmission, various types of marker point applications are tested.
Results: Several cuboid and forearm sample prints lead to a final 30 centimeter long hand model. The whole haptic phantom could be printed faultless within about 17 hours. The metamaterial consisting of the new unit cell results in an increased SUP share of 4.32%. Validated by an expert surgeon study, this allows in combination with a displacement of the uppermost skin layer a good palpability of the bones. Tracking of the hand marker in dodecahedron design works trouble-free in conjunction with a reference marker attached to the worktop of the training system.
Conclusions: In this work, an optically tracked and haptically correct phantom hand was developed using dual-material 3D printing, which can be easily integrated into a surgical training system.
In this work, we propose the use of single channel Color Co-occurrence Matrices for texture description of Barrett’sEsophagus (BE)and adenocarcinoma images. Further classification using supervised learning techniques, such as Optimum-Path Forest (OPF), Support Vector Machines with Radial Basisunction (SVM-RBF) and Bayesian classifier supports the contextof automatic BE and adenocarcinoma diagnosis. We validated three approaches of classification based on patches, patients and images in two datasets (MICCAI 2015 and Augsburg) using the color-and-texture descriptors and the machine learning techniques. Concerning MICCAI 2015 dataset, the best results were obtained using the blue channel for the descriptors and the supervised OPF for classification purposes in the patch-based approach, with sensitivity nearly to 73% for positive adenocarcinoma identification and specificity close to 77% for BE (non-cancerous) patch classification. Regarding the Augsburg dataset, the most accurate results were also obtained using both OPF classifier and blue channel descriptor for the feature extraction, with sensitivity close to 67% and specificity around to76%. Our work highlights new advances in the related research area and provides a promising technique that combines color and texture information, allied to three different approaches of dataset pre-processing aiming to configure robust scenarios for the classification step.
Work places and conditions strains the human body, both psychologically and biomechanically. In order to analyse working conditions and in the following to improve them, detailed knowledge about the effect of the different stressors on the body is needed. This manuscript discusses methods on how to evaluate biomechanical and mental loading and its effect on the musculoskeletal system. A possible workflow for the analysis is presented.
The number of spinal fusion surgeries is steadily increasing and biomechanical consequences are still in debate. The aim of this study is to provide biomechanical insights into the sagittal balance of the spine and to compare spinal load before and after spinal fusion.
METHOD:
The joint reaction forces of 52 patients were analyzed in proximo-distal and antero-posterior direction from the levels T12-L1 to L5-S1 using musculoskeletal simulations.
RESULTS:
In 104 simulations, pre-surgical forces were equal to post-surgical. The levels L4-L5 and T12-L1, however, showed increased spinal forces compression forces with higher sagittal displacement. Improved restauration of sagittal balance was accompanied by lower spinal load. AP shear stress, interestingly decreased with sagittal imbalance.
CONCLUSION:
Imbalanced spines have a risk of increased compression forces at Th12-L1. L4-L5 always has increased spinal loads. These slides can be retrieved under Electronic Supplementary Material.
A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints.
Musculoskeletal simulations of lumbar spine loading rely on a geometrical representation of the anatomy. However, this data has an inherent inaccuracy. This study evaluates the influence of defined geometrical parameters on lumbar spine loading utilising five parametrised musculoskeletal lumbar spine models for four different postures. The influence of the dimensions of vertebral body, disc, posterior parts of the vertebrae as well as the curvature of the lumbar spine was studied. Additionally, simulations with combinations of selected parameters were conducted. Changes in L4/L5 resultant joint force were used as outcome variable. Variations of the vertebral body height, disc height, transverse process width and the curvature of the lumbar spine were the most influential.
These parameters can be easily acquired from X-rays and should be used to morph a musculoskeletal lumbar spine model for subject-specific approaches with respect to bone geometry. Furthermore, the model was very sensitive to uncommon configurations and therefore, it is advised that stiffness properties of discs and ligaments should be individualised.
Although it has long been presumed that d-amino acids are uncommon in mammalians, substantial amounts of free d-serine have been detected in the mammalian brain. d-Serine has been demonstrated to be an important modulator of glutamatergic neurotransmission and acts as an agonist at the strychnine-insensitive glycine site of N-methyl-d-aspartate receptors. The blood-to-brain transfer of d-serine is thought to be extremely low, and it is assumed that d-serine is generated by isomerization of l-serine in the brain. Stimulated by the observation of a preferred transport of the d-isomer of proline at the blood–brain barrier, we investigated the differential uptake of [3H]-d-serine and [3H]-l-serine in the rat brain 1 h after intravenous injection using quantitative autoradiography. Surprisingly, brain uptake of [3H]-d-serine was significantly higher than that of [3H]-l-serine, indicating a preferred transport of the d-enantiomer of serine at the blood–brain barrier. This finding indicates that exogenous d-serine may have a direct influence on glutamatergic neurotransmission and associated diseases.
Evaluierung von Registrierungsstrategien zur multimodalen 3D-Rekonstruktion von Rattenhirnschnitten
(2006)
In dieser Arbeit werden drei Strategien zur 3D Stapelung von multimodalen Schnittbildern vorgestellt. Die Strategien werden experimentell anhand von Dualtracer-Autoradiographien evaluiert. Dazu werden neue Maße zur Beschreibung der Konsistenz innerhalb einer Modalität und der Konsistenz der Modalitäten untereinander entwickelt, die auf bekannten Registrierungsmetriken basieren. Gerade bezüglich der Konsistenz der Modalitäten untereinander zeigen zwei Strategien die besten Resultate: (1) abwechselnde multimodale Registrierung (2) monomodale Rekonstruktion einer Modalität und multimodale 2D Registrierung der zweiten Modalität.
Objectives: C-11-methionine (MET) is particularly useful in brain tumor diagnosis but unspecific uptake e.g. in cerebral ischemia has been reported (1). The F-18-labeled amino acid O-(2-[F-18]fluoroethyl)-L-tyrosine (FET) shows a similar clinical potential as MET in brain tumor diagnosis but is applicable on a wider clinical scale. The aim of this study was to evaluate the uptake of FET and H-3-MET in focal cortical ischemia in rats by dual tracer autoradiography.
Methods: Focal cortical ischemia was induced in 12 Fisher CDF rats using the photothrombosis model (PT). One day (n=3) , two days (n=5) and 7 days (n=4) after induction of the lesion FET and H-3-MET were injected intravenously. One hour after tracer injection animals were killed, the brains were removed immediately and frozen in 2-methylbutane at -50°C. Brains were cut in coronal sections (thickness: 20 µm) and exposed first to H-3 insensitive photoimager plates to measure FET distribution. After decay of F-18 the distribution of H-3-MET was determined. The autoradiograms were evaluated by regions of interest (ROIs) placed on areas with increased tracer uptake in the PT and the contralateral brain. Lesion to brain ratios (L/B) were calculated by dividing the mean uptake in the lesion and the brain. Based on previous studies in gliomas a L/B ratio > 1.6 was considered as pathological for FET.
Results: Variable increased uptake of both tracers was observed in the PT and its demarcation zone at all stages after PT. The cut-off level of 1.6 for FET was exceeded in 9/12 animals. One day after PT the L/B ratios were 2.0 ± 0.6 for FET vs. 2.1 ± 1.0 for MET (mean ± SD); two days after lesion 2.2 ± 0.7 for FET vs. 2.7 ± 1.0 for MET and 7 days after lesion 2.4 ± 0.4 for FET vs. 2.4 ± 0.1 for MET. In single cases discrepancies in the uptake pattern of FET and MET were observed.
Conclusions: FET like MET may exhibit significant uptake in infarcted areas or the immediate vincinity which has to be considered in the differential diagnosis of unkown brain lesions. The discrepancies in the uptake pattern of FET and MET in some cases indicates either differences in the transport mechanisms of both amino acids or a different affinity for certain cellular components.
Purpose
In 1969, Germany founded a new type of tertiary education institution, the so-called “Universities of Applied Sciences” (UAS). In contrast to traditional universities, UAS are supposed to educate their students based on scientific methods but with a high degree of application orientation (Wissenschaftsrat, 2010). The goal was to generate highly employable graduates. Since then the number of UAS in Germany has risen to 216 in 2018/2019 (Statistisches Bundesamt, 2019). ~45% of all German students start their tertiary education at a UAS (Autorengruppe Bildungsberichterstattung, 2018). UAS graduates are well perceived by domestic employers, enjoy high recruiting rates and attractive salary levels.
The educational model has proven so successful that its approach and underlying philosophy has been replicated under terms such as “cooperative education” or “applied learning” in a vast number of different countries and educational systems around the globe (Altbach, Reisberg, & Rumbley, 2011).
This talk critically describes the key aspects that constitute German UAS’ approaches to industry-oriented applied learning. The findings are relevant for academics, policy makers, and industry representatives to generate ideas on how to improve study curricula, policies, or collaboration between academia and industry.
Method
The approach taken consists of a descriptive and structured account of the key aspects that constitute the study curricula of a UAS from an applied learning perspective. By building on their own experiences as teaching professors and part of a German UAS’ managerial team, the research method taken resembles an action research-oriented approach.
Key Findings
German UAS have numerous application-oriented learning elements in their curricula. These elements are performed inside the university like lab courses but many of these learning elements are carried out in cooperation with industry.
Bachelor programs span over seven semesters. Fundamentals are taught in the first two semesters and from the third semester on, more and more application-oriented lectures and labs become part of the curricula. In the fifth semester, a mandatory internship is integrated in the study program. This internship is carried out either at companies in Germany or abroad. It is the goal of the internship that the students gain first practical experience in a real work environment. The work tasks in internship should be similar to the later professional demands and should contain a project. The students themselves are responsible for finding an appropriate job and organize the administrative aspects around the internship, thus their self-organization skills are advanced. The UAS teaching staff supervises the internships from an academic perspective. This mandatory internship has numerous advantages: students experience real industry environment and they build contacts to later employers thus forming a potential pathway to future employment.
Bachelor and master courses each finish with thesis work. The majority of theses is carried out in companies under university supervision. This is a second chance for the students to accomplish a company project, to gain practical experience and to get in touch with potential employers.
In addition to undergraduate and postgraduate education, German UAS do a lot of applied research together with companies. This applied research can also be the basis for the work of Ph.D students.
Industry representatives are also involved when designing new study programs as consultants and give advice for accreditation and reaccreditation of programs.
All these activities of German universities of applied sciences lead to a high practical relevance of education programs and to a high degree of employability of UAS graduates.
3D rat brain tumors
(2005)