Lebenswissenschaften und Ethik
Refine
Year of publication
Document Type
- Article (106)
- conference proceeding (article) (86)
- conference talk (37)
- conference proceeding (presentation, abstract) (30)
- Part of a Book (4)
- Doctoral Thesis (3)
- Moving Images (2)
- Other (2)
- conference proceeding (volume) (1)
- Edited collection (1)
Is part of the Bibliography
- no (275)
Keywords
- Biomechanik (13)
- Biomechanics (10)
- Simulation (10)
- Hüftgelenkprothese (9)
- Biomechanische Analyse (7)
- Stent (6)
- Bewegungsapparat (4)
- Finite element analysis (4)
- Spongiosa (4)
- biomechanics (4)
- AnyBody (3)
- Computerunterstütztes Verfahren (3)
- Deformation (3)
- ECMO (3)
- Finite-Elemente-Methode (3)
- Gait analysis (3)
- Inverse dynamics (3)
- Lumbar spine (3)
- Musculoskeletal simulation (3)
- Operationstechnik (3)
- Schultergelenk (3)
- THA (3)
- musculoskeletal simulation (3)
- Adhesives (2)
- Aerosols (2)
- Alter (2)
- Anisotropie (2)
- AnyBody Modeling System (2)
- Ballondilatation (2)
- Belastung (2)
- Biomaterial (2)
- Blood Viscosity (2)
- Breast augmentation (2)
- CFD (2)
- Catheters (2)
- Combined anteversion (2)
- Computertomografie (2)
- Coronary stenting (2)
- Flow visualisation (2)
- Implantation (2)
- Knochen (2)
- Knochenbruch (2)
- Lendenwirbelsäule (2)
- Mechanische Belastung (2)
- Membrane Oxygenator (2)
- Musculoskeletal Modeling (2)
- Nasal airflow (2)
- Numerische Strömungssimulation (2)
- Stiffness (2)
- Stress (2)
- Test (2)
- Tissue Engineering (2)
- Tomographic PIV (2)
- computational fluid dynamics (2)
- stem cells (2)
- total hip replacement (2)
- 3D measurement (1)
- 3D scan (1)
- 3D volumetry (1)
- 3D-Druck (1)
- ANEURYSMS (1)
- ANTERIOR CINGULATE CORTEX (1)
- ANTERIOR CRUCIATE LIGAMENT (1)
- APOPTOSIS (1)
- ARTERIES (1)
- ASCORBIC-ACID (1)
- ASIS (1)
- AUGMENTATION (1)
- Abduction tasks (1)
- Accoucheur (1)
- Acetabulum/physiology (1)
- Adaptive clinical trial (1)
- Aerodynamics (1)
- Aerosole (1)
- Altenpflege (1)
- Aluminum Silicates (1)
- Animals (1)
- Anisotropy (1)
- Antibiotika (1)
- Antioxidant (1)
- Arbeitsbedingungen (1)
- Arbeitshilfe (1)
- Assistenzsystem (1)
- Autologous bone graft (1)
- BIOREACTOR (1)
- BLOOD FLOW (1)
- BLOOD-VESSELS (1)
- BYPASS GRAFTS (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Beweglichkeit (1)
- Bewegung (1)
- Bewegungsanalyse (1)
- Bewegungsanalyse <Technik> (1)
- Bildbasierte Verfahren (1)
- Bildgebendes Verfahren (1)
- Bioactivity (1)
- Biological models (1)
- Biologische Modelle (1)
- Biomechanical Phenomena (1)
- Biomechanical investigation (1)
- Blutdruck (1)
- Blutgefäß (1)
- Body Weight (1)
- Bond strength (1)
- Bone harvesting (1)
- Bone imaging (1)
- Bone substitute materials (1)
- Bovine cartilage (1)
- Breast cancer (1)
- Breast implant (1)
- Breathing cycle (1)
- Brusterhaltende Therapie (1)
- Brustkorb (1)
- Brustwirbelsäule (1)
- CANCER (1)
- CELT (1)
- CEUS (1)
- COMPLEX (1)
- CONNECTIVITY (1)
- CONSTRUCTS (1)
- CONTRAST AGENT (1)
- COORDINATE SYSTEM (1)
- COVID-19 (1)
- CULTURES (1)
- Cancellous bone (1)
- Cancer-cells (1)
- Cardiovascular stents (1)
- Cartilage samples (1)
- Catheter (1)
- Ceramics (1)
- Characterisation testing (1)
- Classification (1)
- Coherent motion detection (1)
- Communication engineering education (1)
- Computational Fluid Dynamics Simulation (1)
- Computer-assisted surgery (1)
- Computersimulation (1)
- Computertomographie (1)
- Conventional surgery (1)
- Convolutional neural networks (1)
- Coronary (1)
- Coronary artery (1)
- Corrosion rate (1)
- Corrosion test (1)
- Covid-19 (1)
- Crimping (1)
- Cup medialisation (1)
- DEFICIENCY (1)
- Damage (1)
- Damage mechanism (1)
- Deep Learning (1)
- Deep learning fluid mechanics (1)
- Deformation behaviour (1)
- Dental Materials (1)
- Dental alloys (1)
- Dental membrane (1)
- Dentin (1)
- Depression (1)
- Deutschland (1)
- Distraktion (1)
- Dragonfly (1)
- Dragonfly wing (1)
- Dreidimensionale Bildverarbeitung (1)
- EARLY OSTEOARTHRITIS (1)
- ECMO SYSTEMS (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Elasticity (1)
- Electromyography (1)
- Elektromyographie (1)
- Elite athletes (1)
- Ellenbogenstabilität (1)
- Empfindlichkeit (1)
- Endotracheal Intubation (1)
- Endotracheal Tube (1)
- Equipment Failure Analysis/statistics & numerical data (1)
- Ergonomics (1)
- Ermüdung (1)
- Ermüdungsbruch (1)
- Euler-Bernoulli-Beam-Theory (1)
- Ex vivo porcine stent model (1)
- Extracorporeal Membrane Oxygenation/instrumentation (1)
- FEA (1)
- FORCE (1)
- FRONTAL-CORTEX (1)
- Fat graft (1)
- Fatigue (1)
- Fatigue fracture (1)
- Feedback (1)
- Femur first (1)
- Finite element (1)
- Finite element analysis (FEA) (1)
- Flow (1)
- Fluid Mechanics (1)
- Football (1)
- Functional MRI (1)
- Funktionelle Anatomie (1)
- GAIT (1)
- GULO (1)
- Gait (1)
- Ganganalyse (1)
- Gefäßverletzung (1)
- Gehen (1)
- Geometrical imperfections (1)
- Geometrie (1)
- Germany (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Gliding Flight (1)
- Ground Reaction Force Prediction (1)
- HYDROGELS (1)
- Haltungsfehler (1)
- Haut (1)
- Head trauma (1)
- Heat treatment (1)
- Hemodynamics (1)
- Hip Prosthesis (1)
- Hochschulschrift (1)
- Humans (1)
- Hyaluronsäure (1)
- Hämodynamik (1)
- Hüftgelenk (1)
- Hüftgelenkpfanne (1)
- IMMEDIATE BREAST RECONSTRUCTION (1)
- IMU (1)
- IN-VITRO (1)
- INFLAMMATION (1)
- INJURY (1)
- INSTABILITY (1)
- Iliac crest (1)
- Indentation test (1)
- Indian ink (1)
- Inertial Measurement Units (1)
- Injury score (1)
- Internal fixator (1)
- Ion release (1)
- Joint Reaction Forces (1)
- Kardiovaskuläres System (1)
- Kennzeichnung (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenbildung (1)
- Knochenentnahme (1)
- Knochenersatz (1)
- Knorpel (1)
- Knowledge engineering (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Koronare Herzkrankheit (1)
- Koronarendoprothese (1)
- Körper (1)
- Körperliche Belastung (1)
- Künstliche Intelligenz (1)
- Laser powder bed fusion (L-PBF) (1)
- Lasers (1)
- Lastverteilung <Statik> (1)
- Le Fort III (1)
- Leg length (1)
- Leistungssportler (1)
- Leitfähgkeit (1)
- Lendenwirbelsäulenkrankheit (1)
- Ligament stiffness (1)
- Linear Models (1)
- Lipofilling (1)
- MAMMAPLASTY (1)
- MDCT (1)
- MECHANICAL PROPERTIES (1)
- MECHANICAL-PROPERTIES (1)
- MEDICINAL PLANTS (1)
- MITOCHONDRIAL DYSFUNCTION (1)
- MOTION (1)
- MRI (1)
- MULTIDETECTOR COMPUTED-TOMOGRAPHY (1)
- Magnesium (1)
- Mammoplastik (1)
- Material properties (1)
- Measurement and testing (1)
- Mechanical Phenomena (1)
- Mechanical behaviour (1)
- Mechanical properties (1)
- Medizintechnik (1)
- Mehrkörpersimulation (1)
- Membrane/classification/standards/statistics & numerical data (1)
- Meniskusschaden (1)
- Mensch (1)
- Mesenchymzelle (1)
- Method labeling (1)
- Micro-structure (1)
- Minimal-invasive Chirurgie (1)
- Modell (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Movement (1)
- Multibody Simulation (1)
- Multiphase blood flow (1)
- Multiresistant (1)
- Mund-Kiefer-Gesichts-Chirurgie (1)
- Muscle (1)
- Muscle influence (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscles (1)
- Muscoloskeletal model (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskelkraft (1)
- Muskuloskelettale Simulation (1)
- Nabelvene (1)
- Nachweis (1)
- Nanoparticles (1)
- Non-Newtonian multiphase flow (1)
- Numerische Methode (1)
- OSTEOARTHRITIS (1)
- OUTCOMES (1)
- OXIDATIVE STRESS (1)
- OXYGENATION (1)
- Offset (1)
- Orthopädische Chirurgie (1)
- Osteoconductive (1)
- Osteomyelitis (1)
- Osteosynthese (1)
- Osteotomie (1)
- Outcome (1)
- PCR (1)
- PHOSPHATIDYLCHOLINE (1)
- PLATELET ACTIVATION (1)
- PLATELET-RICH PLASMA (1)
- POLYPHENOLS (1)
- PREDICTOR (1)
- Pandemie (1)
- Parameter study (1)
- Particle Image Velocimetry (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Perceptual learning (1)
- Percutaneous coronary intervention (1)
- Physiological Breathing (1)
- Polymer (1)
- Polymerase-Kettenreaktion (1)
- Polymers (1)
- Powders (1)
- Precious alloys (1)
- Primary Health Care/statistics & numerical data (1)
- Prognose (1)
- Prosthesis Design (1)
- Prüfung (1)
- Pulleys (1)
- QUANTIFICATION (1)
- RADIATION-THERAPY (1)
- RECIPIENT-SITE (1)
- RTMS (1)
- Radiotherapy (1)
- Randomized (1)
- Rapamycin (1)
- Rapid prototyping (1)
- Reconstruction (1)
- Resilience, psychological (1)
- Resilienz, psychologische (1)
- Resistance to corrosion (1)
- Respiratory Distress Syndrome/therapy (1)
- Restenosis (1)
- Retrospective Studies (1)
- Rind (1)
- Robot sensing systems (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- SARS-CoV-2 (1)
- SHAPE (1)
- STIFFNESS (1)
- STIMULATION (1)
- Sagittal balance (1)
- Schulkind (1)
- Schädel-Hirn-Trauma (1)
- Second-harmonic generation imaging (1)
- Severity of Illness Index (1)
- Shear Raed Induced Coagulation (1)
- Shear Rate Induced Coagulation (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Silent Breathing (1)
- Softening (1)
- Specimen preparation and treatment (1)
- Speedcourt (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Stabilität (1)
- Steifigkeit (1)
- Stent design (1)
- Stent implantation (1)
- Stent screening (1)
- Stent-artery interaction (1)
- Stents (1)
- Stress, Mechanical (1)
- Surface Properties (1)
- Surface treatments (1)
- Surgical smoke (1)
- T-peel configuration (1)
- THR (1)
- THROMBOSIS (1)
- THROMBOTIC DEPOSITS (1)
- TMS (1)
- Task analysis (1)
- Testing biomaterials (1)
- Thoracolumbar spine (1)
- Time factors (1)
- Tinte (1)
- Topographic shift (1)
- Torus (1)
- Total hip athroplasty (1)
- Tracheotomies (1)
- Transfer functions (1)
- Turbulent Kinetic Energy (1)
- Valves (1)
- Vascular injury (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vertebra (1)
- Violinspiel (1)
- Viscoelasticity (1)
- Webcast (1)
- Werkstoff (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- aerodynamics (1)
- anchorage (1)
- anti-Inflammatory agent (1)
- attention (1)
- biomaterial (1)
- biomechanical implant test (1)
- blood (1)
- bone biomechanics (1)
- brain mapping (1)
- cancer (1)
- cell- free DNA (1)
- cell-enriched lipotransfer (1)
- chemical synthesis (1)
- children (1)
- chondrocytes (1)
- coagulation (1)
- collagen (1)
- combined anteversion (1)
- component position (1)
- computer-assisted orthopaedic surgery (1)
- cortical plasticity (1)
- critical hip joint loading (1)
- crosstalk (1)
- cup loading (1)
- data-driven analysis (1)
- design (1)
- distraction (1)
- drug-eluting stent (1)
- dynamic multiplanar loading (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- enhanced resorption (1)
- esb (1)
- extracellular matrix (1)
- fMRI BOLD (1)
- fat grafting (1)
- femoral fracture (1)
- femoral offset (1)
- finite elements analysis (1)
- flexibility ellipsis (1)
- force angles (1)
- force pathways (1)
- form-finding (1)
- functional outcome (1)
- functionality (1)
- gait analysis (1)
- gargle (1)
- gliding flight (1)
- happiness (1)
- high-impact exercisess (1)
- hip contact force (1)
- hip fractureg (1)
- histological evaluation (1)
- human articular cartilage (1)
- human umbilical vein (1)
- humeroradial stability (1)
- hydrogels (1)
- immune system (1)
- implant migration (1)
- inertial measurement units (1)
- infiltration (1)
- inflammation (1)
- influence parameters (1)
- insect flight (1)
- kinematics (1)
- language assessment (1)
- ligaments (1)
- lipoaspirate (1)
- lipograft (1)
- liposomal packing (1)
- lower back load (1)
- lumbar geometry (1)
- lumbar spine (1)
- macular degeneration (1)
- mechanical compliance (1)
- membrane lung (1)
- meniscus (1)
- multifidus (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- neutrophil extracellular traps (1)
- optical motion capture (1)
- osteoarthritis (1)
- osteoporosis (1)
- pandemic (1)
- patient specific loading (1)
- pelvic floor (1)
- pelvic tilt (1)
- perceptual learning (1)
- pharmacology (1)
- pooling (1)
- proteolysis (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rapamycin (1)
- resting-state fMRI (1)
- rheological model (1)
- rim loading (1)
- sadness (1)
- scaffolds (1)
- schools (1)
- sensitivity study (1)
- sensors (1)
- shear induced clotting (1)
- shoulder elevation (1)
- shoulder joint force (1)
- simplified loading model (1)
- sirolimus (1)
- small calibre graft (1)
- sonography (1)
- stent platform (1)
- subject-specific musculoskeletal modeling (1)
- subluxation (1)
- surface electromyography (1)
- surgery (1)
- tannic acid (1)
- task-based fMRI (1)
- tensegrity joint (1)
- therapeutic use (1)
- three-dimensional computed tomography analysis (1)
- tissue engineering (1)
- tissue regeneration (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- toxicity (1)
- tracheobronchial mucus (1)
- vWF (1)
- validation (1)
- vascular tissue engineering (1)
- vector (1)
- violin (1)
- viscoelasticity (1)
- visual cortex (1)
- vitamin C (1)
- von Willebrand factor (1)
- wearable motion-tracking sensors (1)
- white adipose tissue (1)
- zwitterionic monomers (1)
- µCT (1)
Institute
- Fakultät Maschinenbau (275) (remove)
Begutachtungsstatus
- peer-reviewed (98)
- begutachtet (10)
High loads can appear in the individual joints of the human foot while the driver uses the pedals, in particular, during breaking. Measuring these internal forces is very difficult or almost impossible; therefore, advanced models are necessary to perform musculoskeletal simulations. The objective of this investigation was to see what loads are acting in the individual foot joints from the phalanges to calcaneus and talus during different brake scenarios. The Glasgow-Maastricht AnyBody Foot Model with 26 separate segments, connected by joints, ligaments and muscles was used inside the AnyBody Modeling System to compute individual mid foot joint loads. The amount, the direction of the force and additionally also the load insertion point was varied for several simulations. Figure 1: Seated musculoskeletal body model with applied brake force and forces for the lateral, intermediate and medial cuneiform-navicular joint for two different brake forces. The simulation showed that for the different brake scenarios, different muscles will be activated in the human and therefore different loads are apply in the fore-and mid-foot, respectively. The torso of the subject was assumed to be fixed in the seat. Further studies are ongoing to simulate the seat as an elastic element that allows different H-point locations according to the different loadings in the foot from the brake pedal using a new inverse dynamics analysis method called force-dependent kinematics.
Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.
Für Fußballer:innen stellen muskuläre Verletzungen der unteren Extremitäten ein großes Problem dar. Ein Beispiel hierfür liefert die Nationalmannschaftsstürmerin Alexandra Popp, die aufgrund muskulärer Probleme das EM-Finale 2022 in Wembley kurzfristig verpasste. Oftmals stehen gerade hohe Anspannungssituationen in zeitlichem Zusammenhang mit Verletzungen, der Einfluss der psychischen Beanspruchung auf die biomechanischen Belastungen wird jedoch meist nur wenig beachtet.
Soccer is one of the most popular sports all around the world. It is an injurious type of sport with a focus on lower extremities and high psychological pressure during matches. The stressor is linked with injuries and an increased musculoskeletal loading. This study investigates the influence of cognitive stress on the load profile of the knee joint. Twelve professional youth soccer players performed highly dynamic runs with and without additional cognitive stress. The runs were analysed with a musculoskeletal simulation software. The data analysis shows no difference in knee joint reaction loading under additional mental stress compared to the baseline. Yet running times are significantly lower in the baseline. While there is no increase in the joint loads, the running times indicate an altered movement behaviour when the subjects are exposed to additional mental demand.
Mental stress reduces performance and changes musculoskeletal loading in football-related movements
(2020)
Purpose:
Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Hence, this study investigated the musculoskeletal response of elite youth football players during highly dynamic movements under stress. The hypothesis is that mental stress reduces performance and changes the muscular forces exerted.
Materials & methods:
Twelve elite youth football players were subjected to mental stress while performing sports-specific change-of-direction movements. A modified version of the d2 attention test was used as stressor. The kinetics are computed using inverse dynamics. Running times and exerted forces of injury-prone muscles were analysed.
Results:
The stressor runs were rated more mentally demanding by the players (p = 0.006, rs = 0.37) with unchanged physical demand (p = 0.777, rs = 0.45). This resulted in 10% longer running times under stress (p < 0.001, d = −1.62). The musculoskeletal analysis revealed higher peak muscle forces under mental stress for some players but not for others.
Discussion:
The study shows that motion capture combined with musculoskeletal computation is suitable to analyse the effects of stress on athletes in highly dynamic movements. For the first time in football medicine, our data quantifies an association between mental stress with reduced football players’ performance and changes in muscle force.
Evaluation of muscle recruitment and muscle models in musculoskeletal simulation of dynamic motion
(2021)
Musculoskeletal simulation plays an increasingly important role in sports biomechanics. In the last years, the field of application widened from orthopaedics and ergonomics to sports [1]. A muscle recruitment algorithm with a quadratic objective function is usually used to calculate muscle activity in dynamic movements. The agreement of calculated and measured thigh muscle activity has already been investigated [2]. They found a strong agreement for sprinting and running, while the correlation decreased for side-cutting manoeuvres. Nevertheless, the influence of different muscle recruitment criteria on muscle activity in dynamic musculoskeletal simulations is currently unknown. Hence, this study aimed to analyse the effect of different muscle recruitment criteria and muscle models on the correlation of numerical and measured muscle activity in highly dynamic movements.
Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.
Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose.
Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling.
Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics
(2024)
BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research.
METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems.
RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements.
CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models.
BACKGROUND:
Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG.
OBJECTIVE:
This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS:
For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets.
RESULTS:
The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account.
CONCLUSIONS:
Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough.
Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach.
Musculoskeletal modelling of the shoulder – effects on muscle recruitment and joint reaction force
(2019)
The gold standard for the analysis of human kinematics and kinetics is a camera-based motion capture system in combination with force measurement platforms. Alternatively, inertial measurement units can be utilized to obtain human kinematics, while ground reaction forces are computed from full body dynamics. This setup represents a system independent from the spatial confinement of a gait laboratory. The aim of this study is the comparison of the two methods by the investigation of lower limb kinematics and the resulting joint reaction forces within the ankle-, knee- and hip joints. For this purpose, human motion during gait was captured simultaneously by both measurement techniques. 13 trials from 8 different test subjects were evaluated in total. IMU data was processed with a quaternion based Kalman Filter. The data sets were implemented into a musculoskeletal simulation program in order to drive a virtual human body model. Each sensor was aligned to the gravitational and magnetic field vectors of the earth. The angles of flexions, extensions and rotations were analyzed to determine kinematic differences. Joint reaction forces defined kinetic dissimilarities. The overall kinematic differences of both models yielded root mean square errors of 7.62°, 6.02°, 4.95°, 2.79°, 2.38° and 3.56° for ankle flexion, subtalar eversion, knee flexion, hip external rotation, hip abduction and hip flexion, respectively. The proximo-distal differences in force peaks between the models yielded overall for the ankle, 57.33 %Bodyweight(BW) ± 46.86 %BW (16.66 %(Maximum peak to peak) ± 13.62 %) for the knee 37.09 %BW ± 29.33 %BW (17.65 % ± 15.44 %) and 32.03 %BW ± 24.33 %BW (15.6 % ± 12.54 %) for the hip. The overall outcome of this work investigated an approach independent of the common setup of the gait laboratory, thus enabling a cheaper and more flexible technology as an alternative. However, kinematic and thus kinetic differences remain rather large. Future work aims to improve the contact criterion for the calculation of the ground reaction forces and the implementation of a full-body calibration algorithm for the IMU system in order to counteract magnetic field disturbances.
Musculoskeletal models of the shoulder complex are valuable research aids to investigate tears of the supraspinatus and the resulting mechanical impact during abduction of the humerus. One of the major contributors to this motion is the deltoid muscle group and for this, an accurate modeling of the lines of action is indispensable. The aim of this work was to utilize a torus obstacle wrapping approach for the deltoids of an existing shoulder model and assess the feasibility of the approach during humeral abduction. The shoulder model from the AnyBody™ modeling system was used as a platform. The size of the tori is based on a magnetic resonance imaging (MRI) approach and several kinematic couplings are implemented to determine the trajectories of the tori during abduction. To assess the model behavior, the moment arms of the virtual muscle elements and the resultant glenohumeral joint reaction force (GHJF) were compared with reference data from the literature during abduction of the humerus in the range 20°–120°. The root mean square error for the anterior, lateral and posterior part between the simulated muscle elements and reference data from the literature was 3.9, 1.7 and 5.8 mm, respectively. The largest deviation occurred on the outer elements of the muscle groups, with 12.6, 10.4 and 20.5 mm, respectively. During abduction, there is no overlapping of the muscle elements and these are in continuous contact with the torus obstacles, thus enabling a continuous force transmission. This results in a rising trend of the resultant GHJF.
The torus obstacle approach as a wrapping method for the deltoid muscles provides a guided muscle pathing by simultaneously approximating the curvature of the deltoid muscle. The results from the comparison of the simulated moment arms and the resultant GHJF are in accordance with those in the literature in the range 20°–120° of abduction.
Although this study shows the strength of the torus obstacle as a wrapping approach, the method of fitting the tori according to MRI data was not suitable. A cadaver study is recommended to better validate and mathematically describe the torus approach.
Degradation and release of tannic acid from an injectable tissue regeneration bead matrix in vivo
(2021)
The development of multifunctional biomaterials as both tissue regeneration and drug delivery devices is currently a major focus in biomedical research. Tannic Acid (TA), a naturally occurring plant polyphenol, displays unique medicinal abilities as an antioxidant, an antibiotic, and as an anticancer agent. TA has applications in biomaterials acting as a crosslinker in polymer hydrogels improving thermal stability and mechanical properties. We have developed injectable cell seeded collagen beads crosslinked with TA for breast reconstruction and anticancer activity following lumpectomy. This study determined the longevity of the bead implants by establishing a degradation time line and TA release profile in vivo. Beads crosslinked with 0.1% TA and 1% TA were compared to observe the differences in TA concentration on degradation and release. We found collagen/TA beads degrade at similar rates in vivo, yet are resistant to complete degradation after 16 weeks. TA is released over time in vivo through diffusion and cellular activity. Changes in mechanical properties in collagen/TA beads before implantation to after 8 weeks in vivo also indicate loss of TA over a longer period of time. Elastic moduli decreased uniformly in both 0.1% and 1% TA beads. This study establishes that collagen/TA materials can act as a drug delivery system, rapidly releasing TA within the first week following implantation. However, the beads retain TA long term allowing them to resist degradation and remain in situ acting as a cell scaffold and tissue filler. This confirms its potential use as an anticancer and minimally invasive breast reconstructive device following lumpectomy.