Lebenswissenschaften und Ethik
Refine
Year of publication
Document Type
- Article (106)
- conference proceeding (article) (86)
- conference talk (37)
- conference proceeding (presentation, abstract) (30)
- Part of a Book (4)
- Doctoral Thesis (3)
- Moving Images (2)
- Other (2)
- conference proceeding (volume) (1)
- Edited collection (1)
Is part of the Bibliography
- no (275)
Keywords
- Biomechanik (13)
- Biomechanics (10)
- Simulation (10)
- Hüftgelenkprothese (9)
- Biomechanische Analyse (7)
- Stent (6)
- Bewegungsapparat (4)
- Finite element analysis (4)
- Spongiosa (4)
- biomechanics (4)
- AnyBody (3)
- Computerunterstütztes Verfahren (3)
- Deformation (3)
- ECMO (3)
- Finite-Elemente-Methode (3)
- Gait analysis (3)
- Inverse dynamics (3)
- Lumbar spine (3)
- Musculoskeletal simulation (3)
- Operationstechnik (3)
- Schultergelenk (3)
- THA (3)
- musculoskeletal simulation (3)
- Adhesives (2)
- Aerosols (2)
- Alter (2)
- Anisotropie (2)
- AnyBody Modeling System (2)
- Ballondilatation (2)
- Belastung (2)
- Biomaterial (2)
- Blood Viscosity (2)
- Breast augmentation (2)
- CFD (2)
- Catheters (2)
- Combined anteversion (2)
- Computertomografie (2)
- Coronary stenting (2)
- Flow visualisation (2)
- Implantation (2)
- Knochen (2)
- Knochenbruch (2)
- Lendenwirbelsäule (2)
- Mechanische Belastung (2)
- Membrane Oxygenator (2)
- Musculoskeletal Modeling (2)
- Nasal airflow (2)
- Numerische Strömungssimulation (2)
- Stiffness (2)
- Stress (2)
- Test (2)
- Tissue Engineering (2)
- Tomographic PIV (2)
- computational fluid dynamics (2)
- stem cells (2)
- total hip replacement (2)
- 3D measurement (1)
- 3D scan (1)
- 3D volumetry (1)
- 3D-Druck (1)
- ANEURYSMS (1)
- ANTERIOR CINGULATE CORTEX (1)
- ANTERIOR CRUCIATE LIGAMENT (1)
- APOPTOSIS (1)
- ARTERIES (1)
- ASCORBIC-ACID (1)
- ASIS (1)
- AUGMENTATION (1)
- Abduction tasks (1)
- Accoucheur (1)
- Acetabulum/physiology (1)
- Adaptive clinical trial (1)
- Aerodynamics (1)
- Aerosole (1)
- Altenpflege (1)
- Aluminum Silicates (1)
- Animals (1)
- Anisotropy (1)
- Antibiotika (1)
- Antioxidant (1)
- Arbeitsbedingungen (1)
- Arbeitshilfe (1)
- Assistenzsystem (1)
- Autologous bone graft (1)
- BIOREACTOR (1)
- BLOOD FLOW (1)
- BLOOD-VESSELS (1)
- BYPASS GRAFTS (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Beweglichkeit (1)
- Bewegung (1)
- Bewegungsanalyse (1)
- Bewegungsanalyse <Technik> (1)
- Bildbasierte Verfahren (1)
- Bildgebendes Verfahren (1)
- Bioactivity (1)
- Biological models (1)
- Biologische Modelle (1)
- Biomechanical Phenomena (1)
- Biomechanical investigation (1)
- Blutdruck (1)
- Blutgefäß (1)
- Body Weight (1)
- Bond strength (1)
- Bone harvesting (1)
- Bone imaging (1)
- Bone substitute materials (1)
- Bovine cartilage (1)
- Breast cancer (1)
- Breast implant (1)
- Breathing cycle (1)
- Brusterhaltende Therapie (1)
- Brustkorb (1)
- Brustwirbelsäule (1)
- CANCER (1)
- CELT (1)
- CEUS (1)
- COMPLEX (1)
- CONNECTIVITY (1)
- CONSTRUCTS (1)
- CONTRAST AGENT (1)
- COORDINATE SYSTEM (1)
- COVID-19 (1)
- CULTURES (1)
- Cancellous bone (1)
- Cancer-cells (1)
- Cardiovascular stents (1)
- Cartilage samples (1)
- Catheter (1)
- Ceramics (1)
- Characterisation testing (1)
- Classification (1)
- Coherent motion detection (1)
- Communication engineering education (1)
- Computational Fluid Dynamics Simulation (1)
- Computer-assisted surgery (1)
- Computersimulation (1)
- Computertomographie (1)
- Conventional surgery (1)
- Convolutional neural networks (1)
- Coronary (1)
- Coronary artery (1)
- Corrosion rate (1)
- Corrosion test (1)
- Covid-19 (1)
- Crimping (1)
- Cup medialisation (1)
- DEFICIENCY (1)
- Damage (1)
- Damage mechanism (1)
- Deep Learning (1)
- Deep learning fluid mechanics (1)
- Deformation behaviour (1)
- Dental Materials (1)
- Dental alloys (1)
- Dental membrane (1)
- Dentin (1)
- Depression (1)
- Deutschland (1)
- Distraktion (1)
- Dragonfly (1)
- Dragonfly wing (1)
- Dreidimensionale Bildverarbeitung (1)
- EARLY OSTEOARTHRITIS (1)
- ECMO SYSTEMS (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Elasticity (1)
- Electromyography (1)
- Elektromyographie (1)
- Elite athletes (1)
- Ellenbogenstabilität (1)
- Empfindlichkeit (1)
- Endotracheal Intubation (1)
- Endotracheal Tube (1)
- Equipment Failure Analysis/statistics & numerical data (1)
- Ergonomics (1)
- Ermüdung (1)
- Ermüdungsbruch (1)
- Euler-Bernoulli-Beam-Theory (1)
- Ex vivo porcine stent model (1)
- Extracorporeal Membrane Oxygenation/instrumentation (1)
- FEA (1)
- FORCE (1)
- FRONTAL-CORTEX (1)
- Fat graft (1)
- Fatigue (1)
- Fatigue fracture (1)
- Feedback (1)
- Femur first (1)
- Finite element (1)
- Finite element analysis (FEA) (1)
- Flow (1)
- Fluid Mechanics (1)
- Football (1)
- Functional MRI (1)
- Funktionelle Anatomie (1)
- GAIT (1)
- GULO (1)
- Gait (1)
- Ganganalyse (1)
- Gefäßverletzung (1)
- Gehen (1)
- Geometrical imperfections (1)
- Geometrie (1)
- Germany (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Gliding Flight (1)
- Ground Reaction Force Prediction (1)
- HYDROGELS (1)
- Haltungsfehler (1)
- Haut (1)
- Head trauma (1)
- Heat treatment (1)
- Hemodynamics (1)
- Hip Prosthesis (1)
- Hochschulschrift (1)
- Humans (1)
- Hyaluronsäure (1)
- Hämodynamik (1)
- Hüftgelenk (1)
- Hüftgelenkpfanne (1)
- IMMEDIATE BREAST RECONSTRUCTION (1)
- IMU (1)
- IN-VITRO (1)
- INFLAMMATION (1)
- INJURY (1)
- INSTABILITY (1)
- Iliac crest (1)
- Indentation test (1)
- Indian ink (1)
- Inertial Measurement Units (1)
- Injury score (1)
- Internal fixator (1)
- Ion release (1)
- Joint Reaction Forces (1)
- Kardiovaskuläres System (1)
- Kennzeichnung (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenbildung (1)
- Knochenentnahme (1)
- Knochenersatz (1)
- Knorpel (1)
- Knowledge engineering (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Koronare Herzkrankheit (1)
- Koronarendoprothese (1)
- Körper (1)
- Körperliche Belastung (1)
- Künstliche Intelligenz (1)
- Laser powder bed fusion (L-PBF) (1)
- Lasers (1)
- Lastverteilung <Statik> (1)
- Le Fort III (1)
- Leg length (1)
- Leistungssportler (1)
- Leitfähgkeit (1)
- Lendenwirbelsäulenkrankheit (1)
- Ligament stiffness (1)
- Linear Models (1)
- Lipofilling (1)
- MAMMAPLASTY (1)
- MDCT (1)
- MECHANICAL PROPERTIES (1)
- MECHANICAL-PROPERTIES (1)
- MEDICINAL PLANTS (1)
- MITOCHONDRIAL DYSFUNCTION (1)
- MOTION (1)
- MRI (1)
- MULTIDETECTOR COMPUTED-TOMOGRAPHY (1)
- Magnesium (1)
- Mammoplastik (1)
- Material properties (1)
- Measurement and testing (1)
- Mechanical Phenomena (1)
- Mechanical behaviour (1)
- Mechanical properties (1)
- Medizintechnik (1)
- Mehrkörpersimulation (1)
- Membrane/classification/standards/statistics & numerical data (1)
- Meniskusschaden (1)
- Mensch (1)
- Mesenchymzelle (1)
- Method labeling (1)
- Micro-structure (1)
- Minimal-invasive Chirurgie (1)
- Modell (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Movement (1)
- Multibody Simulation (1)
- Multiphase blood flow (1)
- Multiresistant (1)
- Mund-Kiefer-Gesichts-Chirurgie (1)
- Muscle (1)
- Muscle influence (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscles (1)
- Muscoloskeletal model (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskelkraft (1)
- Muskuloskelettale Simulation (1)
- Nabelvene (1)
- Nachweis (1)
- Nanoparticles (1)
- Non-Newtonian multiphase flow (1)
- Numerische Methode (1)
- OSTEOARTHRITIS (1)
- OUTCOMES (1)
- OXIDATIVE STRESS (1)
- OXYGENATION (1)
- Offset (1)
- Orthopädische Chirurgie (1)
- Osteoconductive (1)
- Osteomyelitis (1)
- Osteosynthese (1)
- Osteotomie (1)
- Outcome (1)
- PCR (1)
- PHOSPHATIDYLCHOLINE (1)
- PLATELET ACTIVATION (1)
- PLATELET-RICH PLASMA (1)
- POLYPHENOLS (1)
- PREDICTOR (1)
- Pandemie (1)
- Parameter study (1)
- Particle Image Velocimetry (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Perceptual learning (1)
- Percutaneous coronary intervention (1)
- Physiological Breathing (1)
- Polymer (1)
- Polymerase-Kettenreaktion (1)
- Polymers (1)
- Powders (1)
- Precious alloys (1)
- Primary Health Care/statistics & numerical data (1)
- Prognose (1)
- Prosthesis Design (1)
- Prüfung (1)
- Pulleys (1)
- QUANTIFICATION (1)
- RADIATION-THERAPY (1)
- RECIPIENT-SITE (1)
- RTMS (1)
- Radiotherapy (1)
- Randomized (1)
- Rapamycin (1)
- Rapid prototyping (1)
- Reconstruction (1)
- Resilience, psychological (1)
- Resilienz, psychologische (1)
- Resistance to corrosion (1)
- Respiratory Distress Syndrome/therapy (1)
- Restenosis (1)
- Retrospective Studies (1)
- Rind (1)
- Robot sensing systems (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- SARS-CoV-2 (1)
- SHAPE (1)
- STIFFNESS (1)
- STIMULATION (1)
- Sagittal balance (1)
- Schulkind (1)
- Schädel-Hirn-Trauma (1)
- Second-harmonic generation imaging (1)
- Severity of Illness Index (1)
- Shear Raed Induced Coagulation (1)
- Shear Rate Induced Coagulation (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Silent Breathing (1)
- Softening (1)
- Specimen preparation and treatment (1)
- Speedcourt (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Stabilität (1)
- Steifigkeit (1)
- Stent design (1)
- Stent implantation (1)
- Stent screening (1)
- Stent-artery interaction (1)
- Stents (1)
- Stress, Mechanical (1)
- Surface Properties (1)
- Surface treatments (1)
- Surgical smoke (1)
- T-peel configuration (1)
- THR (1)
- THROMBOSIS (1)
- THROMBOTIC DEPOSITS (1)
- TMS (1)
- Task analysis (1)
- Testing biomaterials (1)
- Thoracolumbar spine (1)
- Time factors (1)
- Tinte (1)
- Topographic shift (1)
- Torus (1)
- Total hip athroplasty (1)
- Tracheotomies (1)
- Transfer functions (1)
- Turbulent Kinetic Energy (1)
- Valves (1)
- Vascular injury (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vertebra (1)
- Violinspiel (1)
- Viscoelasticity (1)
- Webcast (1)
- Werkstoff (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- aerodynamics (1)
- anchorage (1)
- anti-Inflammatory agent (1)
- attention (1)
- biomaterial (1)
- biomechanical implant test (1)
- blood (1)
- bone biomechanics (1)
- brain mapping (1)
- cancer (1)
- cell- free DNA (1)
- cell-enriched lipotransfer (1)
- chemical synthesis (1)
- children (1)
- chondrocytes (1)
- coagulation (1)
- collagen (1)
- combined anteversion (1)
- component position (1)
- computer-assisted orthopaedic surgery (1)
- cortical plasticity (1)
- critical hip joint loading (1)
- crosstalk (1)
- cup loading (1)
- data-driven analysis (1)
- design (1)
- distraction (1)
- drug-eluting stent (1)
- dynamic multiplanar loading (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- enhanced resorption (1)
- esb (1)
- extracellular matrix (1)
- fMRI BOLD (1)
- fat grafting (1)
- femoral fracture (1)
- femoral offset (1)
- finite elements analysis (1)
- flexibility ellipsis (1)
- force angles (1)
- force pathways (1)
- form-finding (1)
- functional outcome (1)
- functionality (1)
- gait analysis (1)
- gargle (1)
- gliding flight (1)
- happiness (1)
- high-impact exercisess (1)
- hip contact force (1)
- hip fractureg (1)
- histological evaluation (1)
- human articular cartilage (1)
- human umbilical vein (1)
- humeroradial stability (1)
- hydrogels (1)
- immune system (1)
- implant migration (1)
- inertial measurement units (1)
- infiltration (1)
- inflammation (1)
- influence parameters (1)
- insect flight (1)
- kinematics (1)
- language assessment (1)
- ligaments (1)
- lipoaspirate (1)
- lipograft (1)
- liposomal packing (1)
- lower back load (1)
- lumbar geometry (1)
- lumbar spine (1)
- macular degeneration (1)
- mechanical compliance (1)
- membrane lung (1)
- meniscus (1)
- multifidus (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- neutrophil extracellular traps (1)
- optical motion capture (1)
- osteoarthritis (1)
- osteoporosis (1)
- pandemic (1)
- patient specific loading (1)
- pelvic floor (1)
- pelvic tilt (1)
- perceptual learning (1)
- pharmacology (1)
- pooling (1)
- proteolysis (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rapamycin (1)
- resting-state fMRI (1)
- rheological model (1)
- rim loading (1)
- sadness (1)
- scaffolds (1)
- schools (1)
- sensitivity study (1)
- sensors (1)
- shear induced clotting (1)
- shoulder elevation (1)
- shoulder joint force (1)
- simplified loading model (1)
- sirolimus (1)
- small calibre graft (1)
- sonography (1)
- stent platform (1)
- subject-specific musculoskeletal modeling (1)
- subluxation (1)
- surface electromyography (1)
- surgery (1)
- tannic acid (1)
- task-based fMRI (1)
- tensegrity joint (1)
- therapeutic use (1)
- three-dimensional computed tomography analysis (1)
- tissue engineering (1)
- tissue regeneration (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- toxicity (1)
- tracheobronchial mucus (1)
- vWF (1)
- validation (1)
- vascular tissue engineering (1)
- vector (1)
- violin (1)
- viscoelasticity (1)
- visual cortex (1)
- vitamin C (1)
- von Willebrand factor (1)
- wearable motion-tracking sensors (1)
- white adipose tissue (1)
- zwitterionic monomers (1)
- µCT (1)
Institute
- Fakultät Maschinenbau (275) (remove)
Begutachtungsstatus
- peer-reviewed (98)
- begutachtet (10)
Einführung in die Mechanik
(2013)
The development of biomimetic robots has gained research interest in the last years as it may both help under-standing processes of motion execution in biological systems as well as developping a novel generation of intelligent and energy efficient robots. However, exact model generation that builds up on observations and robot design is very time intensive. In this paper we present a novel pipeline for co-development of biomimetic hardware and simulation models based on biological Computer Tomography (CT) data. For this purpose we exploit State of the Art rapid prototyping technologies such as 3D Printing and the Neurorobotics Platform for musculoskeletal simulations in virtual environments. The co-development integrates both advantages of virtual and physical experimental models and is expected to increase development speed of controllers that can be tested on the simulated counterpart before application to a printed robot model. We demonstrate the pipeline by generating a one year old infant model as a musculoskeletal simulation model and a print-in-place 3D printed skeleton as a single movable part. Even though we hereonly introduce the initial body generation and only a first testsetup for a modular sensory and control framework, we can clearly spot advantages in terms of rapid model generation and highly biological related models. Engineering costs are reducedand models can be provided to a wide research community for controller testing in an early development phase.
Aufgrund der steigenden Lebenserwartung und dem damit einhergehenden demographischen Wandel wird der Bedarf an Rehabilitations-Behandlungen in absehbarer Zukunft stark ansteigen. Ein Beispiel für diesen Trend ist die physiotherapeutische Behandlung nach Erhalt einer Knie-Totalendoprothese (Knie-TEP). So gehen Modellrechnungen basierend auf dem Bevölkerungswachstum und der bisherigen Prävalenz von Knie-TEPs davon aus, dass die Anzahl an durchgeführten Eingriffen in einkommensstarken Ländern wie Deutschland weiter zunehmen wird. Weiterhin stoßen traditionelle Rehabilitationsverfahren, gerade in strukturschwachen Regionen, schon heute an ihre Grenzen. Deutlich zu sehen war das während den Hochphasen der aktuellen Covid-19-Pandemie, als der Kontakt zwischen Therapeut*in und Patient*in flächendeckend eingeschränkt war. Eine erhöhte Nachfrage nach neuartigen Reha-Angeboten ist die logische Konsequenz. Innovative Konzepte sind daher dringend notwendig, um die daraus resultierenden technischen, sozialen und ökonomischen Herausforderungen zu bewältigen.
Work places and conditions strains the human body, both psychologically and biomechanically. In order to analyse working conditions and in the following to improve them, detailed knowledge about the effect of the different stressors on the body is needed. This manuscript discusses methods on how to evaluate biomechanical and mental loading and its effect on the musculoskeletal system. A possible workflow for the analysis is presented.
Repeated loadings may cause fatigue fractures in bony structures. Even if these failure types are known, data for trabecular bone exposed to cyclic loading are still insufficient as the majority of fatigue analyses on bone concentrate on cortical structures. Despite its highly anisotropic and inhomogeneous structure, trabecular bone is treated with continuum approaches in fatigue analyses. The underlying deformation and damage mechanism within trabecular specimens are not yet sufficiently investigated. In the present study different types of trabecular bone were loaded in monotonic and cyclic compression. In addition to the measurement of integral specimen deformations, optical deformation analysis was employed in order to obtain strain distributions at different scale levels, from the specimens' surface to the trabeculae level. These measurements allowed for the possibility of linking the macroscopic and microscopic mechanical behaviour of cancellous bone. Deformations were found to be highly inhomogeneous across the specimen. Furthermore strains were found to already localise at very low load levels and after few load cycles. Microcracks in individual trabeculae were induced in the very early stage of cyclic testing. The results provide evidence of the capability of the method to supply essential data on the failure behaviour of individual trabeculae in future studies.
The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions not aligned with the main physiological axis remains unclear. Furthermore age effects on the fatigue behaviour are not well described. In the present study, different groups of human vertebral cancellous bone were exposed to cyclic compression. The inital modulus and therefore lifetimes were found to be highly dependent on age. The decrease in both with increasing age was much more pronounced in specimens which were not aligned with the main physiological axis. This implies that old bone is much more sensitive to (cyclic) failure loads in general but particularly to loads which are not coincident with the physiological main axis.
The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions which are not aligned with the main physiological axis remains unclear. Furthermore site and species dependent relationships are not well described. In this study five different groups of trabecular bone, defined in terms of orientation, species and site were exposed to cyclic compression. In total, 108 fatigue tests were analysed. The lifetimes were found to decrease drastically when off-axis loads were applied. Additionally, species and site strongly affect fatigue lifetimes. Strains at failure were also found to be a function of orientation.
Für Mutter und Kind konnte das Risiko der Geburt durch die Weiterentwicklung der Medizin drastisch reduziert werden. Doch wie ist es um das Wohl derer bestellt, die die Gebärende unterstützen? Eine Studie der Ostbayerischen Technischen Hochschule Regensburg hat sich mit den muskuloskelettalen Beschwerden von Geburtshelfer:innen auseinandergesetzt
Autologous lipotransfer is a promising method for tissue regeneration, because white adipose tissue contains a heterogeneous cell population, including mesenchymal stem cells, endothelial cells, immune cells, and adipocytes. In order to improve the outcome, adipose tissue can be processed before application. In this study, we investigated changes caused by mechanical processing.
Lipoaspirates were processed using sedimentation, first-time centrifugation, shear-force homogenization, and second-time centrifugation. The average adipocyte size, stromal vascular cell count, and adipocyte depot size were examined histologically at every processing step. In addition, the adipose derived stem cells (ADSCs) were isolated and differentiated osteogenically and adipogenically. While homogenization causes a disruption of adipocyte depots, the shape of the remaining adipocytes is not changed. On average, these adipocytes are smaller than the depot adipocytes, they are surrounded by the ECM, and therefore mechanically more stable. The volume loss of adipocyte depots leads to a significant enrichment of stromal vascular cells such as ADSCs. However, the mechanical processing does not change the potential of the ADSCs to differentiate adipogenically or steogenically. It thus appears that mechanically processed lipoaspirates are promising for the reparation of even mechanically stressed tissue as that found in nasolabial folds. The changes resulting from the processing correspond more to a filtration of mechanically less stable components than to a manipulation of the tissue.
The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands.
A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis.
Fragestellung
Es soll in dieser Computersimulationsstudie untersucht werden, wie der Osteosyntheseverbund Platte mit Schrauben im Verbund mit einer im mittleren Drittel gebrochenen Clavicula durch das Bewegungsausmaß
in vivo belastet ist. Was sind die grundlegenden Kräfte die auf Clavicula und Implantat wirken und welchen Einfl uss hat die Bruchform.
Methodik
Die Muskel- und Gelenkkräfte sowie die Belastung des Implantatverbundes wurden mit einer muskuloskelletalen
Simulationssoftware (AnyBody Technology, V.4) berechnet. Hierfür wurden mit einem komplexen Model des menschlichen Körpers folgende Bewegungen analysiert: eine Flexion von 160° und Abduktion 160° mit
einem Gewicht von 2 kg in der Hand. Aus CT-Patientendaten wurden zwei dreidimensionale Modelle des Clavicula-Implantat Verbundes gebildet, die sich in der Frakturform unterscheiden (Querfraktur und vertikale
Fraktur). In beiden Modellen wurde eine Claviculaosteosynthese in superiorer Position mit einer 6 Loch LCP mit 2 Schrauben pro Hauptfragment verwendet. Die Materialeigenschaften wurden aus der Dichte des Materials sowie aus Literaturdaten verwendet. Die Muskel- und Gelenkkräfte aus der muskuloskelletalen Berechnung wurden auf das Finite Elemente Modell übertragen und die Spannungen und Dehnungen des Implantat-Knochenverbundes
wurden berechnet.
Ergebnisse
Es zeigte sich, dass die simulierte in vivo Belastung stark abhängig vom Flexionswinkel ist. Das Implantat ist in der superioren Lage auf Biegung belastet, welche maximale Werte im Überschulterniveau erreicht. Die Bruchform mit anatomischer Reposition und Kontakt der Hauptfragmente zueinander führt zu einer deutlichen Entlastung des Osteosyntheseverbundes im Vergleich zu einer Bruchform mit vertikaler Fraktur.
Schlussfolgerung
Aus den Analysen ist eine Positionierung der Plattenosteosynthese für die im mittleren Drittel frakturierte Clavicula in anterior-superiorer Lage wünschenswert. Die anatomische Reposition entlastet den Osteosyntheseverbund und sollte möglichst erreicht werden. Die Nachbehandlung sollte ein Bewegungsausmaß für den Arm für 4 Wochen für einfache Bruchformen auf 70° Flexion und Abduktion limitieren und für komplexe Bruchformen diese Limitierung ausgedehnt werden.
It is generally known that project-based learning is a very important part of engineering education to connect theoretical knowledge with practical work. Students learn to apply their knowledge to real-world challenges as it is the case in their later professional life. If students are not used to project work or the scientific topic is new and relatively complex, they may be overwhelmed. The consequence is that students achieve poor results, are frustrated, and therefore learning success is low. Semi-structured projects are introduced that combine the advantages of structured experiments with projects. The project work is structured into several parts with detailed descriptions of the tasks. In the end, students get similar results to doing a free project, but the success rate is higher due to higher guidance. Therefore, these semi-structured projects are seen to be an appropriate method to guide students to learn how to do project work. The feedback from most students is very positive. Some students with no previous lab experience complained about the project work and wished for more guidance to become familiar with lab work. In sum, the student feedback is encouraging to develop semi-structured projects further.
Pelvic floor dysfunction is a common problem in women and has a negative impact ontheir quality of life. The aim of this review was to provide a general overview of the current state oftechnology used to assess pelvic floor functionality. It also provides literature research of the phys-iological and anatomical factors that correlate with pelvic floor health. The systematic review wasconducted according to the PRISMA guidelines. PubMed, ScienceDirect, Cochrane Library andIEEE databases were searched for publications on sensor technology for the assessment of pelvicfloor functionality. Anatomical and physiological parameters were identified through a manualsearch. In the systematic review 115 publications were included. 12 different sensor technologieswere identified. Information on the obtained parameters, sensor position, test activities and subjectcharacteristics were prepared in tabular form from each publication. 16 anatomical and physiologi- cal parameters influencing pelvic floor health were identified in 17 published studies and rankedfor their statistical significance. Taken together, this review could serve as a basis for the develop-ment of novel sensors which could allow for quantifiable prevention and diagnosis, as well as par-ticularized documentation of rehabilitation processes related to pelvic floor dysfunctions.
Pelvic floor dysfunction is a common problem in women and has a negative impact on their quality of life. The aim of this review was to provide a general overview of the current state of technology used to assess pelvic floor functionality. It also provides literature research of the physiological and anatomical factors that correlate with pelvic floor health. This systematic review was conducted according to the PRISMA guidelines. The PubMed, ScienceDirect, Cochrane Library, and IEEE databases were searched for publications on sensor technology for the assessment of pelvic floor functionality. Anatomical and physiological parameters were identified through a manual search. In the systematic review, 114 publications were included. Twelve different sensor technologies were identified. Information on the obtained parameters, sensor position, test activities, and subject characteristics was prepared in tabular form from each publication. A total of 16 anatomical and physiological parameters influencing pelvic floor health were identified in 17 published studies and ranked for their statistical significance. Taken together, this review could serve as a basis for the development of novel sensors which could allow for quantifiable prevention and diagnosis, as well as particularized documentation of rehabilitation processes related to pelvic floor dysfunctions.
To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments.
INTRODUCTION
Several clinical studies demonstrated long-term adjacent-level effects after implantation of spinal fusion devices[1]. These effects have been reported as adjacent joint degeneration and the development of new symptoms correlating with adjacent segment degeneration[2] and the trend has therefore gone to motion preservation devices; however, these effects have not been understood very well and have not been investigated thoroughly[3].
The aim of this study is to investigate the effect of varying the stiffness of spinal fusion devices on the adjacent vertebral levels. Disc forces, moments and facet joint forces were analyzed.
METHODS
The AnyBody Modeling System was used to compute the in-vivo muscle and joint reaction forces of a musculoskeletal model. The full body model used in this study consists of 188 muscle fascicles in the lumbar spine and more than 1000 individual muscle branches in total. The model has been proposed by de Zee et al.[3], validated by Rasmussen et al.[4] and by Galibarov et al.[5]. The new model[5] determines the individual motions between vertebrae based on the equilibrium between forces acting on the vertebrae from muscles and joints and the passive stiffness in disks and ligaments, figure 1a. An adult of 1.75 m and 75 kg with a spinal implant in L4L5 was modeled. This model was subjected to a flexion-extension motion using different elastic moduli to analyze and compare to a non-implanted scenario. The analyzed variables were vertebral motion, the disc reaction forces and moments, as well as facet joint forces in the treated and the adjacent levels: L2L3, L3L4, L4L5 and L5-Sacrum.
RESULTS
When introducing a spinal fusion device in the L4L5 joint the reaction forces and moments decreased in this joint with stiffer devices leading to lower joint loads. However, in the adjacent joints, L3L4 and L5Sacrum, an increase was observed when implanting stiffer devices. Similar trends could be found for the L2L3 joint. The loads in the facet joints showed the same trends. While introducing a spinal fusion device reduced the facet joint forces in the treated joint, the loads in the adjacent facet joints were increased according to the stiffness of the implanted device, figure 1b.
DISCUSSION
While the treated disc joint showed reduced motion and loads, the adjacent levels demonstrated a significant increase. In particular, the increased facet joint forces in the adjacent levels can lead to adjacent level facet pain or accelerated facet joint degeneration. Introducing a device resulted in preventing facet contact and therefore facet joint loads, even using the device with the lowest stiffness.
CONCLUSION
The presented model shows that clinical complications such as facet joint degeneration in adjacent levels after implantation of spinal fusion device are consistent with the change in the mechanical-stimulus distribution in the system.
On modelling spine curvature dependent on muscular and external forces in multibody dynamics system
(2011)
This paper presents a computational approach for investigating effect of muscular and external forces on curvature of the lumbar spine. Multibody dynamics system is used to compute the lumbar spine curvature using a force-dependent kinematics facility, e.g. this method allows releasing some degrees of freedom in order to be computed based on the current load configuration.
Experimental and mathematical characterization of coronary polyamide-12 balloon catheter membranes
(2020)
The experimental quantification and modeling of the multiaxial mechanical response of polymer membranes of coronary balloon catheters have not yet been carried out. Due to the lack of insights, it is not shown whether isotropic material models can describe the material response of balloon catheter membranes expanded with nominal or higher, supra-nominal pressures. Therefore, for the first time, specimens of commercial polyamide-12 balloon catheters membranes were investigated during uniaxial and biaxial loading scenarios. Furthermore, the influence of kinematic effects on the material response was observed by comparing results from quasi-static and dynamic biaxial extension tests. Novel clamping techniques are described, which allow to test even tiny specimens taken from the balloon membranes. The results of this study reveal the semi-compliant, nonlinear, and viscoelastic character of polyamide-12 balloon catheter membranes. Above nominal pressure, the membranes show a pronounced anisotropic mechanical behavior with a stiffer response in the circumferential direction. The anisotropic feature intensifies with an increasing strain-rate. A modified polynomial model was applied to represent the realistic mechanical response of the balloon catheter membranes during dynamic biaxial extension tests. This study also includes a compact set of constitutive model parameters for the use of the proposed model in future finite element analyses to perform more accurate simulations of expanding balloon catheters.
Vascular damage develops with diverging severity during and after percutaneous coronary intervention with stent placement and is the prevailing stimulus for in-stent restenosis. Previous work has failed to link mechanical data obtained in a realistic in vivo or in vitro environment with data collected during imaging processes. We investigated whether specimens of porcine right coronary arteries soften when indented with a stent strut shaped structure, and if the softening results from damage mechanisms inside the fibrillar collagen structure. To simulate the multiaxial loading scenario of a stented coronary artery, we developed the testing device ‘LAESIO’ that can measure differences in the stress-stretch behavior of the arterial wall before and after the indentation of a strut-like stamp. The testing protocol was optimized according to preliminary experiments, more specifically equilibrium and relaxation tests. After chemical fixation of the specimens and subsequent tissue clearing, we performed three-dimensional surface and second-harmonic generation scans on the deformed specimens. We analyzed and correlated the mechanical response with structural parameters of high-affected tissue located next to the stamp indentation and low-affected tissue beyond the injured area. The results reveal that damage mechanisms, like tissue compression as well as softening, fiber dispersion, and the lesion extent, are direction-dependent, and the severity of them is linked to the strut orientation, indentation pressure, and position. The findings highlight the need for further investigations by applying the proposed methods to human coronary arteries. Additional data and insights might help to incorporate the observed damage mechanisms into material models for finite element analyses to perform more accurate simulations of stent-implantations.
Finite element (FE)–based studies of preoperative processes such as folding,pleating, and stent crimping with a comparison with experimental inflation tests are not yet available. Therefore, a novel workflow is presented in which residual stresses of balloon folding and pleating, as well as stent crimping, and the geometries of all contact partners were ultimately implemented in an FE code to simulate stent expansion by using an implicit solver. The numerical results demonstrate that the incorporation of residual stresses and strains experienced during the production step significantly increased the accuracy of the subsequent simulations, especially of the stent expansion model. During the preoperative processes, stresses inside the membrane and the stent material also reached a rather high level. Hence, there can be no presumption that balloon catheters or stents are undamaged before the actual surgery. The implementation of the realistic geometry, in particular the balloon tapers, and the blades of the process devices improved the simulation of the expansion mech-anisms, such as dogboning, concave bending, or overexpansion of stent cells. This study shows that implicit solvers are able to precisely simulate the mentioned preoperative processes and the stent expansion procedure without a preceding manipulation of the simulation time or physical mass.
We investigated the role of informative feedback on the neural correlates of perceptual learning in a coherent-motion detection paradigm. Stimulus displays consisted of four patches of moving dots briefly (500 ms) presented simultaneously, one patch in each visual quadrant. The coherence level was varied in the target patch from near threshold to high, while the other three patches contained only noise. The participants judged whether coherent motion was present or absent in the target patch. To guarantee central fixation, a secondary RSVP digit-detection task was performed at fixation. Over six training sessions subjects learned to detect coherent motion in a predefined quadrant (i.e., the learned location). Half of our subjects were randomly assigned to the feedback group, where they received informative feedback after each response during training, whereas the other group received non-informative feedback during training that a response button was pressed. We investigated whether the presence of informative feedback during training had an influence on the learning success and on the resulting BOLD response. Behavioral data of 24 subjects showed improved performance with increasing practice. Informative feedback promoted learning for motion displays with high coherence levels, whereas it had little effect on learning for displays with near-threshold coherence levels. Learning enhanced fMRI responses in early visual cortex and motion-sensitive area MT+ and these changes were most pronounced for high coherence levels. Activation in the insular and cingulate cortex was mainly influenced by coherence level and trained location. We conclude that feedback modulates behavioral performance and, to a lesser extent, brain activation in areas responsible for monitoring perceptual learning.
One of the fundamental challenges in L-PBF of filigree geometries, such as aortic stents used in biomedical applications, is the requirement for a robust yet easily removable support structure that allows each component to be successfully fabricated without distortion. To solve this challenge, an integrative experimental approach was attempted in the present study by identifying an optimal support structure design and an optimized support removal strategy for this design. The specimens were manufactured using four different support structure designs based on the geometry exposed to the laser beam during the L-PBF. Support removal procedures included sand blasting (SB), glass bead blasting (GB), and electrochemical polishing (ECP). The two best-performing designs (line and cross) were chosen due to shorter lead times and lower material consumption. As an additional factor that indicates a stable design, the breaking load requirement to remove the support structures was determined. A modified line support with a 145° included angle was shown to be the best support structure design in terms of breaking load, material consumption, and manufacturing time. All three procedures were used to ensure residue-free support removal for this modified line support design, with ECP proving to be the most effective.
Patients with juvenile retinal dystrophy often report that they are unaware of their central scotoma, suggesting the presence of perceptual filling-in. We used functional Magnetic Resonance Imaging (fMRI) to determine possible neural correlates of perceptual filling-in in patients with retinal distrophy and clinically established central scotoma in both eyes. The data of 5 patients (Stargardt disease, cone-rod dystrophy; mean age 45 yrs; scotoma diameter 10-20°) and of 5 normally sighted controls were analyzed. Fixation behaviour and perimetry were measured with a Nidek microperimeter. Magnetic resonance imaging was performed using a Siemens 3T Allegra scanner. We stimulated the central visual field (30 deg) with a vertically oriented, low spatial frequency (1 c/deg) high-contrast sinewave grating that was either a) continuous, or b) was interrupted by a central grey disk. The disk was either slightly larger than the scotoma (detectable on 75% of trials) or slightly smaller (detectable on 25% of trials). To control for attention, an eccentric fixation task was performed during scanning. Data were analyzed using SPM8 (GLM with ROI analysis to obtain percent signal change for foveal projection zone). Results: for all patients, the BOLD signal in the foveal projection area was significantly higher for the small disk (i.e., condition leading to complete filling-in) than for the large disk (i.e., no filling-in). This effect was absent in the control subjects. Our findings support the existence of an active neural process that leads to filling-in in patients with central visual field scotomata.
Hereditary and age-related forms of macular dystrophy (MD) are characterized by loss of cone function in the fovea, leading to central scotomata and eccentric fixation at the so-called preferred retinal locus (PRL). We investigated whether perceptual learning enhances visual abilities at the PRL. We also determined the neural correlates (3-Tesla fMRI) of learning success. Twelve MD patients (eight with age-related macular dystrophy, four with hereditary macular dystrophies) were trained on a texture discrimination task (TDT) over six days. Patients underwent three fMRI sessions (before, during and after training) while performing the TDT (target at PRL or opposite PRL). Reading speed, visual acuity (Vernier task) and contrast sensitivity were also assessed before and after training. With one exception, all patients showed improved performance (i.e. significant decrease in stimulus onset asynchronies and reaction times, significant increase in hit rates) on the TDT. Eight patients also showed moderate increases in reading speed, six patients showed improved thresholds in contrast sensitivity and nine patients showed improved thresholds in a vernier visual acuity task after TDT training. We found an increase in BOLD response in the projections zone of the PRL in the primary visual cortex in nine of twelve patients after training. The change in fMRI signal correlated (r = .8; p = .02) with the patients’ performance enhancements when the target was in the PRL. The results suggest that perceptual learning can enhance eccentric vision and cortical processing in MD patients.
Hereditary and age-related forms of macular dystrophy (MD) are characterized by loss of cone function in the fovea, leading to central scotomata and eccentric fixation at the so-called preferred retinal locus (PRL). We investigated whether perceptual learning enhances visual abilities at the PRL. We also determined the neural correlates (3-Tesla fMRI) of learning success. Twelve MD patients (eight with age-related macular dystrophy, four with hereditary macular dystrophies) were trained on a texture discrimination task (TDT) over six days. Patients underwent three fMRI sessions (before, during and after training) while performing the TDT (target at PRL or opposite PRL). Reading speed, visual acuity (Vernier task) and contrast sensitivity were also assessed before and after training. With one exception, all patients showed improved performance (i.e. significant decrease in stimulus onset asynchronies and reaction times, significant increase in hit rates) on the TDT. Eight patients also showed moderate increases in reading speed, six patients showed improved thresholds in contrast sensitivity and nine patients showed improved thresholds in a vernier visual acuity task after TDT training. We found an increase in BOLD response in the projections zone of the PRL in the primary visual cortex in nine of twelve patients after training. The change in fMRI signal correlated (r = .8; p = .02) with the patients’ performance enhancements when the target was in the PRL. The results suggest that perceptual learning can enhance eccentric vision and cortical processing in MD patients.
In recent years, musculoskeletal computation has become a widely used tool to investigate joint and muscle forces within the human body. However, the issue of muscle fatigue is not considered adequately in most models and is a challenging task. One aspect that needs to be examined is the interaction of muscles during an exhausting task. Therefore, an experimental study was designed to analyze the changes of back muscle recruitment pattern during such exercises.
In this study 38 subjects (27 male, 11 female, height = 177±8.5 cm, weight = 74.0±13.6 kg) participated. Each subject had to perform three static and three dynamic exhausting exercises where the back muscles were loaded with subject specific forces using a dynamometer adapter especially designed for the trunk muscles. To collect the muscle activity, twelve surface electromyography sensors were applied on the back, and four on the abdominal muscles. Muscle activity and fatigue were analyzed by calculating the maximum voluntary contraction normalized signal and the median frequency. At first the fatigue of m. erector spinae and m. multifidi was analyzed, since these muscles carry the main load during the exercises. Subsequently the activity of the m. trapezius, m. rectus abdominis and m. obliquus externus were investigated to determine recruitment patterns. To gain more detailed information of these patterns a numerical model was built using the AnyBody Modeling System™. Analyzing the measurements, we can observe an increasing muscle activity during isokinetic exercises while the force is constant. Since the activity in the simulation is defined as the current force output divided by the strength of the muscle, the strength parameter was scaled down based on the measured data, assuming a linear force – activity correlation, and using a numerical algorithm considering the influence of cross talk.
The results show, that changes in recruitment pattern can be divided into three major subgroups. Prior to total exhaustion, some of the subjects show additional activation of muscles in the trapezius region, while other subjects show an additional activation of abdominal muscles, increasing the intra-abdominal pressure which supports the spine. In the third group an activation in both regions can be observed.
The numerical simulations show an increasing activity of abdominal muscles as well as muscles in the upper back. Especially the m. latissimus dorsi shows a significantly higher activity.
The results lead to the conclusion that prior to total exhaustion, additional muscles are recruited to support the main muscles. It was shown that abdominal muscles are activated to support back muscles by pressurizing the trunk cavity to delay total exhaustion as long as possible. In conclusion, the results show that changes in muscle recruitment pattern need to be considered when introducing muscle fatigue to musculoskeletal models.
Aims
Drug-eluting stents (DES) represent a major advance in interventional cardiology. Along with the success shown, current DES also present limitations related to the presence of polymer-coating, fixed drug, and dose used. With the ISAR (Individualized Drug-Eluting Stent System to Abrogate Restenosis) project, a DES system has been developed that permits individualized choice of the drug and dose to use for the given patient. The objective of this prospective dose finding study was to assess the feasibility, safety, and efficacy of a polymer-free on-site stent coating with increasing rapamycin doses.
Methods and results
In this dose finding study, 602 patients were sequentially enrolled in four groups: microporous bare metal stent (BMS), DES stents coated with a 0.5, 1.0, and 2.0% rapamycin solution. The angiographic in-segment restenosis rate at follow-up angiography was the primary study endpoint. In-segment restenosis was significantly reduced from 25.9% with BMS to 18.9, 17.2, and 14.7% with 0.5, 1.0, and 2.0% rapamycin-eluting stents, respectively (P=0.024). Similarly, the need for target lesion revascularization at 1 year follow-up was reduced from 21.5% with BMS to 16.4, 12.6, and 8.8% with 0.5, 1.0, and 2.0% rapamycin-eluting stents, respectively (P=0.006).
Conclusion
The placement of polymer-free stents coated on-site with rapamycin is feasible and safe. Furthermore, a dose-dependent efficacy in restenosis prevention is achievable with this new DES concept.
BACKGROUND: Autologous fat grafting (AFG) has been established over the past two decades as an additive technique during and after breast reconstruction. Complete reconstruction of the breast mound with AFG alone represents an exceptional technique that has been published mostly in case reports or in studies with limited cases.The purpose of this study is to investigate the influence of three different techniques for breast reconstruction on the recovery of skin sensitivity at the reconstructed breast.
METHODS: The study included 30 patients after mastectomy following breast cancer. Three groups were examined: A) breast reconstruction by autologous fat grafting (AFG), B) breast reconstruction by deep inferior epigastric artery perforator flap (DIEP) and C) breast reconstruction by expander/implant (TE).Biometric data were compared; sensitivity tests were performed using Semmes-Weinstein monofilaments.The non-operated, healthy contralateral breasts of the patients were used as a reference.
RESULTS: While the traditional reconstruction techniques by microsurgical anastomosed perforator flap or expander/implant showed a strongly decreased or completely missing sensitivity of the skin, the tests after reconstruction by AFG represented high values of sensory recovery, which came close to the reference group of non-operated breasts.
CONCLUSION: To our knowledge, this is the first study to compare skin sensitivity after AFG-based reconstruction to established techniques for breast reconstruction. We could demonstrate in a limited group of patients, that breast reconstruction by autologous fat grafting can achieve higher values of skin sensitivity compared to traditional techniques.
Purpose
Lipofilling has been established as a standard technique for contour enhancement following breast reconstruction. However, there is a paucity in current literature regarding the use of this technique for complete reconstruction of the female breast as an alternative to conventional techniques, such as expander or flap-based procedures. In particular, the influence of pre-operative irradiation for successful reconstruction has rarely been examined in published studies. Here, the authors describe their experience with successful fat injection in pre-radiated breasts in comparison with non-pre-radiated patients.
Methods
In this retrospective study, we examined a total of 95 lipofilling treatments on 26 patients (28 breasts). All of them experienced mastectomy following breast cancer; local breast defects after partial resection of the gland were not included in this study. In total, 47 lipofilling procedures in 12 non-irradiated patients (14 breasts) and 48 procedures in 14 irradiated women (also 14 breasts) were performed. Per session, approximately 297 +/- 112 cc of adipose tissue was grafted in group A (no radiotherapy) and approximately 259 +/- 93 cc was grafted in group B (radiotherapy).
Results
Among the group of women without pre-operative radiation, 71% of breast reconstructions limited to lipofilling only showed constant engraftment of fat tissue with a successful reconstructive result, whereas only 21% of the patients with pre-radiated breasts showed complete reconstruction of the breast with a permanent fat in-growth.
Conclusion
Preoperative radiotherapy significantly impedes successful completion of breast reconstructions planned only by autologous fat transfer. Patients should be selected individually and carefully for complete breast reconstruction using lipofilling only.
Objectives: The mechanical properties and seeding with endothelial cells were investigated in fresh and cryopreserved human umbilical vein.
Methods: Human umbilical veins (HUV) were frozen in Euro-Collins/1M DMSO at –1°C/min and stored in liquid nitrogen. Stress-strain relationships of fresh and thawed veins were determined in an uniaxial tension-testing rig. HUV endothelial cells (HUVEC) were seeded onto denuded HUV under static conditions and grown for 3d. Luminal surfaces were analyzed by scanning electron microscopy. Calcein-stained cells were seeded hyperconfluently to determine the cell retention capacity of fresh and cryopreserved veins.
Results: The stress-strain relationships of HUV followed a biphasic pattern typical for natural vessels. Neither the failure stress (2.71±0.36 vs. 3.25±0.97 N, n=3) nor the displacement required to achieve failure (9.73±0.9 vs. 7.43±2.07mm, n=3) were altered by cryopreservation. The burst pressure was estimated as approx. 1000mm Hg within the limitations of the uniaxial model. HUVEC seeded onto denuded HUV formed patches (at 9E3 cells per cm2) or an almost confluent endothelium (at 3E4 cells per cm2) within three days. The capacity to retain seeded HUVEC of denuded HUV was not altered by cryopreservation (1.15±0.08E5 vs. 1.26±0.14E5 cells per cm2, n=6).
Conclusions: The burst pressure of HUV seems to be sufficiently high for the human arterial circulation and is not altered by cryopreservation. HUVEC can establish a confluent endothelium on denuded HUV. Therefore HUV appears to be a suitable storable scaffold for vascular tissue engineering.
Tissue-engineered vessel grafts have to mimic the biomechanical properties of native blood vessels. Manufacturing processes often condition grafts to adapt them to the target flow conditions. Graft stiffness is influenced by material properties and dimensions and determines graft compliance. This proof-of-concept study evaluated a contact-free method to monitor biomechanical properties without compromising sterility. Forced vibration response analysis was performed on human umbilical vein (HUV) segments mounted in a buffer-filled tubing system. A linear motor and a dynamic signal analyser were used to excite the fluid by white noise (0-200 Hz). Vein responses were read out by laser triangulation and analysed by fast Fourier transformation. Modal analysis was performed by monitoring multiple positions of the vessel surface. As an inverse model of graft stiffening during conditioning, HUV were digested proteolytically, and the course of natural frequencies (NFs) was monitored over 120 min. Human umbilical vein showed up to five modes with NFs in the range of 5-100 Hz. The first natural frequencies of HUV did not alter over time while incubated in buffer (p = 0.555), whereas both collagenase (-35%, p = 0.0061) and elastase (-45%, p < 0.001) treatments caused significant decreases of NF within 120 min. Decellularized HUV showed similar results, indicating that changes of the extracellular matrix were responsible for the observed shift in NF. Performing vibration response analysis on vessel grafts is feasible without compromising sterility or integrity of the samples. This technique allows direct measurement of stiffness as an important biomechanical property, obviating the need to monitor surrogate parameters. Copyright (C) 2016 John Wiley & Sons, Ltd.
Bioresorbable materials are under investigation due to their promising properties for applications as implant material. This study is about the degradation and bioactivity behaviour of magnesium foils, which allegorize dental membranes. The degradation behaviour including pitting corrosion during immersion tests can be precisely observed using micro-computed tomography. Using the bioactivity test according to Kokubo, it is shown that magnesium has strong Ca-phosphate layer formation correlated with high degradation. Therefore, magnesium foils appear to hold a great potential for bone implant application.
One of the main goals in reconstructing rotator cuff tears is the restoration of glenohumeral joint stability, which is subsequently of utmost importance in order to prevent degenerative damage such as superior labral anterior posterior (SLAP) lesion, arthrosis, and malfunction. The goal of the current study was to facilitate musculoskeletal models in order to estimate glenohumeral instability introduced by muscle weakness due to cuff lesions. Inverse dynamics simulations were used to compute joint reaction forces for several static abduction tasks with different muscle weakness. Results were compared with the existing literature in order to ensure the model validity. Further arm positions taken from activities of daily living, requiring the rotator cuff muscles were modeled and their contribution to joint kinetics computed. Weakness of the superior rotator cuff muscles (supraspinatus; infraspinatus) leads to a deviation of the joint reaction force to the cranial dorsal rim of the glenoid. Massive rotator cuff defects showed higher potential for glenohumeral instability in contrast to single muscle ruptures. The teres minor muscle seems to substitute lost joint torque during several simulated muscle tears to maintain joint stability. Joint instability increases with cuff tear size. Weakness of the upper part of the rotator cuff leads to a joint reaction force closer to the upper glenoid rim. This indicates the comorbidity of cuff tears with SLAP lesions. The teres minor is crucial for maintaining joint stability in case of massive cuff defects and should be uprated in clinical decision-making.
Thoracolumbar spine model with articulated ribcage for the prediction of dynamic spinal loading
(2016)
Musculoskeletal modeling offers an invaluable insight into the spine biomechanics. A better understanding of thoracic spine kinetics is essential for understanding disease processes and developing new prevention and treatment methods. Current models of the thoracic region are not designed for segmental load estimation, or do not include the complex construct of the ribcage, despite its potentially important role in load transmission. In this paper, we describe a numerical musculoskeletal model of the thoracolumbar spine with articulated ribcage, modeled as a system of individual vertebral segments, elastic elements and thoracic muscles, based on a previously established lumbar spine model and data from the literature. The inverse dynamics simulations of the model allow the prediction of spinal loading as well as costal joints kinetics and kinematics. The intradiscal pressure predicted by the model correlated well (R2=0.89) with reported intradiscal pressure measurements, providing a first validation of the model. The inclusion of the ribcage did not affect segmental force predictions when the thoracic spine did not perform motion. During thoracic motion tasks, the ribcage had an important influence on the predicted compressive forces and muscle activation patterns. The compressive forces were reduced by up to 32%, or distributed more evenly between thoracic vertebrae, when compared to the predictions of the model without ribcage, for mild thoracic flexion and hyperextension tasks, respectively. The presented musculoskeletal model provides a tool for investigating thoracic spine loading and load sharing between vertebral column and ribcage during dynamic activities. Further validation for specific applications is still necessary.
Thoracolumbar spine model with articulated rigcage for the prediction of dynamic spinal loading
(2015)
BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough.
Common Schanz screw systems can be used to stabilize pelvic ring fractures. In order to accommodate for different patient’s requirements, implants can be placed in cranio-caudal direction into the os ilium (T1), or into the supraacetabular bone canal, and thus, in dorso-ventral direction (T2). Whereas both techniques are currently used, no data of the biomechanical behavior is available up to this date. The aim of this study is to analyze, whether T2 shows biomechanical advantages with respect to tissue and implant stresses due to the enlarged bone-implant interface. Forces acting on the pelvis were analyzed using motion capture data of a gait cycle obtained by the utilization of a musculoskeletal simulation program. A three dimensional finite element (FE) model of the pelvis with grayscale-based material properties was generated. The muscle and joint reaction forces at toe-off were applied to the FE model and instable pelvis fractures were implemented. The osteosynthesis systems were positioned within the model in order to enable the comparison between the two different surgical techniques. Stresses and displacements were analyzed for bone tissue, fracture zone and implant.
T2 lead to approx. 30% larger displacements in the fracture zone. Von-Mises stresses were larger for T2 in the implant (80 MPa vs. 227 MPa), whereas T1 leads to larger stresses in the bone tissue (200 MPa vs. 140 MPa).
Both implantation techniques showed a good biomechanical behavior. Differences could be found with respect to tissue strains and deformations in the fracture zone. If bone quality or fracture healing are of concern, T2 or T1 should be used, respectively. However, both techniques seem to be applicable for cases with no special requirements. Further analyses aim to investigate the behavior under cyclic loading.
Results of WICOVIR Gargle Pool PCR Testing in German Schools Based on the First 100,000 Tests
(2021)
Background:
Opening schools and keeping children safe from SARS-CoV-2 infections at the same time is urgently needed to protect children from direct and indirect consequences of the COVID-19 pandemic. To achieve this goal, a safe, efficient, and cost-effective SARS-CoV-2 testing system for schools in addition to standard hygiene measures is necessary.
Methods:
We implemented the screening WICOVIR concept for schools in the southeast of Germany, which is based on gargling at home, pooling of samples in schools, and assessment of SARS-CoV-2 by pool rRT-PCR, performed decentralized in numerous participating laboratories. Depooling was performed if pools were positive, and results were transmitted with software specifically developed for the project within a day. Here, we report the results after the first 13 weeks in the project.
Findings:
We developed and implemented the proof-of-concept test system within a pilot phase of 7 weeks based on almost 17,000 participants. After 6 weeks in the main phase of the project, we performed >100,000 tests in total, analyzed in 7,896 pools, identifying 19 cases in >100 participating schools. On average, positive children showed an individual CT value of 31 when identified in the pools. Up to 30 samples were pooled (mean 13) in general, based on school classes and attached school staff. All three participating laboratories detected positive samples reliably with their previously established rRT-PCR standard protocols. When self-administered antigen tests were performed concomitantly in positive cases, only one of these eight tests was positive, and when antigen tests performed after positive pool rRT-PCR results were already known were included, 3 out of 11 truly positive tests were also identified by antigen testing. After 3 weeks of repetitive WICOVIR testing twice weekly, the detection rate of positive children in that cohort decreased significantly from 0.042 to 0.012 (p = 0.008).
Interpretation:
Repeated gargle pool rRT-PCR testing can be implemented quickly in schools. It is an effective, valid, and well-received test system for schools, superior to antigen tests in sensitivity, acceptance, and costs.
Einleitung:
Blutdruck gilt als sogenannter Vitalparameter als einer der grundlegenden Indikatoren für den Gesundheitszustand einer Person. Sowohl zu niedriger als auch zu hoher Blutdruck kann lebensbedrohend sein, letzerer ist darüber hinaus ein Risikofaktor insbesondere für Herz-Kreislauferkrankungen, die trotz wichtiger Fortschritte in der Behandlung immer noch die häufigste Todesursache in Deutschland darstellen. Die Hämodynamik, also die raumzeitliche Dynamik des Blutflusses, und der Gefäßzustand sind eng verbunden mit dem Blutdruck und ebenfalls von hoher klinischer Relevanz, u.a. zur Identifikation von Durchblutungsstörungen und ungünstigen Druckverteilungen der Gefäßwand. Innovationen in der Messtechnik als auch in der Datenanalyse bieten heute neue Möglichkeiten der Erfassung und Bewertung von Blutdruck, Hämodynamik und Gefäßzustand [1], [2], [3], [4].
Methodik:
In einer gemeinsamen Workshopserie der AG Medizinische Bild- und Signalverarbeitung der GMDS und des Fachausschusses Biosignale der DGBMT werden wir neue Ansätze und Lösungen für Mess- und Analyseverfahren zu Blutdruck und -fluss sowie zum Gefäßzustand vorstellen und diskutieren. Dabei stehen im ersten Workshop auf der GMDS Jahrestagung Bildbasierte Verfahren im Zentrum, während der zweite Workshop auf der DGBMT Jahrestagung den Fokus auf Biosignalbasierten Verfahren legt. Es werden aktuelle Forschungsergebnisse vorgestellt und diskutiert. Es sind jeweils mehrere Vorträge geplant mit ausreichend Zeit zur Diskussion. Folgende Vorträge sind geplant (Arbeitstitel):
Sebastian Zaunseder: Videobasierte Erfassung des Blutdrucks
Anja Hennemuth: A Visualization Toolkit for the Analysis of Aortic Anatomy and Pressure Distribution
Lars Krenkel: Numerische Analyse der Rupturwahrscheinlichkeit zerebraler Aneurysmata
Susanne Schnell: Messung des Blutflusses und hämodynamischer Parameter mit 4D flow MRI: Möglichkeiten und Herausforderungen
Ergebnisse:
Ziel des Workshops ist die Identifikation von innovativen Ansätzen und neuen Methoden zur qualitativen und quantitativen Bestimmung von hämodynamischen Parametern sowie deren kritische Bewertung durch die Community für die Eignung in der klinischen Entscheidungsunterstützung.
Diskussion:
Der Workshop leistet inhaltlich einen Beitrag zu zentralen Aspekten für die Herz-Kreislauf-Medizin. Er bringt dabei Expertise aus verschiedenen Bereichen zusammen und schlägt die Brücke zwischen Kardiologie, Medizininformatik und Medizintechnik.
Schlussfolgerung:
Innovative Technologien aus Medizintechnik und Informatik ermöglichen zunehmend einfache und raumzeitlich aufgelöste Erfassung und Bewertung wichtiger Informationen zur Unterstützung von Diagnose und Therapieverfolgung.
[1] Zaunseder S, Trumpp A, Wedekind D, Malberg H. Cardiovascular assessment by imaging photoplethysmography - a review. Biomed Tech (Berl). 2018 Oct 25;63(5):617–34.
[2] Huellebrand M, Messroghli D, Tautz L, Kuehne T, Hennemuth A. An extensible software platform for interdisciplinary cardiovascular imaging research. Comput Methods Programs Biomed. 2020 Feb;184:105277.
[3] Schmitter S, Adriany G, Waks M, Moeller S, Aristova M, Vali A, et al. Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T. Magn Reson Med. 2020 Oct;84(4):1947–60.
[4] Birkenmaier C, and Krenkel, L. Flow in Artificial Lungs. In: New Results in Numerical and Experimental Fluid Mechanics XIII. Contributions to the 22nd STAB/DGLR Symposium. Springer; 2021.
Air leakage past High-Volume-Low-Pressure (HVLP) endotracheal tube (ETT) cuffs creates a potential infection risk for health care professionals during ventilation of patients suffering from contagious airborne diseases. However, unlike silent aspiration, a phenomenon where fluids enter the airways of intubated patients, the aspect of aerosol emergence through cuff folds -what we called accordingly “silent breathing” (SB)- has not been investigated in detail so far.
This study investigates air leakage past HVLP cuffs with varying cuff pressures under realistic artificial breathing scenarios experimentally and in addition numerically. The focus was laid on the parametric investigation of the occurrence and furthermore on different influencing factors of silent breathing. The morphology of the folds responsible for the leakage was captured using high-resolution 3D microcomputed tomography (μCT). For the numerical investigations (Com-putational Fluid Dynamics - CFD), the commercial CFD Software package FLUENT 2021 R2 (ANSYS, Inc., Canonsburg, PA, US), as well as the DLR in-house research code THETA has been used.
Computational Fluid Dynamics (CFD) and experimental investigations on a generic model of the trachea have been carried out focusing on the impact of an endotracheal tube (ETT) on the resulting flow regime. It could be shown that detailed modelling of the airway management devices is essential for proper flow prediction, but secondary details as Murphy Eyes can be neglected. Models with bending and connector promote the formation of stronger secondary flows and disturbances which persist for a longer time.
Accurate and reliable information about three-dimensional (3D) knee joint laxity can prevent misdiagnosis and avoid incorrect treatments. Nevertheless, knee laxity assessments presented in the literature suffer from significant drawbacks such as soft tissue artifacts, restricting the knee within the measurement, and the absence of quantitative knee ligament property information. In this study, we demonstrated the applicability of a novel methodology for measuring 3D knee laxity, combining robotics- and image-based technology. As such technology has never been applied to healthy living subjects, the aims of this study were to develop novel technology to measure 3D knee laxity in vivo and to provide proof-of-concept 3D knee laxity measurements. To measure tibiofemoral movements, four healthy subjects were placed on a custom-built arthrometer located inside a low dose biplanar X-ray system with an approximately 60 deg knee flexion angle. Anteroposterior and mediolateral translation as well as internal and external rotation loads were subsequently applied to the unconstrained leg, which was placed inside a pneumatic cast boot. Bone contours were segmented in the obtained X-rays, to which subject-specific bone geometries from magnetic resonance imaging (MRI) scans were registered. Afterward, tibiofemoral poses were computed. Measurements of primary and secondary laxity revealed considerable interpersonal differences. The method differs from those available by the ability to accurately track secondary laxity of the unrestricted knee and to apply coupled forces in multiple planes. Our methodology can provide reliable information for academic knee ligament research as well as for clinical diagnostics in the future.
In Vitro Analysis of Human Cartilage Infiltrated by Hydrogels and Hydrogel-Encapsulated Chondrocytes
(2023)
Osteoarthritis (OA) is a degenerative joint disease causing loss of articular cartilage and structural damage in all joint tissues. Given the limited regenerative capacity of articular cartilage, methods to support the native structural properties of articular cartilage are highly anticipated. The aim of this study was to infiltrate zwitterionic monomer solutions into human OA-cartilage explants to replace lost proteoglycans. The study included polymerization and deposition of methacryloyloxyethyl-phosphorylcholine- and a novel sulfobetaine-methacrylate-based monomer solution within ex vivo human OA-cartilage explants and the encapsulation of isolated chondrocytes within hydrogels and the corresponding effects on chondrocyte viability. The results demonstrated that zwitterionic cartilage–hydrogel networks are formed by infiltration. In general, cytotoxic effects of the monomer solutions were observed, as was a time-dependent infiltration behavior into the tissue accompanied by increasing cell death and penetration depth. The successful deposition of zwitterionic hydrogels within OA cartilage identifies the infiltration method as a potential future therapeutic option for the repair/replacement of OA-cartilage extracellular suprastructure. Due to the toxic effects of the monomer solutions, the focus should be on sealing the OA-cartilage surface, instead of complete infiltration. An alternative treatment option for focal cartilage defects could be the usage of monomer solutions, especially the novel generated sulfobetaine-methacrylate-based monomer solution, as bionic for cell-based 3D bioprintable hydrogels.
In the structure of musculoskeletal injuries, calcaneal fractures account for up to 4 % of all skeletal fractures and up to 60 % of hindfoot fractures. The effect of the displacement of the peripheral fragment of the calcaneus on the calf muscles’s reaction forces at the time of the adoption of the simplified squatting position was investigated by modeling in AnyBody Modeling System 6.0 software. M.gastrocnemius (lateralis et medialis) in the initial phase of motion in all variants of the peripheral fragment displacement did not develop sufficient muscular effort in comparison to the intact calcaneus. M.soleus medialis et lateralis showed significant increase in muscle activity rates in the initial phase of motion (41.87 ± 1.90 H and 52.07 ± 2.10 H) before reaching its maximum values, as compared with those of the intact calcaneus. In the final phase of the movement, upon muscle reaches its maximum length, muscular strength indicators of the m.soleus returned to their original values or were significantly below them. The decline in muscle strength was due to shortening of the moment arm or muscle excursion in case of convergence of muscle attachment points. When the peripheral fragment is displaced, due to putting down the heel to the surface of the support in terms of anatomical muscle lengthening, it takes extra effort to achieve rest length and its maximum power. In all types of the displacement of the peripheral fragment, the function of three-headed calf muscle is disturbed with involvement of additional muscular effort and energy expenditure. This fact should motivate the surgeon on the need for accurate repositioning of bone fragments in calcaneal fractures with the displacement of the peripheral fragment.
Effect of the fractured calcaneus's peripheral fragment displacement on the triceps surae function
(2015)
The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of normal gait. To evaluate the testing system, 12 femora pairs were tested under 25,000 cycles with two standard osteosyntheses (Proximal Femoral Nail Antirotation/Gamma3 Nail). For angular movement, the varus collapse to cut out (∝CO) (∝CO=4.8°±2.1° for blade and ∝CO=7.8°±3.8° for screw) was the dominant failure mode, and only slight rotational angle shifts (∝Rot) (∝Rot=1.7°±0.4° for blade and ∝Rot=2.4°±0.3° for screw) of the femoral head around the implant axis were observed. Angular displacements in varus direction and rotation were higher in specimens reinforced with screws. Hence, the cut out model and the migration directions showed a distinction between helical blade and hip screw. However, there were no significant differences between the different implants. The new setup is able to create clinical failures and allows to give evidence about the anchorage stability of different implant types under dynamic gait motion pattern.
Ein interdisziplinäres Forschungsprojekt der Ostbayerischen Hochschule Regensburg untersucht, inwiefern Telemedizin und digitale Anwendungen die Therapie und Pflege von Menschen mit Schlaganfall in ihrem häuslichen Umfeld unterstützen, ihre Lebensqualität beeinflussen und die intersektorale Versorgung verbessern kann.
BACKGROUND: Thrombosis remains a critical complication during venovenous extracorporeal membrane oxygenation (VV ECMO). The involvement of neutrophil extracellular traps (NETs) in thrombogenesis has to be discussed. The aim was to verify NETs in the form of cell-free DNA (cfDNA) in the plasma of patients during ECMO.
METHODS: A fluorescent DNA-binding dye (QuantifFluor®, Promega) was used to detect cell-free DNA in plasma samples. cfDNA concentrations from volunteers (n = 21) and patients (n = 9) were compared and correlated with clinical/technical data before/during support, ECMO end and time of a system exchange.
RESULTS: Before ECMO, patients with a median (IQR) age of 59 (51/63) years, SOFA score of 11 (10/15), and ECMO run time of 9.0 (7.0/19.5) days presented significantly higher levels of cfDNA compared to volunteers (6.4 (5.8/7.9) ng/μL vs. 5.9 (5.4/6.3) ng/μL; p = 0.044). Within 2 days after ECMO start, cfDNA, inflammatory, and hemolysis parameters remained unchanged, while platelets decreased (p = 0.005). After ECMO removal at the end of therapy, cfDNA, inflammation, and coagulation data (except antithrombin III) remained unchanged. The renewal of a system resulted in known alterations in fibrinogen, d-dimers, and platelets, while cfDNA remained unchanged.
CONCLUSION: Detection of cfDNA in plasma of ECMO patients was not an indicator of acute and circuit-induced thrombogenesis.
"Topographic Shift": a new digital approach to evaluating topographic changes of the female breast
(2021)
Purpose
To assess precise topographic changes of the breast, objective documentation and evaluation of pre- and postoperative results are crucial. New technologies for mapping the body using digital, three-dimensional surface measurements have offered novel ways to numerically assess the female breast. Due to the lack of clear demarcation points of the breast contour, the selection of landmarks on the breast is highly dependent on the examiner, and, therefore, is prone to error when conducting before-after comparisons of the same breast. This study describes an alternative to volumetric measurements, focusing on topographic changes of the female breast, based on three-dimensional scans.
Method
The study was designed as an interventional prospective study of 10 female volunteers who had planned on having aesthetic breast augmentation with anatomical, textured implants. Three dimensional scans of the breasts were performed intraoperatively, first without and then with breast implants. The topographic change was determined as the mean distance between two three-dimensional layers before and after augmentation. This mean distance is defined as the Topographic Shift. Results The mean implant volume was 283 cc (SD = 68.6 cc, range = 210-395 cc). The mean Topographic Shift was 7.4 mm (SD = 1.9 mm, range = 4.8-10.7 mm). The mean Topographic Shifts per quadrant were: I: 8.0 mm (SD = 3.3 mm); II: 9.2 mm (SD = 3.1 mm); III: 6.9 mm (SD = 3.5 mm); IV: 1.9 mm (SD = 4.3 mm).
Conclusion
The Topographic Shift, describing the mean distance between two three-dimensional layers (for example before and after a volume changing therapy), is a new approach that can be used for assessing topographic changes of a body area. It was found that anatomical, textured breast implants cause a topographic change, particularly on the upper breast, in quadrant II, the decollete.
A proposal for the classification of dental alloys according to their resistance to corrosion
(2007)
Objectives
The purpose of this study was to establish a method to compare and classify dental alloys in relation to their resistance to corrosion.
Methods
Alloy samples and pure metal samples were prepared and tested in chemical and electrochemical corrosion according to ISO 10271. For electrochemical test, the rest potential versus time and a potentiodynamic scan were recorded. After chemical corrosion test, the ions released were analyzed by ICP (induced coupled plasma) spectroscopy.
Results
High gold alloys had a similar polarization curve than gold. The same effect was observed for Pd–base alloys, their curves were similar to the one of palladium. The ions released during chemical corrosion were non-precious metallic ions. Thereby Ni–Cr alloys were found to release the most ions. Au–Pt alloys showed the highest release of ions compared with other precious alloys but low compared with Ni–Cr. Electrochemical corrosion was more aggressive than chemical corrosion and every type of elements was etched, the higher the precious metal content, the higher the resistance to corrosion of the alloy.
Discussion
Using the recorded data, a classification system for electrochemical corrosion was developed and discussed to judge the results. Hereby were gold and zinc used as reference materials. The applied classification system defines five classes and it is proposed that alloys of class V are not acceptable. For chemical corrosion resistance, three classes were distinguished according to the quantity of metallic ions released and it is proposed that class III (100–1000 μg/cm2 week) is not acceptable. Palladium and Pd–base alloys showed a higher electrochemical and chemical corrosion resistance than gold.
The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands.
Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity.
Musculoskeletal lower back load of accoucheurs during childbirth – A pilot and feasibility study
(2021)
Introduction: Back problems represent one of the leading causes of accouchers' work-related musculoskeletal morbidities. The correct execution of birth-related maneuvers including manual perineal protection is crucial not only for the mother and child but also for obstetricians and midwives to reduce any strain on their musculoskeletal system. Therefore, the overall aim of this study was to test the feasibility of determining the effect of different accouchers' postures (standing and kneeling) on their musculoskeletal system.
Methods: The biomechanical analysis is based on musculoskeletal simulations that included motion recordings of real deliveries as well as deliveries conducted on a birthing simulator. These simulations were then used to determine individual joints' loads.
Results: In the kneeling posture, both a low intra-operator variability and a lower average maximum load of the lower back was observed. For the standing position the spine load was reduced by pivoting the elbow on the accouchers' thigh, which in turn was associated with a significantly greater load on the shoulder joint.
Conclusion: The study demonstrated the feasibility of our technique to assess joints loads. It also provided initial data indicating that a posture that reduces spinal flexion and tilt, achieved in this study by the kneeling, can significantly reduce the strain on the practitioner's musculoskeletal system.
With the progress in modern medicine, it was possible to significantly reduce the risks of birth for mother and child. One aspect that has received less attention so far is the risk of injury to the accoucheurs (obstetricians and midwives) during the birth process. Indeed, studies indicate that 92% of midwives suffer from musculoskeletal disorders, with the lower back being the main cause of complaints (72%). The aim of this study was to investigate two commonly used postural techniques used by accoucheurs during childbirth and to analyze the resulting load on the lower back using the AnyBodyTM musculoskeletal simulation software.
Elbow stability is derived from a combination of muscular, ligamentous, and bony structures. After an elbow trauma the stability of the joint is an important decision criterion for the subsequent treatment. The decision regarding non-operative/operative care depends mostly on subjective assessments of medical experts. Therefore, the aim of this study is to use musculoskeletal simulations as an objective assessment tool to investigate the extent to which failure of different stabilizers affects the elbow stability and how these observations correspond to the assessment from clinical practice. A musculoskeletal elbow simulation model was developed for this aim. To investigate the stability of the elbow, varus/valgus moments were applied under 0°, 45°and 90° flexion while the respective cubital angle was analyzed. This was performed for nine different injury scenarios, which were also evaluated for stability by clinical experts. With the results, it can be determined by which injury pattern and under which flexion angle the elbow stability is impaired regarding varus/valgus moments. The scenario with a complete failure of the medial and lateral ligaments and a fracture of the radial head was identified as having the greatest instability. The study presented a numerical determination of elbow stability against varus/valgus moments regarding clinical injury patterns, as well as a comparison of the numerical outcome with experience gained in clinical practice. The numerical predictions agree well with the assessments of the clinical specialists. Thus, the results from musculoskeletal simulation can make an important contribution to a more objective assessment of the elbow stability.
Outputs of musculoskeletal models should be considered probabilistic rather than deterministic as they are affected by inaccuracies and estimations associated with the development of the model. One of these uncertainties being critical for modeling arises from the determination of the muscles' line of action and the physiological cross-sectional area. Therefore, the aim of this study was to evaluate the outcome sensitivity of model predictions from a musculoskeletal hand model in comparison to the uncertainty of these input parameters. For this purpose, the kinematics and muscle activities of different hand movements (abduction of the fingers, abduction of the thumb, and flexion of the thumb) were recorded. One thousand simulations were calculated for each movement using the Latin hypercube sampling method with a corresponding variation of the muscle origin/insertion points and the cross-sectional area. Comparing the standard hand to simulations incorporating uncertainties of input parameters shows no major deviations in on- and off-set time point of muscle activities. About 60% of simulations are located within a ± 30% interval around the standard model concerning joint reaction forces. The comparison with the variation of the input data leads to the conclusion that the standard hand model is able to provide not over-scattered outcomes and, therefore, can be considered relatively stable. These results are of practical importance to the personalization of a musculoskeletal model with subject-specific bone geometries and hence changed muscle line of action.