Lebenswissenschaften und Ethik
Refine
Year of publication
Document Type
- Article (108)
- conference proceeding (article) (86)
- conference talk (37)
- conference proceeding (presentation, abstract) (30)
- Part of a Book (4)
- Doctoral Thesis (3)
- Moving Images (2)
- Other (2)
- conference proceeding (volume) (1)
- Edited collection (1)
Is part of the Bibliography
- no (277)
Keywords
- Biomechanik (13)
- Biomechanics (10)
- Simulation (10)
- Hüftgelenkprothese (9)
- Biomechanische Analyse (7)
- Stent (6)
- Bewegungsapparat (4)
- Finite element analysis (4)
- Spongiosa (4)
- biomechanics (4)
- AnyBody (3)
- Computerunterstütztes Verfahren (3)
- Deformation (3)
- ECMO (3)
- Finite-Elemente-Methode (3)
- Gait analysis (3)
- Inverse dynamics (3)
- Lumbar spine (3)
- Musculoskeletal simulation (3)
- Operationstechnik (3)
- Schultergelenk (3)
- THA (3)
- musculoskeletal simulation (3)
- Adhesives (2)
- Aerosols (2)
- Alter (2)
- Anisotropie (2)
- AnyBody Modeling System (2)
- Ballondilatation (2)
- Belastung (2)
- Biomaterial (2)
- Blood Viscosity (2)
- Breast augmentation (2)
- CFD (2)
- Catheters (2)
- Combined anteversion (2)
- Computertomografie (2)
- Coronary stenting (2)
- Flow visualisation (2)
- Implantation (2)
- Knochen (2)
- Knochenbruch (2)
- Lendenwirbelsäule (2)
- Mechanische Belastung (2)
- Membrane Oxygenator (2)
- Musculoskeletal Modeling (2)
- Nasal airflow (2)
- Numerische Strömungssimulation (2)
- Stiffness (2)
- Stress (2)
- Test (2)
- Tissue Engineering (2)
- Tomographic PIV (2)
- computational fluid dynamics (2)
- stem cells (2)
- total hip replacement (2)
- 3D measurement (1)
- 3D printing (1)
- 3D scan (1)
- 3D volumetry (1)
- 3D-Druck (1)
- ANEURYSMS (1)
- ANTERIOR CINGULATE CORTEX (1)
- ANTERIOR CRUCIATE LIGAMENT (1)
- APOPTOSIS (1)
- ARTERIES (1)
- ASCORBIC-ACID (1)
- ASIS (1)
- AUGMENTATION (1)
- Abduction tasks (1)
- Accoucheur (1)
- Acetabulum/physiology (1)
- Adaptive clinical trial (1)
- Aerodynamics (1)
- Aerosole (1)
- Altenpflege (1)
- Aluminum Silicates (1)
- Animals (1)
- Anisotropy (1)
- Antibiotika (1)
- Antioxidant (1)
- Arbeitsbedingungen (1)
- Arbeitshilfe (1)
- Assistenzsystem (1)
- Autologous bone graft (1)
- BIOREACTOR (1)
- BLOOD FLOW (1)
- BLOOD-VESSELS (1)
- BYPASS GRAFTS (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Beweglichkeit (1)
- Bewegung (1)
- Bewegungsanalyse (1)
- Bewegungsanalyse <Technik> (1)
- Bildbasierte Verfahren (1)
- Bildgebendes Verfahren (1)
- Bioactivity (1)
- Biological models (1)
- Biologische Modelle (1)
- Biomechanical Phenomena (1)
- Biomechanical investigation (1)
- Blutdruck (1)
- Blutgefäß (1)
- Body Weight (1)
- Bond strength (1)
- Bone harvesting (1)
- Bone imaging (1)
- Bone substitute materials (1)
- Bovine cartilage (1)
- Breast cancer (1)
- Breast implant (1)
- Breathing cycle (1)
- Brusterhaltende Therapie (1)
- Brustkorb (1)
- Brustwirbelsäule (1)
- CANCER (1)
- CELT (1)
- CEUS (1)
- COMPLEX (1)
- CONNECTIVITY (1)
- CONSTRUCTS (1)
- CONTRAST AGENT (1)
- COORDINATE SYSTEM (1)
- COVID-19 (1)
- CULTURES (1)
- Cancellous bone (1)
- Cancer-cells (1)
- Cardiovascular stents (1)
- Cartilage samples (1)
- Catheter (1)
- Ceramics (1)
- Characterisation testing (1)
- Classification (1)
- Coagulation disorder (1)
- Coherent motion detection (1)
- Communication engineering education (1)
- Computational Fluid Dynamics Simulation (1)
- Computer-assisted surgery (1)
- Computersimulation (1)
- Computertomographie (1)
- Conventional surgery (1)
- Convolutional neural networks (1)
- Coronary (1)
- Coronary artery (1)
- Corrosion rate (1)
- Corrosion test (1)
- Covid-19 (1)
- Crimping (1)
- Cup medialisation (1)
- DEFICIENCY (1)
- Damage (1)
- Damage mechanism (1)
- Deep Learning (1)
- Deep learning fluid mechanics (1)
- Deformation behaviour (1)
- Dental Materials (1)
- Dental alloys (1)
- Dental membrane (1)
- Dentin (1)
- Depression (1)
- Deutschland (1)
- Distraktion (1)
- Dragonfly (1)
- Dragonfly wing (1)
- Dreidimensionale Bildverarbeitung (1)
- EARLY OSTEOARTHRITIS (1)
- ECMO SYSTEMS (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Elasticity (1)
- Electromyography (1)
- Elektromyographie (1)
- Elite athletes (1)
- Ellenbogenstabilität (1)
- Empfindlichkeit (1)
- Endotracheal Intubation (1)
- Endotracheal Tube (1)
- Equipment Failure Analysis/statistics & numerical data (1)
- Ergonomics (1)
- Ermüdung (1)
- Ermüdungsbruch (1)
- Euler-Bernoulli-Beam-Theory (1)
- Ex vivo porcine stent model (1)
- Extracorporeal Membrane Oxygenation/instrumentation (1)
- Extracorporeal membrane oxygenation (ECMO) (1)
- FEA (1)
- FORCE (1)
- FRONTAL-CORTEX (1)
- Fat graft (1)
- Fatigue (1)
- Fatigue fracture (1)
- Feedback (1)
- Femur first (1)
- Finite element (1)
- Finite element analysis (FEA) (1)
- Flow (1)
- Fluid Mechanics (1)
- Football (1)
- Functional MRI (1)
- Funktionelle Anatomie (1)
- GAIT (1)
- GULO (1)
- Gait (1)
- Ganganalyse (1)
- Gefäßverletzung (1)
- Gehen (1)
- Geometrical imperfections (1)
- Geometrie (1)
- Germany (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Gliding Flight (1)
- Ground Reaction Force Prediction (1)
- HYDROGELS (1)
- Haltungsfehler (1)
- Haut (1)
- Head trauma (1)
- Heat treatment (1)
- Hemodynamics (1)
- Hip Prosthesis (1)
- Hochschulschrift (1)
- Humans (1)
- Hyaluronsäure (1)
- Hämodynamik (1)
- Hüftgelenk (1)
- Hüftgelenkpfanne (1)
- IMMEDIATE BREAST RECONSTRUCTION (1)
- IMU (1)
- IN-VITRO (1)
- INFLAMMATION (1)
- INJURY (1)
- INSTABILITY (1)
- Iliac crest (1)
- Immunoflorescence (1)
- Indentation test (1)
- Indian ink (1)
- Inertial Measurement Units (1)
- Injury score (1)
- Internal fixator (1)
- Ion release (1)
- Joint Reaction Forces (1)
- Kardiovaskuläres System (1)
- Kennzeichnung (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenbildung (1)
- Knochenentnahme (1)
- Knochenersatz (1)
- Knorpel (1)
- Knowledge engineering (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Koronare Herzkrankheit (1)
- Koronarendoprothese (1)
- Körper (1)
- Körperliche Belastung (1)
- Künstliche Intelligenz (1)
- Laser powder bed fusion (L-PBF) (1)
- Lasers (1)
- Lastverteilung <Statik> (1)
- Le Fort III (1)
- Leg length (1)
- Leistungssportler (1)
- Leitfähgkeit (1)
- Lendenwirbelsäulenkrankheit (1)
- Ligament stiffness (1)
- Linear Models (1)
- Lipofilling (1)
- MAMMAPLASTY (1)
- MDCT (1)
- MECHANICAL PROPERTIES (1)
- MECHANICAL-PROPERTIES (1)
- MEDICINAL PLANTS (1)
- MITOCHONDRIAL DYSFUNCTION (1)
- MOTION (1)
- MRI (1)
- MULTIDETECTOR COMPUTED-TOMOGRAPHY (1)
- Magnesium (1)
- Mammoplastik (1)
- Material properties (1)
- Measurement and testing (1)
- Mechanical Phenomena (1)
- Mechanical behaviour (1)
- Mechanical properties (1)
- Medizintechnik (1)
- Mehrkörpersimulation (1)
- Membrane/classification/standards/statistics & numerical data (1)
- Meniskusschaden (1)
- Mensch (1)
- Mesenchymzelle (1)
- Method labeling (1)
- Micro-structure (1)
- Minimal-invasive Chirurgie (1)
- Modell (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Movement (1)
- Multibody Simulation (1)
- Multiphase blood flow (1)
- Multiresistant (1)
- Mund-Kiefer-Gesichts-Chirurgie (1)
- Muscle (1)
- Muscle influence (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscles (1)
- Muscoloskeletal model (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskelkraft (1)
- Muskuloskelettale Simulation (1)
- Nabelvene (1)
- Nachweis (1)
- Nanoparticles (1)
- Neutrophil extracellular traps (NET) (1)
- Non-Newtonian multiphase flow (1)
- Numerische Methode (1)
- OSTEOARTHRITIS (1)
- OUTCOMES (1)
- OXIDATIVE STRESS (1)
- OXYGENATION (1)
- Offset (1)
- Orthopädische Chirurgie (1)
- Osteoconductive (1)
- Osteomyelitis (1)
- Osteosynthese (1)
- Osteotomie (1)
- Outcome (1)
- PCR (1)
- PEEK (1)
- PHOSPHATIDYLCHOLINE (1)
- PLATELET ACTIVATION (1)
- PLATELET-RICH PLASMA (1)
- POLYPHENOLS (1)
- PREDICTOR (1)
- Pandemie (1)
- Parameter study (1)
- Particle Image Velocimetry (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Perceptual learning (1)
- Percutaneous coronary intervention (1)
- Physiological Breathing (1)
- Polymer (1)
- Polymerase-Kettenreaktion (1)
- Polymers (1)
- Powders (1)
- Precious alloys (1)
- Primary Health Care/statistics & numerical data (1)
- Prognose (1)
- Prosthesis Design (1)
- Prüfung (1)
- Pulleys (1)
- QUANTIFICATION (1)
- RADIATION-THERAPY (1)
- RECIPIENT-SITE (1)
- RTMS (1)
- Radiotherapy (1)
- Randomized (1)
- Rapamycin (1)
- Rapid prototyping (1)
- Reconstruction (1)
- Resilience, psychological (1)
- Resilienz, psychologische (1)
- Resistance to corrosion (1)
- Respiratory Distress Syndrome/therapy (1)
- Restenosis (1)
- Retrospective Studies (1)
- Rind (1)
- Robot sensing systems (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- SARS-CoV-2 (1)
- SHAPE (1)
- STIFFNESS (1)
- STIMULATION (1)
- Sagittal balance (1)
- Schulkind (1)
- Schädel-Hirn-Trauma (1)
- Second-harmonic generation imaging (1)
- Sepsis (1)
- Severity of Illness Index (1)
- Shear Raed Induced Coagulation (1)
- Shear Rate Induced Coagulation (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Silent Breathing (1)
- Softening (1)
- Specimen preparation and treatment (1)
- Speedcourt (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Stabilität (1)
- Steifigkeit (1)
- Stent design (1)
- Stent implantation (1)
- Stent screening (1)
- Stent-artery interaction (1)
- Stents (1)
- Stress, Mechanical (1)
- Surface Properties (1)
- Surface treatments (1)
- Surgical smoke (1)
- T-peel configuration (1)
- THR (1)
- THROMBOSIS (1)
- THROMBOTIC DEPOSITS (1)
- TMS (1)
- Task analysis (1)
- Testing biomaterials (1)
- Thoracolumbar spine (1)
- Thrombocytopenia (1)
- Time factors (1)
- Tinte (1)
- Topographic shift (1)
- Torus (1)
- Total hip athroplasty (1)
- Tracheotomies (1)
- Transfer functions (1)
- Turbulent Kinetic Energy (1)
- Valves (1)
- Vascular injury (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vertebra (1)
- Violinspiel (1)
- Viscoelasticity (1)
- Webcast (1)
- Werkstoff (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- additive manufacturing (1)
- aerodynamics (1)
- anchorage (1)
- anti-Inflammatory agent (1)
- attention (1)
- biomaterial (1)
- biomechanical implant test (1)
- blood (1)
- bone biomechanics (1)
- brain mapping (1)
- cancer (1)
- cell- free DNA (1)
- cell-enriched lipotransfer (1)
- centrifugal disc finishing (1)
- chemical synthesis (1)
- children (1)
- chondrocytes (1)
- coagulation (1)
- collagen (1)
- combined anteversion (1)
- component position (1)
- computer-assisted orthopaedic surgery (1)
- cortical plasticity (1)
- critical hip joint loading (1)
- crosstalk (1)
- cup loading (1)
- data-driven analysis (1)
- design (1)
- distraction (1)
- drug-eluting stent (1)
- dynamic multiplanar loading (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- enhanced resorption (1)
- esb (1)
- extracellular matrix (1)
- fMRI BOLD (1)
- fat grafting (1)
- femoral fracture (1)
- femoral offset (1)
- finite elements analysis (1)
- flexibility ellipsis (1)
- force angles (1)
- force pathways (1)
- form-finding (1)
- functional outcome (1)
- functionality (1)
- fused deposition modeling (1)
- fused filament fabrication (1)
- gait analysis (1)
- gargle (1)
- gliding flight (1)
- happiness (1)
- high-impact exercisess (1)
- high-performance polymers (1)
- hip contact force (1)
- hip fractureg (1)
- histological evaluation (1)
- human articular cartilage (1)
- human umbilical vein (1)
- humeroradial stability (1)
- hydrogels (1)
- immune system (1)
- immunothrombosis (1)
- implant migration (1)
- inertial measurement units (1)
- infiltration (1)
- inflammation (1)
- influence parameters (1)
- insect flight (1)
- kinematics (1)
- language assessment (1)
- ligaments (1)
- lipoaspirate (1)
- lipograft (1)
- liposomal packing (1)
- lower back load (1)
- lumbar geometry (1)
- lumbar spine (1)
- macular degeneration (1)
- mass finishing (1)
- mechanical compliance (1)
- membrane lung (1)
- meniscus (1)
- multifidus (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- neutrophil extracellular traps (1)
- optical motion capture (1)
- osteoarthritis (1)
- osteoporosis (1)
- pandemic (1)
- patient specific loading (1)
- pelvic floor (1)
- pelvic tilt (1)
- perceptual learning (1)
- pharmacology (1)
- pooling (1)
- post-processing of 3D printed parts (1)
- proteolysis (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rapamycin (1)
- resting-state fMRI (1)
- rheological model (1)
- rim loading (1)
- sadness (1)
- scaffolds (1)
- schools (1)
- sensitivity study (1)
- sensors (1)
- shear induced clotting (1)
- shoulder elevation (1)
- shoulder joint force (1)
- simplified loading model (1)
- sirolimus (1)
- small calibre graft (1)
- sonography (1)
- stent platform (1)
- subject-specific musculoskeletal modeling (1)
- subluxation (1)
- surface electromyography (1)
- surface treatment (1)
- surgery (1)
- tannic acid (1)
- task-based fMRI (1)
- tensegrity joint (1)
- therapeutic use (1)
- three-dimensional computed tomography analysis (1)
- tissue engineering (1)
- tissue regeneration (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- toxicity (1)
- tracheobronchial mucus (1)
- vWF (1)
- validation (1)
- vascular tissue engineering (1)
- vector (1)
- violin (1)
- viscoelasticity (1)
- visual cortex (1)
- vitamin C (1)
- von Willebrand factor (1)
- wearable motion-tracking sensors (1)
- white adipose tissue (1)
- zwitterionic monomers (1)
- µCT (1)
Institute
- Fakultät Maschinenbau (277) (remove)
Begutachtungsstatus
- peer-reviewed (100)
- begutachtet (10)
Objectives: The mechanical properties and seeding with endothelial cells were investigated in fresh and cryopreserved human umbilical vein.
Methods: Human umbilical veins (HUV) were frozen in Euro-Collins/1M DMSO at –1°C/min and stored in liquid nitrogen. Stress-strain relationships of fresh and thawed veins were determined in an uniaxial tension-testing rig. HUV endothelial cells (HUVEC) were seeded onto denuded HUV under static conditions and grown for 3d. Luminal surfaces were analyzed by scanning electron microscopy. Calcein-stained cells were seeded hyperconfluently to determine the cell retention capacity of fresh and cryopreserved veins.
Results: The stress-strain relationships of HUV followed a biphasic pattern typical for natural vessels. Neither the failure stress (2.71±0.36 vs. 3.25±0.97 N, n=3) nor the displacement required to achieve failure (9.73±0.9 vs. 7.43±2.07mm, n=3) were altered by cryopreservation. The burst pressure was estimated as approx. 1000mm Hg within the limitations of the uniaxial model. HUVEC seeded onto denuded HUV formed patches (at 9E3 cells per cm2) or an almost confluent endothelium (at 3E4 cells per cm2) within three days. The capacity to retain seeded HUVEC of denuded HUV was not altered by cryopreservation (1.15±0.08E5 vs. 1.26±0.14E5 cells per cm2, n=6).
Conclusions: The burst pressure of HUV seems to be sufficiently high for the human arterial circulation and is not altered by cryopreservation. HUVEC can establish a confluent endothelium on denuded HUV. Therefore HUV appears to be a suitable storable scaffold for vascular tissue engineering.
Tissue-engineered vessel grafts have to mimic the biomechanical properties of native blood vessels. Manufacturing processes often condition grafts to adapt them to the target flow conditions. Graft stiffness is influenced by material properties and dimensions and determines graft compliance. This proof-of-concept study evaluated a contact-free method to monitor biomechanical properties without compromising sterility. Forced vibration response analysis was performed on human umbilical vein (HUV) segments mounted in a buffer-filled tubing system. A linear motor and a dynamic signal analyser were used to excite the fluid by white noise (0-200 Hz). Vein responses were read out by laser triangulation and analysed by fast Fourier transformation. Modal analysis was performed by monitoring multiple positions of the vessel surface. As an inverse model of graft stiffening during conditioning, HUV were digested proteolytically, and the course of natural frequencies (NFs) was monitored over 120 min. Human umbilical vein showed up to five modes with NFs in the range of 5-100 Hz. The first natural frequencies of HUV did not alter over time while incubated in buffer (p = 0.555), whereas both collagenase (-35%, p = 0.0061) and elastase (-45%, p < 0.001) treatments caused significant decreases of NF within 120 min. Decellularized HUV showed similar results, indicating that changes of the extracellular matrix were responsible for the observed shift in NF. Performing vibration response analysis on vessel grafts is feasible without compromising sterility or integrity of the samples. This technique allows direct measurement of stiffness as an important biomechanical property, obviating the need to monitor surrogate parameters. Copyright (C) 2016 John Wiley & Sons, Ltd.
Bioresorbable materials are under investigation due to their promising properties for applications as implant material. This study is about the degradation and bioactivity behaviour of magnesium foils, which allegorize dental membranes. The degradation behaviour including pitting corrosion during immersion tests can be precisely observed using micro-computed tomography. Using the bioactivity test according to Kokubo, it is shown that magnesium has strong Ca-phosphate layer formation correlated with high degradation. Therefore, magnesium foils appear to hold a great potential for bone implant application.
One of the main goals in reconstructing rotator cuff tears is the restoration of glenohumeral joint stability, which is subsequently of utmost importance in order to prevent degenerative damage such as superior labral anterior posterior (SLAP) lesion, arthrosis, and malfunction. The goal of the current study was to facilitate musculoskeletal models in order to estimate glenohumeral instability introduced by muscle weakness due to cuff lesions. Inverse dynamics simulations were used to compute joint reaction forces for several static abduction tasks with different muscle weakness. Results were compared with the existing literature in order to ensure the model validity. Further arm positions taken from activities of daily living, requiring the rotator cuff muscles were modeled and their contribution to joint kinetics computed. Weakness of the superior rotator cuff muscles (supraspinatus; infraspinatus) leads to a deviation of the joint reaction force to the cranial dorsal rim of the glenoid. Massive rotator cuff defects showed higher potential for glenohumeral instability in contrast to single muscle ruptures. The teres minor muscle seems to substitute lost joint torque during several simulated muscle tears to maintain joint stability. Joint instability increases with cuff tear size. Weakness of the upper part of the rotator cuff leads to a joint reaction force closer to the upper glenoid rim. This indicates the comorbidity of cuff tears with SLAP lesions. The teres minor is crucial for maintaining joint stability in case of massive cuff defects and should be uprated in clinical decision-making.
Thoracolumbar spine model with articulated ribcage for the prediction of dynamic spinal loading
(2016)
Musculoskeletal modeling offers an invaluable insight into the spine biomechanics. A better understanding of thoracic spine kinetics is essential for understanding disease processes and developing new prevention and treatment methods. Current models of the thoracic region are not designed for segmental load estimation, or do not include the complex construct of the ribcage, despite its potentially important role in load transmission. In this paper, we describe a numerical musculoskeletal model of the thoracolumbar spine with articulated ribcage, modeled as a system of individual vertebral segments, elastic elements and thoracic muscles, based on a previously established lumbar spine model and data from the literature. The inverse dynamics simulations of the model allow the prediction of spinal loading as well as costal joints kinetics and kinematics. The intradiscal pressure predicted by the model correlated well (R2=0.89) with reported intradiscal pressure measurements, providing a first validation of the model. The inclusion of the ribcage did not affect segmental force predictions when the thoracic spine did not perform motion. During thoracic motion tasks, the ribcage had an important influence on the predicted compressive forces and muscle activation patterns. The compressive forces were reduced by up to 32%, or distributed more evenly between thoracic vertebrae, when compared to the predictions of the model without ribcage, for mild thoracic flexion and hyperextension tasks, respectively. The presented musculoskeletal model provides a tool for investigating thoracic spine loading and load sharing between vertebral column and ribcage during dynamic activities. Further validation for specific applications is still necessary.
Thoracolumbar spine model with articulated rigcage for the prediction of dynamic spinal loading
(2015)
BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough.
Common Schanz screw systems can be used to stabilize pelvic ring fractures. In order to accommodate for different patient’s requirements, implants can be placed in cranio-caudal direction into the os ilium (T1), or into the supraacetabular bone canal, and thus, in dorso-ventral direction (T2). Whereas both techniques are currently used, no data of the biomechanical behavior is available up to this date. The aim of this study is to analyze, whether T2 shows biomechanical advantages with respect to tissue and implant stresses due to the enlarged bone-implant interface. Forces acting on the pelvis were analyzed using motion capture data of a gait cycle obtained by the utilization of a musculoskeletal simulation program. A three dimensional finite element (FE) model of the pelvis with grayscale-based material properties was generated. The muscle and joint reaction forces at toe-off were applied to the FE model and instable pelvis fractures were implemented. The osteosynthesis systems were positioned within the model in order to enable the comparison between the two different surgical techniques. Stresses and displacements were analyzed for bone tissue, fracture zone and implant.
T2 lead to approx. 30% larger displacements in the fracture zone. Von-Mises stresses were larger for T2 in the implant (80 MPa vs. 227 MPa), whereas T1 leads to larger stresses in the bone tissue (200 MPa vs. 140 MPa).
Both implantation techniques showed a good biomechanical behavior. Differences could be found with respect to tissue strains and deformations in the fracture zone. If bone quality or fracture healing are of concern, T2 or T1 should be used, respectively. However, both techniques seem to be applicable for cases with no special requirements. Further analyses aim to investigate the behavior under cyclic loading.
Results of WICOVIR Gargle Pool PCR Testing in German Schools Based on the First 100,000 Tests
(2021)
Background:
Opening schools and keeping children safe from SARS-CoV-2 infections at the same time is urgently needed to protect children from direct and indirect consequences of the COVID-19 pandemic. To achieve this goal, a safe, efficient, and cost-effective SARS-CoV-2 testing system for schools in addition to standard hygiene measures is necessary.
Methods:
We implemented the screening WICOVIR concept for schools in the southeast of Germany, which is based on gargling at home, pooling of samples in schools, and assessment of SARS-CoV-2 by pool rRT-PCR, performed decentralized in numerous participating laboratories. Depooling was performed if pools were positive, and results were transmitted with software specifically developed for the project within a day. Here, we report the results after the first 13 weeks in the project.
Findings:
We developed and implemented the proof-of-concept test system within a pilot phase of 7 weeks based on almost 17,000 participants. After 6 weeks in the main phase of the project, we performed >100,000 tests in total, analyzed in 7,896 pools, identifying 19 cases in >100 participating schools. On average, positive children showed an individual CT value of 31 when identified in the pools. Up to 30 samples were pooled (mean 13) in general, based on school classes and attached school staff. All three participating laboratories detected positive samples reliably with their previously established rRT-PCR standard protocols. When self-administered antigen tests were performed concomitantly in positive cases, only one of these eight tests was positive, and when antigen tests performed after positive pool rRT-PCR results were already known were included, 3 out of 11 truly positive tests were also identified by antigen testing. After 3 weeks of repetitive WICOVIR testing twice weekly, the detection rate of positive children in that cohort decreased significantly from 0.042 to 0.012 (p = 0.008).
Interpretation:
Repeated gargle pool rRT-PCR testing can be implemented quickly in schools. It is an effective, valid, and well-received test system for schools, superior to antigen tests in sensitivity, acceptance, and costs.