Lebenswissenschaften und Ethik
Refine
Year of publication
Document Type
- Article (105)
- conference proceeding (article) (86)
- conference talk (37)
- conference proceeding (presentation, abstract) (30)
- Part of a Book (4)
- Doctoral Thesis (3)
- Moving Images (2)
- Other (2)
- conference proceeding (volume) (1)
- Edited collection (1)
- Preprint (1)
- Report (1)
- Working Paper (1)
Is part of the Bibliography
- no (274)
Keywords
- Biomechanik (13)
- Biomechanics (10)
- Simulation (10)
- Hüftgelenkprothese (9)
- Biomechanische Analyse (7)
- Stent (6)
- Bewegungsapparat (4)
- Finite element analysis (4)
- Spongiosa (4)
- biomechanics (4)
- AnyBody (3)
- Computerunterstütztes Verfahren (3)
- Deformation (3)
- ECMO (3)
- Finite-Elemente-Methode (3)
- Gait analysis (3)
- Inverse dynamics (3)
- Lumbar spine (3)
- Musculoskeletal simulation (3)
- Operationstechnik (3)
- Schultergelenk (3)
- THA (3)
- musculoskeletal simulation (3)
- Adhesives (2)
- Aerosols (2)
- Alter (2)
- Anisotropie (2)
- AnyBody Modeling System (2)
- Ballondilatation (2)
- Belastung (2)
- Biomaterial (2)
- Blood Viscosity (2)
- Breast augmentation (2)
- CFD (2)
- Catheters (2)
- Combined anteversion (2)
- Computertomografie (2)
- Coronary stenting (2)
- Flow visualisation (2)
- Implantation (2)
- Knochen (2)
- Knochenbruch (2)
- Lendenwirbelsäule (2)
- Mechanische Belastung (2)
- Membrane Oxygenator (2)
- Musculoskeletal Modeling (2)
- Nasal airflow (2)
- Numerische Strömungssimulation (2)
- Stiffness (2)
- Stress (2)
- Test (2)
- Tissue Engineering (2)
- Tomographic PIV (2)
- computational fluid dynamics (2)
- stem cells (2)
- total hip replacement (2)
- 3D measurement (1)
- 3D scan (1)
- 3D volumetry (1)
- 3D-Druck (1)
- ANEURYSMS (1)
- ANTERIOR CINGULATE CORTEX (1)
- ANTERIOR CRUCIATE LIGAMENT (1)
- APOPTOSIS (1)
- ARTERIES (1)
- ASCORBIC-ACID (1)
- ASIS (1)
- AUGMENTATION (1)
- Abduction tasks (1)
- Accoucheur (1)
- Acetabulum/physiology (1)
- Adaptive clinical trial (1)
- Aerodynamics (1)
- Aerosole (1)
- Altenpflege (1)
- Aluminum Silicates (1)
- Animals (1)
- Anisotropy (1)
- Antibiotika (1)
- Antioxidant (1)
- Arbeitsbedingungen (1)
- Arbeitshilfe (1)
- Assistenzsystem (1)
- Autologous bone graft (1)
- BIOREACTOR (1)
- BLOOD FLOW (1)
- BLOOD-VESSELS (1)
- BYPASS GRAFTS (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Beweglichkeit (1)
- Bewegung (1)
- Bewegungsanalyse (1)
- Bewegungsanalyse <Technik> (1)
- Bildbasierte Verfahren (1)
- Bildgebendes Verfahren (1)
- Bioactivity (1)
- Biological models (1)
- Biologische Modelle (1)
- Biomechanical Phenomena (1)
- Biomechanical investigation (1)
- Blutdruck (1)
- Blutgefäß (1)
- Body Weight (1)
- Bond strength (1)
- Bone harvesting (1)
- Bone imaging (1)
- Bone substitute materials (1)
- Bovine cartilage (1)
- Breast cancer (1)
- Breast implant (1)
- Breathing cycle (1)
- Brusterhaltende Therapie (1)
- Brustkorb (1)
- Brustwirbelsäule (1)
- CANCER (1)
- CELT (1)
- CEUS (1)
- COMPLEX (1)
- CONNECTIVITY (1)
- CONSTRUCTS (1)
- CONTRAST AGENT (1)
- COORDINATE SYSTEM (1)
- COVID-19 (1)
- CULTURES (1)
- Cancellous bone (1)
- Cancer-cells (1)
- Cardiovascular stents (1)
- Cartilage samples (1)
- Catheter (1)
- Ceramics (1)
- Characterisation testing (1)
- Classification (1)
- Coherent motion detection (1)
- Communication engineering education (1)
- Computational Fluid Dynamics Simulation (1)
- Computer-assisted surgery (1)
- Computersimulation (1)
- Computertomographie (1)
- Conventional surgery (1)
- Convolutional neural networks (1)
- Coronary (1)
- Coronary artery (1)
- Corrosion rate (1)
- Corrosion test (1)
- Covid-19 (1)
- Crimping (1)
- Cup medialisation (1)
- DEFICIENCY (1)
- Damage (1)
- Damage mechanism (1)
- Deep Learning (1)
- Deep learning fluid mechanics (1)
- Deformation behaviour (1)
- Dental Materials (1)
- Dental alloys (1)
- Dental membrane (1)
- Dentin (1)
- Depression (1)
- Deutschland (1)
- Distraktion (1)
- Dragonfly (1)
- Dragonfly wing (1)
- Dreidimensionale Bildverarbeitung (1)
- EARLY OSTEOARTHRITIS (1)
- ECMO SYSTEMS (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Elasticity (1)
- Electromyography (1)
- Elektromyographie (1)
- Elite athletes (1)
- Ellenbogenstabilität (1)
- Empfindlichkeit (1)
- Endotracheal Intubation (1)
- Endotracheal Tube (1)
- Equipment Failure Analysis/statistics & numerical data (1)
- Ergonomics (1)
- Ermüdung (1)
- Ermüdungsbruch (1)
- Ex vivo porcine stent model (1)
- Extracorporeal Membrane Oxygenation/instrumentation (1)
- FEA (1)
- FORCE (1)
- FRONTAL-CORTEX (1)
- Fat graft (1)
- Fatigue (1)
- Fatigue fracture (1)
- Feedback (1)
- Femur first (1)
- Finite element (1)
- Finite element analysis (FEA) (1)
- Flow (1)
- Fluid Mechanics (1)
- Football (1)
- Functional MRI (1)
- Funktionelle Anatomie (1)
- GAIT (1)
- GULO (1)
- Gait (1)
- Ganganalyse (1)
- Gefäßverletzung (1)
- Gehen (1)
- Geometrical imperfections (1)
- Geometrie (1)
- Germany (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Gliding Flight (1)
- Ground Reaction Force Prediction (1)
- HYDROGELS (1)
- Haltungsfehler (1)
- Haut (1)
- Head trauma (1)
- Heat treatment (1)
- Hemodynamics (1)
- Hip Prosthesis (1)
- Hochschulschrift (1)
- Humans (1)
- Hyaluronsäure (1)
- Hämodynamik (1)
- Hüftgelenk (1)
- Hüftgelenkpfanne (1)
- IMMEDIATE BREAST RECONSTRUCTION (1)
- IMU (1)
- IN-VITRO (1)
- INFLAMMATION (1)
- INJURY (1)
- INSTABILITY (1)
- Iliac crest (1)
- Indentation test (1)
- Indian ink (1)
- Inertial Measurement Units (1)
- Injury score (1)
- Internal fixator (1)
- Ion release (1)
- Joint Reaction Forces (1)
- Kardiovaskuläres System (1)
- Kennzeichnung (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenbildung (1)
- Knochenentnahme (1)
- Knochenersatz (1)
- Knorpel (1)
- Knowledge engineering (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Koronare Herzkrankheit (1)
- Koronarendoprothese (1)
- Körper (1)
- Körperliche Belastung (1)
- Künstliche Intelligenz (1)
- Laser powder bed fusion (L-PBF) (1)
- Lasers (1)
- Lastverteilung <Statik> (1)
- Le Fort III (1)
- Leg length (1)
- Leistungssportler (1)
- Leitfähgkeit (1)
- Lendenwirbelsäulenkrankheit (1)
- Ligament stiffness (1)
- Linear Models (1)
- Lipofilling (1)
- MAMMAPLASTY (1)
- MDCT (1)
- MECHANICAL PROPERTIES (1)
- MECHANICAL-PROPERTIES (1)
- MEDICINAL PLANTS (1)
- MITOCHONDRIAL DYSFUNCTION (1)
- MOTION (1)
- MRI (1)
- MULTIDETECTOR COMPUTED-TOMOGRAPHY (1)
- Magnesium (1)
- Mammoplastik (1)
- Material properties (1)
- Measurement and testing (1)
- Mechanical Phenomena (1)
- Mechanical behaviour (1)
- Mechanical properties (1)
- Medizintechnik (1)
- Mehrkörpersimulation (1)
- Membrane/classification/standards/statistics & numerical data (1)
- Meniskusschaden (1)
- Mensch (1)
- Mesenchymzelle (1)
- Method labeling (1)
- Micro-structure (1)
- Minimal-invasive Chirurgie (1)
- Modell (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Movement (1)
- Multibody Simulation (1)
- Multiphase blood flow (1)
- Multiresistant (1)
- Mund-Kiefer-Gesichts-Chirurgie (1)
- Muscle (1)
- Muscle influence (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscles (1)
- Muscoloskeletal model (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskelkraft (1)
- Muskuloskelettale Simulation (1)
- Nabelvene (1)
- Nachweis (1)
- Nanoparticles (1)
- Non-Newtonian multiphase flow (1)
- Numerische Methode (1)
- OSTEOARTHRITIS (1)
- OUTCOMES (1)
- OXIDATIVE STRESS (1)
- OXYGENATION (1)
- Offset (1)
- Orthopädische Chirurgie (1)
- Osteoconductive (1)
- Osteomyelitis (1)
- Osteosynthese (1)
- Osteotomie (1)
- Outcome (1)
- PCR (1)
- PHOSPHATIDYLCHOLINE (1)
- PLATELET ACTIVATION (1)
- PLATELET-RICH PLASMA (1)
- POLYPHENOLS (1)
- PREDICTOR (1)
- Pandemie (1)
- Parameter study (1)
- Particle Image Velocimetry (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Perceptual learning (1)
- Percutaneous coronary intervention (1)
- Physiological Breathing (1)
- Polymer (1)
- Polymerase-Kettenreaktion (1)
- Polymers (1)
- Powders (1)
- Precious alloys (1)
- Primary Health Care/statistics & numerical data (1)
- Prognose (1)
- Prosthesis Design (1)
- Prüfung (1)
- Pulleys (1)
- QUANTIFICATION (1)
- RADIATION-THERAPY (1)
- RECIPIENT-SITE (1)
- RTMS (1)
- Radiotherapy (1)
- Randomized (1)
- Rapamycin (1)
- Rapid prototyping (1)
- Reconstruction (1)
- Resilience, psychological (1)
- Resilienz, psychologische (1)
- Resistance to corrosion (1)
- Respiratory Distress Syndrome/therapy (1)
- Restenosis (1)
- Retrospective Studies (1)
- Rind (1)
- Robot sensing systems (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- SARS-CoV-2 (1)
- SHAPE (1)
- STIFFNESS (1)
- STIMULATION (1)
- Sagittal balance (1)
- Schulkind (1)
- Schädel-Hirn-Trauma (1)
- Second-harmonic generation imaging (1)
- Severity of Illness Index (1)
- Shear Raed Induced Coagulation (1)
- Shear Rate Induced Coagulation (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Silent Breathing (1)
- Softening (1)
- Specimen preparation and treatment (1)
- Speedcourt (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Stabilität (1)
- Steifigkeit (1)
- Stent design (1)
- Stent implantation (1)
- Stent screening (1)
- Stent-artery interaction (1)
- Stents (1)
- Stress, Mechanical (1)
- Surface Properties (1)
- Surface treatments (1)
- Surgical smoke (1)
- T-peel configuration (1)
- THR (1)
- THROMBOSIS (1)
- THROMBOTIC DEPOSITS (1)
- TMS (1)
- Task analysis (1)
- Testing biomaterials (1)
- Thoracolumbar spine (1)
- Time factors (1)
- Tinte (1)
- Topographic shift (1)
- Torus (1)
- Total hip athroplasty (1)
- Tracheotomies (1)
- Transfer functions (1)
- Turbulent Kinetic Energy (1)
- Valves (1)
- Vascular injury (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vertebra (1)
- Violinspiel (1)
- Viscoelasticity (1)
- Webcast (1)
- Werkstoff (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- aerodynamics (1)
- anchorage (1)
- anti-Inflammatory agent (1)
- attention (1)
- biomaterial (1)
- biomechanical implant test (1)
- blood (1)
- brain mapping (1)
- cancer (1)
- cell- free DNA (1)
- cell-enriched lipotransfer (1)
- chemical synthesis (1)
- children (1)
- chondrocytes (1)
- coagulation (1)
- collagen (1)
- combined anteversion (1)
- component position (1)
- computer-assisted orthopaedic surgery (1)
- cortical plasticity (1)
- critical hip joint loading (1)
- crosstalk (1)
- cup loading (1)
- data-driven analysis (1)
- design (1)
- distraction (1)
- drug-eluting stent (1)
- dynamic multiplanar loading (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- enhanced resorption (1)
- esb (1)
- extracellular matrix (1)
- fMRI BOLD (1)
- fat grafting (1)
- femoral offset (1)
- flexibility ellipsis (1)
- force angles (1)
- force pathways (1)
- form-finding (1)
- functional outcome (1)
- functionality (1)
- gait analysis (1)
- gargle (1)
- gliding flight (1)
- happiness (1)
- high-impact exercisess (1)
- hip contact force (1)
- hip fractureg (1)
- histological evaluation (1)
- human articular cartilage (1)
- human umbilical vein (1)
- humeroradial stability (1)
- hydrogels (1)
- immune system (1)
- implant migration (1)
- inertial measurement units (1)
- infiltration (1)
- inflammation (1)
- influence parameters (1)
- insect flight (1)
- kinematics (1)
- language assessment (1)
- ligaments (1)
- lipoaspirate (1)
- lipograft (1)
- liposomal packing (1)
- lower back load (1)
- lumbar geometry (1)
- lumbar spine (1)
- macular degeneration (1)
- mechanical compliance (1)
- membrane lung (1)
- meniscus (1)
- multifidus (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- neutrophil extracellular traps (1)
- optical motion capture (1)
- osteoarthritis (1)
- osteoporosis (1)
- pandemic (1)
- patient specific loading (1)
- pelvic floor (1)
- pelvic tilt (1)
- perceptual learning (1)
- pharmacology (1)
- pooling (1)
- proteolysis (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rapamycin (1)
- resting-state fMRI (1)
- rheological model (1)
- rim loading (1)
- sadness (1)
- scaffolds (1)
- schools (1)
- sensitivity study (1)
- sensors (1)
- shear induced clotting (1)
- shoulder elevation (1)
- shoulder joint force (1)
- sirolimus (1)
- small calibre graft (1)
- sonography (1)
- stent platform (1)
- subject-specific musculoskeletal modeling (1)
- subluxation (1)
- surface electromyography (1)
- surgery (1)
- tannic acid (1)
- task-based fMRI (1)
- tensegrity joint (1)
- therapeutic use (1)
- three-dimensional computed tomography analysis (1)
- tissue engineering (1)
- tissue regeneration (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- toxicity (1)
- tracheobronchial mucus (1)
- vWF (1)
- validation (1)
- vascular tissue engineering (1)
- vector (1)
- violin (1)
- viscoelasticity (1)
- visual cortex (1)
- vitamin C (1)
- von Willebrand factor (1)
- wearable motion-tracking sensors (1)
- white adipose tissue (1)
- zwitterionic monomers (1)
- µCT (1)
Institute
- Fakultät Maschinenbau (274) (remove)
Begutachtungsstatus
- peer-reviewed (97)
- begutachtet (10)
Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics
(2024)
BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research.
METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems.
RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements.
CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models.
Pelvic floor dysfunction is a common problem in women and has a negative impact ontheir quality of life. The aim of this review was to provide a general overview of the current state oftechnology used to assess pelvic floor functionality. It also provides literature research of the phys-iological and anatomical factors that correlate with pelvic floor health. The systematic review wasconducted according to the PRISMA guidelines. PubMed, ScienceDirect, Cochrane Library andIEEE databases were searched for publications on sensor technology for the assessment of pelvicfloor functionality. Anatomical and physiological parameters were identified through a manualsearch. In the systematic review 115 publications were included. 12 different sensor technologieswere identified. Information on the obtained parameters, sensor position, test activities and subjectcharacteristics were prepared in tabular form from each publication. 16 anatomical and physiologi- cal parameters influencing pelvic floor health were identified in 17 published studies and rankedfor their statistical significance. Taken together, this review could serve as a basis for the develop-ment of novel sensors which could allow for quantifiable prevention and diagnosis, as well as par-ticularized documentation of rehabilitation processes related to pelvic floor dysfunctions.
Pelvic floor dysfunction is a common problem in women and has a negative impact on their quality of life. The aim of this review was to provide a general overview of the current state of technology used to assess pelvic floor functionality. It also provides literature research of the physiological and anatomical factors that correlate with pelvic floor health. This systematic review was conducted according to the PRISMA guidelines. The PubMed, ScienceDirect, Cochrane Library, and IEEE databases were searched for publications on sensor technology for the assessment of pelvic floor functionality. Anatomical and physiological parameters were identified through a manual search. In the systematic review, 114 publications were included. Twelve different sensor technologies were identified. Information on the obtained parameters, sensor position, test activities, and subject characteristics was prepared in tabular form from each publication. A total of 16 anatomical and physiological parameters influencing pelvic floor health were identified in 17 published studies and ranked for their statistical significance. Taken together, this review could serve as a basis for the development of novel sensors which could allow for quantifiable prevention and diagnosis, as well as particularized documentation of rehabilitation processes related to pelvic floor dysfunctions.
Extracorporeal membrane oxygenation (ECMO) was established as a treatment for severe cardiac or respiratory disease. Intra-device clot formation is a common risk. This is based on complex coagulation phenomena which are not yet sufficiently understood. The objective was the development and validation of a methodology to capture the key properties of clots deposed in membrane lungs (MLs), such as clot size, distribution, burden, and composition. One end-oftherapy PLS ML was examined. Clot detection was performed using multidetector computed tomography (MDCT), microcomputed tomography (μCT), and photography of fiber mats (fiber mat imaging, FMI). Histological staining was conducted for von Willebrand factor (vWF), platelets (CD42b, CD62P), fibrin, and nucleated cells (4′, 6-diamidino-2-phenylindole, DAPI). The three imaging
methods showed similar clot distribution inside the ML. Independent of the imaging method, clot loading was detected predominantly in the inlet chamber of the ML. The μCT had the highest accuracy. However, it was more expensive and time consuming than MDCT or FMI. The MDCT detected the clots with low scanning time. Due to its lower resolution, it only showed clotted areas but not
the exact shape of clot structures. FMI represented the simplest variant, requiring little effort and resources. FMI allowed clot localization and calculation of clot volume. Histological evaluation indicated omnipresent immunological deposits throughout the ML. Visually clot-free areas were covered with leukocytes and platelets forming platelet-leukocyte aggregates (PLAs). Cells were embedded in vWF cobwebs, while vWF fibers were negligible. In conclusion, the presented
methodology allowed adequate clot identification and histological classification
of possible thrombosis markers such as PLAs.
The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes.
Preliminary considerations on the form-finding of a tensegrity joint to be used in dynamic orthoses
(2024)
Early motion therapy plays an important role for effective long-term healing of joint injuries. In many cases, conventional dynamic orthoses fail to address the intricate movement possibilities of the underlying joints, limited by their simplistic joint representations, often represented by revolute joints, enabling rotations by only one axis. In this paper, a two-dimensional compliant tensegrity joint for use in biomedical applications is investigated. It consists of two compressed members and five compliant tensioned members. Relative movement possibilities are realized by the intrinsic compliance of the structure. In the development of these systems, the first step is the determination of the static stable equilibrium. This analysis is conducted in this paper by considering the potential energy approach or by using the geometric nonlinear finite element method. The mechanical behavior of the structure is assessed with a specific emphasis on its mechanical compliance. The primary objective of this study is the investigation of the influence of structural parameters on the overall stiffness and movability of the structure. The results underscore the significant effect of member parameters on the stiffness and movability of the compliant tensegrity joint, particularly under varying load magnitudes. These findings provide insights for optimizing the joint’s performance, contributing to its potential application in advanced orthotic and exoskeleton devices.
Following a ban on many materials containing bisphenol-A, new bisphenol-free Boron silicates have been found as substitutes. The purpose of this study is to describe the mechanical properties of these bisphenol-free magnetoactive borosilicate polymers containing hard magnetic particles. Samples of 0%, 33% and 66% by wt. were loaded for compression using a universal testing machine. The maximum forces occurring for different travel speeds were compared before and after post-magnetization treatments. The post-magnetization included 2 stages. In addition, the change in mechanical properties within 24 hours after the post-magnetization process was investigated. Furthermore, the influence of speed and particle content were investigated. In general, there is a correlation between the required compressive force and, the level of post-magnetization stress, the increase in travel speed and particle content in the boron silicate. Comparison of the non-post-magnetized and post-magnetized samples using two-tailed t-tests shows that the p-values for all weight fraction changes in NdPrFeB particles and travel speeds are less than 0.001. Also, a comparison between tests in which the traverse speed was varied also showed significant changes in the resulting compression forces. The same is valid for changes in the weight ratio of the NdPrFeB particles in the samples. For post-magnetized samples, no significant difference can be observed in the first 24 hours following magnetization. In summary, the material presents viscoelastic, plastic force-displacement behavior, which can be well recognized by its bi-linear curve shape.
The investigation shows that borosilicate polymers based on NdPrFeB can have their mechanical behavior modified and controlled by post-magnetization processes. This opens new possibilities for many future applications.