Energie und Mobilität
Refine
Year of publication
Document Type
- conference proceeding (article) (168)
- Article (143)
- Part of a Book (41)
- conference talk (32)
- Report (19)
- conference proceeding (presentation, abstract) (8)
- Book (7)
- Master's Thesis (4)
- Preprint (4)
- Part of Periodical (3)
Is part of the Bibliography
- no (431)
Keywords
- Energiewende (27)
- Erneuerbare Energien (27)
- Klimaneutralität (22)
- Power-to-Gas (21)
- Sektorenkopplung (16)
- Energiespeicher (14)
- Power-to-X (9)
- Wasserstoff (8)
- Netzplanung (7)
- Blindleistung (6)
Institute
- Fakultät Elektro- und Informationstechnik (240)
- Fakultät Maschinenbau (155)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (76)
- Combustion Engines and Emissions Control Laboratory (CEEC) (40)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energienetze (38)
- Labor Elektrische Maschinen und Antriebstechnik (37)
- Computational Mechanics and Materials Lab (CMM) (20)
- Technologie-Campus Neustadt an der Donau (20)
- Labor Intelligente Materialien und Strukturen (17)
- Fakultät Informatik und Mathematik (15)
Begutachtungsstatus
- peer-reviewed (187)
- begutachtet (15)
Experiments and fracture modeling of high-strength pipelines for high and low stress triaxiality
(2012)
This paper provides results from a comprehensive study on mechanical characterization of high-strength pipeline steel, grade X100 using experimental and numerical methods. The material was characterized for anisotropic plasticity, fracture initiation for various states of stress, (pre-cracked) fracture toughness and uncracked ductility. The experimental program included tests on flat butterfly-shaped, central hole, notched and circular disk specimens for low stress triaxiality levels; as well as tests on round notched bar specimens and SENT fracture mechanics tests, for high values of stress triaxiality. This program covered a wide range of stress conditions and demonstrated its effect on the material resistance. Parallel to the experimental study, detailed numerical investigations were carried out to simulate all different experimental tests. Using an inverse method, a 3-parameter calibration was performed on the Modified Mohr-Coulomb (MMC) fracture model. Subsequently, the predictive capabilities of the MMC were evaluated by the comparison to the fracture toughness tests results, used extensively in the pipeline industry. The capabilities of the MIT fracture model have been demonstrated on an example of high strength offshore steel, X100. The outcome of this study was not only to provide, the overall characterization of the fracture behavior of this material as an example, but also to present the methodology on how to use the MMC model as a practical tool in pipeline design.
This paper focuses on the characterization of the fracture performance of X100 material in transition temperature region using both experimental and numerical methods. The ductile fracture has been analyzed using tests on round notched bar specimens and standard fracture mechanics tests performed at room temperature. In previous publications the damage model Gurson-Tvergaard-Needleman (GTN) has been applied and verified by existing experimental data to describe ductile fracture behavior. The brittle fracture and the fracture in temperature transition region have been studied by means of deep and shallow notched SENB specimens at two different temperatures T=- 80°C and -40°C. Besides elastic-plastic analyses to quantify constraint levels for different initial crack configurations at the onset of cleavage fracture, the brittle failure has been described using modified Beremin model. The influence of the stable crack growth on the cleavage failure probability in temperature transition region has been captured by coupling the ductile fracture model (GTN) with the modified Beremin model. Finally, examples have been presented for the practical application of the numerical results on the fracture assessment of the flawed high-strength pipelines.
This paper deals with a simulative approach for investigating the impact of inverter pulse inhibition during field weakening operation of permanent magnet synchronous machines and asynchronous induction machines. The modelling and simulation language Modelica is used to design models for the vehicle, the electric machine and the inverter in different abstraction levels. It is shown that when using a permanent magnet synchronous machine, a sudden breakdown of the field weakening current causes induction of high voltages in the stator windings. Hence, the electric system of the vehicle has to be protected against the resulting high currents. Furthermore precautions have to be taken to avoid dangerous driving conditions because of high braking torques in an inverter fault operation mode. In the case of the asynchronous induction machine an inverter pulse inhibition poses no big problem, neither for the electric system of the vehicle, nor the driver.
Condition monitoring of rotor problems such as demagnetization and eccentricity in permanent magnet synchronous motors (PMSM) is essential for guaranteeing high motor performance, efficiency, and reliability. However, there are many limitations to the off-line and on-line methods currently used for PMSM rotor quality assessment. In this paper, an inverter-embedded technique for automated detection and classification of PMSM rotor faults is proposed as an alternative. The main concept is to use the inverter to perform a test whenever the motor is stopped, to detect rotor faults independent of operating conditions or load torque oscillations, which is not possible with motor current signature analysis (MCSA). The d-axis is excited with a dc+ac signal, and the variation in the inductance pattern due to the change in the degree of magnetic saturation caused by demagnetization or eccentricity is observed for fault detection. An experimental study on a 7.5kW PMSM verifies that demagnetization and eccentricity can be detected and classified independent of the load with high sensitivity.
The majority of the work performed for detecting eccentricity faults for permanent magnet synchronous motors (PMSM) focus on motor current signature analysis (MCSA), as it provides continuous on-line monitoring with existing current sensors. However, MCSA cannot be applied under nonstationary conditions and cannot distinguish faults with load torque oscillations, which are limitations for many PMSM drive applications. In this paper, it is shown that the d-axis inductance, L d , decreases with increase in the severity of eccentricity due to the change in the degree of magnetic saturation, and it is proposed as a new fault indicator. The inverter can be used to perform a standstill test automatically whenever the motor is stopped, to measure L d for eccentricity testing independent of load variations or oscillations, which is not possible with MCSA. An FE and experimental study on a 10hp PMSM verifies that eccentricity can be detected independent of the load with high sensitivity and reliability.
The majority of industrial controlled induction machine drives are connected to the mains via a diode bridge. However; if reduction of harmonic currents and / or regenerative operation is desired; replacing the diode bridge by an active front-end (AFE) is required. This paper describes two models of an AFE: a power balance model disregarding switching effects; and an ideal switching model of a pulse width modulation (PWM) converter. Both models are controlled utilizing space phasors in a voltage oriented reference frame. Voltage oriented control (VOC) of the mains converter can be compared with field oriented control (FOC) of a machine converter. Design and parametrization of the main parts—synchronization with mains voltage; current controller and DC voltage controller—are described in detail. Additionally; simulation results proving the implementation and demonstrating possible investigations as well as an outlook on further enhancements are presented.