Energie und Mobilität
Refine
Year of publication
Document Type
- conference proceeding (article) (168)
- Article (143)
- Part of a Book (41)
- conference talk (32)
- Report (19)
- conference proceeding (presentation, abstract) (8)
- Book (7)
- Master's Thesis (4)
- Preprint (4)
- Part of Periodical (3)
Is part of the Bibliography
- no (431)
Keywords
- Energiewende (27)
- Erneuerbare Energien (27)
- Klimaneutralität (22)
- Power-to-Gas (21)
- Sektorenkopplung (16)
- Energiespeicher (14)
- Power-to-X (9)
- Wasserstoff (8)
- Netzplanung (7)
- Blindleistung (6)
Institute
- Fakultät Elektro- und Informationstechnik (240)
- Fakultät Maschinenbau (155)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (76)
- Combustion Engines and Emissions Control Laboratory (CEEC) (40)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energienetze (38)
- Labor Elektrische Maschinen und Antriebstechnik (37)
- Computational Mechanics and Materials Lab (CMM) (20)
- Technologie-Campus Neustadt an der Donau (20)
- Labor Intelligente Materialien und Strukturen (17)
- Fakultät Informatik und Mathematik (15)
Begutachtungsstatus
- peer-reviewed (187)
- begutachtet (15)
To identify the sound quality of fuel injection systems as a frontloading measure, a system test bench has been developed that simulates the structure and airborne noise emission. The setup of the system test bench includes an assembly of the acoustical relevant engine parts and an encapsulated drive for the high-pressure pump. A specific control unit enables a high variability for the operation strategy of the injection system.
The focus of this study is on the development of a methodology to analyze and optimize the sound quality of gasoline direct injectors in critical operation points by suitable active means. For this, the injection parameters in engine idle have been identified and subsequently transferred to the system test bench. Additionally, the injection parameters have been optimized acoustically and the impacts on the key functions regarding injection rating and shot-to-shot scattering of the injected fuel mass are discussed.
Due to the transition to renewable energy sources and the increasing share of electric vehicles and smart grids, batteries are gaining in importance. Battery management systems (BMSs) are required for optimal, reliable operation. In this paper, existing BMS topologies are presented and evaluated in terms of reliability, scalability and flexibility. The decentralisation of BMSs and associated advantages are shown. A scalable, reconfigurable BMS based on a distributed architecture of self-organized, locally controlled nodes is proposed. For distributed system control, producers, batteries and consumers each are equipped with a local microcontroller based control unit, which monitors and controls the local parameters with its own computing and communication resources. Features, advantages and challenges to overcome of the proposed approach are described.
Reliability of structures and infrastructures is a major issue in structural engineering. Structural standards have traditionally been mainly concerned with public safety preventing loss of life or injury; this view has been shifting in recent years towards minimisation of economic loss. This contribution discusses the reliability differentiation principle in modern standards. Its aim is to achieve uniform risk levels for the various classes of structures. Codified criteria for reliability differentiation and risk informed decisions inherent in standards and especially in the Eurocodes are critically reviewed. It is shown that the classification of structures based on consequences of failure is an approach that has not been widely implemented in everyday design. Practical rules for the classification and implementation in design are needed and related proposals are presented.
This paper decribes the concept of a course on control theory as a minor subject in the department of electrical engineering at the OTH Regensburg. The basis for a new concept is the idea of contructive alignment. The whole teaching module is devided in two blocks. The first block contains the teaching of the knowledge about control theory with an integrated approach for lectures, exercises and practical sessions. In the second block the students attent a practical work package to have the possibility to applicate and deepen their knowledge. To foster active participation the students are asked to document and reflect their work with the course context in an electronic portfolio. The exam of this module consists of three parts with respect to the different competencies obtained during the module. This concept develops not only the knowledge on control theory but personal and social competencies which are of growing interest. The aim of the paper is to present the idea of the concept. Following papers will illustrate the development process and the results obtained later on.
The reduction of the energy demand of existing buildings is the main objective of building refurbishment. Managing the heat radiation properties of the wall construction is a possible way to develop highly effective and resource efficient insulation materials and concepts. The application of infrared reflective wall paints and coatings has been studied since the latter half of the 20th century. A brief review of the literature gives an account of the current research status. One has to realise that the conclusions are not uniformly consistent but depend strongly on the specific boundary conditions and investigated parameters. The study presented here discusses the usage of infrared reflective wall paint in conjunction with heat insulation for historic brick masonry. The possible energy savings are linked to the resulting thermal comfort. We identify critical parameters that must be taken into account when using infrared reflective wall paint and derive recommended design rules for the refurbishment of such building types. The findings prove that infrared reflective wall paint can decrease heat losses by 18% and up to 22% if comfort conditions are considered. Increasing energy savings can also cause the negative effect of high radiative asymmetry. Thus, each configuration must be observed in detail.
Wind turbines play a crucial role in the revolution towards renewable resources. They need to be economically competitive to be sustainable. This still requires to lower the cost of energy (COE). To this end, nonlinear model predictive control (NMPC) is used within this paper. As known from literature, NMPC significantly improves the energy extracting performance as well as the mitigation of tower loads of wind turbines. As it is shown in this paper, the drivetrain fatigue strength drops disproportionally in parallel, which either increases the demands on the turbine design or decreases the lifetime of drivetrain components. Without additional boundary conditions to the underlying optimal control problems (OCPs), the application of energy-maximizing NMPC might so even raise the COE. Only penalizing axial torque oscillations by quadratic terms decreases energy-extracting performance below the level of classical wind turbine controllers. This makes more sophisticated conditions necessary. In this paper, the increase of the drivetrain damage by NMPC is analyzed, and appropriate boundary conditions are derived, to balance the two contradicting objectives of energy maximization and drivetrain load mitigation. An NMPC approach based on indirect methods is used, to obtain a solution of the OCPs very efficiently. It applies the Hamilton equations and Pontryagin's maximum principle. Its accuracy and efficiency to solve OCPs was presented over the last decades.
Im Rahmen des Projektes C/sells wurden mehrere Mittelspannungsnetze modelliert, um die aktuellen Spannungsverhältnisse und Leitungsauslastungen nachbilden zu können. Zudem wurden, angelehnt an den Netzentwicklungsplan, Szenarien für den zukünftigen PV-Zubau und die potenzielle Entwicklung der Elektromobilität entworfen. Auf Basis der Ergebnisse lässt sich eine Netzanalyse hinsichtlich Spannungs- und Stromgrenzwertüberschreitungen sowie zu deren potenziellen Auftrittszeitpunkten und Auftrittsdauern durchführen. Parallel wurde anhand von Sensitivitätsanalysen untersucht, welche Wirksamkeit Flexibilitätseinsätze an den verschiedenen Netzknoten auf den Engpass haben. Dadurch kann bestimmt werden, wie effektiv die verfügbaren, in der Regel örtlich gebundenen Flexibilitätsanbieter eingesetzt werden können. Da die Sensitivitäten arbeitspunktabhängig sind, wurden verschiedene Zeitpunkte im Jahresverlauf berechnet und die jeweilige Änderungen der Wirksamkeit ausgewertet. Neben der Höhe der Leistungsabweichung wurde die Flexibilitätsanforderung auch anhand der Einsatzzeitpunkte und Einsatzdauer sowie anhand der Häufigkeit der nötigen Flexibilitätseinsätze charakterisiert. Aus den gewonnenen Erkenntnissen soll abgeleitet werden, inwiefern sich der flexible Einsatz der Verbrauchsanlagen in der Netzplanung verankern lässt. Besonders relevant ist deshalb, mit welcher Verlässlichkeit die Flexibilität abgerufen werden kann. Eine sehr hohe Verlässlichkeit lässt sich je nach Flexibilitätsanbieter möglicherweise nicht oder nur zu sehr hohen Preisen gewährleisten. Die Eignung der Flexibilitätseinsätze wird somit sowohl aus technischer als auch aus wirtschaftlicher Sicht bewertet. Da eine vollständige Verlässlichkeit ohnehin nicht sichergestellt werden kann (technische Störungen einer Anlage, Wettereinflüsse, etc.), werden auch Fallback-Strategien, z. B. Einspeisespitzenkappung, in die Analyse einbezogen.
In Zusammenarbeit mit den Kreiswerken Cham wurde an der OTH Regensburg das Trinkwasserversorgungsgebiet mit allen relevanten Pumpen und Hochbehältern nachgebildet. Mithilfe des Modells kann die aktuelle, füllstandgesteuerte Betriebsweise unter Einhaltung der Randbedingungen (Grenzwerte der Behälterfüllstände, elektrische Verschaltung der Pumpen) simuliert werden. Daraus lässt sich auch das gesicherte, für die Netzplanung geeignete Flexibilitätspotenzial anhand der Leistungsabweichung gegenüber dem regulären Fahrplan, der Einsatzdauer, dem Einsatzzeitpunkt und der Pause zwischen den Flexibilitätsabrufen charakterisieren. In einem Feldversuch wurde vordergründig untersucht, inwiefern der Einsatz von Flexibilität in der Trinkwasserversorgung technisch umsetzbar ist.