Energie und Mobilität
Refine
Year of publication
Document Type
- conference proceeding (article) (168)
- Article (143)
- Part of a Book (41)
- conference talk (32)
- Report (19)
- conference proceeding (presentation, abstract) (8)
- Book (7)
- Master's Thesis (4)
- Preprint (4)
- Part of Periodical (3)
Is part of the Bibliography
- no (431)
Keywords
- Energiewende (27)
- Erneuerbare Energien (27)
- Klimaneutralität (22)
- Power-to-Gas (21)
- Sektorenkopplung (16)
- Energiespeicher (14)
- Power-to-X (9)
- Wasserstoff (8)
- Netzplanung (7)
- Blindleistung (6)
Institute
- Fakultät Elektro- und Informationstechnik (240)
- Fakultät Maschinenbau (155)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (76)
- Combustion Engines and Emissions Control Laboratory (CEEC) (40)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energienetze (38)
- Labor Elektrische Maschinen und Antriebstechnik (37)
- Computational Mechanics and Materials Lab (CMM) (20)
- Technologie-Campus Neustadt an der Donau (20)
- Labor Intelligente Materialien und Strukturen (17)
- Fakultät Informatik und Mathematik (15)
Begutachtungsstatus
- peer-reviewed (187)
- begutachtet (15)
Owing to increasingly stringent emission limits, particulate filters have become mandatory for gasoline-engine vehicles. Monitoring their soot loading is necessary for error-free operation. The state-of-the-art differential pressure sensors suffer from inaccuracies due to small amounts of stored soot combined with exhaust gas conditions that lead to partial regeneration. As an alternative approach, radio-frequency-based (RF) sensors can accurately measure the soot loading, even under these conditions, by detecting soot through its dielectric properties. However, they face a different challenge as their sensitivity may depend on the engine operation conditions during soot formation. In this article, this influence is evaluated in more detail. Various soot samples were generated on an engine test bench. Their dielectric properties were measured using the microwave cavity perturbation (MCP) method and compared with the corresponding sensitivity of the RF sensor determined on a lab test bench. Both showed similar behavior. The values for the soot samples themselves, however, differed significantly from each other. A way to correct for this cross-sensitivity was found in the influence of exhaust gas humidity on the RF sensor, which can be correlated with the engine load. By evaluating this influence during significant humidity changes, such as fuel cuts, it could be used to correct the influence of the engineon the RF sensor.
Friction has long been an important issue in multibody dynamics. Static friction models apply appropriate regularization techniques to convert the stick inequality and the non-smooth stick–slip transition of Coulomb’s approach into a continuous and smooth function of the sliding velocity. However, a regularized friction force is not able to maintain long-term stick. That is why dynamic friction models were developed in recent decades. The friction force depends herein not only on the sliding velocity but also on internal states. The probably best-known representative, the LuGre friction model, is based on a fictitious bristle but realizes a too-simple approximation. The recently published second-order dynamic friction model describes the dynamics of a fictitious bristle more accurately. It is based on a regularized friction force characteristic, which is continuous and smooth but can maintain long-term stick due to an appropriate shift in the regularization. Its performance is compared here to stick–slip friction models, developed and launched not long ago by commercial multibody software packages. The results obtained by a virtual friction test-bench and by a more practical festoon cable system are very promising. Thus, the second-order dynamic friction model may serve not only as an alternative to the LuGre model but also to commercial stick–slip models.
Dual front steering axles are quite common in multi-axled heavy duty trucks. In standard layouts of such axle combinations, the steer motions of the wheels depend not only on the rotation of the steering wheel but also on the movements of the axles. As a consequence, the model complexity of the steering system should match with the complexity of the suspension model. The development of new technologies like advanced driver assistance systems or autonomous driving can only be accomplished efficiently using extensive simulation methods. Such kind of applications demand for computationally efficient vehicle models. This paper presents a steering system model for dual front axles of heavy duty trucks which supplements the suspension model of the axles. The model takes the torsional compliance of the steering column as well as the stiffness of the tie rods and the coupling rod into account. A quasi-static solution provides a straight forward computation including the partial derivatives required for an efficient implicit solver. The steering system model matches perfectly with comparatively lean, but sufficiently accurate multibody suspension models.
Schlussbericht zum Verbundvorhaben NAMOSYN: Nachhaltige Mobilität durch synthetische Kraftstoffe
(2023)
Im Labor für Verbrennungsmotoren und Abgasnachbehandlung der OTH-Regensburg sollten im Zuge des NAMOSYN-Projektes zwei Vertreter klimaneutraler Kraftstoffe an verschiedenen Systemprüfständen (Motor-, Einspritzprüfstand, optisch zugängliche Einspritzkammer, …) und mit Hilfe von Simulationsmethoden für den Einsatz in bestehenden Verbrennungsmotoren untersucht werden. Synthetische Kraftstoffe aus der Gruppe der Oxymethylenether (OME) stellen eine CO2-neutrale Alternative zu fossilem Dieselkraftstoff dar. Für Ottomotoren wurde untersucht, ob der synthetische Kraftstoff DMC/MeFo (Dimethylcarbonat & Methylformiat) einen Ersatz für Ottokraftstoff darstellen kann, bzw. eine Drop-In-Fähigkeit gegeben ist.
Die OTH Regensburg bearbeitete 2 unabhängige Teilvorhaben zur motorischen Testung von synthetischen Kraftstoffen: „FC 1A: Motorische Testung von OME“ und „FC 2: Untersuchung von C1-Oxygenaten für Ottomotoren“. Die Projektlaufzeit betrug 3,5 Jahre, inkl. kostenneutraler Verlängerung um 6 Monate aufgrund der Corona-Pandemie.
Im FC1A "AP2-Nachrüstung Dieselmotoren" der OTH Regensburg lag der Fokus auf der Erforschung der Potentiale und der Umrüstung eines Einzylinder-Dieselmotors mit Pumpe-Leitung-Düse-(PLD)-Einspritzsystem des Projektpartners Motorenfabrik Hatz GmbH und Co. KG für OME-Betrieb.
Im AP2.1 wurden umfangreiche Daten gesammelt und Simulationsmodelle des Motors und PLD-Einspritzsystems erstellt und mit Dieselkraftstoff und OME validiert. Nachfolgend wurden Parameterstudien zur Geometrie des Einspritzsystems und der physikalischen Eigenschaften von OME durchgeführt.
In AP2.2 und AP2.3 wurden umfangreiche Untersuchungen an einem Motor- und Einspritzsystemprüfstand mit Diesel und OME durchgeführt und der Steuergerätedatensatz für den OME-Betrieb optimiert.
Die Ergebnisse zeigen, dass die Umstellung des Kraftstoffs auf OME, insbesondere bei einfachen Motoren mit rudimentärer Einspritztechnik und ohne Mittel zur NOx-Reduzierung (keine AGR oder SCR), ein enormes Potenzial zur Steigerung des Wirkungsgrads bei gleichzeitiger Reduzierung aller regulierten Schadstoffe (NOx, 𝑃N, 𝑃M, CO und 𝑉OC) eröffnet. Die Ergebnisse und generierten Simulationsmodelle unterstützen eine schnelle Serienentwicklung und Einführung von OME-Umrüstlösungen.
In FC 2 werden die vielversprechenden Kraftstoffe Methylformiat (MeFo) und Dimethylcarbonat (DMC) motorisch getestet. Untersuchungen am Kraftstoffsystem und wichtigen Komponenten dienen als Grundlage für das AP3.
Im AP3 wird die Machbarkeit der DMC/MeFo-Verbrennung am Vollmotor demonstriert und die erwarteten Emissionsvorteile gegenüber herkömmlichen Ottokraftstoffen gezeigt. Abweichend von der ursprünglichen Planung werden an der OTH Regensburg Kraftstoffblends aus Benzin und MeFo untersucht, um den Einsatzbereich des Kraftstoffs zu erweitern.
In AP5 werden potentielle Mischungsverhältnisse analysiert und die Eigenschaften der ausgewählten Kraftstoffmischungen an einem Einspritzratenprüfstand, an der Einspritzkammer und am Vollmotor untersucht. Es werden Einspritzverhalten, Gemischaufbereitung und Abgasemissionen bewertet.
Zudem wird eine Kraftstoffmischanlage entwickelt und ein optischer Zugang am Vollmotor ermöglicht. Eine Ölverdünnungsmesstechnik wird eingesetzt, um den Kraftstoffeintrag ins Motoröl zu untersuchen
Energieforschung
(2023)
Über uns
Das Regensburg Center of Energy and Resources (RCER) bündelt seit 2012 die Aktivitäten der Ostbayerischen Technischen Hochschule Regensburg (OTH Regensburg) und der regionalen Wirtschaftsunternehmen auf dem Strategiefeld „Energie und Ressourcen“.
Mission: Energieforschung: vernetzen, voranbringen, vermitteln
Das RCER fördert die Vernetzung verschiedener Disziplinen der Energieforschung innerhalb der OTH Regensburg und mit externen Partnern (Firmen, Förderträgern, Forschungsinstitutionen, öffentlichen Einrichtungen). Das RCER ist Ihr Partner beim Voranbringen von Kooperationen und Forschungsvorhaben durch Unterstützung in der Antragsphase, bei der Einwerbung von Projektmitteln und Projektbegleitung im Energiebereich. Das RCER steht für die Vermittlung von Know-how, Basiswissen, aktuellen Fragen und den Technologietransfer rund um das Thema Energie zwischen Wissenschaft, Wirtschaft, Gesellschaft und Politik.
Vision
Wir sind Ihr erster Ansprechpartner und Motor für innovative Energieforschung.
Werte
Verlässlichkeit, Kompetenz, Verantwortungsbewusstsein.Regional verwurzelt und weltoffen
The effect of both heat and mass transfer characteristic lengths (HTCL, MTCL) of two different adsorber plate heat exchangers (APHE), for application in an adsorption chiller, on the adsorption and desorption kinetics is investigated. Three representative test frames (TF1-TF3) are prepared to examine small-scale adsorbent samples of the microporous silica gel (Siogel of Oker-Chemie, Germany) applying the volumetric large-temperature-jump methodology at different operating conditions. Based on the obtained kinetic data, an analytical model has been developed to predict the specific cooling power (SCP) and the coefficient of performance (COP) of a single-bed adsorption chiller comprising the studied APHEs. It turned out that, within the tested range of HTCL and MTCL, it can be concluded that, the adsorption kinetics are mainly influenced by the MTCL, while the desorption kinetics are dominated by the HTCL of the adsorbent domain. Applying Siogel as loose pellets inside a newly introduced APHE results in of 423.3 and 182.7 W⋅kg−1, at the evaporator temperatures of 15 °C and 5 °C, respectively. Herein, the condenser and adsorber-end temperatures amount to 30 °C and the desorption-end temperature to 90 °C. The corresponding s amount to 0.50 and 0.40, respectively, which represent quite promising results for further design optimizations.
Acoustic emission (AE) testing recently found its application in the wafer testing sector of the semiconductor industry. To find out the mechanical robustness of semiconductor devices, contact pads on the chip surface are intentionally overstressed with an indenter tip and the appearing oxide cracks are detected with help of the generated AE signals. This is done in a customized test bench with a patented sensor-indenter system. This paper presents an improved version of the measurement setup that solves certain disadvantages of it and can be used in a standard wafer prober. The main components of the developed sensor system are a strain gauge for contact force measurement and a piezoelectric sensor element for AE signal detection. Both components are integrated on a cantilever beam which has an exchangeable indenter tip at its free end. The cantilever probe is electrically conductive to enable electrical tests via the indenter tip. This smart sensor-cantilever combination (SCC) can be mounted with several adapter components on a carrier plate to place it in a wafer prober. For both sensor elements amplifier circuits are developed to enhance their signal-to-noise ratios (SNRs). A prototype setup is shown together with simulated and experimental results to demonstrate its performance. The mechanical properties of the cantilever, as well as the force sensor and the AE crack signals, already fulfill the requirements for an implementation in a wafer prober. To further improve the sensor resolutions and detection limits, several optimizations regarding the design of the SCC are in progress.
Green hydrogen via renewable powered electrolysis has a high relevance in decarbonization and supply security. Achieving economically competitive hydrogen production costs is a major challenge in times of an energy price crisis. Our objective is to show the economically optimal installed capacity of electrolysers in relation to wind and solar power so swift and credible statements can be made regarding the system design. The ratio between renewable generation and electrolysis power as well as scaling effects, operating behaviour and development of costs are considered. Hydrogen production costs are calculated for four exemplary real PV and wind sites and different ratios of electrolysis to renewable power for the year 2020. The ideal ratio for PV systems is between 14% and 73% and for wind between 3.3% and 143% for low and high full load hours. The lowest hydrogen production costs are identified at 2.53 €/kg for 50 MW wind power and 72 MW electrolysis power. The results provide plant constructors the possibility to create a cost-optimized design via an optimum ratio of electrolysis to renewable capacity. Therefore, the procedures for planning and dimensioning of selected systems can be drastically simplified.
This communication presents an experimental and analytical study on the evaporation mechanism in a closed-structured asymmetric plate heat exchanger (PHE) employed as a stagnant water evaporator for the application in an adsorption heat transformation appliance. To this aim, an experimental unit is constructed, which comprises two identical PHEs, one acting as an vaporator/condenser and the second, as an adsorber/desorber. Two endoscopes are mounted inside the investigated evaporator to visualize the evaporation mechanism when performing adsorption-evaporation processes under different boundary conditions. It turned out that the evaporation mechanism is a partially covered, thin film evaporation. A heat transfer analysis is performed to evaluate the heat transfer coefficient of the thin film evaporation () inside the investigated evaporator, resulting in -values between 1330 and 160 [W∙m−2∙K−1] over the investigated adsorption-evaporation time. Correlating the obtained () to the film thickness and the wetted area results in -values between 0.34 and 0.78 [mm] and wetted to total area ratios of 0.78 to 0.16. Besides, an analytical model has been developed and introduced to correlate the overall evaporator heat transfer coefficient with the adsorption potential and the time rate of change of the water uptake.
Appropriate climate change mitigation requires solutions for all actors of the energy system. The residential sector is a major part of the energy system and solutions for the implementation of a seasonal hydrogen storage system in residential houses has been increasingly discussed. A global analysis of prosumer systems including seasonal hydrogen storage with water electrolyser, hydrogen compressor, storage tank, and a fuel cell studying the role of such a seasonal household storage in the upcoming decades is not available. This study aims to close this research gap via the improved LUT-PROSUME model, which models a fully micro sector coupled residential photovoltaic prosumer system with linear optimisation for 145 regions globally. The modelling of the cost development of hydrogen storage components allows for the simulation of a residential system from 2020 until 2050 in 5-year steps in hourly resolution. The systems are cost-optimised for either on- or off-grid operation in eight scenarios including battery electric vehicles, which can act as an additional vehicle-to-home electricity storage for the system. Results show that implementation of seasonal hydrogen systems only occurs in least cost solutions in high latitude countries when the system is forced to run in off-grid mode. In general, a solar photovoltaic plus battery system including technologies that can cover the heat demand is the most economic choice and can even achieve lower cost than a full grid supply in off-grid operation for most regions until 2050. Additional parameters including the self-consumption ratio, the demand cover ratio, and the heat cover ratio can therefore not be improved by seasonal storage systems if economics is the main deciding factor for a respective system. Further research opportunities and possible limitations of the system are then identified.
Over the past decade, cars have turned gradually into real cyber physical systems. The collaboration of services between the service-oriented, cross-enterprise vehicle application frameworks has increased to generate novel, smart and complicated vehicle services. Consequently, from an interoperability perspective, semantically mapping of vehicle service component’s interface ontological models emerged as a big research interest in automotive application domain that manipulates several cross-enterprise synergy knowledge applications frameworks. The ontological metamodeling lays the foundation for building semantic bridge and exploring semantic associations between service components’ interface models based on the domain knowledge for semantic interoperability. Also, several semantic quality metrics has been defined over time for the vehicle service interface ontological metamodels. The empirically evaluated values of these metrics can be used to assess progress in cross-enterprise interoperability between the service and the clients’ APIs ontological models in vehicle domain. Despite potential benefits of semantic alignment quality metrics, the effective use of these metrics for vehicle service interface ontologies have proven elusive. Yes, such metrics can be used successfully for quantification, but then they mostly fail to provide adequate annotations in subsequent decision-making in the direction of semantic interoperability and reusability. The effective use of ontology semantic alignment quality metrics is basically hindered in the absence of the meaningful thresholds. In fact, the absence of an effective and meaningful threshold for the semantic similarity measure between various vehicle service interface ontological metamodels, motivates this research work which not only proposes a design approach to an optimized threshold for the semantic similarity metrics but also applies this threshold on few defined semantic alignment quality metrics. This paper also uses a real-world vehicle domain industrial case study to illustrate the design approach.
Hydrogen storage based on the repeated reduction and oxidation (redox) reactions of iron oxide/iron composites represents a promising technology. This work is dedicated to studying the influence of the amount of water added during the pelletizing process on the cycle stability and structure of iron oxide pellets. The storage composites were prepared from iron oxide (Fe2O3) and 10 wt.-% support material (cement) with different amounts of water (18 and 33 wt.-%) in a laboratory-scale pelletizing disk. To evaluate the cycle stability of the composites, the kinetics of the redox reactions were experimentally measured at 800 ∘
C in an atmosphere of 50% N2 and 50% H2 (reduction) or 50% steam (oxidation), respectively. Moreover, the structure of the pellets was analyzed by micro-computed tomography scans. It turned out that pellets with higher water contents attained faster kinetics and a higher cycle stability. The sample with the least water content (18 wt.-%) needed about 26 min and 19 min to reach a conversion rate of 80% during the reduction and oxidation reactions of the sixth redox cycle, respectively. In contrast, the sample with the highest water content (33 wt.-%) could achieve the same conversion rate after 18 min (reduction) and 13 min (oxidation) during the ninth redox cycle.
Increasingly stringent emission limits have made particulate filters necessary for gasoline engines. Similar to diesel applications, gasoline particulate filters (GPFs) can be monitored by differential pressure measurement or by the radio-frequency-based filter diagnosis (RF sensor). In addition to measuring the soot loading, ash detection is critical for monitoring the GPF over the entire vehicle lifetime. Because the RF sensor detects the filter loading through a change in the dielectric properties of the GPF, it can detect not only soot but also ash. In diesel applications, the RF sensor has already demonstrated its potential for ash detection. To verify the feasibility of simultaneous ash and soot monitoring for GPFs, filters were loaded with ash on an engine test bench and measured on a lab test bench under defined synthetic exhaust gas conditions. By evaluating resonant modes, soot and ash could be clearly distinguished, as ash mainly affects the resonant frequency, while soot also changes the quality factor due to its high dielectric losses. However, higher soot loadings could not be detected by the resonant parameters, but instead by a frequency-averaged transmission signal. While the presence of ash caused an offset in this signal, its sensitivity to soot was not affected. Thus, the influence of ash can be corrected if the signal in the soot-free filter state is known, e.g., from the behavior of the resonant parameters. Therefore, even with a continuously increasing ash loading over the lifetime of a vehicle, an accurate soot detection is possible with the RF sensor.
Dieser Bericht entstand auf Initiative der Studierenden des Masterstudiengangs „Elektro- und Informationstechnik (MEI)“, die an der Pflichtlehrveranstaltung „Forschungsmethoden und Seminar (FMS)“ im Wintersemester 2022/23 teilnahmen.
Diese Lehrveranstaltung hat das Ziel, systematisch an das wissenschaftliche Arbeiten, speziell die Wissenschaftskommunikation, heranzuführen.
Daher war geeignete Literatur zu einem individuellen Thema zu recherchieren, Veröffentlichungen auf ihre Relevanz hin zu beurteilen und letztendlich eine eigene Ausarbeitung basierend auf der Literaturrecherche zu erarbeiten und diese in einem Vortrag zu präsentieren.
Parallel dazu erfolgte im Theorieteil die entsprechende Hinführung zu den
verschiedenen Elementen der Wissenschaftskommunikation:
• Bedeutung der Wissenschaftskommunikation für die Arbeit der Ingenieure
in Forschung und Entwicklung
• Literaturrecherche, Suchmaschinen, Sichtung und Analyse vorhandener
Publikationen, Bewertung der Qualität aufgefundener Fachliteratur,
Auswahl geeigneter Materialien für die eigene Arbeit
• Aufbereitung und Darstellung der recherchierten technischer Inhalte
in Form einer seitenanzahlbegrenzten wissenschaftlichen Ausarbeitung
• Einhalten formaler Randbedingungen bzgl. Strukturierung, einschl.
Bildnachweise und Zitationsstile
• Peer-review-Prozess bei wertschätzender Beurteilung der Leistung
anderer
• Publikumsangepasstes Aufbereiten komplexer fachlicher Inhalte mit
hochschulöffentlicher Präsentation der Ergebnisse
• Führen mündlicher wissenschaftlicher Diskurse Nachdem die Masterstudierenden in der Regel über noch keine eigene wissenschaftliche Forschungserfahrung bzw. -inhalte verfügen, lag der
wählbare Schwerpunkt der Literatursuche auf der Bearbeitung von vorgegeben aktuellen technischen oder gesellschaftspolitischen Forschungsthemen.
In this study, a pilot-scale trickle-bed reactor for biological methanation and various scale-up scenarios for 2023 and 2050 were investigated using LCA. A best- and worst-case scenario for technology development until 2050 was evolved using cross consistency analysis and morphological field, based on which the data for the ecological models were determined.The results show that the plant scale-up has a very positive effect on the ecological consequences of methanation. In the best-case scenario, the values are a factor of 23-780 lower than those of the actual plant today. A hot-spot analysis showed that especially electrolysis operation has a large impact on total emissions. The final Monte-Carlo simulation shows that the technology is likely to achieve a low GWP with a median of 104.0 kg CO2-eq / MWh CH4.
Im Rahmen der vier Kopernikus-Projekte – Ariadne, ENSURE, P2X und SynErgie – wird die Transformation des deutschen Energiesystems hin zur Klimaneutralität analysiert. Im vorliegenden Bericht werden hierbei robuste Kernaussagen und relevante Unsicherheiten derjenigen Szenarien der Kopernikus-Schwesterprojekte dargestellt, die zur Zielsetzung die Klimaneutralität 2045 haben. Hierbei liegt der Fokus auf Indikatoren, die eine besonders hohe klimapolitische Relevanz haben.
Im Projekt MAGGIE wurden für das genossenschaftliche historische Stadtquartier „Margaretenau“ in Regensburg Musterlösungen für energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht.
Dazu wurde ein bestehendes Wohngebäude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus Wärmepumpentechnologie und Kraft- Wärme-Kopplung ausgestattet und untersucht, ergänzt durch eine dynamische Wärmelogistik zur Verringerung von Verteilungsverlusten.
Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems während des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Strombörse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltwärme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Gebäudebetrieb.
Für die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realität getestet. Am Bestandsgebäude kam anstelle eines Wärmedämmverbundsystems ein innovativer Dämmputz mit Mikrohohlglaskugeln zum Einsatz.
Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles über mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete für die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erhöht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird.
Industrial plants can provide reactive power (Q) for system- and grid-serving behavior, for which a functioning reactive power management system is essential. To make reactive power retrieval as efficient and safe as possible, the selection of reactive power sources to meet the Q-demand must consider their sensitivities and the restrictions of the industrial grid, such as operating equipment utilization or voltage limits. On this basis, a concept for a sensitivity-based control strategy that manages the reactive power retrieval of multiple reactive power sources depending on a predefined reactive power demand value is proposed. Based on the simulation of an industrial plant in the medium-voltage grid, which can provide reactive power in the form of industrial compensation systems (ICS) and generators, the operation of the algorithm is shown.
Im Projekt MAGGIE wurden für das genossenschaftliche historische Stadtquartier „Margaretenau“ in Regensburg Musterlösungen für energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht.
Dazu wurde ein bestehendes Wohngebäude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus Wärmepumpentechnologie und Kraft- Wärme-Kopplung ausgestattet und untersucht, ergänzt durch eine dynamische Wärmelogistik zur Verringerung von Verteilungsverlusten.
Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems während des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Strombörse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltwärme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Gebäudebetrieb.
Für die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realität getestet. Am Bestandsgebäude kam anstelle eines Wärmedämmverbundsystems ein innovativer Dämmputz mit Mikrohohlglaskugeln zum Einsatz.
Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles über mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete für die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erhöht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird.
A magnetic levitation system is a perfect educational example of a nonlinear unstable system. Only with suitable control, a small permanent magnet can be held floating stable below a coil. After modeling and simulation of the system, control of the system can be developed. At the end, the control algorithm can be coded on a microcontroller, connected to a pilot plant.