Energie und Mobilität
Refine
Document Type
- conference proceeding (article) (15)
- Article (6)
- Part of a Book (5)
Language
- English (26)
Has Fulltext
- no (26)
Is part of the Bibliography
- no (26)
Keywords
Institute
Begutachtungsstatus
- peer-reviewed (15)
An electric traction machine for an electric or a hybrid electric vehicle is usually designed for a specific operating point or cycle. For such an operating point or cycle, the masses and the cooling circuit of the electric machine determine the time dependent temperature distribution within the machine. For a specific load cycle, the thermal simulation of the machine can reveal possible mass and size reductions for a given insulation class of the machine. In addition, such simulations allow the comparison of various cooling concepts. In the machine design process, the first step is a conventional electromagnetic machine design. From the geometric data of this design and the material properties, the parameters of a thermal equivalent circuit can be derived. The differential and algebraic equations of the thermal equivalent circuit are solved by a simulation tool to predict the temperatures of the critical parts in the electric machine. A thermal equivalent circuit is accurate enough to predict the thermal behavior of the critical parts in the electric machine, and yet not too complex, to obtain simulation results with moderate numerical effort. This enables an iterative design process to optimize the drive.
This paper proposes a multi domain physical model of permanent magnet synchronous machines, considering electrical, magnetic, thermal and mechanical effects. For each component of the model, the main wave as well as lower and higher harmonic wave components of the magnetic flux and the magnetic potential difference may be considered. The permanent magnets are modeled as discrete azimuthal segments in order to consider possible partial demagnetization effects. For each magnet segment a linearized temperature dependent B-H curve is considered. The main advantage of the presented model is that time transient operational behavior of a permanent magnet synchronous machine can be considered under various electrical, magnetic, thermal and mechanical conditions. The electromagnetic condition of surface magnet machine is compared with finite element analysis.
This paper focuses on simulation of permanent magnet synchronous machine (PMSM) with fractional-slot windings (FSW) in Modelica. Modeling of the electrical machines with object-oriented approach is shortly described, and a new Modelica library for simulation of electrical machines is introduced. The results of simulation of PMSMs with fractional slot windings are presented and explained. Special attention is paid to the higher harmonics and subharmonics produced by the winding and their influence on machine operation.
Condition monitoring of rotor problems such as demagnetization and eccentricity in permanent magnet synchronous motors (PMSM) is essential for guaranteeing high motor performance, efficiency, and reliability. However, there are many limitations to the off-line and on-line methods currently used for PMSM rotor quality assessment. In this paper, an inverter-embedded technique for automated detection and classification of PMSM rotor faults is proposed as an alternative. The main concept is to use the inverter to perform a test whenever the motor is stopped, to detect rotor faults independent of operating conditions or load torque oscillations, which is not possible with motor current signature analysis (MCSA). The d-axis is excited with a dc+ac signal, and the variation in the inductance pattern due to the change in the degree of magnetic saturation caused by demagnetization or eccentricity is observed for fault detection. An experimental study on a 7.5kW PMSM verifies that demagnetization and eccentricity can be detected and classified independent of the load with high sensitivity.
Simulation is an indispensable tool for the engineering of systems containing electric drives. Depending on the design phase and the engineering task different levels of modeling details are required: proof of concept; investigation of energy and power consumption; design of control; etc. The new EDrives library provides three levels of abstraction for inverters: quasi static (neglecting electrical transients); averaging (neglecting switching effects) and switching – for serving different demands. The inverters can feed the machine models of the Modelica Standard Library: Modelica.Magnetic.FundamentalWave and the new Modelica.Magnetic.QuasiStatic.FundamentalWave. The EDrives library copes with arbitrary phase numbers and can be easily extended to develop new control algorithms. In this publication the structure of the library and the implemented control principles are presented. Furthermore; examples comparing the three different levels of abstraction are included.
The majority of industrial controlled induction machine drives are connected to the mains via a diode bridge. However; if reduction of harmonic currents and / or regenerative operation is desired; replacing the diode bridge by an active front-end (AFE) is required. This paper describes two models of an AFE: a power balance model disregarding switching effects; and an ideal switching model of a pulse width modulation (PWM) converter. Both models are controlled utilizing space phasors in a voltage oriented reference frame. Voltage oriented control (VOC) of the mains converter can be compared with field oriented control (FOC) of a machine converter. Design and parametrization of the main parts—synchronization with mains voltage; current controller and DC voltage controller—are described in detail. Additionally; simulation results proving the implementation and demonstrating possible investigations as well as an outlook on further enhancements are presented.
Sensorless PM-Drive Aspects
(2010)
The development procedure of permanent magnet drives for sensor less operation beginning from standstill under overload conditions has to consider different design aspects coevally. First, the robust rotor position sensing by test signal enforces a design with a strongly different behavior of the spatial dq-oriented differential inductance values. Therefore, the interior rotor magnet array arrangement is from principle predestinated for the controlled sensor less mode including standstill. Fortunately, in order to reduce costs, the distinct reluctance torque capability of such interior magnet arrangement is additionally used for a significantly increased torque by applying a pre-oriented stator current space vectors within the quasi-steady control.
Two state-of-the-art machine designs are mainly used in recent electric and hybrid electric vehicles: asynchronous induction machines with squirrel cage which are robust but need a current component to excite the magnetic field; and permanent magnet synchronous machines which rely on somehow more sensible parts but the magnets are able to excite a magnetic field without current. However; if speed gets high enough to reach the field weakening range; for both machine the field oriented control has to prescribe a field current sufficient to reduce the field not to exceed the voltage limits of the stator circuit. Especially for the permanent magnet synchronous machine this paper investigates whether it is possible to determine an optimal field current for every operation point to minimize either total current consumption or losses.
This paper presents a comprehensive computational fluid (CFD) model of a radial flux permanent magnet synchronous machine with interior magnets. In the CFD model the water jacket cooling and a simplified model of the topology of the distributed stator winding are considered. The heat sources of the CFD model are determined from a finite element analysis of the machine. The numerically determined temperature distributions of the machine are compared with measurement results from sensors located both in the stator and rotor. The particular focus of this paper is the analysis of the temperatures and the heat flow in the air gap and from the stator winding head and the rotor to the inner air.