Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium
Refine
Year of publication
Document Type
Language
- English (221) (remove)
Is part of the Bibliography
- no (221)
Keywords
- Humans (7)
- magnetoactive elastomer (6)
- Power-to-Gas (5)
- COVID-19 (4)
- magnetoelectric effect (4)
- magnetorheological elastomer (4)
- magnetostriction (4)
- Barrett's esophagus (3)
- Deformation (3)
- Germany (3)
Institute
- Fakultät Maschinenbau (67)
- Fakultät Informatik und Mathematik (65)
- Fakultät Elektro- und Informationstechnik (46)
- Regensburg Center of Biomedical Engineering - RCBE (29)
- Labor Intelligente Materialien und Strukturen (23)
- Fakultät Angewandte Natur- und Kulturwissenschaften (17)
- Regensburg Medical Image Computing (ReMIC) (14)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (13)
- Labor Biomechanik (LBM) (10)
- Fakultät Betriebswirtschaft (9)
Begutachtungsstatus
- peer-reviewed (194)
In the early-stage development of sheet metal parts, key design properties of new structures must be specified. As these decisions are made under significant uncertainty regarding drawing configuration changes, they sometimes result in the development of new parts that, at a later design stage, will not be drawable. As a result, there is a need to increase the certainty of experience-driven drawing configuration decisions.
Complementing this process with a global sensitivity analysis can provide insight into the impact of various changes in drawing configurations on drawability, unveiling cost-effective strategies to ensure the drawability of new parts. However, when quantitative global sensitivity approaches, such as Sobol's method, are utilized, the computational requirements for obtaining Sobol indices can become prohibitive even for small application problems. To circumvent computational limitations, we evaluate the applicability of different surrogate models engaged in computing global design variable sensitivities for the drawability assessment of a deep-drawn component.
Here, we show in an exemplary application problem, that both a standard kriging model and an ensemble model can provide commendable results at a fraction of the computational cost. Moreover, we compare our surrogate models to existing approaches in the field. Furthermore, we show that the error introduced by the surrogate models is of the same order of magnitude as that from the choice of drawability measure. In consequence, our surrogate models can improve the cost-effective development of a component in the early design phase.
An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone
(2024)
n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.
Small and medium-sized enterprises (SMEs) increasingly need to manage nformation technology (IT) effectively in order to remain competitive. However, compared to larger organizations, SMEs often face challenges in terms of resources and employer attractiveness, and regularly do not have the need to employ a Chief Information Officer (CIO) on a full-time basis. To address this issue, a growing number of global experts have begun to provide CIO services on a part-time basis for multiple clients simultaneously. This approach allows SMEs to tap into the expertise of experienced IT leaders at a fraction of the cost and without committing to long-term arrangements. While these professionals, known as “Fractional CIOs”, have proven their value in the field, there has been a lack of academic research on this emerging trend. Therefore, we carried out a comprehensive research project between 2020 and 2023, involving 62 Fractional CIOs from 10 countries. The research produced a definition, different types of engagements, and success factors for Fractional CIOs and their engagements. This paper summarizes these findings for a wider audience of academics and practitioners.
Significant deformations of bodies made from compliant magnetoactive elastomers (MAE) in magnetic fields make these materials promising for applications in magnetically controlled actuators for soft robotics. Reported experimental research in this context was devoted to the behaviour in the quasi-static magnetic field, but the transient dynamics are of great practical importance. This paper presents an experimental study of the transient response of apparent longitudinal and transverse strains of a family of isotropic and anisotropic MAE cylinders with six different aspect ratios in time-varying uniform magnetic fields. The time dependence of the magnetic field has a trapezoidal form, where the rate of both legs is varied between 52 and 757 kA/(s·m) and the maximum magnetic field takes three values between 153 and 505 kA/m. It is proposed to introduce four characteristic times: two for the delay of the transient response during increasing and decreasing magnetic field, as well as two for rise and fall times. To facilitate the comparison between different magnetic field rates, these characteristic times are further normalized on the rise time of the magnetic field ramp. The dependence of the normalized characteristic times on the aspect ratio, the magnetic field slew rate, maximum magnetic field values, initial internal structure (isotropic versus anisotropic specimens) and weight fraction of the soft-magnetic filler are obtained and discussed in detail. The normalized magnetostrictive hysteresis loop is introduced, and used to explain why the normalized delay times vary with changing experimental parameters.
Utility of Smartphone-based Three-dimensional Surface Imaging for Digital Facial Anthropometry
(2024)
Background
The utilization of three-dimensional (3D) surface imaging for facial anthropometry is a significant asset for patients undergoing maxillofacial surgery. Notably, there have been recent advancements in smartphone technology that enable 3D surface imaging.
In this study, anthropometric assessments of the face were performed using a smartphone and a sophisticated 3D surface imaging system.
Methods
30 healthy volunteers (15 females and 15 males) were included in the study. An iPhone 14 Pro (Apple Inc., USA) using the application 3D Scanner App (Laan Consulting Corp., USA) and the Vectra M5 (Canfield Scientific, USA) were employed to create 3D surface models. For each participant, 19 anthropometric measurements were conducted on the 3D surface models. Subsequently, the anthropometric measurements generated by the two approaches were compared. The statistical techniques employed included the paired t-test, paired Wilcoxon signed-rank test, Bland–Altman analysis, and calculation of the intraclass correlation coefficient (ICC).
Results
All measurements showed excellent agreement between smartphone-based and Vectra M5-based measurements (ICC between 0.85 and 0.97). Statistical analysis revealed no statistically significant differences in the central tendencies for 17 of the 19 linear measurements. Despite the excellent agreement found, Bland–Altman analysis revealed that the 95% limits of agreement between the two methods exceeded ±3 mm for the majority of measurements.
Conclusion
Digital facial anthropometry using smartphones can serve as a valuable supplementary tool for surgeons, enhancing their communication with patients. However, the proposed data suggest that digital facial anthropometry using smartphones may not yet be suitable for certain diagnostic purposes that require high accuracy.
The 0-1 multidimensional knapsack problem (MKP) is a well-known combinatorial optimization problem with several real-life applications, for example, in project selection. Genetic algorithms (GA) are effective heuristics for solving the 0-1 MKP. Multiple individual GAs with specific characteristics have been proposed in literature. However, so far, these approaches have only been partially compared in multiple studies with unequal conditions. Therefore, to identify the “best” genetic algorithm, this article reviews and compares 11 existing GAs. The authors' tests provide detailed information on the GAs themselves as well as their performance. The authors validated fitness values and required computation times in varying problem types and environments. Results demonstrate the superiority of one GA.
In a three-guide coupler with multimode central waveguide, more than two modes of the entire structure participate in the coupling between the outer waveguides. Using a three-mode approximation we found simple conditions for complete power transfer between the outer waveguides: the device length has to match certain multiples of the con- ventionally defined coupling length. The specific form of the relevant modes allows us to design a magneto-optic isolator or circulator with significantly reduced device length (as compared to the conventional nonreciprocal coupler). The performance of the proposed devices is simulated by propagating-mode calculations. Estimates for admissible fabrication tolerances for the layer thicknesses are presented.
Following a ban on many materials containing bisphenol-A, new bisphenol-free Boron silicates have been found as substitutes. The purpose of this study is to describe the mechanical properties of these bisphenol-free magnetoactive borosilicate polymers containing hard magnetic particles. Samples of 0%, 33% and 66% by wt. were loaded for compression using a universal testing machine. The maximum forces occurring for different travel speeds were compared before and after post-magnetization treatments. The post-magnetization included 2 stages. In addition, the change in mechanical properties within 24 hours after the post-magnetization process was investigated. Furthermore, the influence of speed and particle content were investigated. In general, there is a correlation between the required compressive force and, the level of post-magnetization stress, the increase in travel speed and particle content in the boron silicate. Comparison of the non-post-magnetized and post-magnetized samples using two-tailed t-tests shows that the p-values for all weight fraction changes in NdPrFeB particles and travel speeds are less than 0.001. Also, a comparison between tests in which the traverse speed was varied also showed significant changes in the resulting compression forces. The same is valid for changes in the weight ratio of the NdPrFeB particles in the samples. For post-magnetized samples, no significant difference can be observed in the first 24 hours following magnetization. In summary, the material presents viscoelastic, plastic force-displacement behavior, which can be well recognized by its bi-linear curve shape.
The investigation shows that borosilicate polymers based on NdPrFeB can have their mechanical behavior modified and controlled by post-magnetization processes. This opens new possibilities for many future applications.
Field emitter arrays (FEAs) are a promising component for novel vacuum micro- and nanoelectronic devices, such as microwave power amplifiers or fast-switching X-ray sources. However, the interrelated mechanisms responsible for FEA degradation and failure are not fully understood. Therefore, we present a measurement method for quantitative observation of individual emission sites during integral operation using a low-cost, commercially available CMOS imaging sensor. The emission and degradation behavior of three differently doped FEAs is investigated in current-regulated operation. The measurements reveal that the limited current of the p-doped emitters leads to an activation of up to 55% of the individual tips in the array, while the activation of the n-type FEA stopped at around 30%. This enhanced activation results in a more continuous and uniform current distribution for the p-type FEA. An analysis of the individual emitter characteristics before and after a constant current measurement provides novel perspectives on degradation behavior. A burn-in process that trims the emitting tips to an integral current-specific ideal field enhancement factor is observed. In this process, blunt tips are sharpened while sharp tips are dulled, resulting in homogenization within the FEA. The methodology is described in detail, making it easily adaptable for other groups to apply in the further development of promising FEAs.