Regensburg Center of Biomedical Engineering - RCBE
Refine
Year of publication
Document Type
- Article (92)
- conference proceeding (article) (92)
- conference talk (37)
- conference proceeding (presentation, abstract) (33)
- Part of a Book (4)
- conference proceeding (volume) (3)
- Doctoral Thesis (2)
- Moving Images (2)
- Other (2)
- Preprint (1)
Is part of the Bibliography
- no (269)
Keywords
- Simulation (11)
- Biomechanik (9)
- Deep Learning (9)
- Biomechanics (8)
- Bildverarbeitung (7)
- Hüftgelenkprothese (7)
- Lernprogramm (7)
- Bildgebendes Verfahren (6)
- Biomechanische Analyse (6)
- Handchirurgie (6)
- Stent (6)
- Maschinelles Lernen (5)
- Operationstechnik (5)
- Osteosynthese (5)
- 3D-Druck (4)
- AnyBody (4)
- Bewegungsapparat (4)
- Computerunterstützte Medizin (4)
- Computerunterstütztes Verfahren (4)
- Datenschutz (4)
- Diagnose (4)
- Medizin (4)
- Speiseröhrenkrankheit (4)
- Automatische Klassifikation (3)
- Bildanalyse (3)
- Bildsegmentierung (3)
- Computertomographie (3)
- Deformation (3)
- Dreidimensionale Bildverarbeitung (3)
- ECMO (3)
- Gait analysis (3)
- MRI (3)
- Magnetic Resonance Imaging (3)
- Medical Image Computing (3)
- Musculoskeletal simulation (3)
- Schultergelenk (3)
- THA (3)
- biomechanics (3)
- Adenocarcinoma (2)
- Aerosols (2)
- Anomalie (2)
- AnyBody Modeling System (2)
- Ballondilatation (2)
- Bilderkennung (2)
- Blood Viscosity (2)
- Breast imaging (2)
- Brustkorb (2)
- CFD (2)
- Catheters (2)
- Combined anteversion (2)
- Convolutional neural networks (2)
- Coronary stenting (2)
- Datensicherung (2)
- Digital anthropometry (2)
- Dual-material 3D printing (2)
- Endoscopy (2)
- Endoskopie (2)
- Finite element analysis (2)
- Finite-Elemente-Methode (2)
- Flow visualisation (2)
- HaptiVisT (2)
- Image processing (2)
- Implantation (2)
- Inverse dynamics (2)
- Kernspintomografie (2)
- Künstliche Intelligenz (2)
- Literaturbericht (2)
- Lumbar spine (2)
- Mechanische Belastung (2)
- Membrane Oxygenator (2)
- Musculoskeletal Modeling (2)
- Mustererkennung (2)
- Nasal airflow (2)
- Non-rigid surface registration (2)
- Numerische Strömungssimulation (2)
- Polymers (2)
- Stiffness (2)
- Stress (2)
- Surgical outcome simulation (2)
- Tomographic PIV (2)
- Ultrastruktur (2)
- Viscoelasticity (2)
- Visualisierung (2)
- Zilie (2)
- musculoskeletal simulation (2)
- 3D analysis (1)
- 3D breast scan registration (1)
- 3D surface imaging (1)
- 4FC (1)
- ANTERIOR CINGULATE CORTEX (1)
- ASIS (1)
- Abduction tasks (1)
- Accoucheur (1)
- Adaptive clinical trial (1)
- Adhesives (1)
- Aerodynamics (1)
- Aerosole (1)
- Alloplastik (1)
- Animals (1)
- Anisotropy (1)
- Antiangiogenese (1)
- Antiangiogenic treatment (1)
- Arbeitsbedingungen (1)
- Arterial biomechanics (1)
- Arthrodese (1)
- Artificial Intelligence (1)
- Artificial intelligence (1)
- Arztpraxis (1)
- Autogene Transplantation (1)
- Autologous bone graft (1)
- BLOOD FLOW (1)
- Barrett (1)
- Barrett's esophagus (1)
- Barrett's esphagus (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Belastung (1)
- Beweglichkeit (1)
- Bewegung (1)
- Bewegungsanalyse (1)
- Bioactivity (1)
- Biological models (1)
- Biologische Modelle (1)
- Biomarker (1)
- Biomaterial (1)
- Biomechanical investigation (1)
- Biopsy (1)
- Bone harvesting (1)
- Bone imaging (1)
- Brain Segmentation (1)
- Breast reconstruction (1)
- Breast reconstruction surgery (1)
- Breast symmetry (1)
- Breathing cycle (1)
- Brustwirbelsäule (1)
- CELT (1)
- CHONDROCYTE DEATH (1)
- CONNECTIVITY (1)
- COVID-19 (1)
- Catheter (1)
- Chest X-Ray (1)
- Cochlea-Implantat (1)
- Computer aided diagnosis and therapy (1)
- Computer-aided diagnosis (1)
- Computer-assisted surgery (1)
- Computerassistierte Chirurgie (1)
- Computersimulation (1)
- Constitutive modeling (1)
- Conventional surgery (1)
- Coronary (1)
- Coronary artery (1)
- Corrosion rate (1)
- Covid-19 (1)
- Crimping (1)
- Cup medialisation (1)
- Damage mechanism (1)
- Deep learning (1)
- Deep learning fluid mechanics (1)
- Dental membrane (1)
- Depression (1)
- Deutschland (1)
- Dielectric properties (1)
- Dragonfly (1)
- Dragonfly wing (1)
- ECMO SYSTEMS (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Electrical components (1)
- Electrical properties and parameters (1)
- Electrical resistivity (1)
- Electromyography (1)
- Electron microscopy (1)
- Elektromyographie (1)
- Elite athletes (1)
- Ellenbogenstabilität (1)
- Encoder-Decoder Network (1)
- Endotracheal Intubation (1)
- Equipment Failure Analysis/statistics & numerical data (1)
- Ergonomics (1)
- Ex vivo porcine stent model (1)
- Extracorporeal Membrane Oxygenation/instrumentation (1)
- FEA (1)
- FRONTAL-CORTEX (1)
- Facial anthropometry (1)
- Farbenraum (1)
- Fatigue fracture (1)
- Felsenbein (1)
- Femur first (1)
- Finite element (1)
- Flow (1)
- Fluid Mechanics (1)
- Football (1)
- Force-feedback haptic (1)
- Fräsen (1)
- Funktionelle Anatomie (1)
- Gait (1)
- Gamification in der Medizin (1)
- Gefäßverletzung (1)
- Gehen (1)
- Gehirn (1)
- General Purpose Graphic Processing Unit (1)
- Germany (1)
- Gesundheitswesen (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Gliding Flight (1)
- Gliom (1)
- Graustufe (1)
- Ground Reaction Force Prediction (1)
- HUMAN ARTICULAR-CARTILAGE (1)
- Haltungsfehler (1)
- Hand surgery training (1)
- Haptische Feedback-Technologie (1)
- Haptisches Feedback (1)
- Head trauma (1)
- Heat treatment (1)
- Hemodynamics (1)
- High-grade glioma (1)
- Hochschuldidaktik (1)
- Hüftgelenkpfanne (1)
- IMU (1)
- INFLAMMATION (1)
- Iliac crest (1)
- Image analysis (1)
- Image classification (1)
- Image segmentation (1)
- Implantat (1)
- Implantatwerkstoff (1)
- Indentation test (1)
- Inertial Measurement Units (1)
- Injury score (1)
- Internal fixator (1)
- Joint Reaction Forces (1)
- K-wire drilling (1)
- Kardiovaskuläres System (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenentnahme (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Koronare Herzkrankheit (1)
- Koronarendoprothese (1)
- Krankheitsverlauf (1)
- Körper (1)
- Körperliche Belastung (1)
- Lasers (1)
- Leg length (1)
- Leistungssportler (1)
- Ligament stiffness (1)
- MDCT (1)
- MONOPOLAR (1)
- MULTIDETECTOR COMPUTED-TOMOGRAPHY (1)
- Machine Learning (1)
- Machine learning (1)
- Magnesium (1)
- Magnetic fluids (1)
- Magnetic materials (1)
- Mammoplastik (1)
- Maschinelles Sehen (1)
- Material properties (1)
- Materialprüfung (1)
- Mechanical properties (1)
- Mechanical testing (1)
- Medical training system (1)
- Medizinische Versorgung (1)
- Medizinisches Trainingssystem (1)
- Mehrkörpersimulation (1)
- Membrane/classification/standards/statistics & numerical data (1)
- Mensch (1)
- Metamaterial (1)
- Micro-structure (1)
- Minimal-invasive Chirurgie (1)
- Minimalinvasive Handchirurgie (1)
- Minimally invasive hand surgery (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Movement (1)
- Multibody Simulation (1)
- Multimodal response assessment (1)
- Multiphase blood flow (1)
- Muscle (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscoloskeletal model (1)
- Musculoskeletal (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskuloskelettale Simulation (1)
- Nachweis (1)
- Neuronales Netz (1)
- Non Newtonian fluids (1)
- Non-Newtonian multiphase flow (1)
- Numerische Methode (1)
- OXYGENATION (1)
- Objekterkennung (1)
- Offset (1)
- Optimierung (1)
- Outcome (1)
- PCR (1)
- PET (1)
- PLATELET ACTIVATION (1)
- PREDICTOR (1)
- Pandemie (1)
- Parallel Execution (1)
- Parallelverarbeitung (1)
- Parameter study (1)
- Pattern recognition (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Percutaneous coronary intervention (1)
- Personenbezogene Daten (1)
- Physiological Breathing (1)
- Polymer (1)
- Polymerase-Kettenreaktion (1)
- Powders (1)
- Primary Health Care/statistics & numerical data (1)
- Prognose (1)
- RTMS (1)
- Randomized (1)
- Rapamycin (1)
- Rapid prototyping (1)
- Resilience, psychological (1)
- Resilienz, psychologische (1)
- Respiratory Distress Syndrome/therapy (1)
- Restenosis (1)
- Retrospective Studies (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- SARS-CoV-2 (1)
- SLAC wrist (1)
- SNAC wrist (1)
- STIMULATION (1)
- Sagittal balance (1)
- Schulkind (1)
- Schädel-Hirn-Trauma (1)
- Second-harmonic generation imaging (1)
- Segmentation (1)
- Segmentierung (1)
- Semi-automated segmentation (1)
- Senile Makuladegeneration (1)
- Severity of Illness Index (1)
- Shear Raed Induced Coagulation (1)
- Shear Rate Induced Coagulation (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Silent Breathing (1)
- Smartphone-based surface imaging (1)
- Softening (1)
- Specimen preparation and treatment (1)
- Speedcourt (1)
- Speiseröhrenkrebs (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Spongiosa (1)
- Stabilität (1)
- Statistical shape mode (1)
- Statistical shape model (1)
- Steifigkeit (1)
- Stent design (1)
- Stent implantation (1)
- Stent screening (1)
- Stents (1)
- Stereophotogrammetry (1)
- Support material (1)
- Surface treatments (1)
- Surgical smoke (1)
- THERMAL CHONDROPLASTY (1)
- THR (1)
- THROMBOSIS (1)
- THROMBOTIC DEPOSITS (1)
- TMS (1)
- Telemedizin (1)
- Thoracolumbar spine (1)
- Three-dimensional surface imaging (1)
- Time factors (1)
- Tissue-imitating hand phantom (1)
- Torus (1)
- Total hip athroplasty (1)
- Tracheotomies (1)
- Uniaxial – biaxial tension (1)
- Vascular Malformations (1)
- Vascular injury (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vernetzung (1)
- Vertebra (1)
- Violinspiel (1)
- Virtual Reality (1)
- Virtual fixtures (1)
- Virtual reality (1)
- Virtualisierung (1)
- Virtuelle Realität (1)
- Virtuelles Training (1)
- Voxel Spacing (1)
- Webcast (1)
- Windows 10 (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- Zielverfolgung (1)
- aerodynamics (1)
- anti-Inflammatory agent (1)
- attention (1)
- blood (1)
- cell- free DNA (1)
- cell-enriched lipotransfer (1)
- chemical synthesis (1)
- children (1)
- chondrocytes (1)
- coagulation (1)
- combined anteversion (1)
- component position (1)
- computational fluid dynamics (1)
- computer-assisted orthopaedic surgery (1)
- crosstalk (1)
- digital anthropometry (1)
- drug-eluting stent (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- energy (1)
- esb (1)
- fat grafting (1)
- femoral offset (1)
- flexibility ellipsis (1)
- form-finding (1)
- gait analysis (1)
- gargle (1)
- gliding flight (1)
- hand (1)
- hand surgery training (1)
- happiness (1)
- high-impact exercisess (1)
- hip contact force (1)
- histological evaluation (1)
- human articular cartilage (1)
- humeroradial stability (1)
- hydrogels (1)
- inertial measurement units (1)
- infiltration (1)
- inflammation (1)
- insect flight (1)
- inverse dynamics (1)
- kinematics (1)
- lipoaspirate (1)
- lipograft (1)
- lower back load (1)
- mechanical compliance (1)
- membrane lung (1)
- metamaterial (1)
- moment arm (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- neutrophil extracellular traps (1)
- optical motion capture (1)
- osteoarthritis (1)
- osteoporosis (1)
- pandemic (1)
- pelvic tilt (1)
- pharmacology (1)
- pooling (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rapamycin (1)
- reconstructive surgery (1)
- rheological model (1)
- sadness (1)
- schools (1)
- shear induced clotting (1)
- shoulder elevation (1)
- shoulder joint force (1)
- sirolimus (1)
- stem cells (1)
- stent platform (1)
- subluxation (1)
- surface electromyography (1)
- surgery (1)
- tensegrity joint (1)
- therapeutic use (1)
- tissue imitating phantom hand (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- total hip replacement (1)
- toxicity (1)
- tracheobronchial mucus (1)
- vWF (1)
- validation (1)
- violin (1)
- viscoelasticity (1)
- von Willebrand factor (1)
- wearable motion-tracking sensors (1)
- white adipose tissue (1)
- zwitterionic monomers (1)
- µCT (1)
Institute
- Regensburg Center of Biomedical Engineering - RCBE (269)
- Fakultät Maschinenbau (215)
- Labor Biomechanik (LBM) (134)
- Fakultät Informatik und Mathematik (50)
- Regensburg Medical Image Computing (ReMIC) (43)
- Regensburg Center of Health Sciences and Technology - RCHST (42)
- Labor Innovation & Regulatory Affairs (IRA) (33)
- Labor Biofluidmechanik (27)
- Labor Medizinprodukte (17)
- Labor eHealth (eH) (4)
Begutachtungsstatus
- peer-reviewed (98)
- begutachtet (10)
Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics
(2024)
BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research.
METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems.
RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements.
CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models.
Pelvic floor dysfunction is a common problem in women and has a negative impact on their quality of life. The aim of this review was to provide a general overview of the current state of technology used to assess pelvic floor functionality. It also provides literature research of the physiological and anatomical factors that correlate with pelvic floor health. This systematic review was conducted according to the PRISMA guidelines. The PubMed, ScienceDirect, Cochrane Library, and IEEE databases were searched for publications on sensor technology for the assessment of pelvic floor functionality. Anatomical and physiological parameters were identified through a manual search. In the systematic review, 114 publications were included. Twelve different sensor technologies were identified. Information on the obtained parameters, sensor position, test activities, and subject characteristics was prepared in tabular form from each publication. A total of 16 anatomical and physiological parameters influencing pelvic floor health were identified in 17 published studies and ranked for their statistical significance. Taken together, this review could serve as a basis for the development of novel sensors which could allow for quantifiable prevention and diagnosis, as well as particularized documentation of rehabilitation processes related to pelvic floor dysfunctions.
Extracorporeal membrane oxygenation (ECMO) was established as a treatment for severe cardiac or respiratory disease. Intra-device clot formation is a common risk. This is based on complex coagulation phenomena which are not yet sufficiently understood. The objective was the development and validation of a methodology to capture the key properties of clots deposed in membrane lungs (MLs), such as clot size, distribution, burden, and composition. One end-oftherapy PLS ML was examined. Clot detection was performed using multidetector computed tomography (MDCT), microcomputed tomography (μCT), and photography of fiber mats (fiber mat imaging, FMI). Histological staining was conducted for von Willebrand factor (vWF), platelets (CD42b, CD62P), fibrin, and nucleated cells (4′, 6-diamidino-2-phenylindole, DAPI). The three imaging
methods showed similar clot distribution inside the ML. Independent of the imaging method, clot loading was detected predominantly in the inlet chamber of the ML. The μCT had the highest accuracy. However, it was more expensive and time consuming than MDCT or FMI. The MDCT detected the clots with low scanning time. Due to its lower resolution, it only showed clotted areas but not
the exact shape of clot structures. FMI represented the simplest variant, requiring little effort and resources. FMI allowed clot localization and calculation of clot volume. Histological evaluation indicated omnipresent immunological deposits throughout the ML. Visually clot-free areas were covered with leukocytes and platelets forming platelet-leukocyte aggregates (PLAs). Cells were embedded in vWF cobwebs, while vWF fibers were negligible. In conclusion, the presented
methodology allowed adequate clot identification and histological classification
of possible thrombosis markers such as PLAs.
The recent REACH regulations require the elimination of bisphenol-A and titanium dioxide from commercially available boron-based polymers. This has led to changes in some of the mechanical characteristics, which strongly influence the properties of magnetoactive borosilicate polymers. This work delivers results on the electrical properties and discusses some implications for future research using bisphenol-A and titanium-dioxide-free substitutes.
Seit mehr als 25 Jahren ist der Workshop "Bildverarbeitung für die Medizin" als erfolgreiche Veranstaltung etabliert. Ziel ist auch 2024 wieder die Darstellung aktueller Forschungsergebnisse und die Vertiefung der Gespräche zwischen Wissenschaftlern, Industrie und Anwendern. Die Beiträge dieses Bandes - viele davon in englischer Sprache - umfassen alle Bereiche der medizinischen Bildverarbeitung, insbesondere die Bildgebung und -akquisition, Segmentierung und Analyse, Visualisierung und Animation, computerunterstützte Diagnose sowie bildgestützte Therapieplanung und Therapie. Hierbei kommen Methoden des maschinelles Lernens, der biomechanischen Modellierung sowie der Validierung und Qualitätssicherung zum Einsatz.
The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes.
Utility of Smartphone-based Three-dimensional Surface Imaging for Digital Facial Anthropometry
(2024)
Background
The utilization of three-dimensional (3D) surface imaging for facial anthropometry is a significant asset for patients undergoing maxillofacial surgery. Notably, there have been recent advancements in smartphone technology that enable 3D surface imaging.
In this study, anthropometric assessments of the face were performed using a smartphone and a sophisticated 3D surface imaging system.
Methods
30 healthy volunteers (15 females and 15 males) were included in the study. An iPhone 14 Pro (Apple Inc., USA) using the application 3D Scanner App (Laan Consulting Corp., USA) and the Vectra M5 (Canfield Scientific, USA) were employed to create 3D surface models. For each participant, 19 anthropometric measurements were conducted on the 3D surface models. Subsequently, the anthropometric measurements generated by the two approaches were compared. The statistical techniques employed included the paired t-test, paired Wilcoxon signed-rank test, Bland–Altman analysis, and calculation of the intraclass correlation coefficient (ICC).
Results
All measurements showed excellent agreement between smartphone-based and Vectra M5-based measurements (ICC between 0.85 and 0.97). Statistical analysis revealed no statistically significant differences in the central tendencies for 17 of the 19 linear measurements. Despite the excellent agreement found, Bland–Altman analysis revealed that the 95% limits of agreement between the two methods exceeded ±3 mm for the majority of measurements.
Conclusion
Digital facial anthropometry using smartphones can serve as a valuable supplementary tool for surgeons, enhancing their communication with patients. However, the proposed data suggest that digital facial anthropometry using smartphones may not yet be suitable for certain diagnostic purposes that require high accuracy.
Early motion therapy plays an important role for effective long-term healing of joint injuries. In many cases, conventional dynamic orthoses fail to address the intricate movement possibilities of the underlying joints, limited by their simplistic joint representations, often represented by revolute joints, enabling rotations by only one axis. In this paper, a two-dimensional compliant tensegrity joint for use in biomedical applications is investigated. It consists of two compressed members and five compliant tensioned members. Relative movement possibilities are realized by the intrinsic compliance of the structure. In the development of these systems, the first step is the determination of the static stable equilibrium. This analysis is conducted in this paper by considering the potential energy approach or by using the geometric nonlinear finite element method. The mechanical behavior of the structure is assessed with a specific emphasis on its mechanical compliance. The primary objective of this study is the investigation of the influence of structural parameters on the overall stiffness and movability of the structure. The results underscore the significant effect of member parameters on the stiffness and movability of the compliant tensegrity joint, particularly under varying load magnitudes. These findings provide insights for optimizing the joint’s performance, contributing to its potential application in advanced orthotic and exoskeleton devices.
BACKGROUND: Thrombosis remains a critical complication during venovenous extracorporeal membrane oxygenation (VV ECMO). The involvement of neutrophil extracellular traps (NETs) in thrombogenesis has to be discussed. The aim was to verify NETs in the form of cell-free DNA (cfDNA) in the plasma of patients during ECMO.
METHODS: A fluorescent DNA-binding dye (QuantifFluor®, Promega) was used to detect cell-free DNA in plasma samples. cfDNA concentrations from volunteers (n = 21) and patients (n = 9) were compared and correlated with clinical/technical data before/during support, ECMO end and time of a system exchange.
RESULTS: Before ECMO, patients with a median (IQR) age of 59 (51/63) years, SOFA score of 11 (10/15), and ECMO run time of 9.0 (7.0/19.5) days presented significantly higher levels of cfDNA compared to volunteers (6.4 (5.8/7.9) ng/μL vs. 5.9 (5.4/6.3) ng/μL; p = 0.044). Within 2 days after ECMO start, cfDNA, inflammatory, and hemolysis parameters remained unchanged, while platelets decreased (p = 0.005). After ECMO removal at the end of therapy, cfDNA, inflammation, and coagulation data (except antithrombin III) remained unchanged. The renewal of a system resulted in known alterations in fibrinogen, d-dimers, and platelets, while cfDNA remained unchanged.
CONCLUSION: Detection of cfDNA in plasma of ECMO patients was not an indicator of acute and circuit-induced thrombogenesis.
Aufgrund der steigenden Lebenserwartung und dem damit einhergehenden demographischen Wandel wird der Bedarf an Rehabilitations-Behandlungen in absehbarer Zukunft stark ansteigen. Ein Beispiel für diesen Trend ist die physiotherapeutische Behandlung nach Erhalt einer Knie-Totalendoprothese (Knie-TEP). So gehen Modellrechnungen basierend auf dem Bevölkerungswachstum und der bisherigen Prävalenz von Knie-TEPs davon aus, dass die Anzahl an durchgeführten Eingriffen in einkommensstarken Ländern wie Deutschland weiter zunehmen wird. Weiterhin stoßen traditionelle Rehabilitationsverfahren, gerade in strukturschwachen Regionen, schon heute an ihre Grenzen. Deutlich zu sehen war das während den Hochphasen der aktuellen Covid-19-Pandemie, als der Kontakt zwischen Therapeut*in und Patient*in flächendeckend eingeschränkt war. Eine erhöhte Nachfrage nach neuartigen Reha-Angeboten ist die logische Konsequenz. Innovative Konzepte sind daher dringend notwendig, um die daraus resultierenden technischen, sozialen und ökonomischen Herausforderungen zu bewältigen.
BACKGROUND:
Tracheobronchial mucus plays a crucial role in pulmonary function by providing protection against inhaled pathogens. Due to its composition of water, mucins, and other biomolecules, it has a complex viscoelastic rheological behavior. This interplay of both viscous and elastic properties has not been fully described yet. In this study, we characterize the rheology of human mucus using oscillatory and transient tests. Based on the transient tests, we describe the material behavior of mucus under stress and strain loading by mathematical models.
METHODS:
Mucus samples were collected from clinically used endotracheal tubes. For rheological characterization, oscillatory amplitude-sweep and frequency-sweep tests, and transient creep-recovery and stress-relaxation tests were performed. The results of the transient test were approximated using the Burgers model, the Weibull distribution, and the six-element Maxwell model. The three-dimensional microstructure of the tracheobronchial mucus was visualized using scanning electron microscope imaging.
RESULTS:
Amplitude-sweep tests showed storage moduli ranging from 0.1 Pa to 10000 Pa and a median critical strain of 4 %. In frequency-sweep tests, storage and loss moduli increased with frequency, with the median of the storage modulus ranging from 10 Pa to 30 Pa, and the median of the loss modulus from 5 Pa to 14 Pa. The Burgers model approximates the viscoelastic behavior of tracheobronchial mucus during a constant load of stress appropriately (R2 of 0.99), and the Weibull distribution is suitable to predict the recovery of the sample after the removal of this stress (R2 of 0.99). The approximation of the stress-relaxation test data by a six-element Maxwell model shows a larger fit error (R2 of 0.91).
CONCLUSIONS:
This study provides a detailed description of all process steps of characterizing the rheology of tracheobronchial mucus, including sample collection, microstructure visualization, and rheological investigation. Based on this characterization, we provide mathematical models of the rheological behavior of tracheobronchial mucus. These can now be used to simulate mucus flow in the respiratory system through numerical approaches.
Für Fußballer:innen stellen muskuläre Verletzungen der unteren Extremitäten ein großes Problem dar. Ein Beispiel hierfür liefert die Nationalmannschaftsstürmerin Alexandra Popp, die aufgrund muskulärer Probleme das EM-Finale 2022 in Wembley kurzfristig verpasste. Oftmals stehen gerade hohe Anspannungssituationen in zeitlichem Zusammenhang mit Verletzungen, der Einfluss der psychischen Beanspruchung auf die biomechanischen Belastungen wird jedoch meist nur wenig beachtet.
To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments.
In Vitro Analysis of Human Cartilage Infiltrated by Hydrogels and Hydrogel-Encapsulated Chondrocytes
(2023)
Osteoarthritis (OA) is a degenerative joint disease causing loss of articular cartilage and structural damage in all joint tissues. Given the limited regenerative capacity of articular cartilage, methods to support the native structural properties of articular cartilage are highly anticipated. The aim of this study was to infiltrate zwitterionic monomer solutions into human OA-cartilage explants to replace lost proteoglycans. The study included polymerization and deposition of methacryloyloxyethyl-phosphorylcholine- and a novel sulfobetaine-methacrylate-based monomer solution within ex vivo human OA-cartilage explants and the encapsulation of isolated chondrocytes within hydrogels and the corresponding effects on chondrocyte viability. The results demonstrated that zwitterionic cartilage–hydrogel networks are formed by infiltration. In general, cytotoxic effects of the monomer solutions were observed, as was a time-dependent infiltration behavior into the tissue accompanied by increasing cell death and penetration depth. The successful deposition of zwitterionic hydrogels within OA cartilage identifies the infiltration method as a potential future therapeutic option for the repair/replacement of OA-cartilage extracellular suprastructure. Due to the toxic effects of the monomer solutions, the focus should be on sealing the OA-cartilage surface, instead of complete infiltration. An alternative treatment option for focal cartilage defects could be the usage of monomer solutions, especially the novel generated sulfobetaine-methacrylate-based monomer solution, as bionic for cell-based 3D bioprintable hydrogels.
Seit mehr als 25 Jahren ist der Workshop "Bildverarbeitung für die Medizin" als erfolgreiche Veranstaltung etabliert. Ziel ist auch 2023 wieder die Darstellung aktueller Forschungsergebnisse und die Vertiefung der Gespräche zwischen Wissenschaftlern, Industrie und Anwendern. Die Beiträge dieses Bandes - viele davon in englischer Sprache - umfassen alle Bereiche der medizinischen Bildverarbeitung, insbesondere die Bildgebung und -akquisition, Segmentierung und Analyse, Visualisierung und Animation, computerunterstützte Diagnose sowie bildgestützte Therapieplanung und Therapie. Hierbei kommen Methoden des maschinelles Lernens, der biomechanischen Modellierung sowie der Validierung und Qualitätssicherung zum Einsatz.
We investigate contrastive learning in a multi-task learning setting classifying and segmenting early Barrett’s cancer. How can contrastive learning be applied in a domain with few classes and low inter-class and inter-sample variance, potentially enabling image retrieval or image attribution? We introduce a data sampling strategy that mines per-lesion data for positive samples and keeps a queue of the recent projections as negative samples. We propose a masking strategy for the NT-Xent loss that keeps the negative set pure and removes samples from the same lesion. We show cohesion and uniqueness improvements of the proposed method in feature space. The introduction of the auxiliary objective does not affect the performance but adds the ability to indicate similarity between lesions. Therefore, the approach could enable downstream auto-documentation tasks on homogeneous medical image data.
Surgical Smoke is generated during the cauterization of tissue with high-frequency (HF) devices and consists of 95% water vapor and 5% cellular debris. When the coagulation tweezers, which are supplied with HF voltage by the HF device, touch tissue, the electric circuit is closed, and smoke is generated by the heat. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during coagulation of tissue. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. With higher power of the HF device, the particles generated are larger in size and the total number of particles generated is also higher. Adding artificial saliva to the tissue shows even higher particle counts. The study by laser light sheet also confirms this. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms considering the risk arising from surgical smoke. Furthermore, the experiments will provide the database for further numerical investigations.
High Spatial Resolution Tomo-PIV of the Trachea Focussing on the Physiological Breathing Cycle
(2023)
Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions.
This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person’s head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras‘ double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field.
Introduction
Shear induced multimerisation of von-Willebrand-factor (vWF) is supposed to play an important role in coagulation inside extracorporeal membrane oxygenators. However, there is no proof that links observed vWF structures to computed or measured flow conditions.
Methods
The structures of multimeric vWF fibers, observed in clinically used membrane oxygenators is examined using immunofluorescence microscopy (IFM) using Carstairs’ staining method (positive ethics committee vote). The flow around the membrane fibres inside the oxygenator is investigated in terms of shear rate, wall shear velocity and streamlines by using CFD (RANS, Carreau-Yasuda viscosity, geometry remodelled after high-resolution µCT-scans). By interpreting the histological and numerical results in this common context, indications for shear induced coagulation mechanisms can be identified.
Results
The fibre structures of multimeric vWF build regular but not exactly symmetric formations around the contact face (CF) between the crosswise stacked oxygenator fibres (OF), see fig.1B, vWF marked red. Annular around the CF arranged, cells are likely to be found, see fig.1B, nuclei marked blue.
The computed streamlines around the OF show attached flow around the circular fibres. However, the irregular arrangement of real OF produce considerable cross flow between the interconnected neighbouring channels, in contrast to previous 2D-simulations. Thus, the CF are washed around closely by blood, also from neighbouring channels. The wall shear velocity streamlines form regular, slightly asymmetric shapes around the contact faces. The occurring maximum shear rates are in the range of 1,000 1/s.
Discussion
The shapes of vWF structures found in clinically used oxygenators match the computational results in terms of wall shear velocity and streamlines well. The accumulation of cells close to the CF can also be explained by fluid mechanics, as there are small shear gradients and slow velocities. However, occurring shear rates between OFs are too low to trigger multimerisation of vWF. That raises the question where in the circuit the actual activation of vWF is started and how, at least partly chained, vWF multimeres are attracted towards the OF surface. A next step will be the investigation of the actual shear rate triggered (or mediated) multimerisation of vWF. Towards this end, microfluidic experiments with shear triggered coagulation will be performed. Also of big interest is the computation of the flow situation in the oxygenator in proximity to chaining threads, which have been ignored in computations so far. However, first a realistic representation of the effective viscosity in computations is needed, which is not available yet.
Für Mutter und Kind konnte das Risiko der Geburt durch die Weiterentwicklung der Medizin drastisch reduziert werden. Doch wie ist es um das Wohl derer bestellt, die die Gebärende unterstützen? Eine Studie der Ostbayerischen Technischen Hochschule Regensburg hat sich mit den muskuloskelettalen Beschwerden von Geburtshelfer:innen auseinandergesetzt
Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83–0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20–0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs.
Influence of CFD Strategy on WSS and OSI Determination for Intracranial Aneurysm Rupture Assessment
(2019)
Feasibility of detecting thrombotic deposits in membrane oxygenators using micro computed tomography
(2019)
Coagulative disorders, especially clotting during extracorporeal membrane oxygenation, are frequent complications. Direct visualization and analysis of deposits in membrane oxygenators using computed tomography (CT) may provide an insight into the underlying mechanisms causing thrombotic events. However, the already established multidetector CT1 (MDCT) method shows major limitations. Here, we demonstrate the feasibility of applying industrial micro-CT (μCT) to circumvent these restrictions. Three clinically used membrane oxygenators were investigated applying both MDCT and μCT.
The scans were analyzed in terms of clot volume and local clot distribution. As validation, the clot volume was also determined from the fluid volume, which could be filled into the respective used oxygenator compared to a new device. In addition, cross-sectional CT images were compared with crosscut oxygenators. Based on the μCT findings, a morphological measure (sphericity) for assessing clot structures in membrane oxygenators is introduced. Furthermore, by comparing MDCT and μCT results, an augmentation of the MDCT method is proposed, which allows for improved clot volume determination in a clinical setting.
Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots—in particular, the presence of von Willebrand factor (vWF)—may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti‐vWF and anti‐P‐selectin) and counterstained with 4′,6‐diamidino‐2‐phenylindole. The extent of vWF‐loading was correlated with patient and technical data. While 12 MOs showed low vWF‐loadings, 9 MOs showed high vWF‐loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF‐fibers/“cobwebs,” leukocytes, platelet–leukocyte aggregates (PLAs), and P‐selectin‐positive platelet aggregates were independent of the extent of vWF‐loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high‐molecular‐weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy.
The special wing geometry of dragonflies consisting of veins and a membrane forming a corrugated profile leads to special aerodynamic characteristics. To capture the governing flow regimes of a dragonfly wing in detail, a realistic wing model has to be investigated. Therefore, this study aimed to analyze the aerodynamic characteristics of a 3D dragonfly wing reconstructed from a high-resolution micro-CT scan. Afterwards, a spatially high discretized mesh was generated using the mesh generator CENTAUR™ 14.5.0.2 (CentaurSoft, Austin, TX, US) to finally conduct Computational Fluid Dynamics (CFD) investigations in Fluent® 2020 R2 (ANSYS, Inc., Canonsburg, PA, US). Due to the small dimensions of the wing membrane, only the vein structure of a Camacinia Gigantea was captured at a micro-CT voxel size of 7 microns. The membrane was adapted and connected to the vein structure using a Boolean union operation. Occurring nconsistencies after combining the veins and the membrane were corrected using an adapted pymesh script [1]. As an initial study, only one quarter of the wing (outer wing section) was investigated to reduce the required computational effort. The resulting hybrid mesh consisting of 10 pseudo-structured prism layers along the wing surface and tetrahedra in the farfield area has 43 mio. nodes. The flow around the wing was considered to be incompressible and laminar using transient calculations. When the flow passes the vein structures, steady vortices occur in the corrugation valleys leading to recirculation zones. Therefore, the dragonfly wing resembles the profile of an airfoil. This leads to comparable lift coefficients of dragonfly wings and airfoil profiles at significantly reduced structural weight. The reconstructed geometry also included naturally occurring triangular prismlike serrated structures at the leading edge of the wing, which have comparable effects to micro vortex generators and might stabilize the recirculation zones. Further work aims to investigate the aerodynamic properties of a complete dragonfly wing during wing flapping.
Air leakage past High-Volume-Low-Pressure (HVLP) endotracheal tube (ETT) cuffs creates a potential infection risk for health care professionals during ventilation of patients suffering from contagious airborne diseases. However, unlike silent aspiration, a phenomenon where fluids enter the airways of intubated patients, the aspect of aerosol emergence through cuff folds -what we called accordingly “silent breathing” (SB)- has not been investigated in detail so far.
This study investigates air leakage past HVLP cuffs with varying cuff pressures under realistic artificial breathing scenarios experimentally and in addition numerically. The focus was laid on the parametric investigation of the occurrence and furthermore on different influencing factors of silent breathing. The morphology of the folds responsible for the leakage was captured using high-resolution 3D microcomputed tomography (μCT). For the numerical investigations (Com-putational Fluid Dynamics - CFD), the commercial CFD Software package FLUENT 2021 R2 (ANSYS, Inc., Canonsburg, PA, US), as well as the DLR in-house research code THETA has been used.
High Spatial Resolution Tomo-PIV of the Nasopharynx Focussing on the Physiological Breathing Cycle
(2022)
Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark
of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person’s head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras‘ double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field.
Surgical smoke has been a little discussed topic in the context of the current pandemic. Surgical smoke is generated during the cauterization of tissue with heat-generating devices and consists of 95% water
vapor and 5% cellular debris in the form of particulate matter. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during tissue electrocautery. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. The higher the power of the high-frequency-device the larger the particles in size and the higher the resulting particle counts. The images taken show the densest smoke at 40W with artificial saliva. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms that the risk arising from surgical smoke should be considered. Furthermore, the experiments will provide the database for further numerical investigations.
Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots-in particular, the presence of von Willebrand factor (vWF)-may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti-vWF and anti-P-selectin) and counterstained with 4 ',6-diamidino-2-phenylindole. The extent of vWF-loading was correlated with patient and technical data. While 12 MOs showed low vWF-loadings, 9 MOs showed high vWF-loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF-fibers/"cobwebs," leukocytes, platelet-leukocyte aggregates (PLAs), and P-selectin-positive platelet aggregates were independent of the extent of vWF-loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high-molecular-weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy.
Modelling blood flow an shear induced coagulation in membraene oxygenators (MO) is challenging. The relevant geometry of oxygenator fibers (OF) and chaining threads is complex and spans several length scales. In relevant scales and regimes blood shows several significant non-Newtonian effects. Existing models are only capable of accounting for some, but not all relevant effects. Additionally, coagulation processes are influencing fluid properties and geometry significantly. Due to the enormous size of the discretised geometries highly detailed viscosity and coagulation properties of blodd flow in MOs. First step is to find a gemoetry dependent viscosity representation on basis of parametric micro channel experiments with anti-coagulated blood. Next step is a statistic coagulation model, based on micro channel experiments with human (re-calcified citrated) whole blood an evaluation of clinically used osygenators. Since shear rate dependent (i.e. viscosity dependet) coagulation in return influences the viscosity, a combined model with suitable implementation in a RANS framework is necessary. Towards this end, micro channel experiments with new and used single OFs triggering coagulation are performed. Structures of multimeric von Willebrand fibers (vWF), as indicator for shear induced coagulation, are compared to computed and measured flow conditions, using immunofluorescence microscopy, RANS-computations and µPIV, respectively. Preliminary examinations in clinically used MOs show good agreement between occurring structures of vWF, cell depositions and computed flow patterns (geometry form µCT-Scans). However, computed shear rates might be to low to actually trigger activation of vWF. The complex geometry of MOs results in huge meshes, which makes RANS with statistical modelling of viscosity and coagulation a reasonable approach. Towards this end, experimental data on micro channel level with evaluation on real application level is crucial. Especially regarding clotting processes, micro fluidic experiments are powerful research tool.
BACKGROUND:
Shear-induced conformational changes of von Willebrand factor (vWF) may be responsible for coagulation disorder and clot formation inside membrane oxygenators (MOs) during extracorporeal membrane oxygenation (ECMO) therapy.
OBJECTIVE:
The aim was to identify vWF structures inside clinically used MOs and employ computational fluid dynamics to verify the corresponding flow conditions.
METHODS:
Samples from gas exchange membranes (GEM) from MOs were analysed for accumulations of vWF and P-selectin-positive platelets using immunofluorescence techniques. Streamlines and shear rates of the flow around GEMs were computed using a laminar steady Reynolds-Averaged-Navier-Stokes approach.
RESULTS:
Most samples were colonized with equally distributed leukocytes, integrated in thin cobweb-like vWF-structures. Only 25 % of the samples showed extended accumulations of vWF. Computed streamlines showed considerable cross flow between interconnected neighbouring channels. Stagnation points were non-symmetric and contact faces were washed around closely. The occurring maximum shear rates ranged from 2,500 to 3,000 1/s.
CONCLUSIONS:
If pronounced vWF structures are present, shape and extent match the flow computations well. Computed shear rates bear a critical degree of uncertainty due to the improper viscosity model. If flow conditions inside the MO were sufficient to affect vWF, a more consistent distribution of vWF across the samples should be present.
Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose.
Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling.
Innovationsmanagement
(2011)
Das Management in der Medizinprodukteindustrie steht vor vielfältigen Herausforderungen. So sinken einerseits die Produktpreise, anderseits wird auch für die kommenden Jahre in vielen Segmenten ein Mengenwachstum erwartet. Dies stellt die internen Prozesse, vom Customer Service bis hin zur Forschung & Entwicklung, auf den Prüfstand. Die Entscheidungsträger auf Kundenseite verändern sich, weg vom Produktanwender hin zu professionellen Einkaufsgemeinschaften mit immer größerer Verhandlungsmacht. Der hohe Internationalisierungsgrad der Unternehmen führt zu einer steigenden Komplexität bei der Implementierung von Marketing-, Vertriebs- und Produktentwicklungsstrategien auf Länderebene. Darüber hinaus werden zunehmend neue Geschäftsmodelle mit hohem Dienstleistungsanteil entwickelt, die mit der traditionellen Lieferantenrolle wenig zu tun haben und von Managern eine neue Fähigkeiten für die Umsetzung erfordern. Die Autoren des Sammelbands greifen die genannten Herausforderungen auf und bieten mit ihren Beiträgen Lösungsansätze, die sowohl für Manager im Medizinprodukteunternehmen als auch für Wissenschaftler und Studierende relevant sind.
The Impact of the ObamaCare Excise Tax on Innovation and Entrepreneurship – Early Empirical Findings
(2015)
This study addresses aspects of governmental influence on innovation by analyzing the impact of the ObamaCare excise tax on the medical device industry. We initially give an overview of common approaches to measuring innovativeness and entrepreneurship, empirically assess whether existing metrics are suitable for investigating the innovation performance of the U.S. medical device industry, and define a new measure (firm innovation activity) for entrepreneurship. Then we perform a quantitative analysis to explore the impact of the tax. We analyze more than 60,000 product clearances from 1996 to 2013, using the FDA database. We find a significant relationship between product counts and revenues for one segment. Contrary to the present criticism of the excise tax, we find hardly any noteworthy response in either firm innovation activity or number of products launched in the year after the tax was introduced. The 2013 reduction of new product submissions is well within the limits of typical annual fluctuations observed in previous years. This provides a first indication that the excise tax act did not have a strong impact on innovative activities through the present.
Introduction:
Neointimal hyperplasia after percutaneous coronary intervention remains a major determinant of in-stent restenosis (ISR). The extent of mechanical vessel injury correlates with ISR. A new ex vivo porcine stent model was introduced and evaluated comparing different stent designs.
Methods:
Coronary arteries were prepared from pig hearts from the slaughterhouse and used for ex vivo implantations of coronary stents. One basic stent design in two configurations (dogbone, DB; non-dogbone, NDB) was used. Vascular injury was determined according to a modified injury score (IS).
Results:
Standardized experimental conditions ensured comparable vessel dimensions and overstretch data. DB stents caused more severe IS compared to NDB stents. The mean IS and the IS at the distal end of all stents were significantly reduced for NDB stents (ISMean, DB, 1.16 ±0.12; NDB, 1.02 ±0.12; p=0.018; ISDist, DB, 1.39 ±0.28; NDB, 1.13 ±0.24; p=0.03).
Discussion/Conclusion:
The introduced ex-vivo model allowed the evaluation of different stent designs exclude unfavorable stent designs.
The good availability and the large content of adult stem cells in adipose tissue has made it one of the most interesting tissues in regenerative medicine. Although lipofilling is one of the most frequent procedures in plastic surgery, the method still struggles with high absorption rates and volume losses of up to 70%. Therefore, many efforts have been made to optimize liposuction and to process the harvested tissue in order to increase fat graft retention. Because of their immunomodulatory properties, their cytokine secretory activity, and their differentiation potential, enrichment with adipose tissue-derived stem cells was identified as a promising tool to promote transplant survival. Here, we review the important parameters for lipofilling optimization. Finally, we present a new method for the enrichment of lipoaspirate with adipose tissue-derived stem cells and discuss the parameters that contribute to fat graft survival.