In the forming tools for pressing car body parts, heavy blankholders are used to prevent buckling and wrinkling of the blank. During each press cycle, those large masses need to be lifted, raising thereby the structural dynamic load on the forming tool and on the press. Therefore a detailed knowledge about the forming tool dynamics is essential for an accurate and robust design of forming tools. In this paper, a dynamic finite element method (FEM) simulation of selected automotive forming tool is presented enabling identification of regions of critical stresses. For validation of the simulation results, the kinematic responses of the tool's components are compared with the measurements obtained in an experiment.
Lineare und nichtlineare FEM
(2022)
Einführung in die lineare FEM - Mechanische Größen der Strukturmechanik - Mathematische Modellierung über Energieprinzipien - Diskretisierung mit Finiten Elementen - Finite-Elemente-Klassen - Mathematische und numerische Aspekte der FEM - Geometrische Nichtlinearität - Materielle Nichtlinearität - Kontaktmodellierung - Gleichungslösung bei nichtlinearen statischen Problemen - Zeitintegration von nichtlinearen dynamischen Problemen - Blechumformsimulation - Anhang: Mathematische Hilfsmittel - Einführung in die Simulation mit LS-DYNA®
Die Zielgruppen- Studierende aus Bachelor- und Masterstudiengängen der Ingenieurwissenschaften an Hochschulen und Technischen Universitäten - Ingenieure und Techniker
Lineare und nichtlineare FEM
(2019)
Einführung in die lineare FEM - Mechanische Größen der Strukturmechanik - Mathematische Modellierung über Energieprinzipien - Diskretisierung mit Finiten Elementen - Finite-Elemente-Klassen - Mathematische und numerische Aspekte der FEM - Geometrische Nichtlinearität - Materielle Nichtlinearität - Kontaktmodellierung - Gleichungslösung bei nichtlinearen statischen Problemen - Zeitintegration von nichtlinearen dynamischen Problemen - Blechumformsimulation - Anhang: Mathematische Hilfsmittel - Einführung in die Simulation mit LS-DYNA®
Die Zielgruppen- Studierende aus Bachelor- und Masterstudiengängen der Ingenieurwissenschaften an Hochschulen und Technischen Universitäten
- Ingenieure und Techniker
Fracture behavior of seamless pipeline material X65Q acc. to API 5L has been studied both experimentally and numerically at different loading conditions (quasi-static vs. dynamic) and temperatures. The recent findings have shown difficulties in applying well established methods for determination of transition behavior or prediction of ductile crack arrest for the new generation of high-toughness steels. The irregular fracture performance (e.g. so-called "abnormal inverse fracture" appearance, significant scattering in ductile-to-brittle-transition-temperature region, etc.) suggests that the influence of pipe dimensions, loading parameters, crack initiation resistance as well as testing procedure on the fracture behavior has been neither understood nor properly described. This work aims to shed light on these questions regarding the applicability of conventional methods and to better illuminate most relevant parameters affecting fracture behavior of high toughness steels. To achieve this goal, experimental data basis for analysis of fracture behavior in transition and upper shelf regime has been established by conducting quasi-static fracture mechanics tests and dynamic tests on Battelle Drop Weight Tear (BDWT or DWT) specimens at different temperatures. The evaluation of obtained test results in upper shelf has been additionally complemented by numerical simulation of damage behavior. The results highlight the influence of stress conditions on fracture behavior with reference to pipe dimensions and loading conditions and, subsequently, may be used as a basis for revision of existing design methods.
Common Schanz screw systems can be used to stabilize pelvic ring fractures. In order to accommodate for different patient’s requirements, implants can be placed in cranio-caudal direction into the os ilium (T1), or into the supraacetabular bone canal, and thus, in dorso-ventral direction (T2). Whereas both techniques are currently used, no data of the biomechanical behavior is available up to this date. The aim of this study is to analyze, whether T2 shows biomechanical advantages with respect to tissue and implant stresses due to the enlarged bone-implant interface. Forces acting on the pelvis were analyzed using motion capture data of a gait cycle obtained by the utilization of a musculoskeletal simulation program. A three dimensional finite element (FE) model of the pelvis with grayscale-based material properties was generated. The muscle and joint reaction forces at toe-off were applied to the FE model and instable pelvis fractures were implemented. The osteosynthesis systems were positioned within the model in order to enable the comparison between the two different surgical techniques. Stresses and displacements were analyzed for bone tissue, fracture zone and implant.
T2 lead to approx. 30% larger displacements in the fracture zone. Von-Mises stresses were larger for T2 in the implant (80 MPa vs. 227 MPa), whereas T1 leads to larger stresses in the bone tissue (200 MPa vs. 140 MPa).
Both implantation techniques showed a good biomechanical behavior. Differences could be found with respect to tissue strains and deformations in the fracture zone. If bone quality or fracture healing are of concern, T2 or T1 should be used, respectively. However, both techniques seem to be applicable for cases with no special requirements. Further analyses aim to investigate the behavior under cyclic loading.
Finite element (FE)–based studies of preoperative processes such as folding,pleating, and stent crimping with a comparison with experimental inflation tests are not yet available. Therefore, a novel workflow is presented in which residual stresses of balloon folding and pleating, as well as stent crimping, and the geometries of all contact partners were ultimately implemented in an FE code to simulate stent expansion by using an implicit solver. The numerical results demonstrate that the incorporation of residual stresses and strains experienced during the production step significantly increased the accuracy of the subsequent simulations, especially of the stent expansion model. During the preoperative processes, stresses inside the membrane and the stent material also reached a rather high level. Hence, there can be no presumption that balloon catheters or stents are undamaged before the actual surgery. The implementation of the realistic geometry, in particular the balloon tapers, and the blades of the process devices improved the simulation of the expansion mech-anisms, such as dogboning, concave bending, or overexpansion of stent cells. This study shows that implicit solvers are able to precisely simulate the mentioned preoperative processes and the stent expansion procedure without a preceding manipulation of the simulation time or physical mass.
Introduction: Previous studies of bone stresses in the human lumbar spine have relied on simplified models when modeling the spinal musculature, even though muscle forces are likely major contributors to the stresses in the vertebral bones. Detailed musculoskeletal spine models have recently become available and show good correlation with experimental findings. A combined inverse dynamics and finite element analysis study was conducted in the lumbar spine to investigate the effects of muscle forces on a detailed musculoskeletal finite element model of the 4th lumbar vertebral body. Materials and Methodology: The muscle forces were computed with a detailed and validated inverse dynamics musculoskeletal spine model in a lifting situation, and were then applied to an orthotropic finite element model of the 4th lumbar vertebra. The results were compared with those from a simplified load case without muscles. Results: In general the von Mises stress was larger by 30%, and even higher when looking at the von Mises stress distribution in the superio-anterior and central part of the vertebral body and in the pedicles. Conclusion: The application of spine muscles to a finite element model showed markedly larger von Mises stress responses in the central and anterior part of the vertebral body, which can be tolerated in the young and healthy spine, but it would increase the risk of compression fractures in the elderly, osteoporotic spine.