Ductile failure of structural metals is relevant to a wide range of engineering scenarios. Computational methods are employed to anticipate the critical conditions of failure, yet they sometimes provide inaccurate and misleading predictions. Challenge scenarios, such as the one presented in the current work, provide an opportunity to assess the blind, quantitative predictive ability of simulation methods against a previously unseen failure problem. Rather than evaluate the predictions of a single simulation approach, the Sandia Fracture Challenge relies on numerous volunteer teams with expertise in computational mechanics to apply a broad range of computational methods, numerical algorithms, and constitutive models to the challenge. This exercise is intended to evaluate the state of health of technologies available for failure prediction. In the first Sandia Fracture Challenge, a wide range of issues were raised in ductile failure modeling, including a lack of consistency in failure models, the importance of shear calibration data, and difficulties in quantifying the uncertainty of prediction [see Boyce et al. (Int J Fract 186:5-68, 2014) for details of these observations]. This second Sandia Fracture Challenge investigated the ductile rupture of a Ti-6Al-4V sheet under both quasi-static and modest-rate dynamic loading (failure in 0.1 s). Like the previous challenge, the sheet had an unusual arrangement of notches and holes that added geometric complexity and fostered a competition between tensile- and shear-dominated failure modes. The teams were asked to predict the fracture path and quantitative far-field failure metrics such as the peak force and displacement to cause crack initiation. Fourteen teams contributed blind predictions, and the experimental outcomes were quantified in three independent test labs. Additional shortcomings were revealed in this second challenge such as inconsistency in the application of appropriate boundary conditions, need for a thermomechanical treatment of the heat generation in the dynamic loading condition, and further difficulties in model calibration based on limited real-world engineering data. As with the prior challenge, this work not only documents the 'state-of-the-art' in computational failure prediction of ductile tearing scenarios, but also provides a detailed dataset for non-blind assessment of alternative methods.
The focus of this paper is the simulation of fatigue crack growth of the coated single crystalline nickel-based superalloy PWA 1484 under thermal mechanical loading. Thus, two physical models are superimposed in terms to firstly calculate the deformation behavior under instationary thermal and mechanical loading (TMF) and secondly to model crack propagation after initial brittle cracking of the coating layer on the basis of cyclic crack tip opening displacement (CTOD). All material parameters implemented in the models were evaluated from monotonic isothermal tensile and creep tests as well as from isothermal low cycle fatigue (LCF) experiments. The calculated fatigue crack growth was validated by in situ crack growth measurements using the beachmark technique. Hence, crack propagation initiated by the brittle coating system closely to the experimental results using rectangular flat specimen geometry instead of corner-crack (CC) specimens. The comparison of the simulated lifetimes to the experimental results provides remarkable accuracy of the physically-based lifetime model.
Experimental and mathematical characterization of coronary polyamide-12 balloon catheter membranes
(2020)
The experimental quantification and modeling of the multiaxial mechanical response of polymer membranes of coronary balloon catheters have not yet been carried out. Due to the lack of insights, it is not shown whether isotropic material models can describe the material response of balloon catheter membranes expanded with nominal or higher, supra-nominal pressures. Therefore, for the first time, specimens of commercial polyamide-12 balloon catheters membranes were investigated during uniaxial and biaxial loading scenarios. Furthermore, the influence of kinematic effects on the material response was observed by comparing results from quasi-static and dynamic biaxial extension tests. Novel clamping techniques are described, which allow to test even tiny specimens taken from the balloon membranes. The results of this study reveal the semi-compliant, nonlinear, and viscoelastic character of polyamide-12 balloon catheter membranes. Above nominal pressure, the membranes show a pronounced anisotropic mechanical behavior with a stiffer response in the circumferential direction. The anisotropic feature intensifies with an increasing strain-rate. A modified polynomial model was applied to represent the realistic mechanical response of the balloon catheter membranes during dynamic biaxial extension tests. This study also includes a compact set of constitutive model parameters for the use of the proposed model in future finite element analyses to perform more accurate simulations of expanding balloon catheters.
Advances in additive manufacturing enable the production of tailored lattice structures and thus, in principle, coronary stents. This study investigates the effects of process-related irregularities, heat and surface treatment on the morphology, mechanical response, and expansion behavior of 316L stainless steel stents produced by laser powder bed fusion and provides a methodological approach for their numerical evaluation. A combined experimental and computational framework is used, based on both actual and computationally reconstructed laser powder bed fused stents. Process-related morphological deviations between the as-designed and actual laser powder bed fused stents were observed, resulting in a diameter increase by a factor of 2-2.6 for the stents without surface treatment and 1.3-2 for the electropolished stent compared to the as-designed stent. Thus, due to the increased geometrically induced stiffness, the laser powder bed fused stents in the as-built (7.11 ± 0.63 N) or the heat treated condition (5.87 ± 0.49 N) showed increased radial forces when compressed between two plates. After electropolishing, the heat treated stents exhibited radial forces (2.38 ± 0.23 N) comparable to conventional metallic stents. The laser powder bed fused stents were further affected by the size effect, resulting in a reduced yield strength by 41% in the as-built and by 59% in the heat treated condition compared to the bulk material obtained from tensile tests. The presented numerical approach was successful in predicting the macroscopic mechanical response of the stents under compression. During deformation, increased stiffness and local stress concentration were observed within the laser powder bed fused stents. Subsequent numerical expansion analysis of the derived stent models within a previously verified numerical model of stent expansion showed that electropolished and heat treated laser powder bed fused stents can exhibit comparable expansion behavior to conventional stents. The findings from this work motivate future experimental/numerical studies to quantify threshold values of critical geometric irregularities, which could be used to establish design guidelines for laser powder bed fused stents/lattice structures.
The Sandia Fracture Challenges provide a forum for the mechanics community to assess its ability to predict ductile fracture through a blind, round-robin format where mechanicians are challenged to predict the deformation and failure of an arbitrary geometry given experimental calibration data. The Third Challenge (SFC3) required participants to predict fracture in an additively manufactured (AM) 316L stainless steel bar containing through holes and internal cavities that could not have been conventionally machined. The volunteer participants were provided extensive data including tension and notched tensions tests of 316L specimens built on the same build-plate as the Challenge geometry, micro-CT scans of the Challenge specimens and geometric measurements of the feature based on the scans, electron backscatter diffraction (EBSD) information on grain texture, and post-test fractography of the calibration specimens. Surprisingly, the global behavior of the SFC3 geometry specimens had modest variability despite being made of AM metal, with all of the SFC3 geometry specimens failing under the same failure mode. This is attributed to the large stress concentrations from the holes overwhelming the stochastic local influence of the AM voids and surface roughness. The teams were asked to predict a number of quantities of interest in the response based on global and local measures that were compared to experimental data, based partly on Digital Image Correlation (DIC) measurements of surface displacements and strains, including predictions of variability in the resulting fracture response, as the basis for assessment of the predictive capabilities of the modeling and simulation strategies. Twenty-one teams submitted predictions obtained from a variety of methods: the finite element method (FEM) or the mesh-free, peridynamic method; solvers with explicit time integration, implicit time integration, or quasi-statics; fracture methods including element deletion, peridynamics with bond damage, XFEM, damage (stiffness degradation), and adaptive remeshing. These predictions utilized many different material models: plasticity models including J2 plasticity or Hill yield with isotropic hardening, mixed Swift-Voce hardening, kinematic hardening, or custom hardening curves; fracture criteria including GTN model, Hosford-Coulomb, triaxiality-dependent strain, critical fracture energy, damage-based model, critical void volume fraction, and Johnson-Cook model; and damage evolution models including damage accumulation and evolution, crack band model, fracture energy, displacement value threshold, incremental stress triaxiality, Cocks-Ashby void growth, and void nucleation, growth, and coalescence. Teams used various combinations of calibration data from tensile specimens, the notched tensile specimens, and literature data. A detailed comparison of results based of these different methods is presented in this paper to suggest a set of best practices for modeling ductile fracture in situations like the SFC3 AM-material problem. All blind predictions identified the nominal crack path and initiation location correctly. The SFC3 participants generally fared better in their global predictions of deformation and failure than the participants in the previous Challenges, suggesting the relative maturity of the models used and adoption of best practices from previous Challenges. This paper provides detailed analyses of the results, including discussion of the utility of the provided data, challenges of the experimental-numerical comparison, defects in the AM material, and human factors.
In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis.