Fakultät Maschinenbau
Refine
Year of publication
Document Type
- Article (358)
- conference proceeding (article) (353)
- conference proceeding (presentation, abstract) (57)
- conference talk (49)
- Part of a Book (24)
- Book (18)
- Report (18)
- Doctoral Thesis (10)
- Preprint (6)
- Patent (5)
Is part of the Bibliography
- no (907)
Keywords
- Simulation (19)
- additive manufacturing (15)
- Biomechanik (13)
- Biomechanics (10)
- Hüftgelenkprothese (9)
- simulation (8)
- Biomechanische Analyse (7)
- Finite-Elemente-Methode (7)
- Kunststoff (7)
- Deformation (6)
Institute
- Fakultät Maschinenbau (907)
- Regensburg Center of Biomedical Engineering - RCBE (214)
- Labor Biomechanik (LBM) (153)
- Technologie-Campus Neustadt an der Donau (100)
- Labor Faserverbundtechnik (LFT) (70)
- Labor Finite-Elemente-Methode (FEM) (67)
- Labor Laser-Materialbearbeitung (LMP) (59)
- Labor CAD/CAE (54)
- Labor Mehrkörpersimulation (MKS) (54)
- Computational Mechanics and Materials Lab (CMM) (45)
Begutachtungsstatus
- peer-reviewed (339)
- begutachtet (18)
Pelvic floor dysfunction is a common problem in women and has a negative impact ontheir quality of life. The aim of this review was to provide a general overview of the current state oftechnology used to assess pelvic floor functionality. It also provides literature research of the phys-iological and anatomical factors that correlate with pelvic floor health. The systematic review wasconducted according to the PRISMA guidelines. PubMed, ScienceDirect, Cochrane Library andIEEE databases were searched for publications on sensor technology for the assessment of pelvicfloor functionality. Anatomical and physiological parameters were identified through a manualsearch. In the systematic review 115 publications were included. 12 different sensor technologieswere identified. Information on the obtained parameters, sensor position, test activities and subjectcharacteristics were prepared in tabular form from each publication. 16 anatomical and physiologi- cal parameters influencing pelvic floor health were identified in 17 published studies and rankedfor their statistical significance. Taken together, this review could serve as a basis for the develop-ment of novel sensors which could allow for quantifiable prevention and diagnosis, as well as par-ticularized documentation of rehabilitation processes related to pelvic floor dysfunctions.
Pelvic floor dysfunction is a common problem in women and has a negative impact on their quality of life. The aim of this review was to provide a general overview of the current state of technology used to assess pelvic floor functionality. It also provides literature research of the physiological and anatomical factors that correlate with pelvic floor health. This systematic review was conducted according to the PRISMA guidelines. The PubMed, ScienceDirect, Cochrane Library, and IEEE databases were searched for publications on sensor technology for the assessment of pelvic floor functionality. Anatomical and physiological parameters were identified through a manual search. In the systematic review, 114 publications were included. Twelve different sensor technologies were identified. Information on the obtained parameters, sensor position, test activities, and subject characteristics was prepared in tabular form from each publication. A total of 16 anatomical and physiological parameters influencing pelvic floor health were identified in 17 published studies and ranked for their statistical significance. Taken together, this review could serve as a basis for the development of novel sensors which could allow for quantifiable prevention and diagnosis, as well as particularized documentation of rehabilitation processes related to pelvic floor dysfunctions.
Extracorporeal membrane oxygenation (ECMO) was established as a treatment for severe cardiac or respiratory disease. Intra-device clot formation is a common risk. This is based on complex coagulation phenomena which are not yet sufficiently understood. The objective was the development and validation of a methodology to capture the key properties of clots deposed in membrane lungs (MLs), such as clot size, distribution, burden, and composition. One end-oftherapy PLS ML was examined. Clot detection was performed using multidetector computed tomography (MDCT), microcomputed tomography (μCT), and photography of fiber mats (fiber mat imaging, FMI). Histological staining was conducted for von Willebrand factor (vWF), platelets (CD42b, CD62P), fibrin, and nucleated cells (4′, 6-diamidino-2-phenylindole, DAPI). The three imaging
methods showed similar clot distribution inside the ML. Independent of the imaging method, clot loading was detected predominantly in the inlet chamber of the ML. The μCT had the highest accuracy. However, it was more expensive and time consuming than MDCT or FMI. The MDCT detected the clots with low scanning time. Due to its lower resolution, it only showed clotted areas but not
the exact shape of clot structures. FMI represented the simplest variant, requiring little effort and resources. FMI allowed clot localization and calculation of clot volume. Histological evaluation indicated omnipresent immunological deposits throughout the ML. Visually clot-free areas were covered with leukocytes and platelets forming platelet-leukocyte aggregates (PLAs). Cells were embedded in vWF cobwebs, while vWF fibers were negligible. In conclusion, the presented
methodology allowed adequate clot identification and histological classification
of possible thrombosis markers such as PLAs.
The use of intrinsically compliant tensegrity structures in manipulation systems is an attractive research topic. In this paper a 3D compliant robotic arm based on a stacked tensegrity structure consisting of x-shaped rigid members is considered. The rigid members are interconnected by a net of prestressed, tensioned members with pronounced intrinsic elasticity and by inelastic tensioned members. The system's motion is achieved by length-change of the inelastic tensioned members. The operating principle of the system is discussed with the help of kinematic considerations and verified by experiments.
Lumped-Mass-Modellierung von Förderbändern am Beispiel eines Zwei-Walzensystems mit flexiblen Walzen
(2024)
Background and objectiveDue to the high prevalence of dental caries, fixed dental restorations are regularly required to restore compromised teeth or replace missing teeth while retaining function and aesthetic appearance. The fabrication of dental restorations, however, remains challenging due to the complexity of the human masticatory system as well as the unique morphology of each individual dentition. Adaptation and reworking are frequently required during the insertion of fixed dental prostheses (FDPs), which increase cost and treatment time. This article proposes a data-driven approach for the partial reconstruction of occlusal surfaces based on a data set that comprises 92 3D mesh files of full dental crown restorations.MethodsA Generative Adversarial Network (GAN) is considered for the given task in view of its ability to represent extensive data sets in an unsupervised manner with a wide variety of applications. Having demonstrated good capabilities in terms of image quality and training stability, StyleGAN-2 has been chosen as the main network for generating the occlusal surfaces. A 2D projection method is proposed in order to generate 2D representations of the provided 3D tooth data set for integration with the StyleGAN architecture. The reconstruction capabilities of the trained network are demonstrated by means of 4 common inlay types using a Bayesian Image Reconstruction method. This involves pre-processing the data in order to extract the necessary information of the tooth preparations required for the used method as well as the modification of the initial reconstruction loss.ResultsThe reconstruction process yields satisfactory visual and quantitative results for all preparations with a root mean square error (RMSE) ranging from 0.02 mm to 0.18 mm. When compared against a clinical procedure for CAD inlay fabrication, the group of dentists preferred the GAN-based restorations for 3 of the total 4 inlay geometries.ConclusionsThis article shows the effectiveness of the StyleGAN architecture with a downstream optimization process for the reconstruction of 4 different inlay geometries. The independence of the reconstruction process and the initial training of the GAN enables the application of the method for arbitrary inlay geometries without time-consuming retraining of the GAN.
Im Betrieb von Förderbändern auftretende Phänomene sind das Bandwandern in Achsrichtung der Walzen und die Bandverformung in der Bandebene [1, S. 142]. Das Bandwandern ist bisher detailliert untersucht [2–4], während die Bandverformung Gegenstand weniger Veröffentlichungen ist. Deshalb wird in diesem Artikel eine Methode zur Berechnung der sich im dynamischen Betrieb einstellenden Verformung eines elastischen Förderbandes vorgestellt. Dazu wird ein Mehrkörpersimulations-Modell basierend auf der Lumped-Mass-Modellierung verwendet. Als Untersuchungsbeispiel dient ein Zwei-Walzensystem mit flexiblen und zylindrischen Walzen, sowie ein flexibles Förderband. Es zeigt sich, dass mit der Lumped-Mass-Modellierung eine dynamische Bandverformung, die von der gewählten Diskretisierung abhängt, berechnet werden kann. Aufgrund dieser Abhängigkeit ist es notwendig eine Konvergenzanalyse durchzuführen. Zusätzlich ist darauf zu achten, dass die künstliche Anregung aufgrund der Lumped-Mass-Modellierung nicht mit einer Eigenfrequenz des Modells zusammenfällt.
Bei der Untersuchung und Optimierung der Getriebedynamik, im Sinne der Akustik und Lastverteilung, wird oftmals der Drehwegfehler als Bewertungskriterium herangezogen. Zahlreiche Forschungsvorhaben haben sich in diesem Zusammenhang intensiv mit dem Drehwegfehler als parametererregte Schwingungsanregung auseinandergesetzt, um diesen im Hinblick auf das Systemverhalten zu optimieren. Dabei bleibt der Zahnfußbereich, welcher außerhalb der Evolvente liegt, und dessen Einfluss auf den Drehwegfehler oftmals unberücksichtigt.
Dieser Artikel untersucht daher den Einfluss des Zahnfußbereiches auf den statischen Drehwegfehler, indem relevante Größen wie das spezifische Kopfspiel und der Fußrundungsradius an einer typischen und real eingesetzten Stirnradverzahnung variiert werden.
Ferner wird betrachtet, inwiefern der Drehwegfehler durch unterschiedliche Geometriedefinitionen (Fertigungssimulation, Zahngeometrie mit vereinfachter sowie stark vereinfachter Modellierung des Zahnfußbereichs) beeinflusst wird. Die Autoren nutzen hierfür zwei FE-Ansätze (adaptives und nicht-adaptives Netz) und bewerten diese hinsichtlich ihrer Gültigkeit, Modellgüte und Praktikabilität.
Die Ergebnisse der Untersuchungen werden hinsichtlich einer minimal erforderlichen Geometrie des Zahnfußbereiches interpretiert. Für den Praxistransfer wird einerseits der maximale Fehler bei Nichtberücksichtigung des gesamten Zahnfußbereichs beziffert.
Andererseits wird eine Empfehlung zur Anpassung einer vereinfachten Geometrie, an eine Geometrie, ähnlich der aus einer Fertigungssimulation, gegeben. Weiterhin wird der Artikel diskutieren, ob man ein vereinfachtes Zahnmodell zur Berechnung der Getriebedynamik nutzen kann, wenn der Fertigungsprozess noch nicht definiert ist.
Generative deep learning approaches for the design of dental restorations: A narrative review
(2024)
Objectives:
This study aims to explore and discuss recent advancements in tooth reconstruction utilizing deep learning (DL) techniques. A review on new DL methodologies in partial and full tooth reconstruction is conducted.
Data/Sources:
PubMed, Google Scholar, and IEEE Xplore databases were searched for articles from 2003 to 2023.
Study selection:
The review includes 9 articles published from 2018 to 2023. The selected articles showcase novel DL approaches for tooth reconstruction, while those concentrating solely on the application or review of DL methods are excluded. The review shows that data is acquired via intraoral scans or laboratory scans of dental plaster models. Common data representations are depth maps, point clouds, and voxelized point clouds. Reconstructions focus on single teeth, using data from adjacent teeth or the entire jaw. Some articles include antagonist teeth data and features like occlusal grooves and gap distance. Primary network architectures include Generative Adversarial Networks (GANs) and Transformers. Compared to conventional digital methods, DL-based tooth reconstruction reports error rates approximately two times lower.
Conclusions:
Generative DL models analyze dental datasets to reconstruct missing teeth by extracting insights into patterns and structures. Through specialized application, these models reconstruct morphologically and functionally sound dental structures, leveraging information from the existing teeth. The reported advancements facilitate the feasibility of DL-based dental crown reconstruction. Beyond GANs and Transformers with point clouds or voxels, recent studies indicate promising outcomes with diffusion-based architectures and innovative data representations like wavelets for 3D shape completion and inference problems.
Clinical significance:
Generative network architectures employed in the analysis and reconstruction of dental structures demonstrate notable proficiency. The enhanced accuracy and efficiency of DL-based frameworks hold the potential to enhance clinical outcomes and increase patient satisfaction. The reduced reconstruction times and diminished requirement for manual intervention may lead to cost savings and improved accessibility of dental services.
The present paper takes a novel approach to production of fibre-reinforced thermoplastic tubes. The method begins with the raw materials, reinforcing fibre and thermoplastic granulate which are processed to tapes through a newly developed direct impregnation process. It is followed by consolidation of fibre-reinforced thermoplastic tubes using infrared (IR) emitters in the filament winding process. This process employs various angles and utilizes a rotatable consolidation axis. The winding process operates at a constant speed, addressing the challenge of bending the fibre-reinforced tapes in the angle reversal areas near the tube ends. Experiments have confirmed that the process can run at speeds reaching approximately 470 mm/min. The design of the impregnation line takes into account the properties of the thermoplastic and the roving, allowing for a speed of up to 1 m/s.
One major goal of production system design is to decide on space requirements in the plant. In this phase, detailed information about the supply chain network (e.g. which suppliers deliver which parts) is often unavailable. Nevertheless, typical decisions in supply chain management, like the definition of replenishment processes and quantities or make-or-buy decisions, impact space requirements and the capital investment in raw materials and should therefore be considered in factory and production planning. This research article proposes a simulation approach for a production simulation in which raw material replenishment is integrated to evaluate the capital investment and space requirements for raw materials.
Transient surrogate modeling of modally reduced structures with discontinuous loads and damping
(2024)
In this work, a surrogate model for structural, transient and discontinuously excited finite element method simulations is developed. This allows to reduce the computational effort of repeated calculations of identical models under different load cases. The architecture of the surrogate combines fully connected neural network layers with long short-term memory layers. For the reproduction of different damping ratios, a categorical variable is added to the continuous input data. Based on a recursive flow of the predicted data back to the input layer, long-term dependencies do not vanish due to short-input sequences. The system dimension is reduced by applying the model-order reduction technique for modal decomposition. The high accuracy of the surrogate and the reduction of computational costs are shown on an academic example of a cantilever beam and a real-world example of a robot. The advantages of our approach are illustrated in comparison with state-of-the-art surrogates for transient finite element analysis. By using the surrogate proposed in this study, oscillations due to discontinuous excitation of mechanical structures can be reproduced. For this purpose, only short-input sequences are necessary since the excitation of the oscillations does not have to be part of the input sequence during the whole duration of the oscillations. Due to the categorical variable for the damping ratio, the surrogate can account for the influence of different damping in parameter studies.
In the early-stage development of sheet metal parts, key design properties of new structures must be specified. As these decisions are made under significant uncertainty regarding drawing configuration changes, they sometimes result in the development of new parts that, at a later design stage, will not be drawable. As a result, there is a need to increase the certainty of experience-driven drawing configuration decisions.
Complementing this process with a global sensitivity analysis can provide insight into the impact of various changes in drawing configurations on drawability, unveiling cost-effective strategies to ensure the drawability of new parts. However, when quantitative global sensitivity approaches, such as Sobol's method, are utilized, the computational requirements for obtaining Sobol indices can become prohibitive even for small application problems. To circumvent computational limitations, we evaluate the applicability of different surrogate models engaged in computing global design variable sensitivities for the drawability assessment of a deep-drawn component.
Here, we show in an exemplary application problem, that both a standard kriging model and an ensemble model can provide commendable results at a fraction of the computational cost. Moreover, we compare our surrogate models to existing approaches in the field. Furthermore, we show that the error introduced by the surrogate models is of the same order of magnitude as that from the choice of drawability measure. In consequence, our surrogate models can improve the cost-effective development of a component in the early design phase.
AbstractRegularized static friction models have been used successfully for many years. However, they are unable to maintain static friction in detail. For this reason, dynamic friction models have been developed and published in the literature. However, commercial multibody simulation packages such as Adams, RecurDyn, and Simpack have developed their own specific stick-slip models instead of adopting one of the public domain approaches. This article introduces the fundamentals of these commercial models and their behavior from a practical point of view. The stick-slip models were applied to a simple test model and a more sophisticated model of a festoon cable system using their standard parameters.
The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes.
Test Setup for Investigating the Impact Behavior of Biaxially Prestressed Composite Laminates
(2024)
Instrumented impact testing and compression-after-impact testing are important to adequately qualify material behavior and safely design composite structures. However, the stresses to which fiber-reinforced plastic components are typically subjected in practice are not considered in the impact test methods recommended in guidelines or standards. In this paper, a test setup for investigating the impact behavior of composite specimens under plane uniaxial and biaxial preloading is presented. For this purpose, a special test setup consisting of a biaxial testing machine and a specially designed drop-weight tower was developed. The design decisions were derived from existing guidelines and standards with the aim of inducing barely visible impact damage in laminated carbon fiber-reinforced plastic specimens. Several measurement systems have been integrated into the setup to allow comprehensive observation of the impact event and specimen behavior. A feasibility test was performed with biaxially prestressed carbon fiber-reinforced plastic specimens in comparison with unstressed reference tests. The compressive-tensile prestressing resulted in lower maximum contact forces, higher maximum deflections, higher residual deflections and a different damage pattern, which was investigated by light microscopic analysis. Finally, the functionality of the experimental setup is discussed, and the results seem to indicate that the test setup and parameters were properly chosen to investigate the effect of prestresses on the impacts behavior of composite structures, in particular for barely visible subsequent damages.
Progress in additive manufacturing is leading to the emergence of new areas of application. Laser Powder Bed Fusion (L-PBF) is increasingly used for the development of metallic medical implants, but for high-risk implants like vascular support structures (stents), surface quality is critical to ensure successful implantation without harming the surrounding tissue and ensure the patients’ health. Therefore, enhancing the surface quality is crucial. Electropolishing is a method for removing surface roughness by smoothing out micro-peaks and valleys. However, L-PBF structures have a high surface roughness due to metal particles adhering on the surface. To achieve a smooth surface for additively manufactured implants like stents using electropolishing, the removal of these particles needs to be studied in more detail.
The objective of this study is to examine the electropolishing mechanism of 316L stainless steel samples additively manufactured through Laser Powder Bed Fusion (L-PBF). The main objective is to investigate the removal properties and surface characteristics during electropolishing. To achieve this, various surfaces were characterized for morphology and roughness during Hull cell experiments. Markings are utilized on the Hull cell sample surfaces to identify points of interest during quasi-in-situ measurements. The surfaces are then analyzed after multiple time steps, applying different currents to investigate particle dissolution. The surface characteristics are analyzed through scanning electron microscopy, and surface roughness is analyzed using laser scanning microscopy.
The results show that the electropolishing process preferentially removes the adhering particles present on the surface of the samples. Increasing the current density results in faster particle dissolution and a smoother surface (see Figure 1a and b). The mechanism of material removal of various surface features, as shown in Figure 1 (red circle, yellow arrow and red square), was assessed based on the experimental results of the surface structures seen on the SEM images. It was found that different surface features were removed during the experiment at different polishing times and current densities. The amount of charge flowed was found to correlate with surface morphology.
Based on the obtained results, various surface features (such as large adherent particles, agglomerates of smaller particles, and valleys) and their changes with increasing test duration and current density were observed by quasi-in situ analyses. A reduction in the diameter of round particles adhering to the surface was observed at both low and higher current densities (see Figure 1a red circle a). Increasing the polishing time resulted in leveling of both large particles and valleys (see Figure 1b red square). Also, dissolution of agglomerates of smaller particles occurred at different polishing times as a function of current density and polishing time (see Figure 1a yellow arrow) are observed.
Smoothed surface structures can be observed in regions with equivalent surface charge density (see Figure 2). As a result, comparable surface morphologies may appear at the same area charge density, irrespective of a specific current density. So, it may be adequate to only consider the amount of charge flowed to describe the electropolishing of additive materials.
In conclusion, comprehending the dissolution characteristics of particles on L-PBF surfaces is essential for attaining satisfactory surface finish in electropolishing. The results of this study offer valuable perspectives into the electropolishing mechanism of additively manufactured 316L stainless steel and can guide future investigations on surface finishing and polishing of additive manufactured implants like stents.
Figure 1