Fakultät Informatik und Mathematik
Refine
Year of publication
Document Type
- conference proceeding (article) (436)
- Article (392)
- Part of a Book (87)
- conference proceeding (presentation, abstract) (87)
- conference proceeding (volume) (23)
- Preprint (22)
- Book (21)
- Report (16)
- Working Paper (11)
- conference talk (8)
Is part of the Bibliography
- no (1126)
Keywords
- Bildgebendes Verfahren (22)
- Deep Learning (20)
- Produktionsplanung (18)
- Betriebliches Informationssystem (16)
- Künstliche Intelligenz (16)
- Diagnose (14)
- Gebärmutterhalskrebs (14)
- Informationstechnik (14)
- Maschinelles Lernen (14)
- Artificial Intelligence (13)
Institute
- Fakultät Informatik und Mathematik (1126)
- Labor für Technikfolgenabschätzung und Angewandte Ethik (LaTe) (183)
- Regensburg Medical Image Computing (ReMIC) (158)
- Institut für Sozialforschung und Technikfolgenabschätzung (IST) (144)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (97)
- Labor Empirische Sozialforschung (93)
- Regensburg Strategic IT Management (ReSITM) (88)
- Labor für Digitalisierung (LFD) (84)
- Labor eHealth (eH) (66)
- Regensburg Center of Health Sciences and Technology - RCHST (57)
Begutachtungsstatus
- peer-reviewed (488)
- begutachtet (5)
In this paper we present a practical example of the use of Cellular Communication standards like GPRS and UMTS in a Smart Grid Application. For a more detailed view we demonstrate a possible implementation of Cellular Communication Technologies in a data acquisition application for the collection of energy indicators in a medium-voltage grid. Furthermore, we show a technical overview of relevant and common mobile communication standards available in Germany. The included theoretical examples, Smart Grid scenarios, presented data and results are based on a research project for intelligent power regulation in medium-voltage grids performed in Regensburg (Germany). It is a joint project' of the University of Applied Sciences Regensburg together with a local energy provider and a manufacturer for distribution network systems.
Blockchain and GDPR
(2019)
Blockchain and the European General Data Protection Regulation (GDPR) are two topics that are currently highly discussed in academia and amongst professionals. The Blockchain technology is claimed to revolutionize how business is being conducted by its way of storing data and sharing it with others. The recently introduced GDPR has a huge impact on processing personal data because it brought major changes to privacy regulation. This might also affect the processing of personal data in Blockchain-based application scenarios. Based on literature analysis, the paper at hand provides an overview of the Blockchain technology, presents a decision model, and introduces two possible Blockchain application scenarios. It analyses relevant requirements of the GDPR in view of processing personal data and compares these with the fundamental principles of the Blockchain technology. The paper concludes that processing personal data in the Blockchain is violating the GDPR because it conflicts with fundamental specification of this regulation. This finding reveals the need for further research to propose concepts and frameworks for a GDPR-compliant processing of personal data using Blockchain technology.
Einleitung Die Endoskopische Retrograde Cholangiopankreatikographie (ERCP) ist der Goldstandard in der Diagnostik und Therapie von Erkrankungen des pankreatobiliären Trakts. Jedoch ist sie technisch sehr anspruchsvoll und weist eine vergleichsweise hohe Komplikationsrate auf.
Ziele
In der vorliegenden Machbarkeitsstudie soll geprüft werden, ob mithilfe eines Deep-learning-Algorithmus die Papille und das Ostium zuverlässig detektiert werden können und somit für Endoskopiker mit geringer Erfahrung ein geeignetes Hilfsmittel, insbesondere für die Ausbildungssituation, darstellen könnten.
Methodik
Wir betrachteten insgesamt 606 Bilddatensätze von 65 Patienten. In diesen wurde sowohl die Papilla duodeni major als auch das Ostium segmentiert. Anschließend wurde eine neuronales Netz mittels eines Deep-learning-Algorithmus trainiert. Außerdem erfolgte eine 5-fache Kreuzvaldierung.
Ergebnisse
Bei einer 5-fachen Kreuzvaldierung auf den 606 gelabelten Daten konnte für die Klasse Papille eine F1-Wert von 0,7908, eine Sensitivität von 0,7943 und eine Spezifität von 0,9785 erreicht werden, für die Klasse Ostium eine F1-Wert von 0,5538, eine Sensitivität von 0,5094 und eine Spezifität von 0,9970 (vgl. [Tab. 1]). Unabhängig von der Klasse zeigte sich gemittelt (Klasse Papille und Klasse Ostium) ein F1-Wert von 0,6673, eine Sensitivität von 0,6519 und eine Spezifität von 0,9877 (vgl. [Tab. 2]).
Schlussfolgerung
In vorliegende Machbarkeitsstudie konnte das neuronale Netz die Papilla duodeni major mit einer hohen Sensitivität und sehr hohen Spezifität identifizieren. Bei der Detektion des Ostiums war die Sensitivität deutlich geringer. Zukünftig soll das das neuronale Netz mit mehr Daten trainiert werden. Außerdem ist geplant, den Algorithmus auch auf Videos anzuwenden. Somit könnte langfristig ein geeignetes Hilfsmittel für die ERCP etabliert werden.
GraphMIC is a cross-platform image processing application utilizing the libraries ITK and OpenCV. The abstract structure of image processing pipelines is visually represented by user interface components based on modern QtQuick technology and allows users to focus on arrangement and parameterization of operations rather than implementing the equivalent functionality natively in C++. The application's central goal is to improve and simplify the typical workflow by providing various high level features and functions like multi threading, image sequence processing and advanced error handling. A built-in python interpreter allows the creation of custom nodes, where user defined algorithms can be integrated to extend basic functionality. An embedded 2d/3d visual-izer gives feedback of the resulting image of an operation or the whole pipeline. User inputs like seed points, contours or regions are forwarded to the processing pipeline as parameters to offer semi-automatic image computing. We report the main concept of the application and introduce several features and their implementation. Finally, the current state of development as well as future perspectives of GraphMIC are discussed
Quantum computing is a relatively new paradigm that has raised considerable interest in physics and computer science in general but has so far received little attention in software engineering and architecture. Hybrid applications that consist of both quantum and classical components require the development of appropriate quantum software architectures. However, given that quantum software engineering (QSE) in general is a new research area, quantum software architecture–a subresearch area in QSE is also understudied. The goal of this chapter is to provide a list of research challenges and opportunities for such architectures. In addition, to make the content understandable to a broader computer science audience, we provide a brief overview of quantum computing and explain the essential technical foundations.
Algorithm selection (AS) tasks are dedicated to find the optimal algorithm for an unseen problem instance. With the knowledge of problem instances’ meta-features and algorithms’ landmark performances, Machine Learning (ML) approaches are applied to solve AS problems. However, the standard training process of benchmark ML approaches in AS either needs to train the models specifically for every algorithm or relies on the sparse one-hot encoding as the algorithms’ representation. To escape these intermediate steps and form the mapping function directly, we borrow the learning to rank framework from Recommender System (RS) and embed the bi-linear factorization to model the algorithms’ performances in AS. This Bi-linear Learning to Rank (BLR) has proven to work with competence in some AS scenarios and thus is also proposed as a benchmark approach. Thinking from the evaluation perspective in the modern AS challenges, precisely predicting the performance is usually the measuring goal. Though approaches’ inference time also needs to be counted for the running time cost calculation, it’s always overlooked in the evaluation process. The multi-objective evaluation metric Adjusted Ratio of Root Ratios (A3R) is therefore advocated in this paper to balance the trade-off between the accuracy and inference time in AS. Concerning A3R, BLR outperforms other benchmarks when expanding the candidates range to TOP3. The better effect of this candidates expansion results from the cumulative optimum performance during the AS process. We take the further step in the experimentation to represent the advantage of such TOPK expansion, and illustrate that such expansion can be considered as the supplement for the convention of TOP1 selection during the evaluation process.
This White Paper outlines how the ethical discourse on cybersecurity has developed in the scientific literature, which ethical issues gained interest, which value conflicts are discussed, and where the “blind spots” in the current ethical discourse on cybersecurity are located. The White Paper is based on an extensive literature with a focus on three reference domains with unique types of value conflicts: health, business/finance and national security. For each domain, a systematic literature search has been performed and the identified papers have been analysed using qualitative and quantitative methods. An important observation is that the ethics of cybersecurity not an established subject. In all domains, cybersecurity is recognized as being an instrumental value, not an end in itself, which opens up the possibility of trade-offs with different values in different spheres. The most prominent common theme is the existence of trade-offs and even conflicts between reasonable goals, for example between usability and security, accessibility and security, privacy and convenience. Other prominent common themes are the importance of cybersecurity to sustain trust (in institutions), and the harmful effect of any loss of control over data.
Backround
Scaphoidectomy and midcarpal fusion can be performed using traditional fixation methods like K-wires, staples, screws or different dorsal (non)locking arthrodesis systems. The aim of this study is to test the Aptus four corner locking plate and to compare the clinical findings to the data revealed by CT scans and semi-automated segmentation.
Methods:
This is a retrospective review of eleven patients suffering from scapholunate advanced collapse (SLAC) or scaphoid non-union advanced collapse (SNAC) wrist, who received a four corner fusion between August 2011 and July 2014. The clinical evaluation consisted of measuring the range of motion (ROM), strength and pain on a visual analogue scale (VAS). Additionally, the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and the Mayo Wrist Score were assessed. A computerized tomography (CT) of the wrist was obtained six weeks postoperatively. After semi-automated segmentation of the CT scans, the models were post processed and surveyed.
Results
During the six-month follow-up mean range of motion (ROM) of the operated wrist was 60°, consisting of 30° extension and 30° flexion. While pain levels decreased significantly, 54% of grip strength and 89% of pinch strength were preserved compared to the contralateral healthy wrist. Union could be detected in all CT scans of the wrist. While X-ray pictures obtained postoperatively revealed no pathology, two user related technical complications were found through the 3D analysis, which correlated to the clinical outcome.
Conclusion
Due to semi-automated segmentation and 3D analysis it has been proved that the plate design can keep up to the manufacturers’ promises. Over all, this case series confirmed that the plate can compete with the coexisting techniques concerning clinical outcome, union and complication rate.
The Impact of Semi-Automated Segmentation and 3D Analysis on Testing New Osteosynthesis Material
(2017)
A new protocol for testing osteosynthesis material postoperatively combining semi-automated segmentation and 3D analysis of surface meshes is proposed. By various steps of transformation and measuring, objective data can be collected. In this study the specifications of a locking plate used for mediocarpal arthrodesis of the wrist were examined. The results show, that union of the lunate, triquetrum, hamate and capitate was achieved and that the plate is comparable to coexisting arthrodesis systems. Additionally, it was shown, that the complications detected correlate to the clinical outcome. In synopsis, this protocol is considered beneficial and should be taken into account in further studies.