- peer-reviewed (8)
In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis.
Operational wear behaviour of 3D-printed lightweight metal gears: EDS and oil analysis comparison
(2024)
Additive manufacturing (AM) has come to the fore in recent years among manufacturing techniques. This technique, which has different advantages than traditional ones such as casting, forging and machining, is expected to be widely used in producing machine parts like gears in the coming years. Therefore, experimental data on AM parameters for lightweight metal gears are important for industrial production. In this study, a wear test was applied to AlSi10Mg and Ti6Al4V gears under operational conditions, and the wear behaviour of conventionally and additively manufactured gears was compared. The amount of abrasion elements was determined by analysing the oil in the gearbox. In addition, gear surfaces were analysed using scanning electron microscopy and an energy-dispersive spectrometer before and after wear. Thus, the wear behaviour of gears produced by conventional and AM under service conditions was demonstrated comparatively.
Polyetheretherketone is a promising material for implants due to its good mechanical prop-
erties and excellent biocompatibility. Its accessibility to a wide range of applications is facilitated by the ability to process it with an easy-to-use manufacturing process such as fused filament fabrication. The elimination of disadvantages associated with the manufacturing process, such as a poor surface quality, is a main challenge to deal with. As part of the mass finishing process, centrifugal disc finishing has demonstrated good results in surface optimization, making it a promising candidate for the post-processing of additively manufactured parts. The objective of this study is to identify the key parameters of the centrifugal disc finishing process on the waviness of additively manufactured PEEK specimens, which has not been investigated previously. The waviness of the specimen was
investigated by means of confocal laser scanning microscopy (CLSM), while weight loss was additionally tracked. Six parameters were investigated: type, amount and speed of media, use of compound, amount of water and time. Type of media, time and speed were found to significantly influence waviness reduction and weight loss. Surface electron microscopy images demonstrated the additional effects of deburring and corner rounding. Results on previous studies with specimens made of metal showed similar results. Further investigation is required to optimize waviness reduction and polish parts in a second post-processing step.
Although magnesium and its alloys are promising candidates as biodegradable implant materials, the tendency for localized corrosion mechanism in physiological environment limit their biomedical application. Electropolishing is an attractive strategy for improving the corrosion behaviour of metals, but it is still largely unexplored in magnesium materials. In this study, the characterization of electropolished surfaces of AM50 and pure magnesium was performed, focussing on their in vitro degradation behaviour in cell medium. Corrosion rates were evaluated using potentiodynamic polarisation. The surface morphology before and after the onset of corrosion was investigated by scanning electron microscopy and confocal laser scanning microscopy. The presented electropolishing process led to improved surface performances, observable by significantly lower corrosion rates (0.08 mm·year-1 in Dulbecco's modified Eagle's medium), lower arithmetical mean height (0.05 µm), lower water contact angle (25-35°) and lower micro hardness (35-50 HV 0.1) compared to mechanically and chemically treated surfaces. MgO/Mg(OH)2 could be detected on electropolished surfaces. The localized corrosion mode could be reduced, but not entirely prevented. Electropolishing shows great potential as post-treatment of magnesium-based components, but detailed tests of the long-term corrosion behaviour are an important area of future research.
Progress in additive manufacturing is leading to the emergence of new areas of application. Laser Powder Bed Fusion (L-PBF) is increasingly used for the development of metallic medical implants, but for high-risk implants like vascular support structures (stents), surface quality is critical to ensure successful implantation without harming the surrounding tissue and ensure the patients’ health. Therefore, enhancing the surface quality is crucial. Electropolishing is a method for removing surface roughness by smoothing out micro-peaks and valleys. However, L-PBF structures have a high surface roughness due to metal particles adhering on the surface. To achieve a smooth surface for additively manufactured implants like stents using electropolishing, the removal of these particles needs to be studied in more detail.
The objective of this study is to examine the electropolishing mechanism of 316L stainless steel samples additively manufactured through Laser Powder Bed Fusion (L-PBF). The main objective is to investigate the removal properties and surface characteristics during electropolishing. To achieve this, various surfaces were characterized for morphology and roughness during Hull cell experiments. Markings are utilized on the Hull cell sample surfaces to identify points of interest during quasi-in-situ measurements. The surfaces are then analyzed after multiple time steps, applying different currents to investigate particle dissolution. The surface characteristics are analyzed through scanning electron microscopy, and surface roughness is analyzed using laser scanning microscopy.
The results show that the electropolishing process preferentially removes the adhering particles present on the surface of the samples. Increasing the current density results in faster particle dissolution and a smoother surface (see Figure 1a and b). The mechanism of material removal of various surface features, as shown in Figure 1 (red circle, yellow arrow and red square), was assessed based on the experimental results of the surface structures seen on the SEM images. It was found that different surface features were removed during the experiment at different polishing times and current densities. The amount of charge flowed was found to correlate with surface morphology.
Based on the obtained results, various surface features (such as large adherent particles, agglomerates of smaller particles, and valleys) and their changes with increasing test duration and current density were observed by quasi-in situ analyses. A reduction in the diameter of round particles adhering to the surface was observed at both low and higher current densities (see Figure 1a red circle a). Increasing the polishing time resulted in leveling of both large particles and valleys (see Figure 1b red square). Also, dissolution of agglomerates of smaller particles occurred at different polishing times as a function of current density and polishing time (see Figure 1a yellow arrow) are observed.
Smoothed surface structures can be observed in regions with equivalent surface charge density (see Figure 2). As a result, comparable surface morphologies may appear at the same area charge density, irrespective of a specific current density. So, it may be adequate to only consider the amount of charge flowed to describe the electropolishing of additive materials.
In conclusion, comprehending the dissolution characteristics of particles on L-PBF surfaces is essential for attaining satisfactory surface finish in electropolishing. The results of this study offer valuable perspectives into the electropolishing mechanism of additively manufactured 316L stainless steel and can guide future investigations on surface finishing and polishing of additive manufactured implants like stents.
Figure 1
Titanium is used in many areas due to its excellent mechanical, biological and corrosion-resistant properties. Implants often have thin and filigree structures, providing an ideal application for laser fine cutting. In literature, the main focus is primarily on investigating and optimizing the parameters for titanium sheet thicknesses greater than 1 mm. Hence, in this study, the basic manufacturing parameters of laser power, cutting speed and laser pulsing of a 200 W modulated fibre laser are investigated for 0.15 mm thick titanium grade 2 sheets. A reproducible, continuous cut could be achieved using 90 W laserpower and 2 cutting-speed. Pulse pause variations between 85–335 μs in 50 μs steps and fixed
pulse duration of 50 μs show that a minimum kerf width of 23.4 μm, as well as a minimum cut edge roughness Rz of 3.59 μm, is achieved at the lowest pulse pause. An increase in roughness towards the laser exit side, independent of the laser pulse pause, was found and discussed. The results provide initial process parameters for cutting thin titanium sheets and thus provide the basis for further investigations, such as the influence of cutting gas pressure and composition on the cut edge.
Influence of carbon content on the formation of TiC at diffusion bonded titanium-steel interface
(2023)
Hot pressing of pure Ti and various carbon steels in a temperature range of 950 – 1050 °C creates an up to 9 μm thick compound layer of TiC at the Ti/ steel interface. The calculation of the activation energy for layer formation is 126.5 - 136.7 kJ/mol, independent of the steels carbon content. As the carbon content of the steel increases, the layer thickness also increases, which provides enormous potential for the surface modification of Ti/ Ti-alloys.
One of the fundamental challenges in L-PBF of filigree geometries, such as aortic stents used in biomedical applications, is the requirement for a robust yet easily removable support structure that allows each component to be successfully fabricated without distortion. To solve this challenge, an integrative experimental approach was attempted in the present study by identifying an optimal support structure design and an optimized support removal strategy for this design. The specimens were manufactured using four different support structure designs based on the geometry exposed to the laser beam during the L-PBF. Support removal procedures included sand blasting (SB), glass bead blasting (GB), and electrochemical polishing (ECP). The two best-performing designs (line and cross) were chosen due to shorter lead times and lower material consumption. As an additional factor that indicates a stable design, the breaking load requirement to remove the support structures was determined. A modified line support with a 145° included angle was shown to be the best support structure design in terms of breaking load, material consumption, and manufacturing time. All three procedures were used to ensure residue-free support removal for this modified line support design, with ECP proving to be the most effective.
Experimental investigations are conducted to quantify the influence of specimen thickness and orientation on the mechanical properties of selective laser melted stainless steel 316 L. The results indicate that the mechanical strength and ductility increase with increasing specimen thickness until a saturation value is reached from a specimen thickness of about 2 mm. Specimen orientation dependency is pronounced for thin specimens (<1.5 mm), whereas only small deviations in strength are observed for thicker specimens with orientations of 30°, 45° and 90° to build direction. The mechanical properties of the specimen orientation of 0° to build direction shows great deviation to the other orientations and the smallest overall strength. A reliable design of selective laser melted components should account for specimen thickness and orientation, e. g. by a correction factor. Furthermore, it is recommended to avoid loads vertical (90°) and parallel (0°) to build direction to guarantee higher ductility and strength.