Refine
Year of publication
Document Type
- Article (18)
- conference proceeding (article) (5)
- Part of a Book (4)
- conference proceeding (presentation, abstract) (2)
- Preprint (2)
- Book (1)
Is part of the Bibliography
- no (32)
Keywords
- AlSi10Mg (1)
- Aluminum Alloys (1)
- Deep Rolling (1)
- Deep rolling (1)
- Deformation (1)
- Diffusion layers (1)
- EBSD (1)
- Electron backscatter diffraction (1)
- Elevated temperature behavior (1)
- Fatigue (1)
Institute
- Fakultät Maschinenbau (32)
- Labor Werkstoffrandschichtanalytik (29)
- Technologie-Campus Parsberg-Lupburg (11)
- Labor Medizinprodukte (4)
- Research Center of Biomedical Engineering - RCBE (4)
- Research Center of Health Sciences and Technology - RCHST (4)
- Computational Mechanics and Materials Lab (CMM) (2)
- Technologie-Campus Neustadt an der Donau (2)
Begutachtungsstatus
- peer-reviewed (11)
Experimental investigations are conducted to quantify the influence of specimen thickness and orientation on the mechanical properties of selective laser melted stainless steel 316 L. The results indicate that the mechanical strength and ductility increase with increasing specimen thickness until a saturation value is reached from a specimen thickness of about 2 mm. Specimen orientation dependency is pronounced for thin specimens (<1.5 mm), whereas only small deviations in strength are observed for thicker specimens with orientations of 30°, 45° and 90° to build direction. The mechanical properties of the specimen orientation of 0° to build direction shows great deviation to the other orientations and the smallest overall strength. A reliable design of selective laser melted components should account for specimen thickness and orientation, e. g. by a correction factor. Furthermore, it is recommended to avoid loads vertical (90°) and parallel (0°) to build direction to guarantee higher ductility and strength.
Advances in additive manufacturing enable the production of tailored lattice structures and thus, in principle, coronary stents. This study investigates the effects of process-related irregularities, heat and surface treatment on the morphology, mechanical response, and expansion behavior of 316L stainless steel stents produced by laser powder bed fusion and provides a methodological approach for their numerical evaluation. A combined experimental and computational framework is used, based on both actual and computationally reconstructed laser powder bed fused stents. Process-related morphological deviations between the as-designed and actual laser powder bed fused stents were observed, resulting in a diameter increase by a factor of 2-2.6 for the stents without surface treatment and 1.3-2 for the electropolished stent compared to the as-designed stent. Thus, due to the increased geometrically induced stiffness, the laser powder bed fused stents in the as-built (7.11 ± 0.63 N) or the heat treated condition (5.87 ± 0.49 N) showed increased radial forces when compressed between two plates. After electropolishing, the heat treated stents exhibited radial forces (2.38 ± 0.23 N) comparable to conventional metallic stents. The laser powder bed fused stents were further affected by the size effect, resulting in a reduced yield strength by 41% in the as-built and by 59% in the heat treated condition compared to the bulk material obtained from tensile tests. The presented numerical approach was successful in predicting the macroscopic mechanical response of the stents under compression. During deformation, increased stiffness and local stress concentration were observed within the laser powder bed fused stents. Subsequent numerical expansion analysis of the derived stent models within a previously verified numerical model of stent expansion showed that electropolished and heat treated laser powder bed fused stents can exhibit comparable expansion behavior to conventional stents. The findings from this work motivate future experimental/numerical studies to quantify threshold values of critical geometric irregularities, which could be used to establish design guidelines for laser powder bed fused stents/lattice structures.
One of the fundamental challenges in L-PBF of filigree geometries, such as aortic stents used in biomedical applications, is the requirement for a robust yet easily removable support structure that allows each component to be successfully fabricated without distortion. To solve this challenge, an integrative experimental approach was attempted in the present study by identifying an optimal support structure design and an optimized support removal strategy for this design. The specimens were manufactured using four different support structure designs based on the geometry exposed to the laser beam during the L-PBF. Support removal procedures included sand blasting (SB), glass bead blasting (GB), and electrochemical polishing (ECP). The two best-performing designs (line and cross) were chosen due to shorter lead times and lower material consumption. As an additional factor that indicates a stable design, the breaking load requirement to remove the support structures was determined. A modified line support with a 145° included angle was shown to be the best support structure design in terms of breaking load, material consumption, and manufacturing time. All three procedures were used to ensure residue-free support removal for this modified line support design, with ECP proving to be the most effective.
Influence of carbon content on the formation of TiC at diffusion bonded titanium-steel interface
(2023)
Hot pressing of pure Ti and various carbon steels in a temperature range of 950 – 1050 °C creates an up to 9 μm thick compound layer of TiC at the Ti/ steel interface. The calculation of the activation energy for layer formation is 126.5 - 136.7 kJ/mol, independent of the steels carbon content. As the carbon content of the steel increases, the layer thickness also increases, which provides enormous potential for the surface modification of Ti/ Ti-alloys.
Mechanical surface treatments such as deep rolling or laser-shock peening can markedly affect the cyclic performance of light-weight alloys, especially if significant thick work hardened surface regions are induced. At room temperature, the cyclic deformation behaviour is strongly influenced by the nature of the induced near-surface microstructures provided that they remain stable during fatigue loading. At elevated temperatures, the stability of near-surface work hardening and local microstructures plays an even more important role since the process-induced residual compressive stresses are likely to anneal out partially or completely. This overview illustrates to what extent deep rolling can effect the cyclic performance of various wrought light alloys being fatigue loaded in stress control at ambient and elevated temperatures.
Kombinationen aus kraft- und formschlüssigen Verbindungen erhöhen die Leistung bei im Hybridguss verbundenen Gussteilen mit Anbau- oder Einlegeteilen und machen separate Fügeprozesse überflüssig. Simulations-Methoden unterstützen das Design kraft- und formschlüssiger Verbindungen. Ergebnisse eines Ausdrückversuchs zeigen eine relativ gute Übereinstimmung zwischen gemessenen und mittels Simulation ermittelten Kraft-Weg-Kurven.
Several specimens of AZ31 magnesium alloy were taken in different directions from a rolled plate and subjected to tensile, compressive and four-point bending tests. Tensile and compressive tests allowed to characterize the mechanical properties of the material in the rolling and cross rolling directions. The bending tests were carried out in four different specimen types to take the effect of the anisotropy induced by the rolling procedure itself into account. Six strain gages per specimen allowed to observe the evolution of the strain with the bending moment during the tests. All bending specimens were bent until a total compressive deformation of 2.5 %. It was observed that the corresponding tensile strain was significant lower and slightly different for each specimen type. In addition, a characteristic non-uniform distribution of deformation twinning was observed. The induced residual stresses after bending were characterized by X-ray diffraction (XRD) and incremental hole-drilling (IHD). Due to the different mechanical behavior in tension and compression, an asymmetric residual stress distribution after bending could be observed. The neutral axis was, in all cases, shifted towards the tensile side. This observation agrees with the strain measurements during bending tests.
Effects of Deep Rolling on the Fatigue Behavior of Ti-6Al-4V at Ambient and Elevated Temperatures
(2003)
Mechanical surface treatments, such as deep rolling, shot peening and laser shock peening, can significantly improve the fatigue behavior of highly stressed metallic components. Deep rolling is an especially attractive technique since it is possible to generate deep, near-surface compressive residual stresses and work hardening while retaining a relatively smooth surface finish. Indeed, this technique is best known for increasing the fatigue strength and lifetime of steel components such as crankshafts. Although most work on deep rolling has been on steels, recently it has also been applied with reasonable success to titanium alloys. Accordingly, in this investigation, we examine the effect of deep rolling on the high-cycle fatigue behavior of Ti-6Al-4V, with particular emphasis on the thermal and mechanical stability of the residual stress states and near-surface microstructures. Preliminary results on laser shock peened Ti-6Al-4V are also presented for comparison. In addition, we examine whether these surface treatments are effective in retaining fatigue strength at the higher temperatures of 300 to 450C. Based on the cyclic deformation and stress/life behavior, together with the X-ray and microstructural observations, it is found that deep rolling can be quite effective in retarding the initiation and initial propagation of fatigue cracks in Ti-6Al-4V at such higher temperatures, despite the almost complete relaxation of the residual stresses at the surface. This clearly implies that, in addition to residual stresses, near-surface microstructures, which in Ti-6Al-4V consist of ultrafine near-surface nanostructures, play a critical role in the enhancement of fatigue lifetimes by mechanical surface treatments.