Refine
Year of publication
Document Type
- Article (6)
- conference proceeding (article) (5)
- conference proceeding (presentation, abstract) (4)
- Part of Periodical (4)
- Report (2)
- Book (1)
- conference talk (1)
Is part of the Bibliography
- no (23)
Keywords
- Fernwärme (3)
- Wärmewende (2)
- ZFSV (2)
- Zeitweise fließfähige selbstverdichtende Verfüllbaustoffe (2)
- Baustoff (1)
- Berechnungsmodell (1)
- Bodenmechanik (1)
- COVID-19 (1)
- Catheter (1)
- Chitosan (1)
Institute
- Fakultät Bauingenieurwesen (10)
- Labor für Geotechnik (10)
- Research Center of Biomedical Engineering - RCBE (10)
- Fakultät Maschinenbau (8)
- Research Center of Health Sciences and Technology - RCHST (8)
- Hochschulleitung/Hochschulverwaltung (4)
- Zentrum für Forschung und Transfer (ZFT ab 2024; vorher: IAFW) (4)
- Labor Medizinprodukte (3)
- Research Center for Artificial Intelligence - RCAI (3)
- Research Center of Energy and Resources - RCER (3)
Begutachtungsstatus
- peer-reviewed (5)
- begutachtet (2)
Forschung 2018
(2018)
Forschungsbericht 2013
(2014)
Forschungsbericht 2016
(2016)
Das „Merkblatt für die Herstellung und Verwendung von zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen“ (M ZFSV), Ausgabe 2025, befasst sich mit der Herstellung und der Anwendung zeitweise fließfähiger, selbstverdichtender Verfüllbaustoffe (ZFSV) gemäß den „Zusätzlichen Technischen Vertragsbedingungen und Richtlinien für Erdarbeiten im Straßenbau“ (ZTV E-StB) (FGSV 599) beim Bau von Straßen und Verkehrsflächen. Für andere Bereiche des Bauwesens kann dieses Merkblatt ebenfalls angewendet werden.
Das M ZFSV enthält Qualitätsanforderungen für diese Baustoffe und Baustoffgemische. Die Anforderungen schließen die verschiedenen Anwendungsgebiete der Baustoffe und Baustoffgemische, die Herstellung, Lieferung und den Einbau sowie die Prüfungen und die Qualitätssicherung ein. Vorab wird ebenso auf Anwendungsgebiete und Planungsgrundsätze eingegangen. Ergänzt werden die umfangreichen Ausführungen durch mehrere Anhänge.
Forschungsbericht 2015
(2015)
Results of WICOVIR Gargle Pool PCR Testing in German Schools Based on the First 100,000 Tests
(2021)
Background:
Opening schools and keeping children safe from SARS-CoV-2 infections at the same time is urgently needed to protect children from direct and indirect consequences of the COVID-19 pandemic. To achieve this goal, a safe, efficient, and cost-effective SARS-CoV-2 testing system for schools in addition to standard hygiene measures is necessary.
Methods:
We implemented the screening WICOVIR concept for schools in the southeast of Germany, which is based on gargling at home, pooling of samples in schools, and assessment of SARS-CoV-2 by pool rRT-PCR, performed decentralized in numerous participating laboratories. Depooling was performed if pools were positive, and results were transmitted with software specifically developed for the project within a day. Here, we report the results after the first 13 weeks in the project.
Findings:
We developed and implemented the proof-of-concept test system within a pilot phase of 7 weeks based on almost 17,000 participants. After 6 weeks in the main phase of the project, we performed >100,000 tests in total, analyzed in 7,896 pools, identifying 19 cases in >100 participating schools. On average, positive children showed an individual CT value of 31 when identified in the pools. Up to 30 samples were pooled (mean 13) in general, based on school classes and attached school staff. All three participating laboratories detected positive samples reliably with their previously established rRT-PCR standard protocols. When self-administered antigen tests were performed concomitantly in positive cases, only one of these eight tests was positive, and when antigen tests performed after positive pool rRT-PCR results were already known were included, 3 out of 11 truly positive tests were also identified by antigen testing. After 3 weeks of repetitive WICOVIR testing twice weekly, the detection rate of positive children in that cohort decreased significantly from 0.042 to 0.012 (p = 0.008).
Interpretation:
Repeated gargle pool rRT-PCR testing can be implemented quickly in schools. It is an effective, valid, and well-received test system for schools, superior to antigen tests in sensitivity, acceptance, and costs.
A major challenge in cochlear implant (CI) therapy is postoperative inflammation, which can compromise long-term electrode function. Conventional interleukin-6 (IL-6) detection is challenging due to factors such as its inherent instability. In this study, we present a cost-effective detection strategy using epitope-specific molecularly imprinted polymer nanoparticles (nanoMIPs). These nanoMIPs enable sensitive detection of both IL-6 and its epitope, representing a scalable and economical alternative for inflammation monitoring. NanoMIPs were embedded in a biodegradable chitosan matrix and sprayed onto electrodes. To detect the biomarker, electrochemical impedance spectroscopy was used, a functionality which is already embedded in CI circuits. The sensors enabled reliable detection of IL-6 down to 29 pg/mL, which represents the lowest concentration investigated in this study, with improved sensitivity to the small epitope, as the larger protein causes higher impedance changes due to steric hindrance. Additionally, the sensors enabled concentration-dependent IL-6 detection in human perilymph samples down to 2 pg/mL, with higher signal responses for IL-6 relative to other perilymph components. Comparison with an immunoassay supported analytical accuracy and diagnostic relevance. The sensors were subsequently tested weekly for functionality over four weeks under physiological conditions, with nanoMIP:chitosan ratios of 1:6 and 1:8 being optimal for long-term monitoring. Moreover, the nanoMIPs have a diameter of 56 nm (a parameter that can influence physiological excretion) and cytotoxicity tests demonstrated their biocompatibility. This work presents an epitope-based nanoMIP sensor platform that overcomes economic and biochemical limitations of protein-based biosensors, enabling advanced, real-time self-monitoring CI systems for in-vivo inflammation tracking to reduce implant failure.
This project is funded by the German Research Foundation (DFG) under Germany's Excellence Strategysingle bondEXC2177/1-Project ID 390895286 (“Cluster of Excellence Hearing4All”). Funding was also provided by the Research Foundation Flanders (FWO) under the project name “Catheter-based sensors for the intestinal detection of molecular biomarkers in the context of functional bowel disorders” and the project ID G0A6821N. Additional funding was provided by the USDA National Institute of Food and Agriculture, AFRI project 2022–67,021-36,408 and project EP/W031590/2 from the Engineering and Physical Sciences Research Council.
Der wissenschaftliche Untersuchungsstand von Zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen (ZSFV) unter Zugabe von Zement und/ oder Bentonit sowie Wasser zu Grundmaterial ist gering. Die OTH Regensburg (OTH.R) untersucht im Forschungsvorhaben EnEff systematisch verschiedene ZFSV für den Einsatz im Infrastrukturbau, speziell Fernwärmeleitungen. Neben der dort hauptsächlich interessierenden Kontaktmechanik zu axialen Temperaturdehnungsbehinderung werden bodenmechanische Eigenschaften und deren Zeitabhängigkeit untersucht. Im Beitrag werden nach einer einführenden Charakterisierung von ZFSV und kurzen Darstellung der Bedeutung der Zugabe von Zement und Bentonit Ergebnisse von bodenmechanischen Untersuchungen in Abhängigkeit des Materialalters und teilweise in Referenz zum Grundmaterial (hier: Boden) vorgestellt. Im Weiteren werden zwei auf ZFSV adaptierte, zementbasierte Prognosemodelle zur Vorhersage der zeitlichen Entwicklung der Druckfestigkeit vorgestellt.
Die Verlegung von Kunststoffverbundmantelrohren (KMR) im Fernwärmeleitungsbau ausschließlich in zeitweise fließfähigen, selbstverdichtenden Verfüllbaustoffen (ZFSV) in der Leitungszone anstelle in Sand, ist weitgehend neu. Interesse an dieser Methode besteht aus technischer Sicht infolge höherer nachgewiesener Haltekräfte in Technikums- und Laborversuchen, die die Leitungsbewegungen reduzieren können. Es existiert jedoch noch kein praxistaugliches Berechnungsmodell bzw die Grundlagen hierfür. U.a. deswegen wird derzeit an der Ostbayerischen Technischen Hochschule Regensburg (OTH.R) das Forschungsvorhaben "EnEff: Wärme - Innovative Fernwärmeverteilung - Einsatz fließfähiger Verfüllbaustoffe zur KMR-Verlegung, Arbeitspaket Bodenmechanik" durchgeführt. Es wird im Referat der Unterschied der axialen Bettung von KMR in ZFSV und Sand anhand einer analytischen Lösung vorgestellt. Diese erlaubt die Berechnung von Verschiebungen und Normalkräften für das KMR für die Bettung in ZFSV erfolgt dies unter Verwendung der mittels eines neuartigen Versuchs(behalters) Re-SIST nun bestimmbaren bisher unbekannten Kontaktwiderstandsarbeitslinie zwischen ZFSV und PE. Zur Verdeutlichung der Unterschiede bei Sand- und ZFSV-Bettung werden Ergebnisse einer vergleichenden Berechnung an einer sonst identischen KMR-Leitung vorgestellt. Diese zeigen, dass in ZFSV die Verschiebungen geringer ausfallen und weniger Leitungslange in Bewegung ist, was sich mit Beobachtungen an einer Fernwärmeleitung in Ulm deckt. Die Ausführungen gelten für das erstmalige Warmgehen.