Refine
Year of publication
Document Type
- conference proceeding (article) (38)
- Article (25)
- Preprint (6)
- conference proceeding (presentation, abstract) (4)
- Part of Periodical (3)
- conference talk (2)
- Patent (2)
- Report (1)
Is part of the Bibliography
- no (81)
Keywords
- Photoacoustic spectroscopy (9)
- Acetone (3)
- Spektroskopie (3)
- UV-LED (3)
- acetone (3)
- Acetone breath analysis (2)
- Acetone detection (2)
- Atmospheric modeling (2)
- Breath analysis (2)
- Cross-sensitivities (2)
Institute
- Fakultät Angewandte Natur- und Kulturwissenschaften (77)
- Sensorik-Applikationszentrum (SappZ) (75)
- Research Center for Artificial Intelligence - RCAI (39)
- Fakultät Maschinenbau (7)
- Fakultät Elektro- und Informationstechnik (3)
- Hochschulleitung/Hochschulverwaltung (3)
- Labor Faserverbundtechnik (LFT) (3)
- Research Center of Biomedical Engineering - RCBE (3)
- Zentrum für Forschung und Transfer (ZFT ab 2024; vorher: IAFW) (3)
- Laboratory for Safe and Secure Systems (LAS3) (2)
Begutachtungsstatus
- peer-reviewed (24)
We describe the miniaturization of the Surface Plasmon Resonance (SPR) technology which mainly finds its applications in pharmaceutical screening and biotechnology so far. SPR spectroscopy is a label-free, non-destructive and highly sensitive measurement principle detecting changes in the refractive index in striking distance to a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. A promising feature which is included in the miniaturized system is the angle-dependent recording of the SPR signals without moving parts. Commercial SPR assays are mainly working with a small number of sensing spots. In contrast, the SPR imaging system shown here will allow to use an array of many sensing spots. In combination with chemical receptors designed as an artificial nose, the simultaneous detection of many analytes is envisioned for future applications.
We present a sensitive UV LED photoacoustic setup for the detection of gaseous acetone and discuss its applicability towards breath analysis. We investigated the performance of the sensor for low acetone concentrations down to 0.1 parts per million (ppmV). The influences of temperature, flow, pressure, optical power and LED duty cycle on the measured signal have been examined. To gain a better understanding of the different effects on the photoacoustic signal, correlation analysis was applied and feature importance was determined using a large measured dataset. Furthermore, the cross-sensitivities towards O2, CO2 and H2O have been studied extensively. Finally, the sensor’s performance to detect acetone between 0.1–1 ppmV within gas mixtures simulating breath exhale conditions has been investigated, too. With a limit of detection (LoD) of 12.5 parts per billion (ppbV) (3σ) measured under typical breath exhale gas mixture conditions, the sensor demonstrated a high potential for the application of acetone detection in human breath analysis.
The performance of a photoacoustic trace gas sensor for the detection of acetone in N2 and synthetic air is reported. The sensor system utilises an amplitude modulated UV LED. The light source has an emission maximum at 278 nm and a maximum CW output power of 300 mW according to the datasheet. Three different collimating and focusing approaches have been investigated to guide the highly divergent LED light into the acoustic resonator of the photoacoustic measurement cell. A 3D printed aluminium cell was designed to optimize light coupling by simultaneously minimizing the photoacoustic background signal generation. Hence, the diameter of the resonator was set to a comparable large diameter of 10 mm and the inner walls of the resonator were mirror polished. The additive manufacturing procedure allowed for integration of a spirally formed gas channel, enabling gas heating prior to detection. The sensor performance was investigated by measuring acetone in N2 and synthetic air at different concentrations. The UV LED current was set to 86 % of the maximum value according to the datasheet of the light source in order to increase the lifetime and thermal stability. An Allan-Werle deviation analysis validates a stable sensor performance. The limit of detection (LoD) was determined at a 3σ noise level with a 10 s lock-in amplifier time constant by sampling data points over 20 s with a data acquisition rate of 5 Hz. LoDs of 80.8 ppbV and 19.6 ppbV were obtained for acetone in N2 and synthetic air, respectively.
We describe how to build a homogeneous light source for Surface Plasmon Resonance Imaging (SPRi) which mainly finds its applications in pharmaceutical screening and biotechnology so far. SPR spectroscopy is a label-free, non-destructive and highly sensitive measurement principle for detecting changes in the refractive index in close vicinity of a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. Commercial SPR assays are mainly working with a small number of sensing spots. In contrast, the SPR imaging system shown here will allow the use of an array of many sensing spots. In combination with chemical receptors designed as an artificial nose or an electronic tongue, the simultaneous detection of many analytes is envisioned. So far, lasers or other inhomogeneous light sources were used to illuminate the sensing surface, which is decreasing the systems sensitivity. We show a compact ( 300mm2) homogeneous top hat profile. The combination of a high bit-resolution camera with our new light source enables a reflectivity based surface plasmon resonance imaging system with a high refractive index unit (RIU) resolution.
A digital dual-phase lock-in amplifier that is capable to run on a low-cost, low-power platform comprising a 16-bit fixed-point digital signal processor was developed. This is achieved by a set of optimised digital filters including an exponential averager to adjust the time constant of the overall filter. The reference frequency is generated using a direct digital synthesis source utilising angle decomposition with a resolution of 1 Hz. The digital lock-in algorithm is described and the performance of the algorithm is analysed. The experimental results show that the developed lock-in amplifier achieves similar performance to a commercially available lock-in amplifier.