Refine
Year of publication
Document Type
Is part of the Bibliography
- no (109)
Keywords
- BEHAVIOR (8)
- magnetoactive elastomer (8)
- magnetoactive elastomers (7)
- magnetoelectric effect (7)
- hysteresis (6)
- magnetostriction (6)
- MICROSTRUCTURE (5)
- Magneto-optics (5)
- composites (5)
- magnetorheological elastomer (5)
Institute
- Labor Intelligente Materialien und Strukturen (109) (remove)
Begutachtungsstatus
- peer-reviewed (81)
- begutachtet (1)
Es werden Herstellung und Charakterisierung eines faseroptischen Elementarsensors zur Temperaturmessung vorgestellt. Der Sensorkopf in Form eines Prismas aus Indiumphosphid nutzt die Temperaturabhängigkeit der Absorptionskante des Halbleitermaterials. Aufgrund der Abmessungen des Prismas im Grenzbereich von Feinmechanik zu Mikrosystemtechnik ist ein angepasstes Herstellungsverfahren notwendig.
Mechanism of subwavelength imaging with bilayered magnetic metamaterials: Theory and experiment
(2007)
We present a theoretical and experimental study of a bilayered metamaterial structure for subwavelength imaging of magnetic field. The simplest version of such a structure consists of one or two linear arrays of capacitively loaded split pipe resonators. Its subwavelength physics is governed by strongly anisotropic magnetic coupling between individual resonators and by propagation of magnetoinductive waves with wavelength much shorter than the wavelength of the electromagnetic radiation in free space. It is shown that magnetoinductive waves propagating in the lateral direction are undesirable because they spread the image. Good subwavelength imaging is achieved when, due to the strong interlayer coupling, a stop band in the vicinity of the resonant frequency appears in the dispersion characteristics. The imaging properties of the single and double lens are compared and it is shown that the double lens has a superior performance. Excellent agreement is obtained between experimental and theoretical results for the magnetic field in the image plane in the operation frequency range of 30–60 MHz. It is shown that the same mechanism is responsible for image formation using bilayered planar metamaterial structures and a design of such a lens comprising two planar layers with a total of 542 elements is provided. The conclusions are not restricted to the radio frequency region because the elements can be scaled down.
A theoretical and experimental study of magnetic metamaterials with unit cells containing two resonant elements is presented. The properties of these structures, consisting of split rings, are governed by strongly anisotropic magnetic coupling between individual elements. This coupling leads to propagation of slow magnetoinductive waves in the vicinity of the resonant frequency. The wavelength of magnetoinductive waves is much smaller than the free-space wavelength of the electromagnetic radiation. This opens up the possibility of manipulating the near field on a subwavelength scale. We develop a theoretical formulation for coupled chains of metamaterial elements allowing the tailoring of their guiding properties in the near field. In a comprehensive analysis modes of coupled waveguides supporting forward and/or backward waves are identified and the corresponding hybridization mechanisms for dispersion equations of magnetoinductive waves are determined. Analytical predictions are verified both experimentally and numerically on a variety of coupled waveguides. The approach can be employed for the design of near-field manipulating devices.
Stimuli responsive materials are key ingredients for any application that requires dynamically tunable or on-demand responses. In this work we report experimental and theoretical investigation of magnetic-field driven modifications of soft-magnetic elastomers whose surface was processed by laser ablation into lamellar microstructures that can be manipulated by a uniform magnetic field. We present a minimal hybrid model that elucidates the associated deflection process of the lamellae and explains the lamellar structure frustration in terms of dipolar magnetic forces arising from the neighbouring lamellae. We experimentally determine the magnitude of the deflection as a function of magnetic flux density and explore the dynamic response of lamellae to fast changes in a magnetic field. A relationship between the deflection of lamellae and modifications of the optical reflectance of the lamellar structures is resolved.
Evaluation of highly compliant magneto-active elastomers with colossal magnetorheological response
(2014)
Highly compliant elastomers with a shear storage modulus as low as 25 Pa are prepared using commercially available silicone, plasticizer, and tactile mutator silicone additive. They are used as matrix material for magneto-active elastomers (MAEs) with carbonyl iron contents between 0 and 85 wt %. In the absence of an external magnetic field, the storage modulus of MAEs based on two selected mixtures ranges between ~100 Pa and ~2000 Pa. Addition of a mutator to the matrix mixture results in a long post-cure period depending on the curing temperature and the initial mixture. In the presence of a magnetic field, the presented MAEs exhibit a strong magneto-induced change in storage modulus resulting in a colossal magnetorheological effect of >106 % which is ~30 times higher than previously reported values. The results are of interest in applications using such elastomers as cell substrates with magnetically tunable rigidity.
The surface dilational modulus is a crucial parameter for describing the rheological properties of aqueous surfactant solutions. These properties are important for many technological processes. The present paper describes a fully automated instrument based on the oscillating bubble technique. It works in the frequency range from 1 Hz to 500 Hz, where surfactant exchange dynamics governs the relaxation process. The originality of instrument design is the consistent combination of modern measurement technologies with advanced imaging and signal processing algorithms. Key steps on the way to reliable and precise measurements are the excitation of harmonic oscillation of the bubble, phase sensitive evaluation of the pressure response, adjustment and maintenance of the bubble shape to half sphere geometry for compensation of thermal drifts, contour tracing of the bubbles video images, removal of noise and artefacts within the image for improving the reliability of the measurement, and, in particular, a complex trigger scheme for the measurement of the oscillation amplitude, which may vary with frequency as a result of resonances. The corresponding automation and programming tasks are described in detail. Various programming strategies, such as the use of MATLAB (R) software and native C++ code are discussed. An advance in the measurement technique is demonstrated by a fully automated measurement. The instrument has the potential to mature into a standard technique in the fields of colloid and interface chemistry and provides a significant extension of the frequency range to established competing techniques and state-of-the-art devices based on the same measurement principle.
The surface dilational modulus is a crucial parameter for describing the rheological properties of aqueous surfactant solutions. These properties are important for many technological processes. The present paper describes a fully automated instrument based on the oscillating bubble technique. It works in the frequency range from 1 Hz to 500 Hz, where surfactant exchange dynamics governs the relaxation process. The originality of instrument design is the consistent combination of modern measurement technologies with advanced imaging and signal processing algorithms. Key steps on the way to reliable and precise measurements are the excitation of harmonic oscillation of the bubble, phase sensitive evaluation of the pressure response, adjustment and maintenance of the bubble shape to half sphere geometry for compensation of thermal drifts, contour tracing of the bubbles video images, removal of noise and artefacts within the image for improving the reliability of the measurement, and, in particular, a complex trigger scheme for the measurement of the oscillation amplitude, which may vary with frequency as a result of resonances. The corresponding automation and programming tasks are described in detail. Various programming strategies, such as the use of MATLAB® software and native C++ code are discussed. An advance in the measurement technique is demonstrated by a fully automated measurement. The instrument has the potential to mature into a standard technique in the fields of colloid and interface chemistry and provides a significant extension of the frequency range to established competing techniques and state-of-the-art devices based on the same measurement principle.
Magnetoactive elastomers (MAE) based on soft silicone matrices, filled with various proportions of large diameter ( approximately 50 mu m) iron and small diameter ( approximately 0.5 mu m) magnetite particles are synthesized. Their rheological behavior in homogeneous magnetic fields up to 600 mT is studied in detail. The addition of small magnetite particles facilitates fabrication of uniformly distributed magnetic elastomer composites by preventing aggregation and sedimentation of large particles during curing. It is shown that using the proposed bimodal filler particles it is possible to tailor various magnetorheological (MR) properties which can be useful for different target applications. In particular, either absolute or relative magnetorheological effects can be tuned. The value of the damping factor as well as the range of deformation amplitudes for the linear viscoelastic regime can be chosen. The interdependencies between different MR properties of bimodal MAEs are considered. The results are discussed in the model framework of particle network formation under the simultaneous influence of external magnetic fields and mechanical deformation.
Hysteresis in dynamic modulus, loss factor and normal forces of magnetoactive elastomers (MAEs) comprising various proportions of small (3-5 mu m) and large (50-60 mu m) ferromagnetic particles are experimentally studied using dynamic torsion performed at a fixed oscillation frequency in varying DC magnetic fields. It is shown that hysteresis is a characteristic feature of MAEs observed both under increasing/decreasing magnetic field strength and increasing/decreasing strain amplitude. This hysteresis is attributed to the specific rearrangement of the magnetic filler network under simultaneously applied magnetic field and shear deformation. Rheological properties of the magnetic filler network formed in the magnetic field and, therefore, the rheological properties of MAEs depend strongly on the filler composition and the magnetic field magnitude. Larger magnetic particles and higher magnetic fields provide stronger magnetic networks. Both factors result in the extension of the linear viscoelastic regime to larger strain amplitudes and lead to higher values of shear storage and loss moduli. It is found that the hysteresis width maximises at an intermediate magnetic field where it is attributed to the balance between elastic and magnetic particle interactions. This is apparently where the most significant restructuring of the magnetic network occurs. The hysteresis width decreases with increasing fraction of large particles in the magnetic filler. The loss factor grows significantly when the magnetic network is physically broken by large strains gamma > 1%. A huge (more than one order of magnitude) increase of normal force at maximum magnetic field strengths is observed. It is predicted that any physical quantity depending on the internal structuring of the magnetic filler should demonstrate hysteresis either with a changing magnetic field and constant deformation amplitude or under variable deformation in a constant magnetic field. (C) 2015 Elsevier Ltd. All rights reserved.