Refine
Year of publication
Document Type
Is part of the Bibliography
- no (38)
Keywords
- Field emitter arrays (5)
- Electron sources (4)
- Laser micromachining (3)
- Silicon (3)
- field emission (3)
- Micromechanical devices (2)
- Triodes (2)
- field emission imaging (2)
- ARRAYS (1)
- Apertures (1)
Institute
- Fakultät Angewandte Natur- und Kulturwissenschaften (37)
- Labor Mikrosensorik (34)
- Research Center of Biomedical Engineering - RCBE (2)
- Hochschulleitung/Hochschulverwaltung (1)
- Labor Intelligente Materialien und Strukturen (1)
- Research Center of Energy and Resources - RCER (1)
- Research Center of Health Sciences and Technology - RCHST (1)
- Zentrum für Forschung und Transfer (ZFT ab 2024; vorher: IAFW) (1)
Begutachtungsstatus
- peer-reviewed (34)
Forschung 2018
(2018)
In this paper we report on an improved measurement and analysis method for determining the emission current distribution of field emitter arrays with CMOS sensors. It can also be used for field emission arrays where not all surfaces of the emitters are at the same electrical potential (e.g. for p-doped Si tips, where a strong current saturation occurs). To demonstrate the functionality of this method, a n-doped field emission array was measured using a variable external series resistance. Brightness variations in emission spots were analyzed to re-calculate the known series resistances for comparison. The re-calculated value is in good agreement with the actual value of the resistance. This method offers a quantitative approach to assess internal voltage drop effects on field emission using optical readout
Der Beitrag gibt einen Überblick über zwei typische Bauformen für Elektronenquellen auf der Basis von Feldemission aus Silizium. Des Weiteren wird eine typische Trioden-Beschaltung solcher Elektronenquellen für hohe Elektronentransmission vorgestellt und dabei auf ihre Leistungsfähigkeit eingegangen.
A CMOS image sensor is utilized to determine the time- and spatially resolved distribution of the total electron emission current of a silicon field emission array. The sensor measures electron emission without the need for phosphorus screens or scintillators as converters. However, in initial experiments, rather low field emission currents of several hundreds of nanoamperes per emitter already damaged the sensor surface, which altered the systems’ signal response over the measurement time. In consequence, we coated the CMOS sensor surface with a Cu layer for surface protection. In contrast to the original insulating surface, Cu is an excellent current- and heat-conductor, which avoids lens charging by providing a conductive path for incident electrons and has an improved heat dissipation capability. Measurements using a segmented field emission cathode with four individually addressable tips demonstrate a consistent correlation between the emission current and the sensor signal of the metal-coated image sensor. Furthermore, the characterization of a field emission array showed that single tip emission currents of up to 12 μA per tip are measurable without discernible damage effects of the sensor’s surface.
We are continuously improving the performance of our field emission electron sources. In this work a geometrically optimized design of electron sources with silicon nanowire field emitters on pillars was fabricated. This new design increased the packing density of the emitters by using a hexagonal arrangement of the pillars and a pillar spacing of 40 µm. Benzocyclobutene was used as the insulator material for an integrated (Cr/Ni) extraction gate. A modified fabrication process for the field emitters further improved reproducibility and reliability. An emission current of about 0.4 mA was measured for 30 minutes at an extraction voltage of 250 V and an anode voltage of 500 V. Electron transmission through the gate reached almost 100%.
Field emitter arrays (FEAs) are a promising component for novel vacuum micro- and nanoelectronic devices, such as microwave power amplifiers or fast-switching X-ray sources. However, the interrelated mechanisms responsible for FEA degradation and failure are not fully understood. Therefore, we present a measurement method for quantitative observation of individual emission sites during integral operation using a low-cost, commercially available CMOS imaging sensor. The emission and degradation behavior of three differently doped FEAs is investigated in current-regulated operation. The measurements reveal that the limited current of the p-doped emitters leads to an activation of up to 55% of the individual tips in the array, while the activation of the n-type FEA stopped at around 30%. This enhanced activation results in a more continuous and uniform current distribution for the p-type FEA. An analysis of the individual emitter characteristics before and after a constant current measurement provides novel perspectives on degradation behavior. A burn-in process that trims the emitting tips to an integral current-specific ideal field enhancement factor is observed. In this process, blunt tips are sharpened while sharp tips are dulled, resulting in homogenization within the FEA. The methodology is described in detail, making it easily adaptable for other groups to apply in the further development of promising FEAs.
In this work, high-current field emission electron source chips were fabricated using laser-micromachining and MEMS technology. The resulting chips were combined with commercially available printed circuit boards (PCBs) to obtain a multichip electron source. By controlling the separate electron sources using an external current control circuit, we were able to divide the desired total current evenly across the individual chips deployed in the PCB-carrier. In consequence, we were able to show a decreased degradation due to the reduced current load per chip. First, a single electron source chip was measured without current regulation. A steady-state emission current of 1 mA with a high stability of ±1.3% at an extraction voltage of 250 V was observed. At this current level, a mean degradation slope of −0.7 μA/min with a nearly perfect transmission ratio of 99% ± 0.4% was determined. The measurements of a fully assembled multichip PCB-carrier electron source, using a current control circuit for regulation, showed that an even distribution of the desired total current led to a decreased degradation. This was determined by the increase in the required extraction voltage over time. For this purpose, two current levels were applied to the electron source chips of the PCB-carrier using an external current control circuit. First, 300 μA total current was evenly distributed among the individual electron source chips followed by the emission of 300 μA per electron source chip. This allows the observation of the influence of a distributed and nondistributed total current, carried by the electron source chips. Thereby, we obtained an increase in the mean degradation slope from +0.011 V/min (300 μA distributed) to +0.239 V/min (300 μA per chip), which is approximately 21 times higher. Moreover, our current control circuit improved the current stability to under 0.1% for both current levels, 300 μA distributed and 300 μA per chip.
The article presents the process of developing a silicon electron source designed for high-vacuum microelectromechanical system (HV MEMS) devices, i.e., MEMS electron microscope and MEMS x-ray source. Technological constraints and issues of such an electron source are explained. The transition from emitters made of carbon nanotubes to emitters made of pure silicon is described. Overall, the final electron source consists of a silicon tip emitter and a silicon gate electrode integrated on the same glass substrate. The source generates an electron beam without any carbon nanotube coverage. It generates a high and stable electron current and works after the final bonding process of an HV MEMS device.
CMOS image sensors are utilized to determine the time- and spatially-resolved distribution of the electron emission of silicon field emission arrays. During initial experiments, rather low field emission currents already visibly damaged the sensor surface, altering the system accuracy over the measurement time. Therefore, we coated the sensor surface with copper for protection. In contrast to the original insulating surface, the Cu coating provides a conductive surface for incident electrons and improves heat dissipation in addition. This prevents localized surface charges and surface damages which stabilize the system accuracy.