Refine
Year of publication
Document Type
- Article (12)
- Part of Periodical (6)
- Part of a Book (2)
- conference proceeding (article) (1)
- Moving Images (1)
Is part of the Bibliography
- no (22)
Keywords
- Hüftgelenkprothese (3)
- Forschung (2)
- Forschungsbericht (2)
- Gait analysis (2)
- THA (2)
- Adaptive clinical trial (1)
- AnyBody (1)
- Attitude of Health Personnel (1)
- Beweglichkeit (1)
- Bewegungsanalyse (1)
Institute
- Fakultät Maschinenbau (8)
- Regensburg Center of Biomedical Engineering - RCBE (8)
- Hochschulleitung/Hochschulverwaltung (6)
- Institut für Sozialforschung und Technikfolgenabschätzung (IST) (6)
- Labor Biomechanik (LBM) (6)
- Labor für Technikfolgenabschätzung und Angewandte Ethik (LaTe) (6)
- Institut für Angewandte Forschung und Wirtschaftskooperationen (IAFW) (5)
- Fakultät Informatik und Mathematik (4)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (2)
Begutachtungsstatus
- peer-reviewed (7)
- begutachtet (1)
This White Paper outlines how the ethical discourse on cybersecurity has developed in the scientific literature, which ethical issues gained interest, which value conflicts are discussed, and where the “blind spots” in the current ethical discourse on cybersecurity are located. The White Paper is based on an extensive literature with a focus on three reference domains with unique types of value conflicts: health, business/finance and national security. For each domain, a systematic literature search has been performed and the identified papers have been analysed using qualitative and quantitative methods. An important observation is that the ethics of cybersecurity not an established subject. In all domains, cybersecurity is recognized as being an instrumental value, not an end in itself, which opens up the possibility of trade-offs with different values in different spheres. The most prominent common theme is the existence of trade-offs and even conflicts between reasonable goals, for example between usability and security, accessibility and security, privacy and convenience. Other prominent common themes are the importance of cybersecurity to sustain trust (in institutions), and the harmful effect of any loss of control over data.
Different target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.In a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek's "safe zone" were evaluated regarding their impact on gait patterns and clinical outcome.Combined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek's "safe zone" did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.Standard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA.
Static pelvic tilt impacts functional cup position in total hip arthroplasty (THA). In the current study we investigated the effect of kinematic pelvic changes on cup position. In the course of a prospective controlled trial postoperative 3D-computed tomography (CT) and gait analysis before and 6 and 12 months after THA were obtained in 60 patients. Kinematic pelvic motion during gait was measured using Anybody Modeling System. By fusion with 3D-CT, the impact of kinematic pelvic tilt alterations on cup anteversion and inclination was calculated. Furthermore, risk factors correlating with high pelvic mobility were evaluated. During gait a high pelvic range of motion up to 15.6° exceeding 5° in 61.7% (37/60) of patients before THA was found. After surgery, the pelvis tilted posteriorly by a mean of 4.0 ± 6.6° (p < .001). The pelvic anteflexion led to a mean decrease of −1.9 ± 2.2° (p < .001) for cup inclination and −15.1 ± 6.1° (p < .001) for anteversion in relation to the anterior pelvic plane (APP). Kinematic pelvic changes resulted in a further change up to 2.3° for inclination and up to 12.3° for anteversion. In relation to the preoperative situation differences in postoperative cup position ranged from −4.4 to 4.6° for inclination and from −7.8 to 17.9° for anteversion, respectively. Female sex (p < .001) and normal body weight (p < .001) correlated with high alterations in pelvic tilt. Kinematic pelvic changes highly impact cup anteversion in THA. Surgeons using the APP as reference should aim for a higher anteversion of about 15° due to the functional anteflexion of the pelvis during gait.
Offset restoration in total hip arthroplasty (THA) is associated with postoperative range of motion (ROM) and gait kinematics. We aimed to research into the impact of high offset (HO) and standard stems on postoperative ROM. 121 patients received cementless THA through a minimally-invasive anterolateral approach. A 360° hip ROM analysis software calculated impingement-free hip movement based on postoperative 3D-CTs compared to ROM values necessary for activities of daily living (ADL). The same model was then run a second time after changing the stem geometry between standard and HO configuration with the implants in the same position. HO stems showed higher ROM for all directions between 4.6 and 8.9° (p < 0.001) compared with standard stems but with high interindividual variability. In the subgroup with HO stems for intraoperative offset restoration, the increase in ROM was even higher for all ROM directions with values between 6.1 and 14.4° (p < 0.001) compared to offset underrestoration with standard stems. Avoiding offset underrestoration resulted in a higher amount of patients of over 20% for each ROM direction that fulfilled the criteria for ADL (p < 0.001). In contrast, in patients with standard stems for offset restoration ROM did increase but not clinically relevant by offset overcorrection for all directions between 3.1 and 6.1° (p < 0.001). Offset overcorrection by replacing standard with HO stems improved ROM for ADL in a low number of patients below 10% (p > 0.03). Patient-individual restoration of offset is crucial for free ROM in THA. Both over and underrestoration of offset should be avoided.
Forschungsbericht 2017
(2017)
Die monetären Kosten, die jährlich weltweit durch Cyberattacken ent-stehen, wachsen stetig und bewegen sich in Dimensionen, die mit öffentlichen Haushalten ganzer Staaten verglichen werden können. Cyberattacken treffen Individuen, Unternehmen, öffentliche Einrichtun-gen, Behörden und Regierungen; sie treffen eine Infrastruktur, ohne die moderne Gesellschaften kaum mehr funktionieren. Doch die Gewähr-leistung von Cybersicherheit kann zu Zielkonflikten führen. Die Techno-logien zur Herstellung von Sicherheit und Resilienz dieser Infrastruktur sollten daher Gegenstand der Technikfolgenabschätzung sein.
A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints.
We aimed to investigate the relationship between postoperative leg length/offset (LL/OS) reconstruction and gait performance after total hip arthroplasty (THA). In the course of a prospective randomized controlled trial, 60 patients with unilateral hip arthrosis received cementless THA through a minimally-invasive anterolateral surgical approach. One year post-operatively, LL and global OS restoration were analyzed and compared to the contralateral hip on AP pelvic radiographs. The combined postoperative limb length/OS reconstruction of the operated hip was categorized as restored (within 5 mm) or non-restored (more than 5 mm reduction or more than 5 mm increment). The acetabular component inclination, anteversion and femoral component anteversion were evaluated using CT scans of the pelvis and the femur. 3D gait analysis of the lower extremity and patient related outcome measures (HHS, HOOS, EQ-5D) were obtained pre-operatively, six months and twelve months post-operatively by an observer blinded to radiographic results. Component position of cup and stem was comparable between the restored and non-restored group. Combined LL and OS restoration within 5 mm resulted in higher Froude number (p < 0.001), normalized walking speed (p < 0.001) and hip range-of-motion (ROM) (p = 0.004) during gait twelve months postoperatively, whereas gait symmetry was comparable regardless of LL and OS reconstruction at both examinations. Clinical scores did not show any relevant association between the accuracy of LL or OS reconstruction and gait six/twelve months after THA. In summary, postoperative LL/OS discrepancies larger than 5 mm relate to unphysiological gait kinematics within the first year after THA. DRKS00000739, German Clinical Trials Register.
We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated 'femur-first' total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated 'femur-first' group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups.
Forschungsbericht 2016
(2016)
Cybersecurity in health
(2019)
Purpose
Cybersecurity in healthcare has become an urgent matter in recent years due to various malicious attacks on hospitals and other parts of the healthcare infrastructure. The purpose of this paper is to provide an outline of how core values of the health systems, such as the principles of biomedical ethics, are in a supportive or conflicting relation to cybersecurity.
Design/methodology/approach
This paper claims that it is possible to map the desiderata relevant to cybersecurity onto the four principles of medical ethics, i.e. beneficence, non-maleficence, autonomy and justice, and explore value conflicts in that way.
Findings
With respect to the question of how these principles should be balanced, there are reasons to think that the priority of autonomy relative to beneficence and non-maleficence in contemporary medical ethics could be extended to value conflicts in health-related cybersecurity.
Research limitations/implications
However, the tension between autonomy and justice, which relates to the desideratum of usability of information and communication technology systems, cannot be ignored even if one assumes that respect for autonomy should take priority over other moral concerns.
Originality/value
In terms of value conflicts, most discussions in healthcare deal with the conflict of balancing efficiency and privacy given the sensible nature of health information. In this paper, the authors provide a broader and more detailed outline.
The progress of medical genetics leads to a significant increase in genetic knowledge and a vast expansion of genetic diagnostics. However, it is still unknown how these changes will be integrated into medical practice and how they will change patients' and healthy persons' perception and evaluation of genetic diagnoses and genetic knowledge. Therefore, we carried out a comprehensive questionnaire survey with more than 500 patients, clients seeking genetic counseling, health care staff, and healthy persons (N = 523). The questionnaire survey covered detailed questions on the value of genetic diagnoses for the different groups of study participants, the right to know or not to know genetic diagnoses, possible differences between genetic and other medical diagnoses, and the practical use and implications of genetic knowledge with a special focus on hereditary neuropsychiatric diseases. A huge majority of the participants (90.7%) stated to have a right to learn every aspect of her or his genetic make-up. Similarly, study participants showed high interest (81.8%) in incidental health care findings-independent of whether the diseases are treatable or not. One can derive from the data outcome that study participants did not follow the implications of a "genetic exceptionalism" and often considered genetic findings as equivalent in relation to other medical diagnoses.
Forschungsbericht 2012
(2012)
BMBF-Projektgruppe »Recht auf Nichtwissen": Projektleitung: Prof. Dr. iur. Gunnar Duttge; Co-Projektbeteiligte: Prof. Dr. med. Dr. h. c. Wolf-gang Engel und Prof. Dr. Barbara Zoll (Humangenetik); Prof. Dr. med. Thomas Schulze (Psych-iatrische Genetik); Prof. Dr. med. Wolfgang Poser (Psychiatrie); Prof. Dr. phil. Christian Lenk(Medizinethik); Koordinatorin: Dipl.-Jur. Alexandra K. Weber, MLE. Projektmitarbeiter: LauraFlatau, M.Sc, Debora Frommeld, M.A., Dipl.-Jur. Laila Houri, Dr. rer. nat. Dipl.-Psych. MarkusReitt, Mateja Smogavec, Dipl.-Jur. Xenia Tukuser. Projekthomepage: http://www . recht - auf -nichtwissen.uni-goettingen.de/
The growing complexity of the digital ecosystem in combination with increasing global risks has created the following dilemma. Overemphasizing cybersecurity may violate fundamental values
like equality, fairness, freedom, or privacy but neglecting cybersecurity could undermine citizens’ trust and confidence in the digital infrastructure as well as in policy makers and state authorities. In order to increase our understanding of this dilemma, this contribution aims to provide an overview on value conflicts in cybersecurity based on a systematic review on the ethical, legal and
technological literature on cybersecurity. It shall be emphasized that a focus on the opposition of cybersecurity vs. privacy is insufficient for understanding the ethical complexity of cybersecurity.
Cybersecurity is of capital importance in a world where economic and social processes increasingly rely on digital technology. Although the primary ethical motivation of cybersecurity is prevention of informational or physical harm, its enforcement can also entail conflicts with other moral values. This contribution provides an outline of value conflicts in cybersecurity based on a quantitative literature analysis and qualitative case studies. The aim is to demonstrate that the security-privacy-dichotomy—that still seems to dominate the ethics discourse based on our bibliometric analysis—is insufficient when discussing the ethical challenges of cybersecurity.
Furthermore, we want to sketch how the notion of contextual integrity could help to better understand and mitigate such value conflicts.
Forschung 2018
(2018)
Forschungsbericht 2013
(2014)
Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.