Refine
Year of publication
Document Type
Is part of the Bibliography
- no (53)
Keywords
- Frailty (6)
- OUTCOMES (6)
- COMPLICATIONS (5)
- Outcome (5)
- ARTHROPLASTY (4)
- HFRS (4)
- INDEX (4)
- NAVIGATION (4)
- TOTAL JOINT ARTHROPLASTY (4)
- Total hip arthroplasty (4)
Institute
- Fakultät Maschinenbau (33)
- Forschungsstelle für Orthopädie und Ergonomie (23)
- Research Center of Biomedical Engineering - RCBE (20)
- Research Center of Health Sciences and Technology - RCHST (17)
- Fakultät Informatik und Mathematik (12)
- Research Center for Artificial Intelligence - RCAI (12)
- Labor Biomechanik (LBM) (7)
- Hochschulleitung/Hochschulverwaltung (6)
- Institut für Sozialforschung und Technikfolgenabschätzung (IST) (6)
- Labor für Technikfolgenabschätzung und Angewandte Ethik (LaTe) (6)
Begutachtungsstatus
- peer-reviewed (37)
- begutachtet (1)
Forschungsbericht 2016
(2016)
Forschungsbericht 2015
(2015)
Forschung 2018
(2018)
A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints.
We aimed to investigate the relationship between postoperative leg length/offset (LL/OS) reconstruction and gait performance after total hip arthroplasty (THA). In the course of a prospective randomized controlled trial, 60 patients with unilateral hip arthrosis received cementless THA through a minimally-invasive anterolateral surgical approach. One year post-operatively, LL and global OS restoration were analyzed and compared to the contralateral hip on AP pelvic radiographs. The combined postoperative limb length/OS reconstruction of the operated hip was categorized as restored (within 5 mm) or non-restored (more than 5 mm reduction or more than 5 mm increment). The acetabular component inclination, anteversion and femoral component anteversion were evaluated using CT scans of the pelvis and the femur. 3D gait analysis of the lower extremity and patient related outcome measures (HHS, HOOS, EQ-5D) were obtained pre-operatively, six months and twelve months post-operatively by an observer blinded to radiographic results. Component position of cup and stem was comparable between the restored and non-restored group. Combined LL and OS restoration within 5 mm resulted in higher Froude number (p < 0.001), normalized walking speed (p < 0.001) and hip range-of-motion (ROM) (p = 0.004) during gait twelve months postoperatively, whereas gait symmetry was comparable regardless of LL and OS reconstruction at both examinations. Clinical scores did not show any relevant association between the accuracy of LL or OS reconstruction and gait six/twelve months after THA. In summary, postoperative LL/OS discrepancies larger than 5 mm relate to unphysiological gait kinematics within the first year after THA. DRKS00000739, German Clinical Trials Register.
We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated 'femur-first' total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated 'femur-first' group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups.
Different target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.In a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek's "safe zone" were evaluated regarding their impact on gait patterns and clinical outcome.Combined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek's "safe zone" did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.Standard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA.
Cybersecurity in health
(2019)
Purpose
Cybersecurity in healthcare has become an urgent matter in recent years due to various malicious attacks on hospitals and other parts of the healthcare infrastructure. The purpose of this paper is to provide an outline of how core values of the health systems, such as the principles of biomedical ethics, are in a supportive or conflicting relation to cybersecurity.
Design/methodology/approach
This paper claims that it is possible to map the desiderata relevant to cybersecurity onto the four principles of medical ethics, i.e. beneficence, non-maleficence, autonomy and justice, and explore value conflicts in that way.
Findings
With respect to the question of how these principles should be balanced, there are reasons to think that the priority of autonomy relative to beneficence and non-maleficence in contemporary medical ethics could be extended to value conflicts in health-related cybersecurity.
Research limitations/implications
However, the tension between autonomy and justice, which relates to the desideratum of usability of information and communication technology systems, cannot be ignored even if one assumes that respect for autonomy should take priority over other moral concerns.
Originality/value
In terms of value conflicts, most discussions in healthcare deal with the conflict of balancing efficiency and privacy given the sensible nature of health information. In this paper, the authors provide a broader and more detailed outline.