BACKGROUND:
This planning study compares different radiotherapy techniques for patients with pituitary adenoma, including flatness filter free mode (FFF), concerning plan quality and secondary malignancies for potentially young patients. The flatness filter has been described as main source of photon scatter.
MATERIAL AND METHODS:
Eleven patients with pituitary adenoma were included. An Elekta Synergy™ linac was used in the treatment planning system Oncentra® and for the measurements. 3D plans, IMRT, and VMAT plans and non-coplanar varieties were considered. The plan quality was evaluated regarding homogeneity, conformity, delivery time and dose to the organs at risk. The secondary malignancy risk was calculated from dose volume data and from measured dose to the periphery using different models for carcinoma and sarcoma risk.
RESULTS:
The homogeneity and conformity were nearly unchanged with and without flattening filter, neither was the delivery time found substantively different. VMAT plans were more homogenous, conformal and faster in delivery than IMRT plans. The secondary cancer risk was reduced with FFF both in the treated region and in the periphery. VMAT plans resulted in a higher secondary brain cancer risk than IMRT plans, but the risk for secondary peripheral cancer was reduced. Secondary sarcoma risk plays a minor role. No advantage was found for non-coplanar techniques. The FFF delivery times were not shortened due to additional monitor units needed and technical limitations. The risk for secondary brain cancer seems to depend on the irradiated volume. Secondary sarcoma risk is much smaller than carcinoma risk in accordance to the results of the atomic bomb survivors. The reduction of the peripheral dose and resulting secondary malignancy risk for FFF is statistically significant. However, it is negligible in comparison to the risk in the treated region.
CONCLUSION:
Treatments with FFF can reduce secondary malignancy risk while retaining similar quality as with flattening filter and should be preferred. VMAT plans show the best plan quality combined with lowest peripheral secondary malignancy risk, but highest level of second brain cancer risk. Taking this into account VMAT FFF seems the most advantageous technique for the treatment of pituitary adenomas with the given equipment.
Background:
The aim of the study was to compare the two irradiation modes with (FF) and without flattening filter (FFF) for three different treatment techniques for simultaneous integrated boost radiation therapy of patients with right sided breast cancer.
Methods:
An Elekta Synergy linac with Agility collimating device is used to simulate the treatment of 10 patients. Six plans were generated in Monaco 5.0 for each patient treating the whole breast and a simultaneous integrated boost (SIB) volume: intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and a tangential arc VMAT (tVMAT), each with and without flattening filter. Plan quality was assessed considering target coverage, sparing of the contralateral breast, the lungs, the heart and the normal tissue. All plans were verified by a 2D-ionisation-chamber-array and delivery times were measured and compared. The Wilcoxon test was used for statistical analysis with a significance level of 0.05.
Results:
Significantly best target coverage and homogeneity was achieved using VMAT FFF with V95% = (98.7 +/- 0.8) % and HI = (8.2 +/- 0.9) % for the SIB and V95% = (98.3 +/- 0.7) % for the PTV, whereas tVMAT showed significantly lowest doses to the contralateral organs at risk with a D-mean of (0.7 +/- 0.1) Gy for the contralateral lung, (1.0 +/- 0.2) Gy for the contralateral breast and (1.4 +/- 0.2) Gy for the heart. All plans passed the gamma evaluation with a mean passing rate of (99.2 +/- 0.8) %. Delivery times were significantly reduced for VMAT and tVMAT but increased for IMRT, when FFF was used. Lowest delivery times were observed for tVMAT FFF with (1:20 +/- 0:07) min.
Conclusion:
Balancing target coverage, OAR sparing and delivery time, VMAT FFF and tVMAT FFF are considered the preferable of the investigated treatment options in simultaneous integrated boost irradiation of right sided breast cancer for the combination of an Elekta Synergy linac with Agility and the treatment planning system Monaco 5.0.
Background
The aim of this study was to investigate if the flattening filter free mode (FFF) of a linear accelerator reduces the excess absolute risk (EAR) for second cancer as compared to the flat beam mode (FF) in simultaneous integrated boost (SIB) radiation therapy of right-sided breast cancer.
Patients and methods
Six plans were generated treating the whole breast to 50.4 Gy and a SIB volume to 63 Gy on CT data of 10 patients: intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and a tangential arc VMAT (tVMAT), each with flattening filter and without. The EAR was calculated for the contralateral breast and the lungs from dose-volume histograms (DVH) based on the linear-exponential, the plateau, and the full mechanistic dose-response model. Peripheral low-dose measurements were performed to compare the EAR in more distant regions as the thyroids and the uterus.
Results
FFF reduces the EAR significantly in the contralateral and peripheral organs for tVMAT and in the peripheral organs for VMAT. No reduction was found for IMRT. The lowest EAR for the contralateral breast and lung was achieved with tVMAT FFF, reducing the EAR by 25 % and 29 % as compared to tVMAT FF, and by 44 % to 58 % as compared to VMAT and IMRT in both irradiation modes. tVMAT FFF showed also the lowest peripheral dose corresponding to the lowest EAR in the thyroids and the uterus.
Conclusion
The use of FFF mode allows reducing the EAR significantly when tVMAT is used as the treatment technique. When second cancer risk is a major concern, tVMAT FFF is considered the preferred treatment option in SIB irradiation of right-sided breast cancer.
Purpose
The complexity of the treatment techniques IMRT (Intensity Modulated Radiation Therapy) and VMAT (Volumetric Modulated Arc Therapy) introduced the requirement of an individual plan verification. The latest development is 3D verification which allows evaluation in terms of 3D gamma values but also a judgment based on differences in dose distributions on individual patient CT data and in dose volume histograms. For a verification tool the error detection sensitivity is important. The purpose of this work is to evaluate the accuracy and the sensitivity of the gamma evaluation of the 3D verification software MobiusFx when a systematic error in one parameter is applied. The results are compared to an established 2D-measurement based method.
Methods
11 IMRT and 11 VMAT plans were selected as reference plans. For every reference plan a systematic offset of 1 mm, 2 mm and 3 mm in the same direction was applied to the Multi-Leaf-Collimator (MLC) positions. All plans were irradiated and verified simultaneously with MobiusFx and MatriXX Evolution 2D array measurement. For both verification systems the applied dose distributions were evaluated using the gamma method based on the reference plans. In MobiusFx additionally the MLC position errors were evaluated.
Results
Regarding the gamma evaluation results, MobiusFx and MatriXX Evolution 2D measurements have almost the same sensitivity: The gamma evaluation of both systems detected shifts of 1 mm in VMAT plans and shifts of 2 mm and larger in IMRT plans. The information of the MLC position error provided by MobiusFx allows further to detect errors down to a shift of 1 mm in IMRT plans, giving an advantage over the MatriXX measurement.
Conclusions
MobiusFx shows a high error detection sensitivity, comparable to MatriXX Evolution. Through the gamma calculation and the MLC position error it is possible to detect errors down to a shift in MLC positions of 1 mm. It is recommended to inspect all the above parameters during plan verification.
Pediatric patients suffering from ependymoma are usually treated with cranial or craniospinal three-dimensional (3D) conformal radiotherapy (3DCRT). Intensity-modulated techniques spare dose to the surrounding tissue, but the risk for second malignancies may be increased due to the increase in low-dose volume. The aim of this study is to investigate if the flattening filter free (FFF) mode allows reducing the risk for second malignancies compared to the mode with flattening filter (FF) for intensity-modulated techniques and to 3DCRT. A reduction of the risk would be advantageous for treating pediatric ependymoma. 3DCRT was compared to intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) with and without flattening filter. Dose-volume histograms (DVHs) were compared to evaluate the plan quality and used to calculate the excess absolute risk (EAR) to develop second cancer in the brain. Dose verification was performed with a two-dimensional (2D) ionization chamber array and the out-of-field dose was measured with an ionization chamber to determine the EAR in peripheral organs. Delivery times were measured. Both VMAT and IMRT achieved similar plan quality in terms of dose sparing in the OAR and higher PTV coverage as compared to 3DCRT. Peripheral dose in low-dose region, which is proportional to the EAR in organs located in this region, for example, gonads, bladder, or bowel, could be significantly reduced using FFF. The lowest peripheral EAR and lowest delivery times were hereby achieved with VMATFFF . The EAR calculated based on DVH in the brain could not be reduced using FFF mode. VMATFFF improved the target coverage and homogeneity and kept the dose in the OAR similar compared to 3DCRT. In addition, delivery times were significantly reduced using VMATFFF . Therefore, for radiotherapy of ependymoma patients, VMATFFF may be considered advantageous for the combination of Elekta Synergy linac and Oncentra External Beam planning system used in this study.
Men treated for localized prostate cancer by radiotherapy have often a remaining life span of 10 yr or more. Therefore, the risk for secondary malignancies should be taken into account. Plans for ten patients were evaluated which had been performed on an Oncentra (R) treatment planning system for a treatment with an Elekta Synergy (TM) linac with Agility (TM) head. The investigated techniques involved IMRT and VMTA with and without flattening filter. Different dose response models were applied for secondary carcinoma and sarcoma risk in the treated region and also in the periphery. As organs at risk we regarded for carcinoma risk urinary bladder, rectum, colon, esophagus, thyroid, and for sarcoma risk bone and soft tissue. The excess absolute risk (EAR) was found very similar in the treated region for both techniques (IMRT and VMAT) and also for both with and without flattening filter. The secondary sarcoma risk resulted about one magnitude smaller than the secondary carcinoma risk. The EAR to the peripheral organs was statistically significant reduced by application of the flattening filter free mode concerning the flattening filter as main source of scattered dose. Application of flattening filter free mode can thus support to reduce second malignancy risk for patients with localized prostate cancer.
Second cancer risk after radiation of localized prostate cancer with and without flattening filter
(2017)
Background and purpose:
Fast and reliable tumor localization is an important part of today's radiotherapy utilizing new delivery techniques. This proof-of-principle study demonstrates the use of a method called herein 'stochastic triangulation' for this purpose. Stochastic triangulation uses very short imaging arcs and a few projections.
Materials and methods:
A stochastic Maximum A Posteriori (MAP) estimator is proposed based on an uncertainty-driven model of the acquisition geometry and inter-/intra-fractional deformable anatomy. The application of this method was designed to use the available linac-mounted cone-beam computed tomography (CBCT) and/or electronic portal imaging devices (EPID) for the patient setup based on short imaging arcs. For the proof-of-principle clinical demonstration, the MAP estimator was applied to 5 CBCT scans of a prostate cancer patient with 2 implanted gold markers. Estimation was performed for several (18) very short imaging arcs of 5° with 10 projections resulting in 90 estimations.
Results:
Short-arc stochastic triangulation led to residual radial errors compared to manual inspection with a mean value of 1.4mm and a standard deviation of 0.9 mm (median 1.2mm, maximum 3.8mm) averaged over imaging directions all around the patient. Furthermore, abrupt intra-fractional motion of up to 10mm resulted in radial errors with a mean value of 1.8mm and a standard deviation of 1.1mm (median 1.5mm, maximum 5.6mm). Slow periodic intra-fractional motions in the range of 12 mm resulted in radial errors with a mean value of 1.8mm and a standard deviation of 1.1mm (median 1.6mm, maximum 4.7 mm).
Conclusion:
Based on this study, the proposed stochastic method is fast, robust and can be used for inter- as well as intra-fractional target localization using current CBCT units.
Purpose:
The authors present a stochastic framework for radiotherapy patient positioning directly utilizing radiographic projections. This framework is developed to be robust against anatomical nonrigid deformations and to cope with challenging imaging scenarios, involving only a few cone beam CT projections from short arcs.
Methods:
Specifically, a Bayesian estimator (BE) is explicitly derived for the given scanning geometry. This estimator is compared to reference methods such as chamfer matching (CM) and the minimization of the median absolute error adapted as tools of robust image processing and statistics. In order to show the performance of the stochastic short-arc patient positioning method, a CIRS IMRT thorax phantom study is presented with movable markers and the utilization of an Elekta Synergy® XVI system. Furthermore, a clinical prostate CBCT scan of a Varian® On-Board Imager® system is utilized to investigate the robustness of the method for large variations of image quality (anterior-posterior vs lateral views).
Results:
The results show that the BE shifts reduce the initial setup error of up to 3 cm down to 3 mm at maximum for an imaging arc as short as 10° while CM achieves residual errors of 7 mm at maximum only for arcs longer than 40°. Furthermore, the BE can compensate robustly for low image qualities using several low quality projections simultaneously.
Conclusions:
In conclusion, an estimation method for marker-based patient positioning for short imaging arcs is presented and shown to be robust and accurate for deformable anatomies.
Re-irradiation of spinal column metastases by IMRT: Impact of setup errors on the dose distribution
(2013)
Background
This study investigates the impact of an automated image guided patient setup correction on the dose distribution for ten patients with in-field IMRT re-irradiation of vertebral metastases.
Methods
10 patients with spinal column metastases who had previously been treated with 3D-conformal radiotherapy (3D-CRT) were simulated to have an in-field recurrence. IMRT plans were generated for treatment of the vertebrae sparing the spinal cord. The dose distributions were compared for a patient setup based on skin marks only and a Cone Beam CT (CBCT) based setup with translational and rotational couch corrections using an automatic robotic image guided couch top (Elekta - HexaPOD™ IGuide® - system). The biological equivalent dose (BED) was calculated to evaluate and rank the effects of the automatic setup correction for the dose distribution of CTV and spinal cord.
Results
The mean absolute value (± standard deviation) over all patients and fractions of the translational error is 6.1 mm (±4 mm) and 2.7° (±1.1 mm) for the rotational error. The dose coverage of the 95% isodose for the CTV is considerable decreased for the uncorrected table setup. This is associated with an increasing of the spinal cord dose above the tolerance dose.
Conclusions
An automatic image guided table correction ensures the delivery of accurate dose distribution and reduces the risk of radiation induced myelopathy.