Refine
Document Type
Language
- English (7)
Has Fulltext
- no (7)
Is part of the Bibliography
- no (7)
Keywords
Institute
Begutachtungsstatus
- peer-reviewed (7)
We demonstrate the control of wettability of non-structured and microstructured magnetoactive elastomers (MAEs) by magnetic field. The synthesized composite materials have a concentration of carbonyl iron particles of 75 wt.% (≈27 vol.%) and three different stiffnesses of the elastomer matrix. A new method of fabrication of MAE coatings on plastic substrates is presented, which allows one to enhance the response of the apparent contact angle to the magnetic field by exposing the particle-enriched side of MAEs to water. A magnetic field is not applied during crosslinking. The highest variation of the contact angle from (113 ± 1)° in zero field up to (156 ± 2)° at about 400 mT is achieved in the MAE sample with the softest matrix. Several lamellar and pillared MAE structures are fabricated by laser micromachining. The lateral dimension of surface structures is about 50 µm and the depth varies between 3 µm and 60 µm. A systematic investigation of the effects of parameters of laser processing (laser power and the number of passages of the laser beam) on the wetting behavior of these structures in the absence and presence of a magnetic field is performed. In particular, strong anisotropy of the wetting behavior of lamellar structures is observed. The results are qualitatively discussed in the framework of the Wenzel and Cassie-Baxter models. Finally, directions of further research on magnetically controlled wettability of microstructured MAE surfaces are outlined. The obtained results may be useful for the development of magnetically controlled smart surfaces for droplet-based microfluidics.
An effective method for on-demand control over the impact dynamics of droplets on a magnetoresponsive surface is reported. The surface is comprised of micrometer-sized lamellas from a magnetoactive elastomer on a copper substrate. The surface itself is fabricated using laser micromachining. The orientation of the lamellae is switched from edge-on (orthogonal to the surface) to face-on (parallel to the surface) by changing the direction of a moderate (<250 mT) magnetic field. This simple actuation technique can significantly change the critical velocities of droplet rebound, deposition, and splashing. Rebound and deposition regimes can be switched up to Weber number We < 13 ± 3, while deposition and splashing can be switched in the range of 32 < We < 52. Because a permanent magnet is used, no permanent power supply is required for maintaining the particular regime of droplet impact. The presented technology is highly flexible and enables selective fabrication and actuation of microstructures on complex devices. It has great potential for applications in soft robotics, microfluidics, and advanced thermal management.
It is shown that the advancing (ACA) and receding (RCA) contact angles of water on extremely soft (shear modulus of the order of 10 kPa) magnetoactive elastomer (MAE) films significantly depend on the applied magnetic field. The difference between these angles, known as the contact angle hysteresis, is examined. The roles of the filler concentration and material softness are elaborated. The highest change in the contact angle hysteresis (CAH) from 34° in the absence of magnetic field to 76° in a magnetic field of 0.4 T is achieved for the softest sample with the lowest mass fraction of iron particles (70 wt%). The dependence of the CAH on magnetization history (“magnetic hysteresis”) is observed. This magnetic hysteresis is clearly pronounced for the ACA and has little effect on the RCA. Magnetic field-induced changes of the surface roughness exhibit qualitatively the same hysteresis behavior with regard to the external magnetic field as the ACA. The results are promising for the development of smart surfaces for applications where the dynamic wetting has to be controlled.
Commercially available contact angle (CA) measuring devices usually do not allow for the application of magnetic fields to the sample under test. A setup for measuring the CA of liquids on magnetosensitive surfaces has been developed specifically for investigating the surfaces of magnetoactive elastomers (MAEs). The addition of a programmable linear stage, which moves a permanent magnet, allows for fine control of the magnetic field applied to the MAE without the need for large and power-consuming electromagnets. Paired with a custom control and evaluation software, this measurement setup operates semiautomatically, limiting operator error and increasing precision, speed, as well as repeatability of static and dynamic CA measurements for different magnetoactive materials. The software is equipped with robust droplet fitting algorithms to avoid experimental challenges arising with soft magnetoactive materials, such as the curling of sample edges or diffuse non-reflective surfaces. Several application examples on MAE surfaces, both processed and unprocessed, are presented.
Efficient transportation of droplets (∽10 ¹ ̶̶̶̶ 10 ² µl) and small solid objects (∽10 ¹ ̶ 10 ² mm ³ ) have important applications in many fields, such as microfluidics, lab‐on‐a‐chip devices, drug delivery, etc. A novel multifunctional surface consisting of a periodic array of micro‐lamellae from a soft magnetoactive elastomer (MAE) on a plastic substrate is reported for these purposes. The physical origin of the propulsion is the bending of soft magnetic lamellae in non‐uniform magnetic fields, which is also observed in uniform magnetic fields. The magnetoactive surface is fabricated using a facile and rapid method of laser ablation. The propulsion of items is realized using a four‐pole rotating magnet. This results in a cyclic lamellar fringe motion over the micro‐structured surface and brings an advantage of easy reciprocation of transport by rotation reversal. Two modes of object transportation are identified: “pushing” mode for precise control of droplet and solid positioning and “bouncing” mode for heavier solid objects transportation. A water droplet of 5 μl or a glass sphere with a 2.1 mm diameter can be moved at a maximum speed of 60 mm s ⁻¹ . The multifunctionality of the proposed mechatronic platform is demonstrated on the examples of selective solid‐liquid separation and droplet merging.
Stimuli responsive materials are key ingredients for any application that requires dynamically tunable or on-demand responses. In this work we report experimental and theoretical investigation of magnetic-field driven modifications of soft-magnetic elastomers whose surface was processed by laser ablation into lamellar microstructures that can be manipulated by a uniform magnetic field. We present a minimal hybrid model that elucidates the associated deflection process of the lamellae and explains the lamellar structure frustration in terms of dipolar magnetic forces arising from the neighbouring lamellae. We experimentally determine the magnitude of the deflection as a function of magnetic flux density and explore the dynamic response of lamellae to fast changes in a magnetic field. A relationship between the deflection of lamellae and modifications of the optical reflectance of the lamellar structures is resolved.
A novel method for controlling the rebound behavior of small balls made of Al2O3 with a radius of 2.381 mm is presented. It uses different types of micro-structured surfaces of soft magnetoactive elastomers. These surfaces were fabricated via laser micromachining and include fully ablated surfaces as well as micrometer-sized lamellas with a fixed width of 90 µm, height of 250 µm and three different gap sizes (15, 60 and 105 µm). The lamellas can change their orientation from edge-on to face-on configuration according to the direction of the external magnetic field from a permanent magnet. The orientation of the external magnetic field significantly influences the rebound behavior of the balls, from a coefficient of restitution e of to < 0.1. The highest relative change in the coefficient of restitution between zero field and face-on configuration of is observed for lamellas with a gap of 60 µm. Other characteristics of the ball rebound such as the penetration depth into an Magnetoactive elastomer and the maximum deceleration are investigated as well. The proposed method does not require a constant power supply due to the use of permanent magnets. It may find novel applications in the field of impact engineering.