Refine
Year of publication
- 2021 (5) (remove)
Document Type
Language
- English (5) (remove)
Is part of the Bibliography
- no (5)
Keywords
- effective thermal conductivity (2)
- Electrolysis (1)
- Glass Industry (1)
- Hydrogen (1)
- Oxyfuel (1)
- Power-to-Gas (1)
- angle-dependent total solar energy transmittance (1)
- experimental investigation (1)
- hydrogen storage (1)
- iron/iron oxide (1)
Institute
- Fakultät Maschinenbau (4)
- Labor Sorptionsprozesse (2)
- Fakultät Angewandte Natur- und Kulturwissenschaften (1)
- Fakultät Elektro- und Informationstechnik (1)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (1)
- Labor Bauphysik (1)
- Labor Elektrische Maschinen und Antriebstechnik (1)
Begutachtungsstatus
- peer-reviewed (4)
A numerical parameter sensitivity analysis of the design parameters of the recently published solar selective thermal insulation system (SATIS) has been carried out to enhance its thermal and optical properties. It turned out that the insulation properties of SATIS can be effectively improved by reducing the length of the glass closure element. Increasing the area share of the light conducting elements (LCEs) and decreasing their length-to-diameter (L/D) ratio were identified as key parameters in order to increase the solar gain. Two SATIS variants were compared with the same wall insulation without SATIS in a yearly energetic performance assessment. The SATIS variant with 10 mm length of the closure element, 44.2% area share of LCE, as well as front and rear diameters of 12 mm/9 mm shows an 11.8% lower transmission heat loss over the heating period than the wall insulation without SATIS. A new methodology was developed to enable the implementation of the computed solar gains of SATIS in 1D simulation tools. The result is a radiant heat flow map for integration as a heat source in 1D simulation models. A comparison between the 1D and 3D models of the inside wall heat fluxes showed an integral yearly agreement of 98%.
This work aims at investigating the reduction/oxidation (redox) reaction kinetics on iron oxide pellets under different operating conditions of thermochemical hydrogen storage. In order to reduce the iron oxide pellets (90% Fe2O3, 10% stabilizing cement), hydrogen (H2) is applied in different concentrations with nitrogen (N2), as a carrier gas, at temperatures between between 700 ∘C and 900 ∘C, thus simulating the charging phase. The discharge phase is triggered by the flow of a mixture out of steam (H2O) and N2 at different concentrations in the same temperature range, resulting in the oxidizing of the previously reduced pellets. All investigations were carried out in a thermo-gravimetric analyzer (TGA) with a flow rate of 250mL/min. To describe the obtained kinetic results, a simplified analytical model, based on the linear driving force model, was developed. The investigated iron oxide pellets showed a stable redox performance of 23.8% weight reduction/gain, which corresponds to a volumetric storage density of 2.8kWh/(L bulk), also after the 29 performed redox cycles. Recalling that there is no H2 stored during the storage phase but iron, the introduced hydrogen storage technology is deemed very promising for applications in urban areas as day-night or seasonal storage for green hydrogen.
A newly-developed solar active thermal insulation system (SATIS) is introduced with the main objective to accomplish a highly-dependent total solar transmittance on the irradiation angle. SATIS is also designed to obtain the maximum transmittance at a prescribed design irradiation angle and to reduce it remarkably at higher irradiation angles. A purely mineral thermal insulation plaster with micro hollow glass spheres is applied to manufacture the investigated SATIS prototype. Light-conducting elements (LCEs) have been introduced into SATIS and suitable closing elements have been applied. The SATIS prototype has been investigated both experimentally and numerically. It turned out that the contributions of conduction, radiation and convection to the effective thermal conductivity of SATIS, without the closing elements (49 mWmK), amount to 86.2%, 13.2% and 0.6%, respectively. The angle-dependent short-wave radiation exchange within the LCE has been investigated via ray tracing. At the incidence angle of 19% (design angle), 27% of the radiation within the LCE is absorbed by the absorber plate, resulting in measured and computed total solar energy transmittances of 11.2%/11.7%, respectively. For a typical summer irradiation angle of 60%, 98% of the incident radiation is absorbed by the surfaces at the entrance of the LCE. The corresponding total solar energy transmittance amounts to 2.9%.
A prototype of a thermal insulation system to offer high selectivity of the solar gain regarding the solar incidence angle (SATIS) was applied to a typical solid brick masonry for existing buildings in Germany. Light conducting elements (LCEs) inclined at 19 ° were incorporated in SATIS, which equals the average solar noon angle in southern Germany during winter. The entire wall construction was experimentally investigated in a differential climatic chamber test bench at four different irradiation angles according to a dynamic test procedure. In addition, a conventional wall construction (CWC) has been measured. At SATIS’ design angle of 19 °, the SATIS wall construction shows a solar gain (SG) of 394.5 Wh/m², while the SG of the CWC amounts to only 25.4 Wh/m². The validated transient model of the SATIS wall construction showed that, at the end of the irradiation period of the dynamic test procedure (8 h), the solar heat penetrates to a depth of 253 mm and 111 mm inside the 385 mm thick brick wall masonry at the irradiation angles of 19 ° and 50 °, respectively. During the same time, the stored solar energy at 50 ° amounts to only 24.4 % of that stored at 19 °.
Simulation and Techno-Economic Analysis of a Power-to-Hydrogen Process for Oxyfuel Glass Melting
(2021)
As an energy-intensive industry sector, the glass industry is strongly affected by the increasingly stringent climate protection targets. As established combustion-based production systems ensure high process stability and glass quality, an immediate switch to low greenhouse gas emission processes is difficult. To approach these challenges, this work investigates a step-by-step integration of a Power-to-Hydrogen concept into established oxyfuel glass melting processes using a simulation approach. This is complemented by a case study for economic analysis on a selected German glass industry site by simulating the power production of a nearby renewable energy park and subsequent optimization of the power-to-hydrogen plant performance and capacities. The results of this study indicate, that the proposed system can reduce specific carbon dioxide emissions by up to 60%, while increasing specific energy demand by a maximum of 25%. Investigations of the impact of altered combustion and furnace properties like adiabatic flame temperature (+25 °C), temperature efficiency (∆ξ = −0.003) and heat capacity flow ratio (∆zHL = −0.009) indicate that pure hydrogen-oxygen combustion has less impact on melting properties than assumed so far. Within the case study, high CO2 abatement costs of 295 €/t CO2-eq. were determined. This is mainly due to the insufficient performance of renewable energy sources. The correlations between process scaling and economic parameters presented in this study show promising potential for further economic optimization of the proposed energy system in the future.