Refine
Document Type
- Article (11)
- conference proceeding (article) (1)
Language
- English (12) (remove)
Is part of the Bibliography
- no (12)
Keywords
Institute
- Fakultät Maschinenbau (11)
- Labor Sorptionsprozesse (5)
- Fakultät Angewandte Natur- und Kulturwissenschaften (1)
- Fakultät Elektro- und Informationstechnik (1)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (1)
- Labor Bauphysik (1)
- Labor Elektrische Maschinen und Antriebstechnik (1)
- Labor Heizungs- und Klimatechnik (1)
Begutachtungsstatus
- peer-reviewed (10)
A prototype of a thermal insulation system to offer high selectivity of the solar gain regarding the solar incidence angle (SATIS) was applied to a typical solid brick masonry for existing buildings in Germany. Light conducting elements (LCEs) inclined at 19 ° were incorporated in SATIS, which equals the average solar noon angle in southern Germany during winter. The entire wall construction was experimentally investigated in a differential climatic chamber test bench at four different irradiation angles according to a dynamic test procedure. In addition, a conventional wall construction (CWC) has been measured. At SATIS’ design angle of 19 °, the SATIS wall construction shows a solar gain (SG) of 394.5 Wh/m², while the SG of the CWC amounts to only 25.4 Wh/m². The validated transient model of the SATIS wall construction showed that, at the end of the irradiation period of the dynamic test procedure (8 h), the solar heat penetrates to a depth of 253 mm and 111 mm inside the 385 mm thick brick wall masonry at the irradiation angles of 19 ° and 50 °, respectively. During the same time, the stored solar energy at 50 ° amounts to only 24.4 % of that stored at 19 °.
Simulation and Techno-Economic Analysis of a Power-to-Hydrogen Process for Oxyfuel Glass Melting
(2021)
As an energy-intensive industry sector, the glass industry is strongly affected by the increasingly stringent climate protection targets. As established combustion-based production systems ensure high process stability and glass quality, an immediate switch to low greenhouse gas emission processes is difficult. To approach these challenges, this work investigates a step-by-step integration of a Power-to-Hydrogen concept into established oxyfuel glass melting processes using a simulation approach. This is complemented by a case study for economic analysis on a selected German glass industry site by simulating the power production of a nearby renewable energy park and subsequent optimization of the power-to-hydrogen plant performance and capacities. The results of this study indicate, that the proposed system can reduce specific carbon dioxide emissions by up to 60%, while increasing specific energy demand by a maximum of 25%. Investigations of the impact of altered combustion and furnace properties like adiabatic flame temperature (+25 °C), temperature efficiency (∆ξ = −0.003) and heat capacity flow ratio (∆zHL = −0.009) indicate that pure hydrogen-oxygen combustion has less impact on melting properties than assumed so far. Within the case study, high CO2 abatement costs of 295 €/t CO2-eq. were determined. This is mainly due to the insufficient performance of renewable energy sources. The correlations between process scaling and economic parameters presented in this study show promising potential for further economic optimization of the proposed energy system in the future.
This work aims at investigating the kinetic mechanisms of the reduction/oxidation (redox) reactions of iron oxide/iron pellets under different operating conditions. The reaction principle is the basis of a thermochemical hydrogen storage system. To simulate the charging phase, a single pellet consisting of iron oxide (90% Fe2O3, 10% stabilising cement) is reduced with different hydrogen (H2) concentrations at temperatures between 600 and 800 °C. The discharge phase is initiated by the oxidation of the previously reduced pellet by water vapour (H2O) at different concentrations in the same temperature range. In both reactions, nitrogen (N2) is used as a carrier gas. The redox reactions have been experimentally measured in a thermogravimetric analyser (TGA) at a flow rate of 250 mL/min. An extensive literature review has been conducted on the existing reactions’ kinetic mechanisms along with their applicability to describe the obtained results. It turned out that the measured kinetic results can be excellently described with the so-called shrinking core model. Using the geometrical contracting sphere reaction mechanism model, the concentration- and temperature-dependent reduction and oxidation rates can be reproduced with a maximum deviation of less than 5%. In contrast to the reduction process, the temperature has a smaller effect on the oxidation reaction kinetics, which is attributed to 71% less activation energy (Ea,Re=56.9 kJ/mol versus Ea,Ox=16.0 kJ/mol). The concentration of the reacting gas showed, however, an opposite trend: namely, to have an almost twofold impact on the oxidation reaction rate constant compared to the reduction rate constant.
This work aims at investigating the reduction/oxidation (redox) reaction kinetics on iron oxide pellets under different operating conditions of thermochemical hydrogen storage. In order to reduce the iron oxide pellets (90% Fe2O3, 10% stabilizing cement), hydrogen (H2) is applied in different concentrations with nitrogen (N2), as a carrier gas, at temperatures between between 700 ∘C and 900 ∘C, thus simulating the charging phase. The discharge phase is triggered by the flow of a mixture out of steam (H2O) and N2 at different concentrations in the same temperature range, resulting in the oxidizing of the previously reduced pellets. All investigations were carried out in a thermo-gravimetric analyzer (TGA) with a flow rate of 250mL/min. To describe the obtained kinetic results, a simplified analytical model, based on the linear driving force model, was developed. The investigated iron oxide pellets showed a stable redox performance of 23.8% weight reduction/gain, which corresponds to a volumetric storage density of 2.8kWh/(L bulk), also after the 29 performed redox cycles. Recalling that there is no H2 stored during the storage phase but iron, the introduced hydrogen storage technology is deemed very promising for applications in urban areas as day-night or seasonal storage for green hydrogen.
An innovative adsorber plate heat exchanger (APHE), which is developed for application in adsorption heat pumps, chillers and thermal energy storage systems, is introduced. A test frame has been constructed as a representative segment of the introduced APHE for applying loose grains of AQSOA-Z02. Adsorption kinetic measurements have been carried out in a volumetric large-temperature-jump setup under typical operating conditions of adsorption processes. A transient 2-D model is developed for the tested sample inside the setup. The measured temporal uptake variations with time have been fed to the model, through which a micro-pore diffusion coefficient at infinite temperature of 2 E−4 [m2s−1] and an activation energy of 42.1 [kJ mol−1] have been estimated. A 3-D model is developed to simulate the combined heat and mass transfer inside the APHE and implemented in a commercial software. Comparing the obtained results with the literature values for an extruded aluminium adsorber heat exchanger coated with a 500 μm layer of the same adsorbent, the differential water uptake obtained after 300 s of adsorption (8.2 g/100 g) implies a sound enhancement of 310%. This result proves the great potential of the introduced APHE to remarkably enhance the performance of adsorption heat transformation appliances.
The effect of both heat and mass transfer characteristic lengths (HTCL, MTCL) of two different adsorber plate heat exchangers (APHE), for application in an adsorption chiller, on the adsorption and desorption kinetics is investigated. Three representative test frames (TF1-TF3) are prepared to examine small-scale adsorbent samples of the microporous silica gel (Siogel of Oker-Chemie, Germany) applying the volumetric large-temperature-jump methodology at different operating conditions. Based on the obtained kinetic data, an analytical model has been developed to predict the specific cooling power (SCP) and the coefficient of performance (COP) of a single-bed adsorption chiller comprising the studied APHEs. It turned out that, within the tested range of HTCL and MTCL, it can be concluded that, the adsorption kinetics are mainly influenced by the MTCL, while the desorption kinetics are dominated by the HTCL of the adsorbent domain. Applying Siogel as loose pellets inside a newly introduced APHE results in of 423.3 and 182.7 W⋅kg−1, at the evaporator temperatures of 15 °C and 5 °C, respectively. Herein, the condenser and adsorber-end temperatures amount to 30 °C and the desorption-end temperature to 90 °C. The corresponding s amount to 0.50 and 0.40, respectively, which represent quite promising results for further design optimizations.
This paper introduces the results of an experimental study on the adsorption and desorption kinetics of a commercially available, open-structured asymmetric plate heat exchanger adapted to act as an adsorber/desorber for the application in adsorption heat transformation processes. In addition, a volumetric large temperature jump (V-LTJ) kinetic setup was applied to measure the adsorption and desorption kinetics of a small-scale adsorbent sample prepared dedicatedly to be representative for the adsorbent domain inside the investigated adsorber plate heat exchanger (APHE). All kinetic results of the small-scale adsorbent sample and the APHE were fitted into exponential forms with a single characteristic time constant (τ) with a coefficient of determination (R2) better than 0.9531. A very good matching between the small-scale and full-scale adsorption kinetic measurements was obtained, with an average relative deviation of 12.3% in the obtained τ-values. In addition, the kinetic data of the small-scale adsorbent sample were utilized for estimating the expected specific instantaneous and moving average powers of the evaporator/condenser heat exchanger. The average relative deviation (ARD) between the moving average specific evaporator powers obtained from the small-scale and the full-scale measurements amounts between 5.4 and 15.1%.
This communication introduces an experimental setup for investigating the effect of solar radiation on the reduction of transmission heat losses and the steady state thermal conductance of uninsulated and insulated multi-layer wall samples. The setup consists of two adjacent climatic chambers, which share a common wall, in which the multi-layer wall samples are mounted. A solar simulator is applied within the outdoor air climatic chamber, whose radiation spectrum and radiation intensity are approximately equivalent to those of the sun. The first tests have been carried out on a wall sample with a typical structure of existing buildings from the year 1930 in Germany. In addition, a high-performance insulating plaster layer has been applied on a basic test sample (with existing building structure) to replicate and assess the refurbished scenario. Furthermore, a numerical investigation on the transient heat transfer process is carried out by using the simulation software COMSOL Multiphysics®. The experimental results of both uninsulated and insulated wall samples are validated against 1D and 3D models. As seen, the uninsulated wall, whose thermal conductance was experimentally determined to be equal to 1.79 W/(m²K), absorbs a heat flux of 208 W/m² through its external wall surface over a period of 8 hours. A fraction of 9.8 % of the absorbed heat arrives as a gain on the internal wall and reduces the transmission heat losses by 11.7 % over a period of 55 hours. On the other hand, the thermal conductivity of the insulation layer of the refurbished wall sample with micro hollow glass spheres was estimated by a parameter estimation procedure using the 3D model and the obtained experimental data. Using the estimated thermal conductivity, a thermal conductance of 0.42 W/(m²K) has been obtained for the refurbished wall sample.
A newly-developed solar active thermal insulation system (SATIS) is introduced with the main objective to accomplish a highly-dependent total solar transmittance on the irradiation angle. SATIS is also designed to obtain the maximum transmittance at a prescribed design irradiation angle and to reduce it remarkably at higher irradiation angles. A purely mineral thermal insulation plaster with micro hollow glass spheres is applied to manufacture the investigated SATIS prototype. Light-conducting elements (LCEs) have been introduced into SATIS and suitable closing elements have been applied. The SATIS prototype has been investigated both experimentally and numerically. It turned out that the contributions of conduction, radiation and convection to the effective thermal conductivity of SATIS, without the closing elements (49 mWmK), amount to 86.2%, 13.2% and 0.6%, respectively. The angle-dependent short-wave radiation exchange within the LCE has been investigated via ray tracing. At the incidence angle of 19% (design angle), 27% of the radiation within the LCE is absorbed by the absorber plate, resulting in measured and computed total solar energy transmittances of 11.2%/11.7%, respectively. For a typical summer irradiation angle of 60%, 98% of the incident radiation is absorbed by the surfaces at the entrance of the LCE. The corresponding total solar energy transmittance amounts to 2.9%.
This communication presents an experimental and analytical study on the evaporation mechanism in a closed-structured asymmetric plate heat exchanger (PHE) employed as a stagnant water evaporator for the application in an adsorption heat transformation appliance. To this aim, an experimental unit is constructed, which comprises two identical PHEs, one acting as an vaporator/condenser and the second, as an adsorber/desorber. Two endoscopes are mounted inside the investigated evaporator to visualize the evaporation mechanism when performing adsorption-evaporation processes under different boundary conditions. It turned out that the evaporation mechanism is a partially covered, thin film evaporation. A heat transfer analysis is performed to evaluate the heat transfer coefficient of the thin film evaporation () inside the investigated evaporator, resulting in -values between 1330 and 160 [W∙m−2∙K−1] over the investigated adsorption-evaporation time. Correlating the obtained () to the film thickness and the wetted area results in -values between 0.34 and 0.78 [mm] and wetted to total area ratios of 0.78 to 0.16. Besides, an analytical model has been developed and introduced to correlate the overall evaporator heat transfer coefficient with the adsorption potential and the time rate of change of the water uptake.