Refine
Year of publication
Document Type
- Article (18)
- conference proceeding (article) (3)
- Part of a Book (1)
Has Fulltext
- no (22)
Is part of the Bibliography
- no (22)
Keywords
- limited angle tomography (4)
- Fourier integral operators (3)
- computed tomography (3)
- microlocal analysis (3)
- Curvelets (2)
- Dimensionality reduction (2)
- IMAGE-RECONSTRUCTION (2)
- Lambda tomography (2)
- Radon transform (2)
- Sparse regularization (2)
Institute
Begutachtungsstatus
- peer-reviewed (22) (remove)
We study the limited data problem of the spherical Radon transform in two and three-dimensional spaces with general acquisition surfaces. In such situations, it is known that the application of filtered-backprojection reconstruction formulas might generate added artifacts and degrade the quality of reconstructions. In this article, we explicitly analyze a family of such inversion formulas, depending on a smoothing function that vanishes to order k on the boundary of the acquisition surfaces. We show that the artifacts are k orders smoother than their generating singularity. Moreover, in two-dimensional space, if the generating singularity is conormal satisfying a generic condition then the artifacts are even k+1/2 orders smoother than the generating singularity. Our analysis for three-dimensional space contains an important idea of lifting up space. We also explore the theoretical findings in a series of numerical experiments. Our experiments show that a good choice of the smoothing function leads to a significant improvement of reconstruction quality.
This article provides a mathematical analysis of singular (nonsmooth) artifacts added to reconstructions by filtered backprojection (FBP) type algorithms for X-ray computed tomography (CT) with arbitrary incomplete data. We prove that these singular artifacts arise from points at the boundary of the data set. Our results show that, depending on the geometry of this boundary, two types of artifacts can arise: object-dependent and object-independent artifacts. Object-dependent artifacts are generated by singularities of the object being scanned, and these artifacts can extend along lines. They generalize the streak artifacts observed in limited-angle tomography. Object-independent artifacts, on the other hand, are essentially independent of the object and take one of two forms: streaks on lines if the boundary of the data set is not smooth at a point and curved artifacts if the boundary is smooth locally. We prove that these streak and curve artifacts are the only singular artifacts that can occur for FBP in the continuous case. In addition to the geometric description of artifacts, the article provides characterizations of their strength in Sobolev scale in certain cases. The results of this article apply to the well-known incomplete data problems, including limited-angle and regionof-interest tomography, as well as to unconventional X-ray CT imaging setups that arise in new practical applications. Reconstructions from simulated and real data are analyzed to illustrate our theorems, including the reconstruction that motivated this work a synchrotron data set in which artifacts appear on lines that have no relation to the object.
Reduction of variable-truncation artifacts from beam occlusion during in situ x-ray tomography
(2017)
Many in situ x-ray tomography studies require experimental rigs which may partially occlude the beam and cause parts of the projection data to be missing. In a study of fluid flow in porous chalk using a percolation cell with four metal bars drastic streak artifacts arise in the filtered backprojection (FBP) reconstruction at certain orientations. Projections with non-trivial variable truncation caused by the metal bars are the source of these variable-truncation artifacts. To understand the artifacts a mathematical model of variable-truncation data as a function of metal bar radius and distance to sample is derived and verified numerically and with experimental data. The model accurately describes the arising variable-truncation artifacts across simulated variations of the experimental setup. Three variable-truncation artifact-reduction methods are proposed, all aimed at addressing sinogram discontinuities that are shown to be the source of the streaks. The 'reduction to limited angle' (RLA) method simply keeps only non-truncated projections; the 'detector-directed smoothing' (DDS) method smooths the discontinuities; while the 'reflexive boundary condition' (RBC) method enforces a zero derivative at the discontinuities. Experimental results using both simulated and real data show that the proposed methods effectively reduce variable- truncation artifacts. The RBC method is found to provide the best artifact reduction and preservation of image features using both visual and quantitative assessment. The analysis and artifact-reduction methods are designed in context of FBP reconstruction motivated by computational efficiency practical for large, real synchrotron data. While a specific variable- truncation case is considered, the proposed methods can be applied to general data cut-offs arising in different in situ x-ray tomography experiments.
We derive a new 3D model for magnetic particle imaging (MPI) that is able to incorporate realistic magnetic fields in the reconstruction process. In real MPI scanners, the generated magnetic fields have distortions that lead to deformed magnetic low-field volumes with the shapes of ellipsoids or bananas instead of ideal field-free points (FFP) or lines (FFL), respectively. Most of the common model-based reconstruction schemes in MPI use however the idealized assumption of an ideal FFP or FFL topology and, thus, generate artifacts in the reconstruction. Our model-based approach is able to deal with these distortions and can generally be applied to dynamic magnetic fields that are approximately parallel to their velocity field. We show how this new 3D model can be discretized and inverted algebraically in order to recover the magnetic particle concentration. To model and describe the magnetic fields, we use decompositions of the fields in spherical harmonics. We complement the description of the new model with several simulations and experiments, exploring the effects of magnetic fields distortion and reconstruction parameters on the reconstruction.
Inverse problems are at the heart of many practical problems such as image reconstruction or nondestructive testing. A characteristic feature is their instability with respect to data perturbations. To stabilize the inversion process, regularization methods must be developed and applied. In this paper, we introduce the concept of filtered diagonal frame decomposition, which extends the classical filtered SVD to the case of frames. The use of frames as generalized singular systems allows a better match to a given class of potential solutions and is also beneficial for problems where the SVD is not analytically available. We show that filtered diagonal frame decompositions yield convergent regularization methods, derive convergence rates under source conditions and prove order optimality. Our analysis applies to bounded and unbounded forward operators. As a practical application of our tools, we study filtered diagonal frame decompositions for inverting the Radon transform as an unbounded operator on L2(R2).
Mathematical analysis of the 1D model and reconstruction schemes for magnetic particle imaging
(2018)
Magnetic particle imaging (MPI) is a promising new in vivo medical imaging modality in which distributions of super-paramagnetic nanoparticles are tracked based on their response in an applied magnetic field. In this paper we provide a mathematical analysis of the modeled MPI operator in the univariate situation. We provide a Hilbert space setup, in which the MPI operator is decomposed into simple building blocks and in which these building blocks are analyzed with respect to their mathematical properties. In turn, we obtain an analysis of the MPI forward operator and, in particular, of its ill-posedness properties. We further get that the singular values of the MPI core operator decrease exponentially. We complement our analytic results by some numerical studies which, in particular, suggest a rapid decay of the singular values of the MPI operator.
Most of the common model-based reconstruction schemes in magnetic particle imaging (MPI) use idealized assumptions, e.g., of an ideal field-free-line (FFL) topology. However, the magnetic fields that are generated in real MPI scanners have distortions and, therefore, model-based approaches often lead to inaccurate reconstructions and may contain artifacts. In order to improve the reconstruction quality in MPI, more realistic MPI models need to be derived. In the present work, we address this problem and present a hybrid model for MPI that allows us to incorporates real measurements of the applied magnetic fields. We will explain that the measurements, that are needed to setup a model for the magnetic fields, can be obtained in a novel calibration procedure that is independent of the resolution and which is much less time-consuming than the one employed in measurement-based MPI reconstructions.We will also present a discretization strategy for this model, that can be used in context of algebraic reconstructions. The presented approach was validated on simulated data in [1], however, its evaluation on real data is a topic for future research.
We investigate the reconstruction problem of limited angle tomography. Such problems arise naturally in applications like digital breast tomosynthesis, dental tomography, electron microscopy, etc. Since the acquired tomographic data is highly incomplete, the reconstruction problem is severely ill-posed and the traditional reconstruction methods, e.g. filtered backprojection (FBP), do not perform well in such situations.
To stabilize the reconstruction procedure additional prior knowledge about the unknown object has to be integrated into the reconstruction process. In this work, we propose the use of the sparse regularization technique in combination with curvelets. We argue that this technique gives rise to an edge-preserving reconstruction. Moreover, we show that the dimension of the problem can be significantly reduced in the curvelet domain. To this end, we give a characterization of the kernel of the limited angle Radon transform in terms of curvelets and derive a characterization of solutions obtained through curvelet sparse regularization. In numerical experiments, we will show that the theoretical results directly translate into practice and that the proposed method outperforms classical reconstructions.
We investigate the reconstruction problem for limited angle tomography. Such problems arise naturally in applications like digital breast tomosynthesis, dental tomography, etc. Since the acquired tomographic data is highly incomplete, the reconstruction problem is severely ill-posed and the traditional reconstruction methods, such as filtered backprojection (FBP), do not perform well in such situations. To stabilize the inversion we propose the use of a sparse regularization technique in combination with curvelets. We argue that this technique has the ability to preserve edges. As our main result, we present a characterization of the kernel of the limited angle Radon transform in terms of curvelets. Moreover, we characterize reconstructions which are obtained via curvelet sparse regularizations at a limited angular range. As a result, we show that the dimension of the limited angle problem can be significantly reduced in the curvelet domain.