Refine
Year of publication
Document Type
- conference proceeding (article) (68)
- Article (54)
- conference proceeding (presentation, abstract) (18)
- conference talk (8)
- Part of Periodical (5)
- Part of a Book (2)
- Moving Images (1)
- Preprint (1)
- Report (1)
Is part of the Bibliography
- no (158) (remove)
Keywords
- Biomechanik (12)
- Biomechanics (9)
- Simulation (9)
- Biomechanische Analyse (7)
- Hüftgelenkprothese (7)
- AnyBody (4)
- Bewegungsapparat (4)
- Spongiosa (4)
- biomechanics (4)
- Inverse dynamics (3)
- Lumbar spine (3)
- Musculoskeletal simulation (3)
- Schultergelenk (3)
- Anisotropie (2)
- AnyBody Modeling System (2)
- Belastung (2)
- Biomaterial (2)
- Computerunterstütztes Verfahren (2)
- Finite element analysis (2)
- Finite-Elemente-Methode (2)
- Forschung (2)
- Forschungsbericht (2)
- Gait analysis (2)
- Knochen (2)
- Knochenbruch (2)
- Mechanische Belastung (2)
- Musculoskeletal Modeling (2)
- Operationstechnik (2)
- Stress (2)
- THA (2)
- Test (2)
- Tissue Engineering (2)
- musculoskeletal simulation (2)
- total hip replacement (2)
- 3D-Druck (1)
- ASIS (1)
- Abduction tasks (1)
- Accoucheur (1)
- Adaptive clinical trial (1)
- Alter (1)
- Antibiotika (1)
- Arbeitsbedingungen (1)
- Autologous bone graft (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Bewegung (1)
- Bewegungsanalyse <Technik> (1)
- Biological models (1)
- Biologische Modelle (1)
- Biomechanical investigation (1)
- Bone harvesting (1)
- Bone imaging (1)
- Bone substitute materials (1)
- Bovine cartilage (1)
- Brustkorb (1)
- Brustwirbelsäule (1)
- Cancellous bone (1)
- Cartilage samples (1)
- Characterisation testing (1)
- Combined anteversion (1)
- Computer-assisted surgery (1)
- Computersimulation (1)
- Computertomografie (1)
- Computertomographie (1)
- Conventional surgery (1)
- Cup medialisation (1)
- Damage (1)
- Deformation behaviour (1)
- Distraktion (1)
- Dreidimensionale Bildverarbeitung (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Electromyography (1)
- Elektromyographie (1)
- Elite athletes (1)
- Ellenbogenstabilität (1)
- Ergonomics (1)
- Ermüdung (1)
- Ermüdungsbruch (1)
- FEA (1)
- Fatigue (1)
- Fatigue fracture (1)
- Femur first (1)
- Football (1)
- Gait (1)
- Ganganalyse (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Ground Reaction Force Prediction (1)
- Haltungsfehler (1)
- Head trauma (1)
- Hyaluronsäure (1)
- Hüftgelenk (1)
- Hüftgelenkpfanne (1)
- IMU (1)
- Iliac crest (1)
- Indian ink (1)
- Inertial Measurement Units (1)
- Internal fixator (1)
- Joint Reaction Forces (1)
- Kennzeichnung (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenbildung (1)
- Knochenentnahme (1)
- Knochenersatz (1)
- Knorpel (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Körper (1)
- Körperliche Belastung (1)
- Lastverteilung <Statik> (1)
- Le Fort III (1)
- Leg length (1)
- Leistungssportler (1)
- Leitfähgkeit (1)
- Lendenwirbelsäule (1)
- Ligament stiffness (1)
- MRI (1)
- Measurement and testing (1)
- Mechanical behaviour (1)
- Mehrkörpersimulation (1)
- Meniskusschaden (1)
- Mensch (1)
- Mesenchymzelle (1)
- Method labeling (1)
- Minimal-invasive Chirurgie (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Movement (1)
- Multibody Simulation (1)
- Multiresistant (1)
- Mund-Kiefer-Gesichts-Chirurgie (1)
- Muscle (1)
- Muscle influence (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscoloskeletal model (1)
- Musculoskeletal (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskelkraft (1)
- Muskuloskelettale Simulation (1)
- Nabelvene (1)
- Offset (1)
- Orthopädische Chirurgie (1)
- Osteoconductive (1)
- Osteomyelitis (1)
- Osteosynthese (1)
- Osteotomie (1)
- Parameter study (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Prognose (1)
- Prüfung (1)
- Resilience, psychological (1)
- Resilienz, psychologische (1)
- Rind (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- Sagittal balance (1)
- Schädel-Hirn-Trauma (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Speedcourt (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Stabilität (1)
- Steifigkeit (1)
- T-peel configuration (1)
- THR (1)
- Testing biomaterials (1)
- Thoracolumbar spine (1)
- Tinte (1)
- Torus (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vertebra (1)
- Violinspiel (1)
- Webcast (1)
- Werkstoff (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- anchorage (1)
- attention (1)
- biomechanical implant test (1)
- component position (1)
- critical hip joint loading (1)
- crosstalk (1)
- cup loading (1)
- distraction (1)
- dynamic multiplanar loading (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- esb (1)
- femoral offset (1)
- flexibility ellipsis (1)
- force angles (1)
- force pathways (1)
- form-finding (1)
- functional outcome (1)
- functionality (1)
- gait analysis (1)
- hand (1)
- happiness (1)
- high-impact exercisess (1)
- hip contact force (1)
- hip fractureg (1)
- humeroradial stability (1)
- implant migration (1)
- inertial measurement units (1)
- influence parameters (1)
- inverse dynamics (1)
- kinematics (1)
- lower back load (1)
- mechanical compliance (1)
- meniscus (1)
- moment arm (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- optical motion capture (1)
- osteoporosis (1)
- patient specific loading (1)
- pelvic floor (1)
- pelvic tilt (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rim loading (1)
- sadness (1)
- scaffolds (1)
- sensors (1)
- shoulder elevation (1)
- shoulder joint force (1)
- stem cells (1)
- subject-specific musculoskeletal modeling (1)
- subluxation (1)
- surface electromyography (1)
- tensegrity joint (1)
- three-dimensional computed tomography analysis (1)
- tissue engineering (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- validation (1)
- vector (1)
- violin (1)
- wearable motion-tracking sensors (1)
Institute
- Fakultät Maschinenbau (153)
- Labor Biomechanik (LBM) (152)
- Regensburg Center of Biomedical Engineering - RCBE (132)
- Regensburg Center of Health Sciences and Technology - RCHST (20)
- Hochschulleitung/Hochschulverwaltung (5)
- Institut für Angewandte Forschung und Wirtschaftskooperationen (IAFW) (4)
- Labor Werkstoffprüfung und Metallographie (4)
- Labor Faserverbundtechnik (LFT) (3)
- Labor Biofluidmechanik (2)
- Technologie-Campus Neustadt an der Donau (2)
Begutachtungsstatus
- peer-reviewed (45)
- begutachtet (5)
Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop, implement, and validate a fully detailed hand model using the AnyBody Modelling System (AMS) (AnyBody, Aalborg, Denmark). To achieve this, a consistent multiple cadaver dataset, including all extrinsic and intrinsic muscles, served as a basis. Various obstacle methods were implemented to obtain with the correct alignment of the muscle paths together with the full range of motion of the fingers. These included tori, cylinders, and spherical ellipsoids. The origin points of the lumbrical muscles within the tendon of the flexor digitorum profundus added a unique feature to the model. Furthermore, the possibility of an entire patient-specific scaling based on the hand length and width were implemented in the model. For model validation, experimental datasets from the literature were used, which included the comparison of numerically calculated moment arms of the wrist, thumb, and index finger muscles. In general, the results displayed good comparability of the model and experimental data. However, the extrinsic muscles showed higher accordance than the intrinsic ones. Nevertheless, the results showed, that the proposed developed inverse dynamics hand model offers opportunities in a broad field of applications, where the muscles and joint forces of the forearm play a crucial role.
Biomechanical Analysis of the Right Elevated Glenohumeral Joint in Violinists during Legato-Playing
(2021)
BACKGROUND:
Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements.
OBJECTIVE:
For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture.
METHODS:
Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position.
RESULTS:
The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture.
CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem.
Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose.
Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling.
Static pelvic tilt impacts functional cup position in total hip arthroplasty (THA). In the current study we investigated the effect of kinematic pelvic changes on cup position. In the course of a prospective controlled trial postoperative 3D-computed tomography (CT) and gait analysis before and 6 and 12 months after THA were obtained in 60 patients. Kinematic pelvic motion during gait was measured using Anybody Modeling System. By fusion with 3D-CT, the impact of kinematic pelvic tilt alterations on cup anteversion and inclination was calculated. Furthermore, risk factors correlating with high pelvic mobility were evaluated. During gait a high pelvic range of motion up to 15.6° exceeding 5° in 61.7% (37/60) of patients before THA was found. After surgery, the pelvis tilted posteriorly by a mean of 4.0 ± 6.6° (p < .001). The pelvic anteflexion led to a mean decrease of −1.9 ± 2.2° (p < .001) for cup inclination and −15.1 ± 6.1° (p < .001) for anteversion in relation to the anterior pelvic plane (APP). Kinematic pelvic changes resulted in a further change up to 2.3° for inclination and up to 12.3° for anteversion. In relation to the preoperative situation differences in postoperative cup position ranged from −4.4 to 4.6° for inclination and from −7.8 to 17.9° for anteversion, respectively. Female sex (p < .001) and normal body weight (p < .001) correlated with high alterations in pelvic tilt. Kinematic pelvic changes highly impact cup anteversion in THA. Surgeons using the APP as reference should aim for a higher anteversion of about 15° due to the functional anteflexion of the pelvis during gait.
Outputs of musculoskeletal models should be considered probabilistic rather than deterministic as they are affected by inaccuracies and estimations associated with the development of the model. One of these uncertainties being critical for modeling arises from the determination of the muscles' line of action and the physiological cross-sectional area. Therefore, the aim of this study was to evaluate the outcome sensitivity of model predictions from a musculoskeletal hand model in comparison to the uncertainty of these input parameters. For this purpose, the kinematics and muscle activities of different hand movements (abduction of the fingers, abduction of the thumb, and flexion of the thumb) were recorded. One thousand simulations were calculated for each movement using the Latin hypercube sampling method with a corresponding variation of the muscle origin/insertion points and the cross-sectional area. Comparing the standard hand to simulations incorporating uncertainties of input parameters shows no major deviations in on- and off-set time point of muscle activities. About 60% of simulations are located within a ± 30% interval around the standard model concerning joint reaction forces. The comparison with the variation of the input data leads to the conclusion that the standard hand model is able to provide not over-scattered outcomes and, therefore, can be considered relatively stable. These results are of practical importance to the personalization of a musculoskeletal model with subject-specific bone geometries and hence changed muscle line of action.
Für Fußballer:innen stellen muskuläre Verletzungen der unteren Extremitäten ein großes Problem dar. Ein Beispiel hierfür liefert die Nationalmannschaftsstürmerin Alexandra Popp, die aufgrund muskulärer Probleme das EM-Finale 2022 in Wembley kurzfristig verpasste. Oftmals stehen gerade hohe Anspannungssituationen in zeitlichem Zusammenhang mit Verletzungen, der Einfluss der psychischen Beanspruchung auf die biomechanischen Belastungen wird jedoch meist nur wenig beachtet.
Elbow stability is derived from a combination of muscular, ligamentous, and bony structures. After an elbow trauma the stability of the joint is an important decision criterion for the subsequent treatment. The decision regarding non-operative/operative care depends mostly on subjective assessments of medical experts. Therefore, the aim of this study is to use musculoskeletal simulations as an objective assessment tool to investigate the extent to which failure of different stabilizers affects the elbow stability and how these observations correspond to the assessment from clinical practice. A musculoskeletal elbow simulation model was developed for this aim. To investigate the stability of the elbow, varus/valgus moments were applied under 0°, 45°and 90° flexion while the respective cubital angle was analyzed. This was performed for nine different injury scenarios, which were also evaluated for stability by clinical experts. With the results, it can be determined by which injury pattern and under which flexion angle the elbow stability is impaired regarding varus/valgus moments. The scenario with a complete failure of the medial and lateral ligaments and a fracture of the radial head was identified as having the greatest instability. The study presented a numerical determination of elbow stability against varus/valgus moments regarding clinical injury patterns, as well as a comparison of the numerical outcome with experience gained in clinical practice. The numerical predictions agree well with the assessments of the clinical specialists. Thus, the results from musculoskeletal simulation can make an important contribution to a more objective assessment of the elbow stability.
Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity.
Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing
(2022)
BACKGROUND:
Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements.
OBJECTIVE:
For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture.
METHODS:
Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position.
RESULTS:
The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture.
CONCLUSIONS:
Elevating the right shoulder while playing the violin may pose a potential problem.
To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments.