Refine
Year of publication
Document Type
- conference proceeding (article) (68)
- Article (54)
- conference proceeding (presentation, abstract) (18)
- conference talk (8)
- Part of Periodical (5)
- Part of a Book (2)
- Moving Images (1)
- Preprint (1)
- Report (1)
Is part of the Bibliography
- no (158) (remove)
Keywords
- Biomechanik (12)
- Biomechanics (9)
- Simulation (9)
- Biomechanische Analyse (7)
- Hüftgelenkprothese (7)
- AnyBody (4)
- Bewegungsapparat (4)
- Spongiosa (4)
- biomechanics (4)
- Inverse dynamics (3)
- Lumbar spine (3)
- Musculoskeletal simulation (3)
- Schultergelenk (3)
- Anisotropie (2)
- AnyBody Modeling System (2)
- Belastung (2)
- Biomaterial (2)
- Computerunterstütztes Verfahren (2)
- Finite element analysis (2)
- Finite-Elemente-Methode (2)
- Forschung (2)
- Forschungsbericht (2)
- Gait analysis (2)
- Knochen (2)
- Knochenbruch (2)
- Mechanische Belastung (2)
- Musculoskeletal Modeling (2)
- Operationstechnik (2)
- Stress (2)
- THA (2)
- Test (2)
- Tissue Engineering (2)
- musculoskeletal simulation (2)
- total hip replacement (2)
- 3D-Druck (1)
- ASIS (1)
- Abduction tasks (1)
- Accoucheur (1)
- Adaptive clinical trial (1)
- Alter (1)
- Antibiotika (1)
- Arbeitsbedingungen (1)
- Autologous bone graft (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Bewegung (1)
- Bewegungsanalyse <Technik> (1)
- Biological models (1)
- Biologische Modelle (1)
- Biomechanical investigation (1)
- Bone harvesting (1)
- Bone imaging (1)
- Bone substitute materials (1)
- Bovine cartilage (1)
- Brustkorb (1)
- Brustwirbelsäule (1)
- Cancellous bone (1)
- Cartilage samples (1)
- Characterisation testing (1)
- Combined anteversion (1)
- Computer-assisted surgery (1)
- Computersimulation (1)
- Computertomografie (1)
- Computertomographie (1)
- Conventional surgery (1)
- Cup medialisation (1)
- Damage (1)
- Deformation behaviour (1)
- Distraktion (1)
- Dreidimensionale Bildverarbeitung (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Electromyography (1)
- Elektromyographie (1)
- Elite athletes (1)
- Ellenbogenstabilität (1)
- Ergonomics (1)
- Ermüdung (1)
- Ermüdungsbruch (1)
- FEA (1)
- Fatigue (1)
- Fatigue fracture (1)
- Femur first (1)
- Football (1)
- Gait (1)
- Ganganalyse (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Ground Reaction Force Prediction (1)
- Haltungsfehler (1)
- Head trauma (1)
- Hyaluronsäure (1)
- Hüftgelenk (1)
- Hüftgelenkpfanne (1)
- IMU (1)
- Iliac crest (1)
- Indian ink (1)
- Inertial Measurement Units (1)
- Internal fixator (1)
- Joint Reaction Forces (1)
- Kennzeichnung (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenbildung (1)
- Knochenentnahme (1)
- Knochenersatz (1)
- Knorpel (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Körper (1)
- Körperliche Belastung (1)
- Lastverteilung <Statik> (1)
- Le Fort III (1)
- Leg length (1)
- Leistungssportler (1)
- Leitfähgkeit (1)
- Lendenwirbelsäule (1)
- Ligament stiffness (1)
- MRI (1)
- Measurement and testing (1)
- Mechanical behaviour (1)
- Mehrkörpersimulation (1)
- Meniskusschaden (1)
- Mensch (1)
- Mesenchymzelle (1)
- Method labeling (1)
- Minimal-invasive Chirurgie (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Movement (1)
- Multibody Simulation (1)
- Multiresistant (1)
- Mund-Kiefer-Gesichts-Chirurgie (1)
- Muscle (1)
- Muscle influence (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscoloskeletal model (1)
- Musculoskeletal (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskelkraft (1)
- Muskuloskelettale Simulation (1)
- Nabelvene (1)
- Offset (1)
- Orthopädische Chirurgie (1)
- Osteoconductive (1)
- Osteomyelitis (1)
- Osteosynthese (1)
- Osteotomie (1)
- Parameter study (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Prognose (1)
- Prüfung (1)
- Resilience, psychological (1)
- Resilienz, psychologische (1)
- Rind (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- Sagittal balance (1)
- Schädel-Hirn-Trauma (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Speedcourt (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Stabilität (1)
- Steifigkeit (1)
- T-peel configuration (1)
- THR (1)
- Testing biomaterials (1)
- Thoracolumbar spine (1)
- Tinte (1)
- Torus (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vertebra (1)
- Violinspiel (1)
- Webcast (1)
- Werkstoff (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- anchorage (1)
- attention (1)
- biomechanical implant test (1)
- component position (1)
- critical hip joint loading (1)
- crosstalk (1)
- cup loading (1)
- distraction (1)
- dynamic multiplanar loading (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- esb (1)
- femoral offset (1)
- flexibility ellipsis (1)
- force angles (1)
- force pathways (1)
- form-finding (1)
- functional outcome (1)
- functionality (1)
- gait analysis (1)
- hand (1)
- happiness (1)
- high-impact exercisess (1)
- hip contact force (1)
- hip fractureg (1)
- humeroradial stability (1)
- implant migration (1)
- inertial measurement units (1)
- influence parameters (1)
- inverse dynamics (1)
- kinematics (1)
- lower back load (1)
- mechanical compliance (1)
- meniscus (1)
- moment arm (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- optical motion capture (1)
- osteoporosis (1)
- patient specific loading (1)
- pelvic floor (1)
- pelvic tilt (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rim loading (1)
- sadness (1)
- scaffolds (1)
- sensors (1)
- shoulder elevation (1)
- shoulder joint force (1)
- stem cells (1)
- subject-specific musculoskeletal modeling (1)
- subluxation (1)
- surface electromyography (1)
- tensegrity joint (1)
- three-dimensional computed tomography analysis (1)
- tissue engineering (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- validation (1)
- vector (1)
- violin (1)
- wearable motion-tracking sensors (1)
Institute
- Fakultät Maschinenbau (153)
- Labor Biomechanik (LBM) (152)
- Regensburg Center of Biomedical Engineering - RCBE (132)
- Regensburg Center of Health Sciences and Technology - RCHST (20)
- Hochschulleitung/Hochschulverwaltung (5)
- Institut für Angewandte Forschung und Wirtschaftskooperationen (IAFW) (4)
- Labor Werkstoffprüfung und Metallographie (4)
- Labor Faserverbundtechnik (LFT) (3)
- Labor Biofluidmechanik (2)
- Technologie-Campus Neustadt an der Donau (2)
Begutachtungsstatus
- peer-reviewed (45)
- begutachtet (5)
Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach.
Evaluation of muscle recruitment and muscle models in musculoskeletal simulation of dynamic motion
(2021)
Musculoskeletal simulation plays an increasingly important role in sports biomechanics. In the last years, the field of application widened from orthopaedics and ergonomics to sports [1]. A muscle recruitment algorithm with a quadratic objective function is usually used to calculate muscle activity in dynamic movements. The agreement of calculated and measured thigh muscle activity has already been investigated [2]. They found a strong agreement for sprinting and running, while the correlation decreased for side-cutting manoeuvres. Nevertheless, the influence of different muscle recruitment criteria on muscle activity in dynamic musculoskeletal simulations is currently unknown. Hence, this study aimed to analyse the effect of different muscle recruitment criteria and muscle models on the correlation of numerical and measured muscle activity in highly dynamic movements.
BACKGROUND:
Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG.
OBJECTIVE:
This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS:
For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets.
RESULTS:
The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account.
CONCLUSIONS:
Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough.
BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough.
Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity.
Einführung in die Mechanik
(2013)
Fragestellung
Es soll in dieser Computersimulationsstudie untersucht werden, wie der Osteosyntheseverbund Platte mit Schrauben im Verbund mit einer im mittleren Drittel gebrochenen Clavicula durch das Bewegungsausmaß
in vivo belastet ist. Was sind die grundlegenden Kräfte die auf Clavicula und Implantat wirken und welchen Einfl uss hat die Bruchform.
Methodik
Die Muskel- und Gelenkkräfte sowie die Belastung des Implantatverbundes wurden mit einer muskuloskelletalen
Simulationssoftware (AnyBody Technology, V.4) berechnet. Hierfür wurden mit einem komplexen Model des menschlichen Körpers folgende Bewegungen analysiert: eine Flexion von 160° und Abduktion 160° mit
einem Gewicht von 2 kg in der Hand. Aus CT-Patientendaten wurden zwei dreidimensionale Modelle des Clavicula-Implantat Verbundes gebildet, die sich in der Frakturform unterscheiden (Querfraktur und vertikale
Fraktur). In beiden Modellen wurde eine Claviculaosteosynthese in superiorer Position mit einer 6 Loch LCP mit 2 Schrauben pro Hauptfragment verwendet. Die Materialeigenschaften wurden aus der Dichte des Materials sowie aus Literaturdaten verwendet. Die Muskel- und Gelenkkräfte aus der muskuloskelletalen Berechnung wurden auf das Finite Elemente Modell übertragen und die Spannungen und Dehnungen des Implantat-Knochenverbundes
wurden berechnet.
Ergebnisse
Es zeigte sich, dass die simulierte in vivo Belastung stark abhängig vom Flexionswinkel ist. Das Implantat ist in der superioren Lage auf Biegung belastet, welche maximale Werte im Überschulterniveau erreicht. Die Bruchform mit anatomischer Reposition und Kontakt der Hauptfragmente zueinander führt zu einer deutlichen Entlastung des Osteosyntheseverbundes im Vergleich zu einer Bruchform mit vertikaler Fraktur.
Schlussfolgerung
Aus den Analysen ist eine Positionierung der Plattenosteosynthese für die im mittleren Drittel frakturierte Clavicula in anterior-superiorer Lage wünschenswert. Die anatomische Reposition entlastet den Osteosyntheseverbund und sollte möglichst erreicht werden. Die Nachbehandlung sollte ein Bewegungsausmaß für den Arm für 4 Wochen für einfache Bruchformen auf 70° Flexion und Abduktion limitieren und für komplexe Bruchformen diese Limitierung ausgedehnt werden.
Effect of the fractured calcaneus's peripheral fragment displacement on the triceps surae function
(2015)
In the structure of musculoskeletal injuries, calcaneal fractures account for up to 4 % of all skeletal fractures and up to 60 % of hindfoot fractures. The effect of the displacement of the peripheral fragment of the calcaneus on the calf muscles’s reaction forces at the time of the adoption of the simplified squatting position was investigated by modeling in AnyBody Modeling System 6.0 software. M.gastrocnemius (lateralis et medialis) in the initial phase of motion in all variants of the peripheral fragment displacement did not develop sufficient muscular effort in comparison to the intact calcaneus. M.soleus medialis et lateralis showed significant increase in muscle activity rates in the initial phase of motion (41.87 ± 1.90 H and 52.07 ± 2.10 H) before reaching its maximum values, as compared with those of the intact calcaneus. In the final phase of the movement, upon muscle reaches its maximum length, muscular strength indicators of the m.soleus returned to their original values or were significantly below them. The decline in muscle strength was due to shortening of the moment arm or muscle excursion in case of convergence of muscle attachment points. When the peripheral fragment is displaced, due to putting down the heel to the surface of the support in terms of anatomical muscle lengthening, it takes extra effort to achieve rest length and its maximum power. In all types of the displacement of the peripheral fragment, the function of three-headed calf muscle is disturbed with involvement of additional muscular effort and energy expenditure. This fact should motivate the surgeon on the need for accurate repositioning of bone fragments in calcaneal fractures with the displacement of the peripheral fragment.
Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.
Soccer is one of the most popular sports all around the world. It is an injurious type of sport with a focus on lower extremities and high psychological pressure during matches. The stressor is linked with injuries and an increased musculoskeletal loading. This study investigates the influence of cognitive stress on the load profile of the knee joint. Twelve professional youth soccer players performed highly dynamic runs with and without additional cognitive stress. The runs were analysed with a musculoskeletal simulation software. The data analysis shows no difference in knee joint reaction loading under additional mental stress compared to the baseline. Yet running times are significantly lower in the baseline. While there is no increase in the joint loads, the running times indicate an altered movement behaviour when the subjects are exposed to additional mental demand.
We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient’s gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome.
The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of normal gait. To evaluate the testing system, 12 femora pairs were tested under 25,000 cycles with two standard osteosyntheses (Proximal Femoral Nail Antirotation/Gamma3 Nail). For angular movement, the varus collapse to cut out (∝CO) (∝CO=4.8°±2.1° for blade and ∝CO=7.8°±3.8° for screw) was the dominant failure mode, and only slight rotational angle shifts (∝Rot) (∝Rot=1.7°±0.4° for blade and ∝Rot=2.4°±0.3° for screw) of the femoral head around the implant axis were observed. Angular displacements in varus direction and rotation were higher in specimens reinforced with screws. Hence, the cut out model and the migration directions showed a distinction between helical blade and hip screw. However, there were no significant differences between the different implants. The new setup is able to create clinical failures and allows to give evidence about the anchorage stability of different implant types under dynamic gait motion pattern.
To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments.
Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83–0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20–0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs.
A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry.
Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation
(2020)
Background:
Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity.
Methods:
Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction.
Results:
Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2% (gluteus medius).
Conclusions:
In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved.
A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis.
In recent years, musculoskeletal computation has become a widely used tool to investigate joint and muscle forces within the human body. However, the issue of muscle fatigue is not considered adequately in most models and is a challenging task. One aspect that needs to be examined is the interaction of muscles during an exhausting task. Therefore, an experimental study was designed to analyze the changes of back muscle recruitment pattern during such exercises.
In this study 38 subjects (27 male, 11 female, height = 177±8.5 cm, weight = 74.0±13.6 kg) participated. Each subject had to perform three static and three dynamic exhausting exercises where the back muscles were loaded with subject specific forces using a dynamometer adapter especially designed for the trunk muscles. To collect the muscle activity, twelve surface electromyography sensors were applied on the back, and four on the abdominal muscles. Muscle activity and fatigue were analyzed by calculating the maximum voluntary contraction normalized signal and the median frequency. At first the fatigue of m. erector spinae and m. multifidi was analyzed, since these muscles carry the main load during the exercises. Subsequently the activity of the m. trapezius, m. rectus abdominis and m. obliquus externus were investigated to determine recruitment patterns. To gain more detailed information of these patterns a numerical model was built using the AnyBody Modeling System™. Analyzing the measurements, we can observe an increasing muscle activity during isokinetic exercises while the force is constant. Since the activity in the simulation is defined as the current force output divided by the strength of the muscle, the strength parameter was scaled down based on the measured data, assuming a linear force – activity correlation, and using a numerical algorithm considering the influence of cross talk.
The results show, that changes in recruitment pattern can be divided into three major subgroups. Prior to total exhaustion, some of the subjects show additional activation of muscles in the trapezius region, while other subjects show an additional activation of abdominal muscles, increasing the intra-abdominal pressure which supports the spine. In the third group an activation in both regions can be observed.
The numerical simulations show an increasing activity of abdominal muscles as well as muscles in the upper back. Especially the m. latissimus dorsi shows a significantly higher activity.
The results lead to the conclusion that prior to total exhaustion, additional muscles are recruited to support the main muscles. It was shown that abdominal muscles are activated to support back muscles by pressurizing the trunk cavity to delay total exhaustion as long as possible. In conclusion, the results show that changes in muscle recruitment pattern need to be considered when introducing muscle fatigue to musculoskeletal models.
The development of biomimetic robots has gained research interest in the last years as it may both help under-standing processes of motion execution in biological systems as well as developping a novel generation of intelligent and energy efficient robots. However, exact model generation that builds up on observations and robot design is very time intensive. In this paper we present a novel pipeline for co-development of biomimetic hardware and simulation models based on biological Computer Tomography (CT) data. For this purpose we exploit State of the Art rapid prototyping technologies such as 3D Printing and the Neurorobotics Platform for musculoskeletal simulations in virtual environments. The co-development integrates both advantages of virtual and physical experimental models and is expected to increase development speed of controllers that can be tested on the simulated counterpart before application to a printed robot model. We demonstrate the pipeline by generating a one year old infant model as a musculoskeletal simulation model and a print-in-place 3D printed skeleton as a single movable part. Even though we hereonly introduce the initial body generation and only a first testsetup for a modular sensory and control framework, we can clearly spot advantages in terms of rapid model generation and highly biological related models. Engineering costs are reducedand models can be provided to a wide research community for controller testing in an early development phase.
PURPOSE:
The purpose of this study was to find a suitable method of labelling cartilage samples for the measurement of distraction distances in biomechanical testing.
METHODS:
Samples of bovine cartilage were labelled using five different methods: hydroquinone and silver nitrate (AgNO3), potassium permanganate (KMnO4) with sodium thiosulphate (Na2S2O3), India ink, heat, and laser energy. After the labelling, we analysed the cartilage samples with regard to cytotoxity by histochemical staining with ethidiumbromide homodimer (EthD-1) and calcein AM. Furthermore, we tested cartilages labelled with India ink and heat in a T-peel test configuration to analyse possible changes in the mechanical behaviour between marked and unlabelled samples.
RESULTS:
Only the labelling methods with Indian ink or a heated needle showed acceptable results in the cytotoxity test with regard to labelling persistence, accuracy, and the influence on consistency and viability of the chondrocytes. In the biomechanical T-peel configuration, heat-labelled samples collapsed significantly earlier than unlabelled samples.
CONCLUSION:
Labelling bovine cartilage samples with Indian ink in biomechanical testing is a reliable, accurate, inexpensive, and easy-to-perform method. This labelling method influenced neither the biomechanical behaviour nor the viability of the tissue compared to untreated bovine cartilage.
Biomechanik des Alterns
(2016)
Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose.
Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling.
Biomechanical Analysis of the Right Elevated Glenohumeral Joint in Violinists during Legato-Playing
(2021)
BACKGROUND:
Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements.
OBJECTIVE:
For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture.
METHODS:
Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position.
RESULTS:
The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture.
CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem.
Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing
(2022)
BACKGROUND:
Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements.
OBJECTIVE:
For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture.
METHODS:
Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position.
RESULTS:
The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture.
CONCLUSIONS:
Elevating the right shoulder while playing the violin may pose a potential problem.
Background
Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest.
Methods
Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed.
Results
Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest.
Conclusion
A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture.