Refine
Year of publication
Document Type
- conference proceeding (article) (55)
- Article (50)
- conference proceeding (presentation, abstract) (11)
- conference talk (6)
- Part of a Book (2)
- Moving Images (1)
- Preprint (1)
Language
- English (126) (remove)
Is part of the Bibliography
- no (126) (remove)
Keywords
- Biomechanik (10)
- Simulation (9)
- Biomechanics (8)
- Biomechanische Analyse (7)
- Hüftgelenkprothese (7)
- AnyBody (4)
- Bewegungsapparat (4)
- Spongiosa (4)
- biomechanics (4)
- Inverse dynamics (3)
- Lumbar spine (3)
- Musculoskeletal simulation (3)
- Schultergelenk (3)
- Anisotropie (2)
- AnyBody Modeling System (2)
- Belastung (2)
- Biomaterial (2)
- Computerunterstütztes Verfahren (2)
- Finite element analysis (2)
- Finite-Elemente-Methode (2)
- Gait analysis (2)
- Knochen (2)
- Knochenbruch (2)
- Mechanische Belastung (2)
- Musculoskeletal Modeling (2)
- Operationstechnik (2)
- Stress (2)
- THA (2)
- Test (2)
- Tissue Engineering (2)
- musculoskeletal simulation (2)
- total hip replacement (2)
- 3D-Druck (1)
- ASIS (1)
- Abduction tasks (1)
- Accoucheur (1)
- Adaptive clinical trial (1)
- Alter (1)
- Antibiotika (1)
- Arbeitsbedingungen (1)
- Autologous bone graft (1)
- Beckenbruch (1)
- Beckenkammknochen (1)
- Bewegungsanalyse <Technik> (1)
- Biomechanical investigation (1)
- Bone harvesting (1)
- Bone imaging (1)
- Bone substitute materials (1)
- Bovine cartilage (1)
- Brustkorb (1)
- Brustwirbelsäule (1)
- Cancellous bone (1)
- Cartilage samples (1)
- Characterisation testing (1)
- Combined anteversion (1)
- Computer-assisted surgery (1)
- Computersimulation (1)
- Computertomografie (1)
- Computertomographie (1)
- Conventional surgery (1)
- Cup medialisation (1)
- Damage (1)
- Deformation behaviour (1)
- Distraktion (1)
- Dreidimensionale Bildverarbeitung (1)
- EMG (1)
- Early recovery (1)
- Einflussgröße (1)
- Electromyography (1)
- Elektromyographie (1)
- Ergonomics (1)
- Ermüdung (1)
- Ermüdungsbruch (1)
- Euler-Bernoulli-Beam-Theory (1)
- FEA (1)
- Fatigue (1)
- Fatigue fracture (1)
- Femur first (1)
- Football (1)
- Gait (1)
- Ganganalyse (1)
- Glenohumeral joint reaction force (1)
- Glenohumeral stability (1)
- Ground Reaction Force Prediction (1)
- Haltungsfehler (1)
- Head trauma (1)
- Hyaluronsäure (1)
- Hüftgelenk (1)
- Hüftgelenkpfanne (1)
- IMU (1)
- Iliac crest (1)
- Indian ink (1)
- Inertial Measurement Units (1)
- Internal fixator (1)
- Joint Reaction Forces (1)
- Kennzeichnung (1)
- Kicks (1)
- Kniegelenk (1)
- Kniegelenkband (1)
- Knochenbildung (1)
- Knochenentnahme (1)
- Knochenersatz (1)
- Knorpel (1)
- Kontaktkraft (1)
- Kopfverletzung (1)
- Körper (1)
- Körperliche Belastung (1)
- Lastverteilung <Statik> (1)
- Le Fort III (1)
- Leg length (1)
- Leitfähgkeit (1)
- Lendenwirbelsäule (1)
- Ligament stiffness (1)
- MRI (1)
- Measurement and testing (1)
- Mechanical behaviour (1)
- Mehrkörpersimulation (1)
- Meniskusschaden (1)
- Mensch (1)
- Mesenchymzelle (1)
- Method labeling (1)
- Minimal-invasive Chirurgie (1)
- Motion Capture (1)
- Motion Capturing (1)
- Motion capture (1)
- Multibody Simulation (1)
- Multiresistant (1)
- Mund-Kiefer-Gesichts-Chirurgie (1)
- Muscle (1)
- Muscle influence (1)
- Muscle model (1)
- Muscle trajectory (1)
- Muscle weakness (1)
- Muscoloskeletal model (1)
- Musculoskeletal (1)
- Musculoskeletal Simulation (1)
- Musculoskeletal analysis (1)
- Musculoskeletal model (1)
- Musculoskeletal modelling (1)
- Musculoskeletal system (1)
- Muskelkraft (1)
- Nabelvene (1)
- Offset (1)
- Orthopädische Chirurgie (1)
- Osteoconductive (1)
- Osteomyelitis (1)
- Osteosynthese (1)
- Osteotomie (1)
- Parameter study (1)
- Pelvic ring fracture (1)
- Pelvis (1)
- Prognose (1)
- Prüfung (1)
- Rind (1)
- Robotik (1)
- Rotator cuff tears (1)
- Rotatorenmanschettenriss (1)
- Sagittal balance (1)
- Schädel-Hirn-Trauma (1)
- Shoulder joint (1)
- Shoulder joint complex (1)
- Signals (1)
- Speedcourt (1)
- Spinal fusion (1)
- Spine biomechanics (1)
- Stabilität (1)
- Steifigkeit (1)
- T-peel configuration (1)
- THR (1)
- Testing biomaterials (1)
- Thoracolumbar spine (1)
- Tinte (1)
- Torus (1)
- Vergleichende Anatomie (1)
- Verletzung (1)
- Vertebra (1)
- Violinspiel (1)
- Webcast (1)
- Werkstoff (1)
- Wirbelsäule (1)
- Wirbelsäulenversteifung (1)
- Wrapping (1)
- anchorage (1)
- attention (1)
- biomechanical implant test (1)
- bone biomechanics (1)
- component position (1)
- critical hip joint loading (1)
- crosstalk (1)
- cup loading (1)
- distraction (1)
- dynamic multiplanar loading (1)
- elbow stability (1)
- electromyography (1)
- embodiment (1)
- emotion (1)
- esb (1)
- femoral fracture (1)
- femoral offset (1)
- finite elements analysis (1)
- flexibility ellipsis (1)
- force angles (1)
- force pathways (1)
- form-finding (1)
- functional outcome (1)
- functionality (1)
- gait analysis (1)
- hand (1)
- happiness (1)
- high-impact exercisess (1)
- hip contact force (1)
- hip fractureg (1)
- humeroradial stability (1)
- implant migration (1)
- inertial measurement units (1)
- influence parameters (1)
- inverse dynamics (1)
- kinematics (1)
- lower back load (1)
- mechanical compliance (1)
- meniscus (1)
- moment arm (1)
- muscle activity (1)
- muscle injury (1)
- muscle recruitment (1)
- musculoskeletal disease (1)
- musculoskeletal modeling (1)
- musculoskeletal system (1)
- optical motion capture (1)
- osteoporosis (1)
- patient specific loading (1)
- pelvic floor (1)
- pelvic tilt (1)
- radial head arthroplasty (1)
- radial head prostheses (1)
- range of motion (1)
- rim loading (1)
- sadness (1)
- scaffolds (1)
- sensors (1)
- shoulder elevation (1)
- shoulder joint force (1)
- simplified loading model (1)
- stem cells (1)
- subject-specific musculoskeletal modeling (1)
- subluxation (1)
- surface electromyography (1)
- tensegrity joint (1)
- three-dimensional computed tomography analysis (1)
- tissue engineering (1)
- total hip anthroplasty (1)
- total hip arthroplasty (1)
- validation (1)
- vector (1)
- violin (1)
- wearable motion-tracking sensors (1)
Institute
- Fakultät Maschinenbau (126)
- Labor Biomechanik (LBM) (125)
- Regensburg Center of Biomedical Engineering - RCBE (106)
- Regensburg Center of Health Sciences and Technology - RCHST (13)
- Labor Werkstoffprüfung und Metallographie (4)
- Labor Biofluidmechanik (2)
- Fakultät Angewandte Natur- und Kulturwissenschaften (1)
- Labor Faserverbundtechnik (LFT) (1)
- Labor Finite-Elemente-Methode (FEM) (1)
- Labor Medizinprodukte (1)
Begutachtungsstatus
- peer-reviewed (43)
- begutachtet (1)
Influence of minimally invasive total hip replacement on hip reaction forces and their orientations
(2014)
Minimally invasive surgery (MIS) is becoming increasingly popular. Supporters claim that the main advantages of MIS total hip replacement (THR) are less pain and a faster rehabilitation and recovery. Critics claim that safety and efficacy of MIS are yet to be determined. We focused on a biomechanical comparison between surgical standard and MIS approaches for THR during the early recovery of patients. A validated, parameterized musculoskeletal model was set to perform a squat of a 50th percentile healthy European male. A bilateral motion was chosen to investigate effects on the contralateral side. Surgical approaches were simulated by excluding the incised muscles from the computations. Resulting hip reaction forces and their symmetry and orientation were analyzed. MIS THR seemed less influential on the symmetry index of hip reaction forces between the operated and nonoperated leg when compared to the standard lateral approach. Hip reaction forces at peak loads of the standard transgluteal approach were 24% higher on the contralateral side when compared to MIS approaches. Our results suggest that MIS THR contributes to a greater symmetry of hip reaction forces in absolute value as well as force-orientation following THR.
In the last few years, increasingly kicks to the head were observed as a criminal offense. This study examined the
influence of age, shoe type and kicking direction on the severity of head trauma.
Male test persons were divided into two groups “Old” and “Young”. Both groups were equipped with light
sneakers and combat boots. A standard laboratory crash dummy was used to simulate the victim’s body. First, the
dummy’s head, free floating above the ground, was kicked vertically. Second, the dummy’s head was kicked
horizontally. Established injury criteria were used to quantify the injury risk.
No influence concerning the type of foot wear and no difference between the groups “Old” and “Young” could be
found. For all analyses, kicking vertically generally lead to a higher risk for the subject compared to kicking
horizontally.
In this study, only the integral effect of the kicks could be analyzed. A detailed injury pattern cannot directly be
derived from the data. Nevertheless, the presented data show the massive potential of injuries associated with head
kicks.
Effect of the fractured calcaneus's peripheral fragment displacement on the triceps surae function
(2015)
The gold standard for the analysis of human kinematics and kinetics is a camera-based motion capture system in combination with force measurement platforms. Alternatively, inertial measurement units can be utilized to obtain human kinematics, while ground reaction forces are computed from full body dynamics. This setup represents a system independent from the spatial confinement of a gait laboratory. The aim of this study is the comparison of the two methods by the investigation of lower limb kinematics and the resulting joint reaction forces within the ankle-, knee- and hip joints. For this purpose, human motion during gait was captured simultaneously by both measurement techniques. 13 trials from 8 different test subjects were evaluated in total. IMU data was processed with a quaternion based Kalman Filter. The data sets were implemented into a musculoskeletal simulation program in order to drive a virtual human body model. Each sensor was aligned to the gravitational and magnetic field vectors of the earth. The angles of flexions, extensions and rotations were analyzed to determine kinematic differences. Joint reaction forces defined kinetic dissimilarities. The overall kinematic differences of both models yielded root mean square errors of 7.62°, 6.02°, 4.95°, 2.79°, 2.38° and 3.56° for ankle flexion, subtalar eversion, knee flexion, hip external rotation, hip abduction and hip flexion, respectively. The proximo-distal differences in force peaks between the models yielded overall for the ankle, 57.33 %Bodyweight(BW) ± 46.86 %BW (16.66 %(Maximum peak to peak) ± 13.62 %) for the knee 37.09 %BW ± 29.33 %BW (17.65 % ± 15.44 %) and 32.03 %BW ± 24.33 %BW (15.6 % ± 12.54 %) for the hip. The overall outcome of this work investigated an approach independent of the common setup of the gait laboratory, thus enabling a cheaper and more flexible technology as an alternative. However, kinematic and thus kinetic differences remain rather large. Future work aims to improve the contact criterion for the calculation of the ground reaction forces and the implementation of a full-body calibration algorithm for the IMU system in order to counteract magnetic field disturbances.
Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation
(2020)
Background:
Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity.
Methods:
Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction.
Results:
Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2% (gluteus medius).
Conclusions:
In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved.
The musculoskeletal load scenario of computer-assisted Femur-First THR up to one year after surgery
(2015)
High loads can appear in the individual joints of the human foot while the driver uses the pedals, in particular, during breaking. Measuring these internal forces is very difficult or almost impossible; therefore, advanced models are necessary to perform musculoskeletal simulations. The objective of this investigation was to see what loads are acting in the individual foot joints from the phalanges to calcaneus and talus during different brake scenarios. The Glasgow-Maastricht AnyBody Foot Model with 26 separate segments, connected by joints, ligaments and muscles was used inside the AnyBody Modeling System to compute individual mid foot joint loads. The amount, the direction of the force and additionally also the load insertion point was varied for several simulations. Figure 1: Seated musculoskeletal body model with applied brake force and forces for the lateral, intermediate and medial cuneiform-navicular joint for two different brake forces. The simulation showed that for the different brake scenarios, different muscles will be activated in the human and therefore different loads are apply in the fore-and mid-foot, respectively. The torso of the subject was assumed to be fixed in the seat. Further studies are ongoing to simulate the seat as an elastic element that allows different H-point locations according to the different loadings in the foot from the brake pedal using a new inverse dynamics analysis method called force-dependent kinematics.
A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints.
In recent years, musculoskeletal computation has become a widely used tool to investigate joint and muscle forces within the human body. However, the issue of muscle fatigue is not considered adequately in most models and is a challenging task. One aspect that needs to be examined is the interaction of muscles during an exhausting task. Therefore, an experimental study was designed to analyze the changes of back muscle recruitment pattern during such exercises.
In this study 38 subjects (27 male, 11 female, height = 177±8.5 cm, weight = 74.0±13.6 kg) participated. Each subject had to perform three static and three dynamic exhausting exercises where the back muscles were loaded with subject specific forces using a dynamometer adapter especially designed for the trunk muscles. To collect the muscle activity, twelve surface electromyography sensors were applied on the back, and four on the abdominal muscles. Muscle activity and fatigue were analyzed by calculating the maximum voluntary contraction normalized signal and the median frequency. At first the fatigue of m. erector spinae and m. multifidi was analyzed, since these muscles carry the main load during the exercises. Subsequently the activity of the m. trapezius, m. rectus abdominis and m. obliquus externus were investigated to determine recruitment patterns. To gain more detailed information of these patterns a numerical model was built using the AnyBody Modeling System™. Analyzing the measurements, we can observe an increasing muscle activity during isokinetic exercises while the force is constant. Since the activity in the simulation is defined as the current force output divided by the strength of the muscle, the strength parameter was scaled down based on the measured data, assuming a linear force – activity correlation, and using a numerical algorithm considering the influence of cross talk.
The results show, that changes in recruitment pattern can be divided into three major subgroups. Prior to total exhaustion, some of the subjects show additional activation of muscles in the trapezius region, while other subjects show an additional activation of abdominal muscles, increasing the intra-abdominal pressure which supports the spine. In the third group an activation in both regions can be observed.
The numerical simulations show an increasing activity of abdominal muscles as well as muscles in the upper back. Especially the m. latissimus dorsi shows a significantly higher activity.
The results lead to the conclusion that prior to total exhaustion, additional muscles are recruited to support the main muscles. It was shown that abdominal muscles are activated to support back muscles by pressurizing the trunk cavity to delay total exhaustion as long as possible. In conclusion, the results show that changes in muscle recruitment pattern need to be considered when introducing muscle fatigue to musculoskeletal models.
Mental stress reduces performance and changes musculoskeletal loading in football-related movements
(2020)
Purpose:
Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Hence, this study investigated the musculoskeletal response of elite youth football players during highly dynamic movements under stress. The hypothesis is that mental stress reduces performance and changes the muscular forces exerted.
Materials & methods:
Twelve elite youth football players were subjected to mental stress while performing sports-specific change-of-direction movements. A modified version of the d2 attention test was used as stressor. The kinetics are computed using inverse dynamics. Running times and exerted forces of injury-prone muscles were analysed.
Results:
The stressor runs were rated more mentally demanding by the players (p = 0.006, rs = 0.37) with unchanged physical demand (p = 0.777, rs = 0.45). This resulted in 10% longer running times under stress (p < 0.001, d = −1.62). The musculoskeletal analysis revealed higher peak muscle forces under mental stress for some players but not for others.
Discussion:
The study shows that motion capture combined with musculoskeletal computation is suitable to analyse the effects of stress on athletes in highly dynamic movements. For the first time in football medicine, our data quantifies an association between mental stress with reduced football players’ performance and changes in muscle force.
Musculoskeletal simulations of lumbar spine loading rely on a geometrical representation of the anatomy. However, this data has an inherent inaccuracy. This study evaluates the influence of defined geometrical parameters on lumbar spine loading utilising five parametrised musculoskeletal lumbar spine models for four different postures. The influence of the dimensions of vertebral body, disc, posterior parts of the vertebrae as well as the curvature of the lumbar spine was studied. Additionally, simulations with combinations of selected parameters were conducted. Changes in L4/L5 resultant joint force were used as outcome variable. Variations of the vertebral body height, disc height, transverse process width and the curvature of the lumbar spine were the most influential.
These parameters can be easily acquired from X-rays and should be used to morph a musculoskeletal lumbar spine model for subject-specific approaches with respect to bone geometry. Furthermore, the model was very sensitive to uncommon configurations and therefore, it is advised that stiffness properties of discs and ligaments should be individualised.