Refine
Year of publication
Document Type
- Article (60)
- conference proceeding (article) (52)
- conference proceeding (presentation, abstract) (33)
- Preprint (4)
- Book (1)
- Part of a Book (1)
Is part of the Bibliography
- no (151)
Keywords
- Bildgebendes Verfahren (18)
- Deep Learning (16)
- Diagnose (13)
- Artificial Intelligence (12)
- Künstliche Intelligenz (12)
- Gehirn (11)
- Maschinelles Lernen (11)
- Kernspintomografie (9)
- Dreidimensionale Bildverarbeitung (8)
- Registrierung <Bildverarbeitung> (8)
Institute
- Fakultät Informatik und Mathematik (151) (remove)
Begutachtungsstatus
- peer-reviewed (77)
- begutachtet (1)
GinJinn: An object-detection pipeline for automated feature extraction from herbarium specimens
(2020)
PREMISE:
The generation of morphological data in evolutionary, taxonomic, and ecological studies of plants using herbarium material has traditionally been a labor-intensive task. Recent progress in machine learning using deep artificial neural networks (deep learning) for image classification and object detection has facilitated the establishment of a pipeline for the automatic recognition and extraction of relevant structures in images of herbarium specimens.
METHODS AND RESULTS:
We implemented an extendable pipeline based on state-of-the-art deep-learning object-detection methods to collect leaf images from herbarium specimens of two species of the genus Leucanthemum. Using 183 specimens as the training data set, our pipeline extracted one or more intact leaves in 95% of the 61 test images.
CONCLUSIONS:
We establish GinJinn as a deep-learning object-detection tool for the automatic recognition and extraction of individual leaves or other structures from herbarium specimens. Our pipeline offers greater flexibility and a lower entrance barrier than previous image-processing approaches based on hand-crafted features.
Background and aims
Celiac disease with its endoscopic manifestation of villous atrophy is underdiagnosed worldwide. The application of artificial intelligence (AI) for the macroscopic detection of villous atrophy at routine esophagogastroduodenoscopy may improve diagnostic performance.
Methods
A dataset of 858 endoscopic images of 182 patients with villous atrophy and 846 images from 323 patients with normal duodenal mucosa was collected and used to train a ResNet 18 deep learning model to detect villous atrophy. An external data set was used to test the algorithm, in addition to six fellows and four board certified gastroenterologists. Fellows could consult the AI algorithm’s result during the test. From their consultation distribution, a stratification of test images into “easy” and “difficult” was performed and used for classified performance measurement.
Results
External validation of the AI algorithm yielded values of 90 %, 76 %, and 84 % for sensitivity, specificity, and accuracy, respectively. Fellows scored values of 63 %, 72 % and 67 %, while the corresponding values in experts were 72 %, 69 % and 71 %, respectively. AI consultation significantly improved all trainee performance statistics. While fellows and experts showed significantly lower performance for “difficult” images, the performance of the AI algorithm was stable.
Conclusion
In this study, an AI algorithm outperformed endoscopy fellows and experts in the detection of villous atrophy on endoscopic still images. AI decision support significantly improved the performance of non-expert endoscopists. The stable performance on “difficult” images suggests a further positive add-on effect in challenging cases.
Einleitung Die Endoskopische Retrograde Cholangiopankreatikographie (ERCP) ist der Goldstandard in der Diagnostik und Therapie von Erkrankungen des pankreatobiliären Trakts. Jedoch ist sie technisch sehr anspruchsvoll und weist eine vergleichsweise hohe Komplikationsrate auf.
Ziele
In der vorliegenden Machbarkeitsstudie soll geprüft werden, ob mithilfe eines Deep-learning-Algorithmus die Papille und das Ostium zuverlässig detektiert werden können und somit für Endoskopiker mit geringer Erfahrung ein geeignetes Hilfsmittel, insbesondere für die Ausbildungssituation, darstellen könnten.
Methodik
Wir betrachteten insgesamt 606 Bilddatensätze von 65 Patienten. In diesen wurde sowohl die Papilla duodeni major als auch das Ostium segmentiert. Anschließend wurde eine neuronales Netz mittels eines Deep-learning-Algorithmus trainiert. Außerdem erfolgte eine 5-fache Kreuzvaldierung.
Ergebnisse
Bei einer 5-fachen Kreuzvaldierung auf den 606 gelabelten Daten konnte für die Klasse Papille eine F1-Wert von 0,7908, eine Sensitivität von 0,7943 und eine Spezifität von 0,9785 erreicht werden, für die Klasse Ostium eine F1-Wert von 0,5538, eine Sensitivität von 0,5094 und eine Spezifität von 0,9970 (vgl. [Tab. 1]). Unabhängig von der Klasse zeigte sich gemittelt (Klasse Papille und Klasse Ostium) ein F1-Wert von 0,6673, eine Sensitivität von 0,6519 und eine Spezifität von 0,9877 (vgl. [Tab. 2]).
Schlussfolgerung
In vorliegende Machbarkeitsstudie konnte das neuronale Netz die Papilla duodeni major mit einer hohen Sensitivität und sehr hohen Spezifität identifizieren. Bei der Detektion des Ostiums war die Sensitivität deutlich geringer. Zukünftig soll das das neuronale Netz mit mehr Daten trainiert werden. Außerdem ist geplant, den Algorithmus auch auf Videos anzuwenden. Somit könnte langfristig ein geeignetes Hilfsmittel für die ERCP etabliert werden.
Aims
VA is an endoscopic finding of celiac disease (CD), which can easily be missed if pretest probability is low. In this study, we aimed to develop an artificial intelligence (AI) algorithm for the detection of villous atrophy on endoscopic images.
Methods
858 images from 182 patients with VA and 846 images from 323 patients with normal duodenal mucosa were used for training and internal validation of an AI algorithm (ResNet18). A separate dataset was used for external validation, as well as determination of detection performance of experts, trainees and trainees with AI support. According to the AI consultation distribution, images were stratified into “easy” and “difficult”.
Results
Internal validation showed 82%, 85% and 84% for sensitivity, specificity and accuracy. External validation showed 90%, 76% and 84%. The algorithm was significantly more sensitive and accurate than trainees, trainees with AI support and experts in endoscopy. AI support in trainees was associated with significantly improved performance. While all endoscopists showed significantly lower detection for “difficult” images, AI performance remained stable.
Conclusions
The algorithm outperformed trainees and experts in sensitivity and accuracy for VA detection. The significant improvement with AI support suggests a potential clinical benefit. Stable performance of the algorithm in “easy” and “difficult” test images may indicate an advantage in macroscopically challenging cases.
Aims
Human-computer interactions (HCI) may have a relevant impact on the performance of Artificial Intelligence (AI). Studies show that although endoscopists assessing Barrett’s esophagus (BE) with AI improve their performance significantly, they do not achieve the level of the stand-alone performance of AI. One aspect of HCI is the impact of AI on the degree of certainty and confidence displayed by the endoscopist. Indirectly, diagnostic confidence when using AI may be linked to trust and acceptance of AI. In a BE video study, we aimed to understand the impact of AI on the diagnostic confidence of endoscopists and the possible correlation with diagnostic performance.
Methods
22 endoscopists from 12 centers with varying levels of BE experience reviewed ninety-six standardized endoscopy videos. Endoscopists were categorized into experts and non-experts and randomly assigned to assess the videos with and without AI. Participants were randomized in two arms: Arm A assessed videos first without AI and then with AI, while Arm B assessed videos in the opposite order. Evaluators were tasked with identifying BE-related neoplasia and rating their confidence with and without AI on a scale from 0 to 9.
Results
The utilization of AI in Arm A (without AI first, with AI second) significantly elevated confidence levels for experts and non-experts (7.1 to 8.0 and 6.1 to 6.6, respectively). Only non-experts benefitted from AI with a significant increase in accuracy (68.6% to 75.5%). Interestingly, while the confidence levels of experts without AI were higher than those of non-experts with AI, there was no significant difference in accuracy between these two groups (71.3% vs. 75.5%). In Arm B (with AI first, without AI second), experts and non-experts experienced a significant reduction in confidence (7.6 to 7.1 and 6.4 to 6.2, respectively), while maintaining consistent accuracy levels (71.8% to 71.8% and 67.5% to 67.1%, respectively).
Conclusions
AI significantly enhanced confidence levels for both expert and non-expert endoscopists. Endoscopists felt significantly more uncertain in their assessments without AI. Furthermore, experts with or without AI consistently displayed higher confidence levels than non-experts with AI, irrespective of comparable outcomes. These findings underscore the possible role of AI in improving diagnostic confidence during endoscopic assessment.
Effect of AI on performance of endoscopists to detect Barrett neoplasia: A Randomized Tandem Trial
()
Background and study aims
To evaluate the effect of an AI-based clinical decision support system (AI) on the performance and diagnostic confidence of endoscopists during the assessment of Barrett's esophagus (BE).
Patients and Methods
Ninety-six standardized endoscopy videos were assessed by 22 endoscopists from 12 different centers with varying degrees of BE experience.
The assessment was randomized into two video sets: Group A (review first without AI and second with AI) and group B (review first with AI and second without AI). Endoscopists were required to evaluate each video for the presence of Barrett's esophagus-related neoplasia (BERN) and then decide on a spot for a targeted biopsy. After the second assessment, they were allowed to change their clinical decision and confidence level.
Results
AI had a standalone sensitivity, specificity, and accuracy of 92.2%, 68.9%, and 81.6%, respectively. Without AI, BE experts had an overall sensitivity, specificity, and accuracy of 83.3%, 58.1 and 71.5%, respectively. With AI, BE nonexperts showed a significant improvement in sensitivity and specificity when videos were assessed a second time with AI (sensitivity 69.7% (95% CI, 65.2% - 74.2%) to 78.0% (95% CI, 74.0% - 82.0%); specificity 67.3% (95% CI, 62.5% - 72.2%) to 72.7% (95 CI, 68.2% - 77.3%). In addition, the diagnostic confidence of BE nonexperts improved significantly with AI.
Conclusion
BE nonexperts benefitted significantly from the additional AI. BE experts and nonexperts remained below the standalone performance of AI, suggesting that there may be other factors influencing endoscopists to follow or discard AI advice.
The endoscopic features associated with eosinophilic esophagitis (EoE) may be missed during routine endoscopy. We aimed to develop and evaluate an Artificial Intelligence (AI) algorithm for detecting and quantifying the endoscopic features of EoE in white light images, supplemented by the EoE Endoscopic Reference Score (EREFS). An AI algorithm (AI-EoE) was constructed and trained to differentiate between EoE and normal esophagus using endoscopic white light images extracted from the database of the University Hospital Augsburg. In addition to binary classification, a second algorithm was trained with specific auxiliary branches for each EREFS feature (AI-EoE-EREFS). The AI algorithms were evaluated on an external data set from the University of North Carolina, Chapel Hill (UNC), and compared with the performance of human endoscopists with varying levels of experience. The overall sensitivity, specificity, and accuracy of AI-EoE were 0.93 for all measures, while the AUC was 0.986. With additional auxiliary branches for the EREFS categories, the AI algorithm (AI-EoEEREFS) performance improved to 0.96, 0.94, 0.95, and 0.992 for sensitivity, specificity, accuracy, and AUC, respectively. AI-EoE and AI-EoE-EREFS performed significantly better than endoscopy beginners and senior fellows on the same set of images. An AI algorithm can be trained to detect and quantify endoscopic features of EoE with excellent performance scores. The addition of the EREFS criteria improved the performance of the AI algorithm, which performed significantly better than endoscopists with a lower or medium experience level.
In this study, we aimed to develop an artificial intelligence clinical decision support solution to mitigate operator-dependent limitations during complex endoscopic procedures such as endoscopic submucosal dissection and peroral endoscopic myotomy, for example, bleeding and perforation. A DeepLabv3-based model was trained to delineate vessels, tissue structures and instruments on endoscopic still images from such procedures. The mean cross-validated Intersection over Union and Dice Score were 63% and 76%, respectively. Applied to standardised video clips from third-space endoscopic procedures, the algorithm showed a mean vessel detection rate of 85% with a false-positive rate of 0.75/min. These performance statistics suggest a potential clinical benefit for procedure safety, time and also training.
Aims
Eosinophilic esophagitis (EoE) is easily missed during endoscopy, either because physicians are not familiar with its endoscopic features or the morphologic changes are too subtle. In this preliminary paper, we present the first attempt to detect EoE in endoscopic white light (WL) images using a deep learning network (EoE-AI).
Methods
401 WL images of eosinophilic esophagitis and 871 WL images of normal esophageal mucosa were evaluated. All images were assessed for the Endoscopic Reference score (EREFS) (edema, rings, exudates, furrows, strictures). Images with strictures were excluded. EoE was defined as the presence of at least 15 eosinophils per high power field on biopsy. A convolutional neural network based on the ResNet architecture with several five-fold cross-validation runs was used. Adding auxiliary EREFS-classification branches to the neural network allowed the inclusion of the scores as optimization criteria during training. EoE-AI was evaluated for sensitivity, specificity, and F1-score. In addition, two human endoscopists evaluated the images.
Results
EoE-AI showed a mean sensitivity, specificity, and F1 of 0.759, 0.976, and 0.834 respectively, averaged over the five distinct cross-validation runs. With the EREFS-augmented architecture, a mean sensitivity, specificity, and F1-score of 0.848, 0.945, and 0.861 could be demonstrated respectively. In comparison, the two human endoscopists had an average sensitivity, specificity, and F1-score of 0.718, 0.958, and 0.793.
Conclusions
To the best of our knowledge, this is the first application of deep learning to endoscopic images of EoE which were also assessed after augmentation with the EREFS-score. The next step is the evaluation of EoE-AI using an external dataset. We then plan to assess the EoE-AI tool on endoscopic videos, and also in real-time. This preliminary work is encouraging regarding the ability for AI to enhance physician detection of EoE, and potentially to do a true “optical biopsy” but more work is needed.
Einleitung
Die Differenzierung zwischen nicht dysplastischem Barrett-Ösophagus (NDBE) und mit Barrett-Ösophagus assoziierten Neoplasien (BERN) während der endoskopischen Inspektion erfordert viel Expertise. Die frühe Diagnosestellung ist wichtig für die weitere Prognose des Barrett-Karzinoms. In Deutschland werden Patient:innen mit einem Barrett-Ösophagus (BE) in der Regel im niedergelassenen Sektor überwacht.
Ziele
Ziel ist es, den Einfluss von einem auf Künstlicher Intelligenz (KI) basierenden klinischen Entscheidungsunterstützungssystems (CDSS) auf die Performance von niedergelassenen Gastroenterolog:innen (NG) bei der Evaluation von Barrett-Ösophagus (BE) zu untersuchen.
Methodik
Es erfolgte die prospektive Sammlung von 96 unveränderten hochauflösenden Videos mit Fällen von Patient:innen mit histologisch bestätigtem NDBE und BERN. Alle eingeschlossenen Fälle enthielten mindestens zwei der folgenden Darstellungsmethoden: HD-Weißlichtendoskopie, Narrow Band Imaging oder Texture and Color Enhancement Imaging. Sechs NG von sechs unterschiedlichen Praxen wurden als Proband:innen eingeschlossen. Es erfolgte eine permutierte Block-Randomisierung der Videofälle in entweder Gruppe A oder Gruppe B. Gruppe A implizierte eine Evaluation des Falls durch Proband:innen zunächst ohne KI und anschließend mit KI als CDSS. In Gruppe B erfolgte die Evaluation in umgekehrter Reihenfolge. Anschließend erfolgte eine zufällige Wiedergabe der so entstandenen Subgruppen im Rahmen des Tests.
Ergebnis
In diesem Test konnte ein von uns entwickeltes KI-System (Barrett-Ampel) eine Sensitivität von 92,2%, eine Spezifität von 68,9% und eine Accuracy von 81,3% erreichen. Mit der Hilfe von KI verbesserte sich die Sensitivität der NG von 64,1% auf 71,2% (p<0,001) und die Accuracy von 66,3% auf 70,8% (p=0,006) signifikant. Eine signifikante Verbesserung dieser Parameter zeigte sich ebenfalls, wenn die Proband:innen die Fälle zunächst ohne KI evaluierten (Gruppe A). Wurde der Fall jedoch als Erstes mit der Hilfe von KI evaluiert (Gruppe B), blieb die Performance nahezu konstant.
Schlussfolgerung
Es konnte ein performantes KI-System zur Evaluation von BE entwickelt werden. NG verbessern sich bei der Evaluation von BE durch den Einsatz von KI.
Aims
Evaluation of the add-on effect an artificial intelligence (AI) based clinical decision support system has on the performance of endoscopists with different degrees of expertise in the field of Barrett's esophagus (BE) and Barrett's esophagus-related neoplasia (BERN).
Methods
The support system is based on a multi-task deep learning model trained to solve a segmentation and several classification tasks. The training approach represents an extension of the ECMT semi-supervised learning algorithm. The complete system evaluates a decision tree between estimated motion, classification, segmentation, and temporal constraints, to decide when and how the prediction is highlighted to the observer. In our current study, ninety-six video cases of patients with BE and BERN were prospectively collected and assessed by Barrett's specialists and non-specialists. All video cases were evaluated twice – with and without AI assistance. The order of appearance, either with or without AI support, was assigned randomly. Participants were asked to detect and characterize regions of dysplasia or early neoplasia within the video sequences.
Results
Standalone sensitivity, specificity, and accuracy of the AI system were 92.16%, 68.89%, and 81.25%, respectively. Mean sensitivity, specificity, and accuracy of expert endoscopists without AI support were 83,33%, 58,20%, and 71,48 %, respectively. Gastroenterologists without Barrett's expertise but with AI support had a comparable performance with a mean sensitivity, specificity, and accuracy of 76,63%, 65,35%, and 71,36%, respectively.
Conclusions
Non-Barrett's experts with AI support had a similar performance as experts in a video-based study.
Aims
Artificial Intelligence (AI) systems in gastrointestinal endoscopy are narrow because they are trained to solve only one specific task. Unlike Narrow-AI, general AI systems may be able to solve multiple and unrelated tasks. We aimed to understand whether an AI system trained to detect, characterize, and segment early Barrett’s neoplasia (Barrett’s AI) is only capable of detecting this pathology or can also detect and segment other diseases like early squamous cell cancer (SCC).
Methods
120 white light (WL) and narrow-band endoscopic images (NBI) from 60 patients (1 WL and 1 NBI image per patient) were extracted from the endoscopic database of the University Hospital Augsburg. Images were annotated by three expert endoscopists with extensive experience in the diagnosis and endoscopic resection of early esophageal neoplasias. An AI system based on DeepLabV3+architecture dedicated to early Barrett’s neoplasia was tested on these images. The AI system was neither trained with SCC images nor had it seen the test images prior to evaluation. The overlap between the three expert annotations („expert-agreement“) was the ground truth for evaluating AI performance.
Results
Barrett’s AI detected early SCC with a mean intersection over reference (IoR) of 92% when at least 1 pixel of the AI prediction overlapped with the expert-agreement. When the threshold was increased to 5%, 10%, and 20% overlap with the expert-agreement, the IoR was 88%, 85% and 82%, respectively. The mean Intersection Over Union (IoU) – a metric according to segmentation quality between the AI prediction and the expert-agreement – was 0.45. The mean expert IoU as a measure of agreement between the three experts was 0.60.
Conclusions
In the context of this pilot study, the predictions of SCC by a Barrett’s dedicated AI showed some overlap to the expert-agreement. Therefore, features learned from Barrett’s cancer-related training might be helpful also for SCC prediction. Our results allow different possible explanations. On the one hand, some Barrett’s cancer features generalize toward the related task of assessing early SCC. On the other hand, the Barrett’s AI is less specific to Barrett’s cancer than a general predictor of pathological tissue. However, we expect to enhance the detection quality significantly by extending the training to SCC-specific data. The insight of this study opens the way towards a transfer learning approach for more efficient training of AI to solve tasks in other domains.
Aims
While AI has been successfully implemented in detecting and characterizing colonic polyps, its role in therapeutic endoscopy remains to be elucidated. Especially third space endoscopy procedures like ESD and peroral endoscopic myotomy (POEM) pose a technical challenge and the risk of operator-dependent complications like intraprocedural bleeding and perforation. Therefore, we aimed at developing an AI-algorithm for intraprocedural real time vessel detection during ESD and POEM.
Methods
A training dataset consisting of 5470 annotated still images from 59 full-length videos (47 ESD, 12 POEM) and 179681 unlabeled images was used to train a DeepLabV3+neural network with the ECMT semi-supervised learning method. Evaluation for vessel detection rate (VDR) and time (VDT) of 19 endoscopists with and without AI-support was performed using a testing dataset of 101 standardized video clips with 200 predefined blood vessels. Endoscopists were stratified into trainees and experts in third space endoscopy.
Results
The AI algorithm had a mean VDR of 93.5% and a median VDT of 0.32 seconds. AI support was associated with a statistically significant increase in VDR from 54.9% to 73.0% and from 59.0% to 74.1% for trainees and experts, respectively. VDT significantly decreased from 7.21 sec to 5.09 sec for trainees and from 6.10 sec to 5.38 sec for experts in the AI-support group. False positive (FP) readings occurred in 4.5% of frames. FP structures were detected significantly shorter than true positives (0.71 sec vs. 5.99 sec).
Conclusions
AI improved VDR and VDT of trainees and experts in third space endoscopy and may reduce performance variability during training. Further research is needed to evaluate the clinical impact of this new technology.
Aims
Endoscopic retrograde cholangiopancreaticography (ERCP) is the gold standard in the diagnosis as well as treatment of diseases of the pancreatobiliary tract. However, it is technically complex and has a relatively high complication rate. In particular, cannulation of the papillary ostium remains challenging. The aim of this study is to examine whether a deep-learning algorithm can be used to detect the major duodenal papilla and in particular the papillary ostium reliably and could therefore be a valuable tool for inexperienced endoscopists, particularly in training situation.
Methods
We analyzed a total of 654 retrospectively collected images of 85 patients. Both the major duodenal papilla and the ostium were then segmented. Afterwards, a neural network was trained using a deep-learning algorithm. A 5-fold cross-validation was performed. Subsequently, we ran the algorithm on 5 prospectively collected videos of ERCPs.
Results
5-fold cross-validation on the 654 labeled data resulted in an F1 value of 0.8007, a sensitivity of 0.8409 and a specificity of 0.9757 for the class papilla, and an F1 value of 0.5724, a sensitivity of 0.5456 and a specificity of 0.9966 for the class ostium. Regardless of the class, the average F1 value (class papilla and class ostium) was 0.6866, the sensitivity 0.6933 and the specificity 0.9861. In 100% of cases the AI-detected localization of the papillary ostium in the prospectively collected videos corresponded to the localization of the cannulation performed by the endoscopist.
Conclusions
In the present study, the neural network was able to identify the major duodenal papilla with a high sensitivity and high specificity. In detecting the papillary ostium, the sensitivity was notably lower. However, when used on videos, the AI was able to identify the location of the subsequent cannulation with 100% accuracy. In the future, the neural network will be trained with more data. Thus, a suitable tool for ERCP could be established, especially in the training situation.
Background
This study evaluated the effect of an artificial intelligence (AI)-based clinical decision support system on the performance and diagnostic confidence of endoscopists in their assessment of Barrett’s esophagus (BE).
Methods
96 standardized endoscopy videos were assessed by 22 endoscopists with varying degrees of BE experience from 12 centers. Assessment was randomized into two video sets: group A (review first without AI and second with AI) and group B (review first with AI and second without AI). Endoscopists were required to evaluate each video for the presence of Barrett’s esophagus-related neoplasia (BERN) and then decide on a spot for a targeted biopsy. After the second assessment, they were allowed to change their clinical decision and confidence level.
Results
AI had a stand-alone sensitivity, specificity, and accuracy of 92.2%, 68.9%, and 81.3%, respectively. Without AI, BE experts had an overall sensitivity, specificity, and accuracy of 83.3%, 58.1%, and 71.5%, respectively. With AI, BE nonexperts showed a significant improvement in sensitivity and specificity when videos were assessed a second time with AI (sensitivity 69.8% [95%CI 65.2%–74.2%] to 78.0% [95%CI 74.0%–82.0%]; specificity 67.3% [95%CI 62.5%–72.2%] to 72.7% [95%CI 68.2%–77.3%]). In addition, the diagnostic confidence of BE nonexperts improved significantly with AI.
Conclusion
BE nonexperts benefitted significantly from additional AI. BE experts and nonexperts remained significantly below the stand-alone performance of AI, suggesting that there may be other factors influencing endoscopists’ decisions to follow or discard AI advice.
Aims
Recent evidence suggests the possibility of intraprocedural phase recognition in surgical operations as well as endoscopic interventions such as peroral endoscopic myotomy and endoscopic submucosal dissection (ESD) by AI-algorithms. The intricate measurement of intraprocedural phase distribution may deepen the understanding of the procedure. Furthermore, real-time quality assessment as well as automation of reporting may become possible. Therefore, we aimed to develop an AI-algorithm for intraprocedural phase recognition during ESD.
Methods
A training dataset of 364385 single images from 9 full-length ESD videos was compiled. Each frame was classified into one procedural phase. Phases included scope manipulation, marking, injection, application of electrical current and bleeding. Allocation of each frame was only possible to one category. This training dataset was used to train a Video Swin transformer to recognize the phases. Temporal information was included via logarithmic frame sampling. Validation was performed using two separate ESD videos with 29801 single frames.
Results
The validation yielded sensitivities of 97.81%, 97.83%, 95.53%, 85.01% and 87.55% for scope manipulation, marking, injection, electric application and bleeding, respectively. Specificities of 77.78%, 90.91%, 95.91%, 93.65% and 84.76% were measured for the same parameters.
Conclusions
The developed algorithm was able to classify full-length ESD videos on a frame-by-frame basis into the predefined classes with high sensitivities and specificities. Future research will aim at the development of quality metrics based on single-operator phase distribution.
The German workshop on medical image computing (BVM) has been held in different locations in Germany for more than 20 years. In terms of content, BVM focused on the computer-aided analysis of medical image data with a wide range of applications, e.g. in the area of imaging, diagnostics, operation planning, computer-aided intervention and visualization.
During this time, there have been remarkable methodological developments and upheavals, on which the BVM community has worked intensively. The area of machine learning should be emphasized, which has led to significant improvements, especially for tasks of classification and segmentation, but increasingly also in image formation and registration. As a result, work in connection with deep learning now dominates the BVM. These developments have also contributed to the establishment of medical image processing at the interface between computer science and medicine as one of the key technologies for the digitization of the health system.
In addition to the presentation of current research results, a central aspect of the BVM is primarily the promotion of young scientists from the diverse BVM community, covering not only Germany but also Austria, Switzerland, The Netherland and other European neighbors. The conference serves primarily doctoral students and postdocs, but also students with excellent bachelor and master theses as a platform to present their work, to enter into professional discourse with the community, and to establish networks with specialist colleagues. Despite the many conferences and congresses that are also relevant for medical image processing, the BVM has therefore lost none of its importance and attractiveness and has retained its permanent place in the annual conference rhythm.
Building on this foundation, there are some innovations and changes this year. The BVM 2021 was organized for the first time at the Ostbayerische Technische Hochschule Regensburg (OTH Regensburg, a technical university of applied sciences). After Aachen, Berlin, Erlangen, Freiburg, Hamburg, Heidelberg, Leipzig, Lübeck, and Munich, Regensburg is not just a new venue. OTH Regensburg is the first representative of the universities of applied sciences (HAW) to organize the conference, which differs to universities, university hospitals, or research centers like Fraunhofer or Helmholtz. This also considers the further development of the research landscape in Germany, where HAWs increasingly contribute to applied research in addition to their focus on teaching. This development is also reflected in the contributions submitted to the BVM in recent years.
At BVM 2021, which was held in a virtual format for the first time due to the Corona pandemic, an attractive and high-quality program was offered. Fortunately, the number of submissions increased significantly. Out of 97 submissions, 26 presentations, 51 posters and 5 software demonstrations were accepted via an anonymized reviewing process with three reviews each. The three best works have been awarded BVM prizes, selected by a separate committee.
Based on these high-quality submissions, we are able to present another special issue in the International Journal of Computer Assisted Radiology and Surgery (IJCARS). Out of the 97 submissions, the ones with the highest scores have been invited to submit an extended version of their paper to be presented in IJCARS. As a result, we are now able to present this special issue with seven excellent articles. Many submissions focus on machine learning in a medical context.
Einleitung:
Blutdruck gilt als sogenannter Vitalparameter als einer der grundlegenden Indikatoren für den Gesundheitszustand einer Person. Sowohl zu niedriger als auch zu hoher Blutdruck kann lebensbedrohend sein, letzerer ist darüber hinaus ein Risikofaktor insbesondere für Herz-Kreislauferkrankungen, die trotz wichtiger Fortschritte in der Behandlung immer noch die häufigste Todesursache in Deutschland darstellen. Die Hämodynamik, also die raumzeitliche Dynamik des Blutflusses, und der Gefäßzustand sind eng verbunden mit dem Blutdruck und ebenfalls von hoher klinischer Relevanz, u.a. zur Identifikation von Durchblutungsstörungen und ungünstigen Druckverteilungen der Gefäßwand. Innovationen in der Messtechnik als auch in der Datenanalyse bieten heute neue Möglichkeiten der Erfassung und Bewertung von Blutdruck, Hämodynamik und Gefäßzustand [1], [2], [3], [4].
Methodik:
In einer gemeinsamen Workshopserie der AG Medizinische Bild- und Signalverarbeitung der GMDS und des Fachausschusses Biosignale der DGBMT werden wir neue Ansätze und Lösungen für Mess- und Analyseverfahren zu Blutdruck und -fluss sowie zum Gefäßzustand vorstellen und diskutieren. Dabei stehen im ersten Workshop auf der GMDS Jahrestagung Bildbasierte Verfahren im Zentrum, während der zweite Workshop auf der DGBMT Jahrestagung den Fokus auf Biosignalbasierten Verfahren legt. Es werden aktuelle Forschungsergebnisse vorgestellt und diskutiert. Es sind jeweils mehrere Vorträge geplant mit ausreichend Zeit zur Diskussion. Folgende Vorträge sind geplant (Arbeitstitel):
Sebastian Zaunseder: Videobasierte Erfassung des Blutdrucks
Anja Hennemuth: A Visualization Toolkit for the Analysis of Aortic Anatomy and Pressure Distribution
Lars Krenkel: Numerische Analyse der Rupturwahrscheinlichkeit zerebraler Aneurysmata
Susanne Schnell: Messung des Blutflusses und hämodynamischer Parameter mit 4D flow MRI: Möglichkeiten und Herausforderungen
Ergebnisse:
Ziel des Workshops ist die Identifikation von innovativen Ansätzen und neuen Methoden zur qualitativen und quantitativen Bestimmung von hämodynamischen Parametern sowie deren kritische Bewertung durch die Community für die Eignung in der klinischen Entscheidungsunterstützung.
Diskussion:
Der Workshop leistet inhaltlich einen Beitrag zu zentralen Aspekten für die Herz-Kreislauf-Medizin. Er bringt dabei Expertise aus verschiedenen Bereichen zusammen und schlägt die Brücke zwischen Kardiologie, Medizininformatik und Medizintechnik.
Schlussfolgerung:
Innovative Technologien aus Medizintechnik und Informatik ermöglichen zunehmend einfache und raumzeitlich aufgelöste Erfassung und Bewertung wichtiger Informationen zur Unterstützung von Diagnose und Therapieverfolgung.
[1] Zaunseder S, Trumpp A, Wedekind D, Malberg H. Cardiovascular assessment by imaging photoplethysmography - a review. Biomed Tech (Berl). 2018 Oct 25;63(5):617–34.
[2] Huellebrand M, Messroghli D, Tautz L, Kuehne T, Hennemuth A. An extensible software platform for interdisciplinary cardiovascular imaging research. Comput Methods Programs Biomed. 2020 Feb;184:105277.
[3] Schmitter S, Adriany G, Waks M, Moeller S, Aristova M, Vali A, et al. Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T. Magn Reson Med. 2020 Oct;84(4):1947–60.
[4] Birkenmaier C, and Krenkel, L. Flow in Artificial Lungs. In: New Results in Numerical and Experimental Fluid Mechanics XIII. Contributions to the 22nd STAB/DGLR Symposium. Springer; 2021.
Semantic segmentation is an essential task in medical imaging research. Many powerful deep-learning-based approaches can be employed for this problem, but they are dependent on the availability of an expansive labeled dataset. In this work, we augment such supervised segmentation models to be suitable for learning from unlabeled data. Our semi-supervised approach, termed Error-Correcting Mean-Teacher, uses an exponential moving average model like the original Mean Teacher but introduces our new paradigm of error correction. The original segmentation network is augmented to handle this secondary correction task. Both tasks build upon the core feature extraction layers of the model. For the correction task, features detected in the input image are fused with features detected in the predicted segmentation and further processed with task-specific decoder layers. The combination of image and segmentation features allows the model to correct present mistakes in the given input pair. The correction task is trained jointly on the labeled data. On unlabeled data, the exponential moving average of the original network corrects the student’s prediction. The combined outputs of the students’ prediction with the teachers’ correction form the basis for the semi-supervised update. We evaluate our method with the 2017 and 2018 Robotic Scene Segmentation data, the ISIC 2017 and the BraTS 2020 Challenges, a proprietary Endoscopic Submucosal Dissection dataset, Cityscapes, and Pascal VOC 2012. Additionally, we analyze the impact of the individual components and examine the behavior when the amount of labeled data varies, with experiments performed on two distinct segmentation architectures. Our method shows improvements in terms of the mean Intersection over Union over the supervised baseline and competing methods. Code is available at https://github.com/CloneRob/ECMT.
Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand.
Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed.
Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure.
Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue.