Refine
Document Type
- conference proceeding (article) (5)
- Article (2)
- Working Paper (2)
- Part of Periodical (1)
- Report (1)
Is part of the Bibliography
- no (11)
Keywords
- TMD (2)
- TMDI (2)
- damping (2)
- inerter (2)
- Forschung (1)
- Forschungsbericht (1)
- optimization (1)
- simulation (1)
- tall building (1)
- vibration (1)
Institute
- Fakultät Elektro- und Informationstechnik (5)
- Laboratory for Safe and Secure Systems (LAS3) (5)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (3)
- Labor Logopädie (LP) (3)
- Regensburg Center of Health Sciences and Technology - RCHST (3)
- Fakultät Maschinenbau (2)
- Hochschulleitung/Hochschulverwaltung (1)
- Institut für Angewandte Forschung und Wirtschaftskooperationen (IAFW) (1)
Begutachtungsstatus
- peer-reviewed (2)
Forschung 2018
(2018)
In recent years, the Tuned Mass Damper with inerter (TMDI) has received significant attention. The inerter is defined to exert a force that is in proportion to the relative acceleration of the two inerter terminals. Here, two TMDI topologies are investigated. The conventional topology is given by the inerter being in parallel to the spring and viscous damper of the TMDI. The other topology is the serial arrangement of spring, inerter and viscous damper being in parallel to the stiffness of the mass spring oscillator of the TMDI. While the first topology intends to increase the inertial force of the TMDI, the second topology aims at producing an additional degree of freedom. The considered TMDI concepts are simulated for harmonic and random excitations, with parameters set according to those described in the literature and with numerically optimized parameters which minimize the primary structure displacement response. The classical TMD is used as a benchmark. The findings are twofold. The conventional TMDI with typical inertance ratio of 1% and the very small value of 0.02% performs significantly worse than the classical TMD with the same mass ratio. In contrast, the TMDI with an additional degree of freedom can improve the mitigation of the primary structure if the inertance ratio is set very small and if the TMDI parameters are numerically optimized.
This study investigates the vibration reduction of tall wind-excited buildings using a tuned mass damper (TMD) with an inerter (TMDI). The performance of the TMDI is computed as a function of the floor to which the inerter is grounded as this parameter strongly influences the vibration reduction of the building and for the case when the inerter is grounded to the earth whereby the absolute acceleration of the corresponding inerter terminal is zero. Simulations are made for broadband and harmonic excitations of the first three bending modes, and the conventional TMD is used as a benchmark. It is found that the inerter performs best when grounded to the earth because, then, the inerter force is in proportion to the absolute acceleration of only the pendulum mass, but not to the relative acceleration of the two inerter terminals, which is demonstrated by the mass matrix. However, if the inerter is grounded to a floor below the pendulum mass, the TMDI only outperforms the TMD if the inerter is grounded to a floor within approximately the first third of the building’s height. For the most realistic case, where the inerter is grounded to a floor in the vicinity of the pendulum mass, the TMDI performs far worse than the classical TMD.
Leitfaden zum Aufbau Praxisbasierter Forschungsnetzwerke (PBFN) in den Gesundheitsfachberufen
(2016)
Dieser forschungsmethodische Leitfaden behandelt folgende Themen:
(1) Wissenschaftlicher Transfer von komplexen Interventionen inkl. Fragestellungen und Methoden von Machbarkeits-, Wirksamkeits- und Implementationsstudien.
(2) Recherchestrategien zur Krankheitslast inkl. Folgen für Betroffene und Gesellschaft und Versorgungsstatus durch Gesundheitsfachberufe.
(3) Präzisierung von Forschungsfragestellungen.
(4) Evidenzrecherche, Evidenzmapping und Beurteilung der Evidenzlage.
(5) Fördermöglichkeiten von Forschungsprojekten.
(6) Forschungsnetzwerke in den Gesundheitsfachberufen.
The safety of electric vehicles has the highest priority because it helps contribute to customer confidence and thereby ensures further growth of the electromobility market. Therefore in series production redundant hardware concepts like dual core microcontrollers running in lock-step-mode are used to reach ASIL D safety requirements given from the ISO 26262. Coded processing is capable of reducing redundancy in hardware by adding diverse redundancy in software, e.g. by specific coding of data and instructions. A system with two coded processing channels is considered. One channel is active and one is in cold standby. When the active channel fails, the service is switched from the active channel to the standby channel. It is imaginable that the two channels with implemented coded processing are running with time redundancy on a single core or on a multi core system where for example different ASIL levels are partitioned on different cores. In this paper a redundant concept based on coded processing and software rejuvenation will be taken into account.