This study investigated whether etoricoxib (COX-II blocker) has a superior efficacy of preventing heterotopic ossification (HO) after total hip arthroplasty (THA) compared to diclofenac (non-selective NSAID). One hundred patients were included (50 in each group) in this single centre, prospective, double-blinded, randomized, controlled trial. Etoricoxib (90 mg) was administered once and diclofenac (75 mg) twice per day for a perioperative period of nine days. The incidence of HO was evaluated on radiographs of the pelvis six months after surgery. Eighty nine of 100 (89 %) patients could be analysed. The overall HO incidence was 37.8 %. There was no significant difference between both study groups. Twelve patients (27.3 %) of the DIC group and 13 patients (28.9 %) of the ETO group showed Brooker grade I ossifications. Five patients (11.4 %) of the DIC and four patients of the ETO (8.9 %) group showed grade II HO formations. No class III or IV HO formations occured in both groups. Ad hoc analysis detected a negative correlation between HO incidence and limited abduction and internal rotation of the hip. Etoricoxib and diclofenac are equally effective for oral HO prophylaxis after primary cementless THA when given for nine peri-operative days to ensure a full recovery and high patient satisfaction.
ObjectiveFemoral head necrosis (FHN) affects mostly young and active people. The most common operative therapy is core decompression (CD) with optional cancellous bone grafting (CBG). Because little information is available on the long-term results of these procedures, we investigated the effectiveness of CD and CD + CBG in patients with ARCO stage II FHN in terms of postoperative pain, range of motion, patient-reported outcome measures (Harris Hip Score, Hip Disability and Osteoarthritis Outcome Score, EuroQol 5D, and Short Form 36 Questionnaire), and disease progression. MethodsWe retrospectively compared 11 patients treated with CD alone 48.0 months (range, 26.3-68.5 months) postoperatively versus 11 patients treated with CD + CBG 69.2 months (range, 38.0-92.9 months) postoperatively. All patients were assessed according to a routine clinical protocol involving a clinical examination, questionnaires, and radiological imaging (X-ray and magnetic resonance imaging). ResultsThe clinical and radiological results showed no significant differences between the two groups. Both interventions demonstrated equal results according to clinical scores. ConclusionsOur data may encourage application of the less invasive technique of CD alone without CBG, which is more surgically demanding. Further prospective studies with longer follow-up are necessary to clarify the risk factors for therapy failure.
Purpose In revision hip arthroplasty, custom-made implants are one option in patients with acetabular Paprosky III defects. Methods In a retrospective analysis, we identified 11 patients undergoing cup revision using a custom-made implant. The accuracy of the intended position of the implant was assessed on post-operative 3D CT and compared to the pre-operative 3D planning in terms of inclination, anteversion, and centre of rotation. In addition, the accuracy of post-operative plain radiographs for measuring implant position was evaluated in relation to the 3D CT standard. Results We found a mean deviation between the planned and the final position of the custom-made acetabular implant on 3D CT of 3.6 degrees +/- 2.8 degrees for inclination and of -1.2 degrees +/- 7.0 degrees for anteversion, respectively. Restoration of center of rotation succeeded with an accuracy of 0.3 mm +/- 3.9 mm in the mediolateral (x) direction, -1.1 mm +/- 3.8 mm in the anteroposterior (y) direction, and 0.4 mm +/- 3.2 mm in the craniocaudal (z) direction. The accuracy of the post-operative plain radiographs in measuring the position of the custom-made implant in relation to 3D CT was 1.1 degrees +/- 1.7 degrees for implant inclination, -2.6 degrees +/- 1.3 degrees for anteversion and 1.3 mm +/- 3.5 mm in the x-direction, and -0.9 mm +/- 3.8 mm in the z-direction for centre of rotation. Conclusion Custom-made acetabular implants can be positioned with good accuracy in Paprosky III defects according to the preoperative planning. Plain radiographs are adequate for assessing implant position in routine follow-up.
Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA ? An Experimental Study
(2017)
Purpose Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between +15 degrees anterior and -15 degrees posterior and 0 degrees to 20 degrees rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results The cup anteversion measured on CT was 23.3 degrees; on AP pelvic radiographs, however, variations in pelvic tilt (+/- 15 degrees) resulted in anteversion angles between 11.0 degrees and 36.2 degrees (mean error 8.3 degrees +/- 3.9 degrees). The cup inclination was 34.1 degrees on CT and ranged between 31.0 degrees and 38.7 degrees (m.e. 2.3 degrees +/- 1.5 degrees) on radiographs. Pelvic rotation between 0 degrees and 20 degrees showed high variation in radiographic anteversion (21.2 degrees-31.2 degrees, m.e. 6.0 degrees +/- 3.1 degrees) and inclination (34.1 degrees-27.2 degrees, m.e. 3.4 degrees +/- 2.5 degrees). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6 degrees +/- 0.2 degrees and in inclination measurements to 0.7 degrees (SD +/- 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4 degrees +/- 0.4 degrees for anteversion and to 1.3 degrees +/- 0.8 for inclination. Conclusion Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools.
Different target areas within the concept of combined cup and stem anteversion have been published for total hip arthroplasty (THA). We asked whether component positioning according to eight standard combined anteversion rules is associated with (1) more physiological gait patterns, (2) higher improvement of gait variables and (3) better clinical outcome after THA.In a prospective clinical study, 60 patients received cementless THA through an anterolateral MIS approach in a lateral decubitus position. Six weeks postoperatively, implant position was analysed using 3D-CT by an independent external institute. Preoperatively, six and 12 months postoperatively range of motion, normalized walking speed and hip flexion symmetry index were measured using 3D motion-capture gait analysis. Patient-related outcome measures (HHS, HOOS, EQ-5D) were obtained by an observer blinded to 3D-CT results. Eight combined anteversion definitions and Lewinnek's "safe zone" were evaluated regarding their impact on gait patterns and clinical outcome.Combined cup and stem anteversion according to standard combined anteversion definitions as well as cup placement within Lewinnek's "safe zone" did not influence range of motion, normalized walking speed and/or hip flexion symmetry index six and 12 months after THA. Similarly, increase of gait parameters within the first year after THA was comparable between all eight combined anteversion rules. Clinical outcome measures like HHS, HOOS and EQ-5D did not show any benefit for either of the combined anteversion definitions.Standard combined cup and stem anteversion rules do not improve postoperative outcome as measured by gait analysis and clinical scores within one year after THA.
Background: Heterotopic ossification (HO) is a complication after tissue trauma, fracture and surgery (i.e. total hip arthroplasty). Prophylaxis is the most effective therapy. If HO formations become symptomatic and limit patients' quality of life, revision surgery is indicated and is usually combined with a perioperative oral prophylaxis (NSAIDs) and/or irradiation. However, a long-term use of NSAIDs can induce gastro-intestinal or cardiac side-effects and possible bony non-unions during fracture healing. Subject of this study was to assess the current status of HO prophylaxis after injuries or fractures and to evaluate current indications and strategies for excision of symptomatic HO. Methods: Between 2013 and 2014, a questionnaire was sent to 119 orthopaedic and trauma surgery departments in Germany. Participation was voluntary and all acquired data was given anonymously. Results: The cumulative feedback rate was 71 %. Trauma and orthopaedic surgery departments in Germany recommend oral HO prophylaxis after acetabulum and femoral neck fractures, elbow dislocation, and fracture or dislocation of the radial head. Pain upon movement and an increasing loss of range of motion in the affected joint are considered to be clear indications for HO surgery. A partial removal of ROM-limiting HO formations was also considered important. The vast majority of all departments include perioperative oral HO prophylaxis and/or irradiation if surgical HO removal is planned. The choice and duration of NSAIDs is highly variable. Conclusion: HO is of clinical significance in current traumatology and orthopaedics. Certain fractures and injuries are prone to HO, and prophylactic measures should be taken. The respondents in this survey assessed current therapeutic strategies for HO formations similarly. These concepts are in line with the literature. However, the duration of perioperative oral HO prophylaxis varied greatly among the specialist centres. This is significant as a long-term use of NSAIDs fosters a potential risk for the patients' safety and could influence the clinical outcome. National and international guidelines need to be developed to further reduce HO rates and improve patients' safety in trauma and orthopaedic surgery.
Introduction Trabecular properties in osteonecrosis of the femoral head (ONFH) are altered for bone volume and structure in the femoral head and proximal femoral canal. We analysed the periprosthetic bone mineral density (BMD) as a correlate to bony ingrowth in patients with ONFH who received a cementless THA. Materials and methods We performed a matched-pair analysis of 100 patients with ONFH (n = 50) and primary osteoarthritis (n = 50) who received the same, unilateral cementless THA. We compared the periprosthetic BMD 5 years after surgery by means of dual energy X-ray absorptiometry (DXA) analysing the seven femoral regions of interest (ROIs) according to Gruen. Results Within the ONFH group, significantly lower BMD values were found in the ROI 1 and 7 (p < 0.05). No statistically significant difference was found for ROIs 2-6. Conclusions An altered periprosthetic bone stock in the proximal femur in patients with prior ONFH might be a possible risk factor for premature loosening of the femoral stem in THA. Surgeons need to consider coating and fixation philosophy of cementless implants when choosing the right stem for patients with ONFH.
In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p aecurrency sign 0.001) and internal rotation (p aecurrency sign 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p aecurrency sign0.034). Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.
A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints.