Refine
Document Type
- Part of a Book (3)
- Article (2)
- conference proceeding (article) (2)
- conference talk (1)
Has Fulltext
- no (8)
Is part of the Bibliography
- no (8)
Keywords
- Dental Pulp (1)
- Dental Pulp Cavity (1)
- Dental Pulp Test (1)
- Dental pulp vitality (1)
- Dentin (1)
- Infrared and terahertz transmission (1)
- Laser-Doppler Flowmetry (1)
- Lentic or flowing blood (1)
- Molar (1)
- Speicherbedarf (1)
Institute
Begutachtungsstatus
- peer-reviewed (2)
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated. The measurements carried out over a wide spectral range, from visible light down to terahertz radiation. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated. The measurements carried out over a wide spectral range, from visible light down to terahertz radiation. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
Transmission spectra of wet human teeth and dentin slices, together with blood of different flow rates were investigated over a wide spectral range, from visible to terahertz (THz) light. The results make it possible to find the optimum light frequency for an all-optical determination of pulpal blood flow and, consequently, for clinically diagnosis of tooth vitality.
PPG signal acquisition and analysis on in vitro tooth model for dental pulp vitality assessmen
(2012)
Energy storage systems (in the past as well as today) are one significant part in the energy supply. The following three chapters describe how storage demand will develop in the future for the electricity, heat, and traffic sectors, as well as for non-energetic consumption of fossil resources (the chemical industry). Chapter 3, the core of this section on storage demand, makes clear how and why the electricity sector is the nucleus of the energy supply of all sectors and why it creates essential bridges between electricity, heat, and transport sectors, as well as with the chemical industry.
If planned electricity network expansion takes place and flexibilities in generation and consumption are fully exploited, the demand for electricity storage, according to present estimates, will only reach a significant scale at 60–80% shares of renewable energy in the power supply. Network expansion has a great impact on the storage demand, as well as flexible power generation in power plants, combined heat and power (CHP), and flexible consumption via demand-side management (DSM). Four studies in the context of storage demand and the role of energy storage systems for flexibility are comprehensively addressed. The authors and the co-authors were themselves participants in these studies, which will be complemented by ongoing research. A meta-study summary of the main results is shown in Abschn. 3.7, and these results are compared with seven further studies.
OBJECTIVES
Due to severe limitations of dental pulp sensitivity tests, the direct recording of pulsed blood flow, using photoplethysmography (PPG), has been proposed. In vivo evaluation is methodologically difficult and in vitro models have hitherto been adversely influenced by shortcomings in emulating the in vivo situation. Consequently, the aim of this study was to test an improved data acquisition system and to use this configuration for recording pulsed blood in a new model.
MATERIALS AND METHODS
We introduced a PPG signal detection system by recording signals under different blood flow conditions at two wavelengths (625 and 940 nm). Pulsed blood flow signals were measured using an in vitro model, containing a molar with a glass pulp and a resin socket, which closely resembled in vivo conditions with regard to volumetric blood flow, pulp anatomy, and surrounding tissue.
RESULTS
The detection system showed improved signal strength without stronger blanketing of noise. On the tooth surface, it was possible to detect signals emanating from pulsed blood flow from the glass pulp and from surrounding tissue at 625 nm. At 940 nm, pulp derived signals were recorded, without interference signals from surrounding tissue.
CONCLUSION
The PPG-based method has the potential to detect pulsed blood flow in small volumes in the pulp and (at 625 nm) also in adjacent tissues.
CLINICAL RELEVANCE
The results show the need for clear differentiation of the spatial origins of blood flow signals of any vitality test method to be applied to teeth.