Networked control systems as e.g., battery management systems, smart grids or vehicular systems, consist of sensors, actuators and controllers with a communication network in the control loop. The data rate and the reliability of the underlying communication network are key factors since delays or message losses directly affect the system control. In addition, the processor load caused by the communication is significant as it influences the calculation of system states and the setting of control parameters. The power consumption of the communication network has a further impact on the energy efficiency of the respective application. In this paper, the communication technologies Controller Area Network (CAN), Controller Area Network Flexible Data-rate (CAN FD) and Ethernet are compared in the context of networked control systems with focus on a decentralized battery management system. First, the message processing time and the processor load are measured. With regard to energy efficiency, the maximum power consumption is determined. The Bit Error Rates (BER) and the Residual Error Rates (RER) are calculated to evaluate the reliability. Finally, the receive FIFO load under high traffic conditions is examined. Index Terms—Networked control systems, decentralized battery management system, microcontrollers, communication systems, Ethernet, Controller Area Network (CAN), Controller Area Network Flexible Data-rate (CAN FD) energy efficiency, energy consumption, bit error rate, residual error rate, processor load.
In a distributed system, functionally equivalent nodes work together to form a system with improved availability, reliability and fault tolerance. Thereby, the purpose is to achieve a common control objective. As multiple components cooperate to accomplish tasks, coordination between them is required. Electing a node as the temporary leader can be a possible solution to perform coordination. This work presents a self-stabilizing algorithm for the election of a leader in dynamically reconfigurable bus topology-based broadcast systems with a message and time complexity of O(1). The election is performed dynamically, i.e., not only when the leader node fails, and is criterion-based. The criterion used is a performance related value which evaluates the properties of the node regarding the ability to perform the tasks of the leader. The increased demands on the leader are taken into account and a re-election is started when the criterion value drops below a predefined level. The goal here is to distribute the load more evenly and to reduce the probability of failure due to overload of individual nodes. For improved system availability and reduced fault rates, a management level consisting of leader, assistant and co-assistant is introduced. This reduces the number of required messages and the duration in case of non-initial election. For further reduction of required messages to uniquely determine a leader, the CAN protocol is exploited. The proposed algorithm selects a node with an improved failure rate and a reduced message and hence time complexity while satisfying the safety and termination constraints. The operation of the algorithm is validated using a hardware test setup.
Control Oriented Mathematical Modeling of a Bidirectional DC-DC Converter - Part 1: Buck Mode
(2023)
Parallel connection of different batteries equipped with bidirectional DC-DC converters offers an increase of the total storage capacity, the provision of higher currents and an improvement of reliability and system availability. To share the load current among the DC-DC converters while maintaining the safe operating range of the batteries, appropriate controllers are needed. The basis for the design of these control approaches requires knowledge of both the static and dynamic characteristics of the DC-DC converter used. In this paper, the small signal analysis of a DC-DC converter in buck mode is shown using the circuit averaging technique. The paper gives an overview of all required transfer functions:. The control and line to output transfer functions for CCM and DCM relevant for average current mode control as well as for voltage control are derived and their poles and zeros are determined. This provides the basis for stability consideration, analysis of the overall control structure and controller design.