We report on a method to stabilize the transmitted electron flux in a field-emission electron source using an external regulation circuit. The electron source was realized with an array of silicon (Si) nanowhiskers on the top of elongated pillar structures, a mica spacer, and an extraction grid made of Si. As for most applications, the emitted electron current from the cathode is not as crucial as the transmitted electron flux through the extraction grid toward the anode. We investigated a method which allows the regulation directly by the emitted electron flux and not merely on the cathode current. By using this method, we were able to stabilize the emitted electron flux of our electron source down to values below 1%. Simultaneously, it was shown that there is the possibility to stabilize the influencing value in the real application as well. The effectiveness of this method was demonstrated successfully with an X-ray source setup. The measured X-ray photon count rate was stabilized to a standard deviation of 0.30% at a pressure of 1 × 10 -7 mbar. Even in harsh environment of 2 × 10 -5 mbar, a stabilization of the X-ray photon count rate down to a value of 0.63% was achieved.
A control circuit to stabilize the flux of electrons transmitted through an extractor electrode is presented. By controlling the emission current a fluctuation with a standard deviation of 0.015% is observed. However, the achievable stability of the transmitted electron current is limited due to a variation of the extraction grid current ratio showing a standard deviation of 4.33%. By regulating the difference of the emission current and the extraction grid current an improved stability of the transmitted electron current down to a standard deviation of 0.280% is observed. Even with operation at 2 × 10 -5 mbar a standard deviation of 0.558% is achieved.