Refine
Year of publication
Document Type
- conference proceeding (article) (1157)
- Article (1020)
- Part of a Book (158)
- conference proceeding (presentation, abstract) (128)
- conference talk (63)
- Preprint (35)
- Report (24)
- Book (15)
- conference proceeding (volume) (8)
- Doctoral Thesis (8)
- Patent (7)
- Working Paper (7)
- Moving Images (5)
- Lecture (4)
- Edited collection (3)
- Other (2)
Language
- English (2644) (remove)
Has Fulltext
- no (2644) (remove)
Is part of the Bibliography
- no (2644)
Keywords
- Simulation (25)
- field emission (24)
- Bildgebendes Verfahren (16)
- Current measurement (15)
- Deep Learning (15)
- silicon (15)
- additive manufacturing (14)
- BEHAVIOR (13)
- Literaturbericht (13)
- simulation (13)
Institute
- Fakultät Informatik und Mathematik (682)
- Fakultät Maschinenbau (646)
- Fakultät Elektro- und Informationstechnik (596)
- Fakultät Angewandte Natur- und Kulturwissenschaften (305)
- Laboratory for Safe and Secure Systems (LAS3) (210)
- Regensburg Center of Biomedical Engineering - RCBE (208)
- Fakultät Bauingenieurwesen (201)
- Labor Biomechanik (LBM) (120)
- Regensburg Medical Image Computing (ReMIC) (117)
- Labor Mikrosensorik (115)
Begutachtungsstatus
- peer-reviewed (1259)
- begutachtet (27)
The present study investigates the interface between carbon steel and titanium samples annealed at different temperatures (𝜗1 = 800 ◦C and 𝜗2 = 1050 ◦C). In both cases, an observable layer forms at the interface, with its thickness increasing from t𝜗1= 2.75 ± 0.15 μm at 800 ◦C to t𝜗2= 8.86 ± 0.29 μm at 1050 ◦C. The layer’s composition and thickness evolve with temperature. Analysis reveals approximately 40 at.-% carbon concentration in the exterior region, indicating likely titanium carbide creation. X-ray diffraction identifies titanium carbide peaks, while microscopy and elemental mapping confirm compositional gradients at the interface.
Electron Backscatter Diffraction (EBSD) shows a gradient in grain size near the TiC surface, reflecting TiC nucleation rates. XRD data detect both titanium carbide and titanium phases, with TiC becoming more prominent at 1050 ◦C. Rietveld analysis further confirms TiC formation. Notably, distinct diffraction patterns on the contact and rear sides suggest a Ti(C, O, N) presence. Depth profiles exhibit varying surface and depth carbon concentrations, attributed to temperature effects. The study successfully demonstrates TiC coating fabrication through hot pressing, wherein Ti(C, O, N) coatings arise from titanium’s affinity for reacting with oxygen and nitrogen. This research contributes to the understanding of phase transformations and interfacial properties in titanium-carbon steel systems.
This article describes a contactless fiber-optic position sensor. It comprises a Polymer Optical Fiber that is grinded to form a D-shaped cross-section with an exposed fiber core. This sensor has two photodiodes at both fiber ends to measure the emitted light intensity. Light is coupled using a red LED at the side face into the exposed core of the fiber at a defined position. The position of the LED at the length of the fiber is measured by calculating the optical power quotient measured by both photodiodes. To test this sensor, Polymer Optical Fibers with different side surface roughness are produced and qualified. Measurements show that the optical power quotient is reproducible and nearly linear over the length of the fiber. It is also seen that the fiber attenuation increases when grinding the fiber side-face with rougher sandpaper. Position measurements show an absolute position error of this sensor in the range of a few millimeters. Microscope images show surface defects along the polished side face of the fiber that are expected to lead to a nonuniform attenuation along the fiber and cause the position errors. Overall, it is proven that this sensor principle works as a contactless low-cost position sensor for short distances with an absolute position standard deviation error lower than 1 mm.
In this work, high-current field emission electron source chips were fabricated using laser-micromachining and MEMS technology. The resulting chips were combined with commercially available printed circuit boards (PCBs) to obtain a multichip electron source. By controlling the separate electron sources using an external current control circuit, we were able to divide the desired total current evenly across the individual chips deployed in the PCB-carrier. In consequence, we were able to show a decreased degradation due to the reduced current load per chip. First, a single electron source chip was measured without current regulation. A steady-state emission current of 1 mA with a high stability of ±1.3% at an extraction voltage of 250 V was observed. At this current level, a mean degradation slope of −0.7 μA/min with a nearly perfect transmission ratio of 99% ± 0.4% was determined. The measurements of a fully assembled multichip PCB-carrier electron source, using a current control circuit for regulation, showed that an even distribution of the desired total current led to a decreased degradation. This was determined by the increase in the required extraction voltage over time. For this purpose, two current levels were applied to the electron source chips of the PCB-carrier using an external current control circuit. First, 300 μA total current was evenly distributed among the individual electron source chips followed by the emission of 300 μA per electron source chip. This allows the observation of the influence of a distributed and nondistributed total current, carried by the electron source chips. Thereby, we obtained an increase in the mean degradation slope from +0.011 V/min (300 μA distributed) to +0.239 V/min (300 μA per chip), which is approximately 21 times higher. Moreover, our current control circuit improved the current stability to under 0.1% for both current levels, 300 μA distributed and 300 μA per chip.
BACKGROUND
Differentiation of high-flow from low-flow vascular malformations (VMs) is crucial for therapeutic management of this orphan disease.
OBJECTIVE
A convolutional neural network (CNN) was evaluated for differentiation of peripheral vascular malformations (VMs) on T2-weighted short tau inversion recovery (STIR) MRI.
METHODS
527 MRIs (386 low-flow and 141 high-flow VMs) were randomly divided into training, validation and test set for this single-center study. 1) Results of the CNN's diagnostic performance were compared with that of two expert and four junior radiologists. 2) The influence of CNN's prediction on the radiologists' performance and diagnostic certainty was evaluated. 3) Junior radiologists' performance after self-training was compared with that of the CNN.
RESULTS
Compared with the expert radiologists the CNN achieved similar accuracy (92% vs. 97%, p = 0.11), sensitivity (80% vs. 93%, p = 0.16) and specificity (97% vs. 100%, p = 0.50). In comparison to the junior radiologists, the CNN had a higher specificity and accuracy (97% vs. 80%, p < 0.001; 92% vs. 77%, p < 0.001). CNN assistance had no significant influence on their diagnostic performance and certainty. After self-training, the junior radiologists' specificity and accuracy improved and were comparable to that of the CNN.
CONCLUSIONS
Diagnostic performance of the CNN for differentiating high-flow from low-flow VM was comparable to that of expert radiologists. CNN did not significantly improve the simulated daily practice of junior radiologists, self-training was more effective.
Analysis and Improvement of Engineering Exams Toward Competence Orientation by Using an AI Chatbot
(2024)
ChatGPT is currently one of the most advanced general chatbots. This development leads to diverse challenges in higher education, like new forms of teaching and learning, additional exam methods, new possibilities for plagiarism, and many more topics. On the other side with the development of advanced AI tools, pure knowledge will be less and less important, and demands from industry will change toward graduates with higher competencies. Education has therefore to be changed from knowledge-centered toward competence centered. The goal of this article is to use ChatGPT for analyzing and improving the competence orientation of exams in engineering education. The authors use ChatGPT to analyze exams from different engineering subjects to evaluate the performance of this chatbot and draw conclusions about the competence orientation of the tested exams. The obtained information is used to develop ideas for increasing the competence orientation of exams. From this analysis, it is visible that ChatGPT gives good performance mainly where knowledge is tested. It has, however, much more problems with transfer questions or tasks where students need creativity or complex insights for finding new solutions. Based on this result, exams and also lectures can be optimized toward competence orientation.
The article presents the process of developing a silicon electron source designed for high-vacuum microelectromechanical system (HV MEMS) devices, i.e., MEMS electron microscope and MEMS x-ray source. Technological constraints and issues of such an electron source are explained. The transition from emitters made of carbon nanotubes to emitters made of pure silicon is described. Overall, the final electron source consists of a silicon tip emitter and a silicon gate electrode integrated on the same glass substrate. The source generates an electron beam without any carbon nanotube coverage. It generates a high and stable electron current and works after the final bonding process of an HV MEMS device.
Microchips are intensively used in almost all nowadays electronic devices. With the continuous advancement of our technologies, they get smaller in size than ever before. They generate high-intensity heat loads that need to be transported effectively such that they may function properly. Heat pipes have proven to be very effective in transporting relatively large heat loads from miniature components. They are of seamless structure that involves a working fluid capable of evaporation and condensation at the working temperature of the electronic chips. The working fluid is derived to move from the condenser to the evaporator via multiple microgrooves using capillary forces. It is important that the condensate reaches the evaporator at a proper rate such that no dry-out or flooding occur. In this work, we are particularly interested in the case of capillary-driven flows in rectangular microchannels. A generalized model is developed that works for axe-symmetric rectangular channels of arbitrary, moderately varying width profiles. It also accounts for any contrast of viscosity between the liquid and the vapor under isothermal conditions. The model shows to reduce to the special case of imbibition in straight and uniform microchannels, for which comparisons with experimental and modeling works show an excellent match. Cases representing linearly and quadratically varying converging/diverging width profiles have been explored. It is found that the viscosity ratio has a significant influence on the rate at which the meniscus advances. The model also negates the common practice found in the literature of using the formula developed for imbibition rates in capillary tubes for rectangular microchannels by replacing the diameter of the tube with the hydraulic diameter. It is also found that the channel profile has an influential effect on the imbibition rates. For tapered microchannels, the capillary force increases along the channel length while it decreases for diverging ones. It is interestingly demonstrated that, for quadratically tapered microchannel, the speed of the meniscus increases towards the end of the microchannel compared with linearly varying microchannels. On the other hand, for diverging microchannels, the speed of the meniscus decreases due to the increase in the cross-sectional area. Computational fluid dynamics (CFD) analysis has been conducted to provide a framework for confirmation and verification for which very good match has been established, which builds confidence in the modeling approach.
Preliminary considerations on the form-finding of a tensegrity joint to be used in dynamic orthoses
(2024)
Small and medium-sized enterprises (SMEs) increasingly need to manage nformation technology (IT) effectively in order to remain competitive. However, compared to larger organizations, SMEs often face challenges in terms of resources and employer attractiveness, and regularly do not have the need to employ a Chief Information Officer (CIO) on a full-time basis. To address this issue, a growing number of global experts have begun to provide CIO services on a part-time basis for multiple clients simultaneously. This approach allows SMEs to tap into the expertise of experienced IT leaders at a fraction of the cost and without committing to long-term arrangements. While these professionals, known as “Fractional CIOs”, have proven their value in the field, there has been a lack of academic research on this emerging trend. Therefore, we carried out a comprehensive research project between 2020 and 2023, involving 62 Fractional CIOs from 10 countries. The research produced a definition, different types of engagements, and success factors for Fractional CIOs and their engagements. This paper summarizes these findings for a wider audience of academics and practitioners.