Filtern
Erscheinungsjahr
Dokumenttyp
- Preprint (42) (entfernen)
Sprache
- Englisch (42) (entfernen)
Gehört zur Bibliographie
- nein (42)
Schlagworte
- acetone (2)
- breath analysis (2)
- 3D breast scan registration (1)
- ADAM Optimizer (1)
- Ars Magna (1)
- Bibliometric Analysis (1)
- Breast imaging (1)
- CNN (1)
- CO2 capture (1)
- Chief Information Officer (1)
Institut
- Fakultät Informatik und Mathematik (18)
- Fakultät Angewandte Natur- und Kulturwissenschaften (11)
- Fakultät Maschinenbau (5)
- Labor Nanoanalytik und Halbleiterchemie (Nanochem) (4)
- Regensburg Medical Image Computing (ReMIC) (4)
- Fakultät Elektro- und Informationstechnik (3)
- Labor für Digitalisierung (LFD) (3)
- Sensorik-Applikationszentrum (SappZ) (3)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (2)
- Fakultät Betriebswirtschaft (2)
Begutachtungsstatus
- peer-reviewed (1)
An Inexpensive Uv-Led Photoacoustic Based Real-Time Sensor-System Detecting Exhaled Trace-Acetone
(2024)
In this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 6.4 ppbV and an NNEA of 1.1E-9 Wcm-1Hz-0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.
Real-time computational speed and a high degree of precision are requirements for computer-assisted interventions. Applying a segmentation network to a medical video processing task can introduce significant inter-frame prediction noise. Existing approaches can reduce inconsistencies by including temporal information but often impose requirements on the architecture or dataset. This paper proposes a method to include temporal information in any segmentation model and, thus, a technique to improve video segmentation performance without alterations during training or additional labeling. With Motion-Corrected Moving Average, we refine the exponential moving average between the current and previous predictions. Using optical flow to estimate the movement between consecutive frames, we can shift the prior term in the moving-average calculation to align with the geometry of the current frame. The optical flow calculation does not require the output of the model and can therefore be performed in parallel, leading to no significant runtime penalty for our approach. We evaluate our approach on two publicly available segmentation datasets and two proprietary endoscopic datasets and show improvements over a baseline approach.
The present paper takes a novel approach to production of fibre-reinforced thermoplastic tubes. The method begins with the raw materials, reinforcing fibre and thermoplastic granulate which are processed to tapes through a newly developed direct impregnation process. It is followed by consolidation of fibre-reinforced thermoplastic tubes using infrared (IR) emitters in the filament winding process. This process employs various angles and utilizes a rotatable consolidation axis. The winding process operates at a constant speed, addressing the challenge of bending the fibre-reinforced tapes in the angle reversal areas near the tube ends. Experiments have confirmed that the process can run at speeds reaching approximately 470 mm/min. The design of the impregnation line takes into account the properties of the thermoplastic and the roving, allowing for a speed of up to 1 m/s.
In a variety of tomographic applications, data cannot be fully acquired, leading to severely underdetermined image reconstruction. Conventional methods result in reconstructions with significant artifacts. In order to remove these artifacts, regularization methods have to be applied that incorporate additional information. An important example is TV reconstruction which is well known to efficiently compensate for missing data and well reduces reconstruction artifacts. At the same time, however, tomographic data is also contaminated by noise, which poses an additional challenge. The use of a single regularizer within a variational regularization framework must therefore account for both the missing data and the noise. However, a single regularizer may not be ideal for both tasks. For example, the TV regularizer is a poor choice for noise reduction over different scales, in which case ℓ1 curvelet regularization methods work well. To address this issue, in this paper we introduce a novel variational regularization framework that combines the advantages of two different regularizers. The basic idea of our framework is to perform reconstruction in two stages, where the first stage mainly aims at accurate reconstruction in the presence of noise, and the second stage aims at artifact reduction. Both reconstruction stages are connected by a data proximity condition. The proposed method is implemented and tested for limited-view CT using a combined curvelet-TV approach. We define and implement a curvelet transform adapted to the limited view problem and demonstrate the advantages of our approach in a series of numerical experiments in this context.
Influence of carbon content on the formation of TiC at diffusion bonded titanium-steel interface
(2023)
Hot pressing of pure Ti and various carbon steels in a temperature range of 950 – 1050 °C creates an up to 9 μm thick compound layer of TiC at the Ti/ steel interface. The calculation of the activation energy for layer formation is 126.5 - 136.7 kJ/mol, independent of the steels carbon content. As the carbon content of the steel increases, the layer thickness also increases, which provides enormous potential for the surface modification of Ti/ Ti-alloys.
Inverse problems are inherently ill-posed and therefore require regularization techniques to achieve a stable solution. While traditional variational methods have wellestablished theoretical foundations, recent advances in machine learning based approaches have shown remarkable practical performance. However, the theoretical foundations of learning-based methods in the context of regularization are still underexplored. In this paper, we propose a general framework that addresses the current gap between learning-based methods and regularization strategies. In particular, our approach emphasizes the crucial role of data consistency in the solution of inverse problems and introduces the concept of data-proximal null-space networks as a key component for their solution. We provide a complete convergence analysis by extending the concept of regularizing null-space networks with data proximity in the visual part. We present numerical results for limited-view computed tomography to illustrate the validity of our framework.
Titanium is used in many areas due to its excellent mechanical, biological and corrosion-resistant properties. Implants often have thin and filigree structures, providing an ideal application for laser fine cutting. In literature, the main focus is primarily on investigating and optimizing the parameters for titanium sheet thicknesses greater than 1 mm. Hence, in this study, the basic manufacturing parameters of laser power, cutting speed and laser pulsing of a 200 W modulated fibre laser are investigated for 0.15 mm thick titanium grade 2 sheets. A reproducible, continuous cut could be achieved using 90 W laserpower and 2 cutting-speed. Pulse pause variations between 85–335 μs in 50 μs steps and fixed
pulse duration of 50 μs show that a minimum kerf width of 23.4 μm, as well as a minimum cut edge roughness Rz of 3.59 μm, is achieved at the lowest pulse pause. An increase in roughness towards the laser exit side, independent of the laser pulse pause, was found and discussed. The results provide initial process parameters for cutting thin titanium sheets and thus provide the basis for further investigations, such as the influence of cutting gas pressure and composition on the cut edge.
Friction has long been an important issue in multibody dynamics. Static friction models apply appropriate regularization techniques to convert the stick inequality and the non-smooth stick-slip transition of Coulomb’s approach into a continuous and smooth function of the sliding velocity. However, a regularized friction force is not able to maintain long-term stick. That is why, dynamic friction models were developed in the last decades. The friction force depends herein not
only on the sliding velocity but also on internal states. The probably best known representative, the LuGre friction model, is based on a fictitious bristle but realizes a too simple approximation. The recently published second order dynamic friction model describes the dynamics of a fictitious bristle more accurately. Its performance is compared here to stick-slip friction models, developed and launched not long ago by commercial multibody software packages.
With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10−9) methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective, is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a five day period at Hohenpeißenberg, Germany. As a reference device a calibrated cavity ringdown spectrometer Picarro G2301 from the meteorological observatory was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to environmental influences. The obtained results show that relaxation effects due to fluctuating environmental conditions, e.g. ambient humidity, are a non-negligible factor in PA sensor systems. Applying algorithm compensation techniques, which are capable of calculating the influence of relaxational effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 % from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.
In this article, we address the challenge of solving the ill-posed reconstruction problem in computed tomography using a translation invariant diagonal frame decomposition (TIDFD). First, we review the concept of a TI-DFD for general linear operators and the corresponding filter-based regularization concept. We then introduce the TI-DFD for the Radon transform on L 2 (R 2) and provide an exemplary construction using the TI wavelet transform. Presented numerical results clearly demonstrate the benefits of our approach over non-translation invariant counterparts.