An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone
(2024)
n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.
An Inexpensive Uv-Led Photoacoustic Based Real-Time Sensor-System Detecting Exhaled Trace-Acetone
(2024)
In this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) – providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 6.4 ppbV and an NNEA of 1.1E-9 Wcm-1Hz-0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.
To decrease the number of kilometers driven during the development of autonomous cars or driving assistance systems, performant simulation tools are necessary. Currently, domain distance effects between simulation and reality are limiting the successful application of rendering engines in data-driven perception tasks. In order to mitigate those domain distance effects, simulation tools have to be as close to reality as possible for the given task. For optical sensors like cameras, the luminance of the scene is essential. We provide within this paper a method to measure the luminance of rendered scenes within CARLA, an often used open-source simulation environment. Thereby, it is possible to validate the environment and weather models by taking real-world measurements with photometric sensors or with the help of open-source weather data, published e.g. by the German federal service for weather data (DWD - "Deutscher Wetterdienst"). Employing our proposed luminance measurement, the domain gap resulting from the simulation can be specified, which makes it possible to evaluate the statements about the safety of the automated driving system determined within the simulation. We show that the ratio between global and diffuse radiation modeled by the default atmosphere models within CARLA are under limited conditions similar to real-world measurements taken by the DWD. Nevertheless, we show, that the ratio’s temporal variability in real-world situations is not modeled by CARLA.
With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10−9), methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a 5 d period at Hohenpeißenberg, Germany. As a reference device, a calibrated cavity ring-down spectrometer, Picarro G2301, from the meteorological observatory of the German Weather Service (DWD) was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to fluctuating environmental conditions, e.g. ambient humidity. The obtained results show that for PA sensor systems non-radiative relaxation effects induced by varying humidity are a non-negligible factor. Applying algorithm compensation techniques, which are capable of calculating the influence of non-radiative relaxation effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 % from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.
Artificial neural networks (ANNs) are used in quantitative infrared gas spectroscopy to predict concentrations on multi-component absorption spectra. Training of ANNs requires vast amounts of labelled training data which may be elaborate and time consuming to obtain. Additional data can be gained by the utilization of synthetically generated spectra, but at the cost of systematic deviations to measured data. Here, we present two approaches to train ANNs with a combination of comparatively small, measured data sets and synthetically generated data. For the first approach a neural network is trained hybridly with synthetically generated infrared absorption spectra of mixtures of N2O and CO and measured zero-gas spectra, taken with a mid-infrared dual comb spectrometer. This improves the mean absolute error (MAE) of the network predictions from 0.46 to 0.01 ppmV and 0.24 to 0.01 ppmV for the concentration predictions of N2O and CO respectively for zero-gas measurements which was previously observed for training with purely synthetic data. At the same time a similar performance on spectra from gas mixtures of 0–100 ppmV N2O and 0 to 60 ppmV CO was achieved. For the second approach an ANN pre-trained on synthetic infrared spectra of mixtures of acetone and ethanol is retrained on a small dataset consisting of 26 spectra taken with a mid-infrared photoacoustic spectrometer. In this case the MAE for the concentration predictions of ethanol and acetone are improved by 45 % and 20 % in comparison to purely synthetic training. This shows the capability of using synthetically generated data to train ANNs in combination with small amounts of measured data to further improve neural networks for gas sensing and the transferability between different sensing approaches.
A comparative analysis of two different approaches developed to deal with molecular relaxation in photoacoustic spectroscopy is here reported. The first method employs a statistical analysis based on partial least squares regression, while the second method relies on the development of a digital twin of the photoacoustic sensor based on the theoretical modelling of the occurring relaxations. Methane detection within a gas matrix of synthetic air with variable humidity level is selected as case study. An interband cascade laser emitting at 3.345 µm is used to target methane absorption features. Two methane concentration ranges are explored targeting different absorptions, one in the order of part-per-million and one in the order of percent, while water vapor absolute concentration was varied from 0.3 % up to 2 %. The results achieved employing the detection techniques demonstrated the possibility to efficiently retrieve the target gas concentrations with accuracy > 95 % even in the case of strong influence of relaxation effects.
In process analytics or environmental monitoring, the real-time recording of the composition of complex samples over a long period of time presents a great challenge. Promising solutions are label-free techniques such as surface plasmon resonance (SPR) spectroscopy. They are, however, often limited due to poor reversibility of analyte binding. In this work, we introduce how SPR imaging in combination with a semi-selective functional surface and smart data analysis can identify small and chemically similar molecules. Our sensor uses individual functional spots made from different ratios of graphene oxide and reduced graphene oxide, which generate a unique signal pattern depending on the analyte due to different binding affinities. These patterns allow four purine bases to be distinguished after classification using a convolutional neural network (CNN) at concentrations as low as 50 μM. The validation and test set classification accuracies were constant across multiple measurements on multiple sensors using a standard CNN, which promises to serve as a future method for developing online sensors in complex mixtures.
Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8260 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbV in terms of ethanol and 250 pptV regarding acetone, our system is among the best performing presented so far.
With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10−9) methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective, is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a five day period at Hohenpeißenberg, Germany. As a reference device a calibrated cavity ringdown spectrometer Picarro G2301 from the meteorological observatory was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to environmental influences. The obtained results show that relaxation effects due to fluctuating environmental conditions, e.g. ambient humidity, are a non-negligible factor in PA sensor systems. Applying algorithm compensation techniques, which are capable of calculating the influence of relaxational effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 % from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.