TY - CHAP A1 - Rauber, David A1 - Mendel, Robert A1 - Scheppach, Markus W. A1 - Ebigbo, Alanna A1 - Messmann, Helmut A1 - Palm, Christoph T1 - Analysis of Celiac Disease with Multimodal Deep Learning T2 - Bildverarbeitung für die Medizin 2022: Proceedings, German Workshop on Medical Image Computing, Heidelberg, June 26-28, 2022 N2 - Celiac disease is an autoimmune disorder caused by gluten that results in an inflammatory response of the small intestine.We investigated whether celiac disease can be detected using endoscopic images through a deep learning approach. The results show that additional clinical parameters can improve the classification accuracy. In this work, we distinguished between healthy tissue and Marsh III, according to the Marsh score system. We first trained a baseline network to classify endoscopic images of the small bowel into these two classes and then augmented the approach with a multimodality component that took the antibody status into account. KW - Deep Learning KW - Endoscopy Y1 - 2022 U6 - https://doi.org/10.1007/978-3-658-36932-3_25 SP - 115 EP - 120 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Weber, Joachim A1 - Brawanski, Alexander A1 - Palm, Christoph T1 - Parallelization of FSL-Fast segmentation of MRI brain data T2 - 58. Jahrestagung der Deutschen Gesellschaft für Medizinische Informatik, Biometrie und Epidemiologie e.V. (GMDS 2013), Lübeck, 01.-05.09.2013 Y1 - 2013 U6 - https://doi.org/10.3205/13gmds261 N1 - Meeting Abstract IS - DocAbstr. 329 PB - German Medical Science GMS Publishing House CY - Düsseldorf ER - TY - GEN ED - Lehmann, Thomas M. ED - Palm, Christoph ED - Spitzer, Klaus ED - Tolxdorff, Thomas T1 - Advances in Quantitative Laryngoscopy, Voice and Speech Research, Procs. 3rd International Workshop, RWTH Aachen Y1 - 1998 CY - Aachen ER - TY - JOUR A1 - Huber, Michaela A1 - Schlosser, Daniela A1 - Stenzel, Susanne A1 - Maier, Johannes A1 - Pattappa, Girish A1 - Kujat, Richard A1 - Striegl, Birgit A1 - Docheva, Denitsa T1 - Quantitative Analysis of Surface Contouring with Pulsed Bipolar Radiofrequency on Thin Chondromalacic Cartilage JF - BioMed Research International N2 - The purpose of this study was to evaluate the quality of surface contouring of chondromalacic cartilage by bipolar radio frequency energy using different treatment patterns in an animal model, as well as examining the impact of the treatment onto chondrocyte viability by two different methods. Our experiments were conducted on 36 fresh osteochondral sections from the tibia plateau of slaughtered 6-month-old pigs, where the thickness of the cartilage is similar to that of human wrist cartilage. An area of 1 cm(2) was first treated with emery paper to simulate the chondromalacic cartilage. Then, the treatment with RFE followed in 6 different patterns. The osteochondral sections were assessed for cellular viability (live/dead assay, caspase (cell apoptosis marker) staining, and quantitative analysed images obtained by fluorescent microscopy). For a quantitative characterization of none or treated cartilage surfaces, various roughness parameters were measured using confocal laser scanning microscopy (Olympus LEXT OLS 4000 3D). To describe the roughness, the Root-Mean-Square parameter (Sq) was calculated. A smoothing effect of the cartilage surface was detectable upon each pattern of RFE treatment. The Sq for native cartilage was Sq=3.8 +/- 1.1 mu m. The best smoothing pattern was seen for two RFE passes and a 2-second pulsed mode (B2p2) with an Sq=27.3 +/- 4.9 mu m. However, with increased smoothing, an augmentation in chondrocyte death up to 95% was detected. Using bipolar RFE treatment in arthroscopy for small joints like the wrist or MCP joints should be used with caution. In the case of chondroplasty, there is a high chance to destroy the joint cartilage. KW - CHONDROCYTE DEATH KW - energy KW - HUMAN ARTICULAR-CARTILAGE KW - MONOPOLAR KW - THERMAL CHONDROPLASTY Y1 - 2020 U6 - https://doi.org/10.1155/2020/1242086 SP - 1 EP - 8 PB - HINDAWI ER - TY - CHAP A1 - Palm, Christoph A1 - Siegmund, Heiko A1 - Semmelmann, Matthias A1 - Grafe, Claudia A1 - Evert, Matthias A1 - Schroeder, Josef A. T1 - Interactive Computer-assisted Approach for Evaluation of Ultrastructural Cilia Abnormalities T2 - Medical Imaging 2016: Computer-Aided Diagnosis, San Diego, California, United States, 27 February - 3 March, SPIE Proceedings 97853N, 2016, ISBN 9781510600201 N2 - Introduction – Diagnosis of abnormal cilia function is based on ultrastructural analysis of axoneme defects, especialy the features of inner and outer dynein arms which are the motors of ciliar motility. Sub-optimal biopsy material, methodical, and intrinsic electron microscopy factors pose difficulty in ciliary defects evaluation. We present a computer-assisted approach based on state-of-the-art image analysis and object recognition methods yielding a time-saving and efficient diagnosis of cilia dysfunction. Method – The presented approach is based on a pipeline of basal image processing methods like smoothing, thresholding and ellipse fitting. However, integration of application specific knowledge results in robust segmentations even in cases of image artifacts. The method is build hierarchically starting with the detection of cilia within the image, followed by the detection of nine doublets within each analyzable cilium, and ending with the detection of dynein arms of each doublet. The process is concluded by a rough classification of the dynein arms as basis for a computer-assisted diagnosis. Additionally, the interaction possibilities are designed in a way, that the results are still reproducible given the completion report. Results – A qualitative evaluation showed reasonable detection results for cilia, doublets and dynein arms. However, since a ground truth is missing, the variation of the computer-assisted diagnosis should be within the subjective bias of human diagnosticians. The results of a first quantitative evaluation with five human experts and six images with 12 analyzable cilia showed, that with default parameterization 91.6% of the cilia and 98% of the doublets were found. The computer-assisted approach rated 66% of those inner and outer dynein arms correct, where all human experts agree. However, especially the quality of the dynein arm classification may be improved in future work. KW - Image analysis KW - Image processing KW - Computer aided diagnosis and therapy KW - Image classification KW - Image segmentation KW - Biopsy KW - Electron microscopy KW - Zilie KW - Ultrastruktur KW - Anomalie KW - Bildverarbeitung KW - Objekterkennung KW - Computerunterstütztes Verfahren Y1 - 2016 U6 - https://doi.org/10.1117/12.2214976 ER - TY - JOUR A1 - Hutterer, Markus A1 - Hattingen, Elke A1 - Palm, Christoph A1 - Proescholdt, Martin Andreas A1 - Hau, Peter T1 - Current standards and new concepts in MRI and PET response assessment of antiangiogenic therapies in high-grade glioma patients JF - Neuro-Oncology N2 - Despite multimodal treatment, the prognosis of high-grade gliomas is grim. As tumor growth is critically dependent on new blood vessel formation, antiangiogenic treatment approaches offer an innovative treatment strategy. Bevacizumab, a humanized monoclonal antibody, has been in the spotlight of antiangiogenic approaches for several years. Currently, MRI including contrast-enhanced T1-weighted and T2/fluid-attenuated inversion recovery (FLAIR) images is routinely used to evaluate antiangiogenic treatment response (Response Assessment in Neuro-Oncology criteria). However, by restoring the blood–brain barrier, bevacizumab may reduce T1 contrast enhancement and T2/FLAIR hyperintensity, thereby obscuring the imaging-based detection of progression. The aim of this review is to highlight the recent role of imaging biomarkers from MR and PET imaging on measurement of disease progression and treatment effectiveness in antiangiogenic therapies. Based on the reviewed studies, multimodal imaging combining standard MRI with new physiological MRI techniques and metabolic PET imaging, in particular amino acid tracers, may have the ability to detect antiangiogenic drug susceptibility or resistance prior to morphological changes. As advances occur in the development of therapies that target specific biochemical or molecular pathways and alter tumor physiology in potentially predictable ways, the validation of physiological and metabolic imaging biomarkers will become increasingly important in the near future. KW - High-grade glioma KW - Antiangiogenic treatment KW - MRI KW - PET KW - Multimodal response assessment KW - Gliom KW - Antiangiogenese KW - Bildgebendes Verfahren KW - Biomarker Y1 - 2015 U6 - https://doi.org/10.1093/neuonc/nou322 VL - 17 IS - 6 SP - 784 EP - 800 ER - TY - CHAP A1 - Mendel, Robert A1 - Rauber, David A1 - Palm, Christoph T1 - Exploring the Effects of Contrastive Learning on Homogeneous Medical Image Data T2 - Bildverarbeitung für die Medizin 2023: Proceedings, German Workshop on Medical Image Computing, July 2– 4, 2023, Braunschweig N2 - We investigate contrastive learning in a multi-task learning setting classifying and segmenting early Barrett’s cancer. How can contrastive learning be applied in a domain with few classes and low inter-class and inter-sample variance, potentially enabling image retrieval or image attribution? We introduce a data sampling strategy that mines per-lesion data for positive samples and keeps a queue of the recent projections as negative samples. We propose a masking strategy for the NT-Xent loss that keeps the negative set pure and removes samples from the same lesion. We show cohesion and uniqueness improvements of the proposed method in feature space. The introduction of the auxiliary objective does not affect the performance but adds the ability to indicate similarity between lesions. Therefore, the approach could enable downstream auto-documentation tasks on homogeneous medical image data. Y1 - 2023 U6 - https://doi.org/10.1007/978-3-658-41657-7 SP - 128 EP - 13 PB - Springer Vieweg CY - Wiesbaden ER - TY - GEN ED - Palm, Christoph ED - Deserno, Thomas M. ED - Handels, Heinz ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Tolxdorff, Thomas T1 - Bildverarbeitung für die Medizin 2021 BT - Proceedings, German Workshop on Medical Image Computing, Regensburg, March 7–9, 2021 N2 - In den letzten Jahren hat sich der Workshop "Bildverarbeitung für die Medizin" durch erfolgreiche Veranstaltungen etabliert. Ziel ist auch 2021 wieder die Darstellung aktueller Forschungsergebnisse und die Vertiefung der Gespräche zwischen Wissenschaftlern, Industrie und Anwendern. Die Beiträge dieses Bandes - einige davon in englischer Sprache - umfassen alle Bereiche der medizinischen Bildverarbeitung, insbesondere Bildgebung und -akquisition, Maschinelles Lernen, Bildsegmentierung und Bildanalyse, Visualisierung und Animation, Zeitreihenanalyse, Computerunterstützte Diagnose, Biomechanische Modellierung, Validierung und Qualitätssicherung, Bildverarbeitung in der Telemedizin u.v.m. KW - Bildanalyse KW - Bildverarbeitung KW - Computerunterstützte Medizin KW - Deep Learning KW - Visualisierung Y1 - 2021 SN - 978-3-658-33197-9 U6 - https://doi.org/10.1007/978-3-658-33198-6 SN - 1431-472X PB - Springer Vieweg CY - Wiesbdaden ER - TY - GEN A1 - Mendel, Robert A1 - Souza Jr., Luis Antonio de A1 - Rauber, David A1 - Papa, João Paulo A1 - Palm, Christoph T1 - Abstract: Semi-supervised Segmentation Based on Error-correcting Supervision T2 - Bildverarbeitung für die Medizin 2021. Proceedings, German Workshop on Medical Image Computing, Regensburg, March 7-9, 2021 N2 - Pixel-level classification is an essential part of computer vision. For learning from labeled data, many powerful deep learning models have been developed recently. In this work, we augment such supervised segmentation models by allowing them to learn from unlabeled data. Our semi-supervised approach, termed Error-Correcting Supervision, leverages a collaborative strategy. Apart from the supervised training on the labeled data, the segmentation network is judged by an additional network. KW - Deep Learning Y1 - 2021 SN - 978-3-658-33197-9 U6 - https://doi.org/10.1007/978-3-658-33198-6_43 SP - 178 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Barrett esophagus: What to expect from Artificial Intelligence? JF - Best Practice & Research Clinical Gastroenterology N2 - The evaluation and assessment of Barrett’s esophagus is challenging for both expert and nonexpert endoscopists. However, the early diagnosis of cancer in Barrett’s esophagus is crucial for its prognosis, and could save costs. Pre-clinical and clinical studies on the application of Artificial Intelligence (AI) in Barrett’s esophagus have shown promising results. In this review, we focus on the current challenges and future perspectives of implementing AI systems in the management of patients with Barrett’s esophagus. KW - Deep Learning KW - Künstliche Intelligenz KW - Computerunterstützte Medizin KW - Barrett KW - Adenocarcinoma KW - Artificial intelligence KW - Deep learning KW - Convolutional neural networks Y1 - 2021 U6 - https://doi.org/10.1016/j.bpg.2021.101726 SN - 1521-6918 VL - 52-53 IS - June-August PB - Elsevier ER - TY - JOUR A1 - Maier, Andreas A1 - Deserno, Thomas M. A1 - Handels, Heinz A1 - Maier-Hein, Klaus H. A1 - Palm, Christoph A1 - Tolxdorff, Thomas T1 - Guest editorial of the IJCARS - BVM 2018 special issue JF - International Journal of Computer Assisted Radiology and Surgery KW - Medical Image Computing Y1 - 2019 U6 - https://doi.org/10.1007/s11548-018-01902-0 VL - 14 SP - 1 EP - 2 PB - Springer ER - TY - JOUR A1 - Passos, Leandro A. A1 - Souza Jr., Luis Antonio de A1 - Mendel, Robert A1 - Ebigbo, Alanna A1 - Probst, Andreas A1 - Messmann, Helmut A1 - Palm, Christoph A1 - Papa, João Paulo T1 - Barrett's esophagus analysis using infinity Restricted Boltzmann Machines JF - Journal of Visual Communication and Image Representation N2 - The number of patients with Barret’s esophagus (BE) has increased in the last decades. Considering the dangerousness of the disease and its evolution to adenocarcinoma, an early diagnosis of BE may provide a high probability of cancer remission. However, limitations regarding traditional methods of detection and management of BE demand alternative solutions. As such, computer-aided tools have been recently used to assist in this problem, but the challenge still persists. To manage the problem, we introduce the infinity Restricted Boltzmann Machines (iRBMs) to the task of automatic identification of Barrett’s esophagus from endoscopic images of the lower esophagus. Moreover, since iRBM requires a proper selection of its meta-parameters, we also present a discriminative iRBM fine-tuning using six meta-heuristic optimization techniques. We showed that iRBMs are suitable for the context since it provides competitive results, as well as the meta-heuristic techniques showed to be appropriate for such task. KW - Speiseröhrenkrankheit KW - Diagnose KW - Boltzmann-Maschine KW - Barrett’s esophagus KW - Infinity Restricted Boltzmann Machines KW - Meta-heuristics KW - Deep learning KW - Metaheuristik KW - Maschinelles Lernen Y1 - 2019 U6 - https://doi.org/10.1016/j.jvcir.2019.01.043 VL - 59 SP - 475 EP - 485 PB - Elsevier ER - TY - CHAP A1 - Souza Jr., Luis Antonio de A1 - Afonso, Luis Claudio Sugi A1 - Palm, Christoph A1 - Papa, João Paulo T1 - Barrett's Esophagus Identification Using Optimum-Path Forest T2 - Proceedings of the 30th Conference on Graphics, Patterns and Images Tutorials (SIBGRAPI-T 2017), Niterói, Rio de Janeiro, Brazil, 2017, 17-20 October N2 - Computer-assisted analysis of endoscopic images can be helpful to the automatic diagnosis and classification of neoplastic lesions. Barrett's esophagus (BE) is a common type of reflux that is not straight forward to be detected by endoscopic surveillance, thus being way susceptible to erroneous diagnosis, which can cause cancer when not treated properly. In this work, we introduce the Optimum-Path Forest (OPF) classifier to the task of automatic identification of Barrett'sesophagus, with promising results and outperforming the well known Support Vector Machines (SVM) in the aforementioned context. We consider describing endoscopic images by means of feature extractors based on key point information, such as the Speeded up Robust Features (SURF) and Scale-Invariant Feature Transform (SIFT), for further designing a bag-of-visual-wordsthat is used to feed both OPF and SVM classifiers. The best results were obtained by means of the OPF classifier for both feature extractors, with values lying on 0.732 (SURF) - 0.735(SIFT) for sensitivity, 0.782 (SURF) - 0.806 (SIFT) for specificity, and 0.738 (SURF) - 0.732 (SIFT) for the accuracy. KW - Speiseröhrenkrankheit KW - Diagnose KW - Maschinelles Lernen KW - Bilderkennung KW - Automatische Klassifikation Y1 - 2017 U6 - https://doi.org/10.1109/SIBGRAPI.2017.47 SP - 308 EP - 314 ER - TY - CHAP A1 - Zehner, Alexander A1 - Szalo, Alexander Eduard A1 - Palm, Christoph T1 - GraphMIC: Easy Prototyping of Medical Image Computing Applications T2 - Interactive Medical Image Computing (IMIC), Workshop at the Medical Image Computing and Computer Assisted Interventions (MICCAI 2015), 2015, Munich N2 - GraphMIC is a cross-platform image processing application utilizing the libraries ITK and OpenCV. The abstract structure of image processing pipelines is visually represented by user interface components based on modern QtQuick technology and allows users to focus on arrangement and parameterization of operations rather than implementing the equivalent functionality natively in C++. The application's central goal is to improve and simplify the typical workflow by providing various high level features and functions like multi threading, image sequence processing and advanced error handling. A built-in python interpreter allows the creation of custom nodes, where user defined algorithms can be integrated to extend basic functionality. An embedded 2d/3d visual-izer gives feedback of the resulting image of an operation or the whole pipeline. User inputs like seed points, contours or regions are forwarded to the processing pipeline as parameters to offer semi-automatic image computing. We report the main concept of the application and introduce several features and their implementation. Finally, the current state of development as well as future perspectives of GraphMIC are discussed KW - Bildverarbeitung KW - Medizin Y1 - 2015 U6 - https://doi.org/10.13140/RG.2.1.3718.4725 N1 - Open-Access-Publikation SP - 395 EP - 400 ER - TY - CHAP A1 - Weber, Joachim A1 - Doenitz, Christian A1 - Brawanski, Alexander A1 - Palm, Christoph T1 - Data-Parallel MRI Brain Segmentation in Clinicial Use BT - Porting FSL-Fastv4 to GPGPUs T2 - Bildverarbeitung für die Medizin 2015; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 15. bis 17. März 2015 in Lübeck N2 - Structural MRI brain analysis and segmentation is a crucial part in the daily routine in neurosurgery for intervention planning. Exemplarily, the free software FSL-FAST (FMRIB’s Segmentation Library – FMRIB’s Automated Segmentation Tool) in version 4 is used for segmentation of brain tissue types. To speed up the segmentation procedure by parallel execution, we transferred FSL-FAST to a General Purpose Graphics Processing Unit (GPGPU) using Open Computing Language (OpenCL) [1]. The necessary steps for parallelization resulted in substantially different and less useful results. Therefore, the underlying methods were revised and adapted yielding computational overhead. Nevertheless, we achieved a speed-up factor of 3.59 from CPU to GPGPU execution, as well providing similar useful or even better results. KW - Brain Segmentation KW - Magnetic Resonance Imaging KW - Parallel Execution KW - Voxel Spacing KW - General Purpose Graphic Processing Unit KW - Kernspintomografie KW - Gehirn KW - Bildsegmentierung KW - Parallelverarbeitung Y1 - 2015 U6 - https://doi.org/10.1007/978-3-662-46224-9_67 SP - 389 EP - 394 PB - Springer CY - Berlin ER - TY - GEN A1 - Maier, Johannes A1 - Weiherer, Maximilian A1 - Huber, Michaela A1 - Palm, Christoph ED - Handels, Heinz ED - Deserno, Thomas M. ED - Maier, Andreas ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Abstract: Imitating Human Soft Tissue with Dual-Material 3D Printing T2 - Bildverarbeitung für die Medizin 2019, Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 17. bis 19. März 2019 in Lübeck N2 - Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. KW - Handchirurgie KW - 3D-Druck KW - Lernprogramm KW - HaptiVisT Y1 - 2019 SN - 978-3-658-25325-7 U6 - https://doi.org/10.1007/978-3-658-25326-4_48 SP - 218 PB - Springer Vieweg CY - Wiesbaden ER - TY - GEN ED - Maier, Andreas ED - Deserno, Thomas M. ED - Handels, Heinz ED - Maier-Hein, Klaus H. ED - Palm, Christoph ED - Tolxdorff, Thomas T1 - Bildverarbeitung für die Medizin 2024 BT - Proceedings, German Workshop on Medical Image Computing, Erlangen, March 10-12, 2024 N2 - Seit mehr als 25 Jahren ist der Workshop "Bildverarbeitung für die Medizin" als erfolgreiche Veranstaltung etabliert. Ziel ist auch 2024 wieder die Darstellung aktueller Forschungsergebnisse und die Vertiefung der Gespräche zwischen Wissenschaftlern, Industrie und Anwendern. Die Beiträge dieses Bandes - viele davon in englischer Sprache - umfassen alle Bereiche der medizinischen Bildverarbeitung, insbesondere die Bildgebung und -akquisition, Segmentierung und Analyse, Visualisierung und Animation, computerunterstützte Diagnose sowie bildgestützte Therapieplanung und Therapie. Hierbei kommen Methoden des maschinelles Lernens, der biomechanischen Modellierung sowie der Validierung und Qualitätssicherung zum Einsatz. KW - Bildverarbeitung KW - Computerunterstützte Medizin KW - Bildgebendes Verfahren KW - Bildanalyse KW - Deep Learning Y1 - 2024 SN - 978-3-658-44037-4 U6 - https://doi.org/10.1007/978-3-658-44037-4 SN - 1431-472X PB - Springer CY - Wiesbaden ER - TY - GEN A1 - Rückert, Tobias A1 - Rieder, Maximilian A1 - Rauber, David A1 - Xiao, Michel A1 - Humolli, Eg A1 - Feussner, Hubertus A1 - Wilhelm, Dirk A1 - Palm, Christoph T1 - Augmenting instrument segmentation in video sequences of minimally invasive surgery by synthetic smoky frames T2 - International Journal of Computer Assisted Radiology and Surgery KW - Surgical instrument segmentation KW - smoke simulation KW - unpaired image-to-image translation KW - robot-assisted surgery Y1 - 2023 U6 - https://doi.org/10.1007/s11548-023-02878-2 VL - 18 IS - Suppl 1 SP - S54 EP - S56 PB - Springer Nature ER - TY - JOUR A1 - Maerkl, Raphaela A1 - Rueckert, Tobias A1 - Rauber, David A1 - Gutbrod, Max A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - Enhancing generalization in zero-shot multi-label endoscopic instrument classification JF - International Journal of Computer Assisted Radiology and Surgery N2 - Purpose Recognizing previously unseen classes with neural networks is a significant challenge due to their limited generalization capabilities. This issue is particularly critical in safety-critical domains such as medical applications, where accurate classification is essential for reliability and patient safety. Zero-shot learning methods address this challenge by utilizing additional semantic data, with their performance relying heavily on the quality of the generated embeddings. Methods This work investigates the use of full descriptive sentences, generated by a Sentence-BERT model, as class representations, compared to simpler category-based word embeddings derived from a BERT model. Additionally, the impact of z-score normalization as a post-processing step on these embeddings is explored. The proposed approach is evaluated on a multi-label generalized zero-shot learning task, focusing on the recognition of surgical instruments in endoscopic images from minimally invasive cholecystectomies. Results The results demonstrate that combining sentence embeddings and z-score normalization significantly improves model performance. For unseen classes, the AUROC improves from 43.9% to 64.9%, and the multi-label accuracy from 26.1% to 79.5%. Overall performance measured across both seen and unseen classes improves from 49.3% to 64.9% in AUROC and from 37.3% to 65.1% in multi-label accuracy, highlighting the effectiveness of our approach. Conclusion These findings demonstrate that sentence embeddings and z-score normalization can substantially enhance the generalization performance of zero-shot learning models. However, as the study is based on a single dataset, future work should validate the method across diverse datasets and application domains to establish its robustness and broader applicability. KW - Generalized zero-shot learning KW - Sentence embeddings KW - Z-score normalization KW - Multi-label classification KW - Surgical instruments Y1 - 2025 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-85674 N1 - Corresponding author der OTH Regensburg: Raphaela Maerkl VL - 20 SP - 1577 EP - 1587 PB - Springer Nature ER - TY - GEN A1 - Scheppach, Markus W. A1 - Weber Nunes, Danilo A1 - Rauber, David A1 - Arizi, X. A1 - Probst, Andreas A1 - Nagl, Sandra A1 - Römmele, Christoph A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Künstliche Intelligenz-basierte Erkennung von interventionellen Phasen bei der endoskopischen Submukosadissektion T2 - Zeitschrift für Gastroenterologie N2 - Einleitung: Die endoskopische Submukosadissektion (ESD) ist ein komplexes endoskopisches Verfahren, das technische Expertise erfordert. Objektive Methoden zur Analyse von interventionellen Abläufen bei ESD könnten für Qualitätssicherung und Ausbildung, wie auch eine automatische Befunderstellung von Nutzen sein. Ziele: In dieser Studie wurde ein KI-Algorithmus für die Erkennung und Klassifizierung der interventionellen Phasen der ESD entwickelt, um die technische Basis für eine standardisierte Leistungsbewertung und automatische Befunderstellung zu schaffen. Methodik: Vollständige ESD-Videoaufnahmen von 49 Patienten wurden retrospektiv zusammengestellt. Der Datensatz umfasste 6.390.151 Einzelbilder, die alle für die folgenden interventionellen Phasen annotiert wurden: Diagnostik, Markierung, Injektion, Dissektion und Hämostase. 3.973.712 Bilder (28 Patienten) wurden für das Training eines Video-Swin-Transformers genutzt. Dabei wurde temporale Information durch standardisierte BIldextraktion in festgelegten zeitlichen Abständen zum analysierten Bild inkorporiert. 2.416.439 separate Bilder (21 Patienten) wurden für eine interne Validierung genutzt. Ergebnis: Bei der internen Evaluation erreichte das System insgesamt einen F1-Wert von 0,88. Es wurden F1-Werte von 0,99, 0,89, 0,89, 0,91 und 0,52 für Diagnostik, Markierung, Injektion, Dissektion bzw. Blutungsmanagement gemessen. Die Sensitivitäten für dieselben Parameter betrugen 1,00, 0,80, 0,94, 0,89 und 0,67, die Spezifitäten lagen bei 1,00, 1,00, 0,98, 0,88 und 0,93. Positive prädiktive Werte wurden mit 0,98, 1,00, 0,85, 0,94 und 0,43 gemessen. Schlussfolgerung: In dieser vorläufigen Studie zeigte ein KI-Algorithmus eine hohe Leistungsfähigkeit für die Einzelbild-Erkennung von Verfahrensphasen während der ESD. Die vergleichsweise niedrige Leistung für die Blutungsphase wurde auf das seltene Auftreten von Blutungsepisoden im Trainingsdatensatz zurückgeführt, der zu diesem Zeitpunkt nur Videos in voller Länge umfasste. Die zukünftige Entwicklung des Algorithmus wird sich auf die Reduzierung von Klassenungleichgewichten durch selektive Annotationsprotokolle konzentrieren. Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1811093 VL - 63 IS - 08 SP - e612 EP - e613 PB - Thieme CY - Stuttgart ER - TY - GEN A1 - Scheppach, Markus W. A1 - Rauber, David A1 - Zingler, C. A1 - Weber Nunes, Danilo A1 - Probst, Andreas A1 - Römmele, Christoph A1 - Nagl, Sandra A1 - Ebigbo, Alanna A1 - Palm, Christoph A1 - Messmann, Helmut T1 - Instrumentenerkennung während der endoskopischen Submukosadissektion mittels künstlicher Intelligenz T2 - Zeitschrift für Gastroenterologie N2 - Einleitung: Die endoskopische Submukosadissektion (ESD) ist eine komplexe Technik zur Resektion gastrointestinaler Frühneoplasien. Dabei werden für die verschiedenen Schritte der Intervention spezifische endoskopische Instrumente verwendet. Die präzise und automatische Erkennung und Abgrenzung der verwendeten Instrumente (Injektionsnadeln, elektrochirurgische Messer mit unterschiedlichen Konfigurationen, hämostatische Zangen) könnte wertvolle Informationen über den Fortschritt und die Verfahrensmerkmale der ESD liefern und eine automatische standardisierte Berichterstattung ermöglichen. Ziele: Ziel dieser Studie war die Entwicklung eines KI-Algorithmus zur Erkennung und Delineation von endoskopischen Instrumenten bei der ESD. Methodik: 17 ESD-Videos (9×rektal, 5×ösophageal, 3×gastrisch) wurden retrospektiv zusammengestellt. Auf 8530 Einzelbilder dieser Videos wurden durch 2 Studienmitarbeiter die folgenden Klassen eingezeichnet: Hakenmesser – Spitze, Hakenmesser – Katheter, Nadelmesser – Spitze und – Katheter, Injektionsnadel -Spitze und – Katheter sowie hämostatische Zange – Spitze und – Katheter. Der annotierte Datensatz wurde zum Training eines DeepLabV3+-Deep-Learning-Algorithmus mit ConvNeXt-Backbone zur Erkennung und Abgrenzung der genannten Klassen verwendet. Die Evaluation erfolgte durch 5-fache interne Kreuzvalidierung. Ergebnis: Die Validierung auf Einzelpixelbasis ergab insgesamt einen F1-Score von 0,80, eine Sensitivität von 0,81 und eine Spezifität von 1,00. Es wurden F1-Scores von 1,00, 0,97, 0,80, 0,98, 0,85, 0,97, 0,80, 0,51 bzw. 0,85 für die Klassen Hakenmesser – Katheter und – Spitze, Nadelmesser – Katheter und – Spitze, Injektionsnadel – Katheter und – Spitze, hämostatische Zange – Katheter und – Spitze gemessen. Schlussfolgerung: In dieser Studie wurden die wichtigsten endoskopischen Instrumente, die während der ESD verwendet werden, mit hoher Genauigkeit erkannt. Die geringere Leistung bei der hämostatische Zange – Katheter kann auf die Unterrepräsentation dieser Klassen in den Trainingsdaten zurückgeführt werden. Zukünftige Studien werden sich auf die Erweiterung der Instrumentenklassen sowie auf die Ausbalancierung der Trainingsdaten konzentrieren. Y1 - 2025 U6 - https://doi.org/10.1055/s-0045-1811092 VL - 63 IS - 8 PB - Thieme ER - TY - CHAP A1 - Klausmann, Leonard A1 - Rueckert, Tobias A1 - Rauber, David A1 - Maerkl, Raphaela A1 - Yildiran, Suemeyye R. A1 - Gutbrod, Max A1 - Palm, Christoph T1 - DIY challenge blueprint: from organization to technical realization in biomedical image analysis T2 - Medical Image Computing and Computer Assisted Intervention - MICCAI 2025 ; Proceedings Part XI N2 - Biomedical image analysis challenges have become the de facto standard for publishing new datasets and benchmarking different state-of-the-art algorithms. Most challenges use commercial cloud-based platforms, which can limit custom options and involve disadvantages such as reduced data control and increased costs for extended functionalities. In contrast, Do-It-Yourself (DIY) approaches have the capability to emphasize reliability, compliance, and custom features, providing a solid basis for low-cost, custom designs in self-hosted systems. Our approach emphasizes cost efficiency, improved data sovereignty, and strong compliance with regulatory frameworks, such as the GDPR. This paper presents a blueprint for DIY biomedical imaging challenges, designed to provide institutions with greater autonomy over their challenge infrastructure. Our approach comprehensively addresses both organizational and technical dimensions, including key user roles, data management strategies, and secure, efficient workflows. Key technical contributions include a modular, containerized infrastructure based on Docker, integration of open-source identity management, and automated solution evaluation workflows. Practical deployment guidelines are provided to facilitate implementation and operational stability. The feasibility and adaptability of the proposed framework are demonstrated through the MICCAI 2024 PhaKIR challenge with multiple international teams submitting and validating their solutions through our self-hosted platform. This work can be used as a baseline for future self-hosted DIY implementations and our results encourage further studies in the area of biomedical image analysis challenges. KW - Biomedical challenges KW - Image analysis KW - Blueprint KW - Do-It-Yourself KW - Self-hosting Y1 - 2025 SN - 978-3-032-05141-7 U6 - https://doi.org/10.1007/978-3-032-05141-7_9 SP - 85 EP - 95 PB - Springer CY - Cham ER - TY - INPR A1 - Gutbrod, Max A1 - Rauber, David A1 - Weber Nunes, Danilo A1 - Palm, Christoph T1 - OpenMIBOOD: Open Medical Imaging Benchmarks for Out-Of-Distribution Detection N2 - The growing reliance on Artificial Intelligence (AI) in critical domains such as healthcare demands robust mechanisms to ensure the trustworthiness of these systems, especially when faced with unexpected or anomalous inputs. This paper introduces the Open Medical Imaging Benchmarks for Out-Of-Distribution Detection (OpenMIBOOD), a comprehensive framework for evaluating out-of-distribution (OOD) detection methods specifically in medical imaging contexts. OpenMIBOOD includes three benchmarks from diverse medical domains, encompassing 14 datasets divided into covariate-shifted in-distribution, near-OOD, and far-OOD categories. We evaluate 24 post-hoc methods across these benchmarks, providing a standardized reference to advance the development and fair comparison of OOD detection methods. Results reveal that findings from broad-scale OOD benchmarks in natural image domains do not translate to medical applications, underscoring the critical need for such benchmarks in the medical field. By mitigating the risk of exposing AI models to inputs outside their training distribution, OpenMIBOOD aims to support the advancement of reliable and trustworthy AI systems in healthcare. The repository is available at this https URL. Y1 - 2025 U6 - https://doi.org/10.48550/arXiv.2503.16247 N1 - Der Aufsatz wurde peer-reviewed veröffentlicht und ist ebenfalls in diesem Repositorium verzeichnet unter: https://opus4.kobv.de/opus4-oth-regensburg/8467 ER - TY - JOUR A1 - Weiherer, Maximilian A1 - Eigenberger, Andreas A1 - Egger, Bernhard A1 - Brébant, Vanessa A1 - Prantl, Lukas A1 - Palm, Christoph T1 - Learning the shape of female breasts: an open-access 3D statistical shape model of the female breast built from 110 breast scans JF - The Visual Computer N2 - We present the Regensburg Breast Shape Model (RBSM)—a 3D statistical shape model of the female breast built from 110 breast scans acquired in a standing position, and the first publicly available. Together with the model, a fully automated, pairwise surface registration pipeline used to establish dense correspondence among 3D breast scans is introduced. Our method is computationally efficient and requires only four landmarks to guide the registration process. A major challenge when modeling female breasts from surface-only 3D breast scans is the non-separability of breast and thorax. In order to weaken the strong coupling between breast and surrounding areas, we propose to minimize the variance outside the breast region as much as possible. To achieve this goal, a novel concept called breast probability masks (BPMs) is introduced. A BPM assigns probabilities to each point of a 3D breast scan, telling how likely it is that a particular point belongs to the breast area. During registration, we use BPMs to align the template to the target as accurately as possible inside the breast region and only roughly outside. This simple yet effective strategy significantly reduces the unwanted variance outside the breast region, leading to better statistical shape models in which breast shapes are quite well decoupled from the thorax. The RBSM is thus able to produce a variety of different breast shapes as independently as possible from the shape of the thorax. Our systematic experimental evaluation reveals a generalization ability of 0.17 mm and a specificity of 2.8 mm. To underline the expressiveness of the proposed model, we finally demonstrate in two showcase applications how the RBSM can be used for surgical outcome simulation and the prediction of a missing breast from the remaining one. Our model is available at https://www.rbsm.re-mic.de/. KW - Statistical shape model KW - Non-rigid surface registration KW - Breast imaging KW - Surgical outcome simulation KW - Breast reconstruction surgery Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:898-opus4-30506 N1 - Corresponding author: Christoph Palm N1 - Zugehörige arXiv-Publikation: https://opus4.kobv.de/opus4-oth-regensburg/frontdoor/index/index/docId/2023 VL - 39 IS - 4 SP - 1597 EP - 1616 PB - Springer Nature ER -